Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
Building permit open since 2001
Needs a closer lookStill open in the City's records: 00 136228 (supply and install heating and cooling plants. ( no ductwork)see bp# 00116628 for revie..., 2001, status Inspection).
What it means. An open permit can mean work that was never finished or never passed final inspection. After closing, finishing it or closing the file can fall to you.
How to confirm. Ask the seller for the final inspection records. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016)9 development applications open within 300 m
Good to know9 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 40 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
16 records on file: more than at 100% of Toronto houses (median 0).
- Building permit25 123263Closed
replace sections of incoming 6" water main pipe downstream of supervisory valve
Apr 8, 2025 · 195 MERTON ST - Building permit20 182657Closed
Proposed to construct a bin enclosure structure, complete with structural slab, steel posts and joists perimeter will be enclosed with wood planking. structure will have 2 gates and 1 door. The roof shall be open timber planks.
Sep 24, 2020 · 195 MERTON ST - Building permit09 173516Closed - Dormant
Install 1 backflow prevention device on 2.5" domestic water pipe.
Oct 26, 2009 · 195 MERTON ST - Building permit05 165800Closed
Remove 2 interior partitions in existing condo unit (Suite 205)
Aug 15, 2005 · 195 MERTON ST - Zoning review02 158622 PLOClosedJul 29, 2002 · 195 MERTON ST
- Building permit01 183724Closed
demolish 1 storey sales pavillion building.
Oct 11, 2001 · 195 MERTON ST - Zoning review01 156947 000ClosedJul 10, 2001 · 195 MERTON ST
- Zoning review01 118991 000ClosedMar 16, 2001 · 195 MERTON ST
Show 8 older records
- Building permit00 345785Closed
Install 100 mm storm drain, 100 mm sanitary drain (buried drains) also install 3 sump pits, 1 elevator sump pit perimeter weeping tile & sub drains) cost incl. 99 - 116628 see 00 - 136232 (Bldg. C)
Mar 2, 2001 · 195 MERTON ST - Building permit00 136232Closed
install 10inch storm drain, 8inch sanitary drain, 6inch water service from street line to front wall of building. Bldg.C.) install fixtures in level P1- 8 v.f.d.; 1st floor- 12 w.c., 11 w.b., 9 b.t., 2 showers, 9 2-compt. k.s., 9 d.w., 9 l.t., 1 mop sink, 12 v.f.d., 1 urinal; 2nd to 5th floors- 21 w.c., 21 w.b., 19 b.t., 2 showers, 17 2-compt. k.s., 17 d.w.,17 l.t.; 6th to 11th floors- 9 w.c., 9 w.b., 9 b.t., 2 showers, 6 2-compt. k.s., 6 d.w., 6 l.t.; 12th floor- 10 w.c., 10 w.b., 10 b.t., 2 showers, 6 2-compt. k.s., 6 d.w., 6 l.t.; mechanical penthouse- 3 v.f.d, 10 roof drains. see bp# 00116628
Mar 2, 2001 · 195 MERTON ST - Building permit00 132300Closed
construct shoring and foundations to grade. see bp# 00-116628 CARD PRINTED
Mar 2, 2001 · 195 MERTON ST - Building permit00 136228Inspection
supply and install heating and cooling plants. ( no ductwork)see bp# 00116628 for reviewed HVAC drawings
Mar 2, 2001 · 195 MERTON ST - Building permit00 350652Closed
install window washing anchors system for apartment building (letter of intent). see bp# 99-116628 Mr. mahant is familiar. edc CARD PRINTED
Mar 1, 2001 · 195 MERTON ST - Building permit99 116628Closed
construct 12 storey apartment building with 2 level of below grade parking.
Feb 27, 2001 · 195 MERTON ST - Building permit00 136226Closed
supply and install sprinkler system for below grade portion of building. see bp# 00116628 CARD PRINTED
Nov 1, 2000 · 195 MERTON ST - Zoning review88 030773 LTOClosedNov 1, 1988 · 195 MERTON ST
Check before you build
Site-specific exception 900.11.10(2495)
Needs a closer look1 site-specific rule and 2 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
In a Commercial Residential zone, where the maximum lawfully permitted height exceeds the width of the right-of-way of the street it abuts then: (i) the angular plane requirements of regulations 40.10.40.70(2)(E) and 40.10.40.70(2)(G) do not apply; (ii) the rear yard setback requirements of regulation 40.10.40.70(2)(B) do not apply; and (iii) if the rear main wall of a building does not contain windows or openings: (a) the building must be set back at least 3.0 metres from any rear lot line that abuts a lot in the Residential Zone category; and (b) no building setback is required from any other zone category.
- Older by-law A
Section 12(2) 270(a) of former City of Toronto By-law 438-86
- Older by-law H
On 195 Merton St., and 253 Merton St. City of Toronto by-law 358-00.
6 parts for other addresses
- B On 35 Merton St., former City of Toronto by-law 96-0053
- C On the even numbered addresses of 64-84 Merton St., former City of Toronto by-laws 97-0523 and 97-0551
- D On 71 Merton St., former City of Toronto by-law 496-77
- E On 100 Merton St., former City of Toronto by-law 94-0579
- F On the lands municipally known as 137 to 147 Merton St. in 1992, Section 12(1) 308 of former City of Toronto By-law 438-86
- G On 119 Merton St., former City of Toronto by-laws 96-0055 and 97-0594
Lot facts
- Area
- 2,783 m²
- Frontage
- 74.1 m
- Depth
- 38.2 m
- Street
- Merton St
- Corner lot
- No
- Public lane
- None
- Max height
- 21 m
- Max lot coverage
- —
- Major Transit Station Area: Davisville. The lot is inside the Davisville Major Transit Station Area approved by the Province (Site and Area Specific Policy 722). Source
- Yonge-Eglinton Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Zone CR 2.0 (c2.0; r2.0) SS2 (x2495) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
- 1 City tree in front of this lot. The City's street tree inventory lists 1 tree at this address: fir, white (8 cm). Diameter is the trunk at breast height. Source
Around this lot
- Minor variances approved
- 100%7 of 7 decisions
- Garden suite permits
- 2
- Laneway suite permits
- 0
- Multiplex permits
- 0
- Development applications
- 19
Within 300 m, last 10 years. 2 suite and multiplex permits: no more than at most Toronto houses (median 3). 7 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To alter the existing 12-storey apartment building (Building A) by enclosing the double-height opening within Unit 417 (located on the fourth and fifth levels) for additional habitable space.
119 MERTON ST · Nov 19, 2025 · 148 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 39-2025(OLT)), for a new 31-storey residential building, by increasing the building height from 102.9 m to 104.6 m. This is currently being reviewed under Site Plan Control (File 20 21 234919 STE 12 SA). There will be a total of 273 residential dwelling units.
289 BALLIOL ST · Jul 23, 2025 · 325 m away - Minor varianceApproved
To alter the mezzanine levels within two adjacent dwelling units (units 1210 and 1216).
119 MERTON ST · May 31, 2023 · 148 m away - Minor varianceApproved
To legalize and to maintain the shed that has been constructed between the two-storey building and the detached garage, without the benefit of a building permit.
1913 YONGE ST · Jun 8, 2022 · 499 m away - Minor varianceApproved
To alter the existing two-storey office building by constructing a third-storey addition.
170 MERTON ST · Nov 4, 2015 · 56 m away
Latest activity nearby
- Consent (lot split)Pending
To obtain consent to sever the property into two stratified lots and to create new easements/rights-of-way. Also, to maintain existing easements/rights-of-way.
265 BALLIOL ST · Dec 2, 2026 · 294 m away - Zoning review
Not Started
170 MERTON ST · Nov 20, 2026 · 56 m away - Building permit
Installation of two mag-locks and associated equipment on exit doors serving the basement.
268 MERTON ST · Nov 10, 2026 · 237 m away - Zoning review
Closed
119 MERTON ST · Nov 3, 2026 · 148 m away - Zoning review
Notice Sent
275 MERTON ST · Oct 27, 2026 · 239 m away - Building permit
Proposal to erect a temporary air supported structure on an existing tennis court area. Tent to be in place from October 13, 2026 to April 13, 2027
185 BALLIOL ST · Oct 13, 2026 · 145 m away - Building permit
Targeted waterproofing renewal at the parking garage roof slab, including localized concrete repairs.
221 BALLIOL ST · Sep 11, 2026 · 182 m away - Building permit
Proposed concrete repairs at balcony slabs, shear walls, columns, end walls, roof parapet, exposed building floor slab edges, and entrance canopy; Replacement of balcony guards; Targeted masonry repairs and installation of an elastomeric coating/paint for the exterior walls; General replacement of exterior joint sealants (excluding window and balcony door perimeter joints).
265 BALLIOL ST · Aug 31, 2026 · 294 m away - Building permit
standpipe risers located within the contiguous scissor stairs
140 MERTON ST · Aug 28, 2026 · 108 m away - Building permit
Proposal for balcony repairs
221 BALLIOL ST · Aug 4, 2026 · 182 m away
Neighbourhood: South Eglinton-Davisville
About the area around the lot, not the lot itself.
- Nearest station
- Davisville Station9 min walk
- Nearest TTC stop
- Davisville Ave at Pailton Cres4 min walk
- Nearest cycling route
- Kay Gardiner Beltline TrlMulti-Use Trail, 1 min walk
- Nearest traffic count
- 5,774 vehicles in 8 hPailton Cres / Merton St, 160 m away, Dec 18, 2006
- Serious collisions within 500 m
- 42021–2026, killed or seriously injured: 2 fatal, 2 with pedestrians, 0 with cyclists
- Parks
- Kay Gardner Beltline Park1 min walk
- June Rowlands Park5 min walk
- Mount Pleasant Parkette7 min walk
Schools within 1 km
- DAVISVILLE & SPECTRUM SCHOOL English Public 7 min walk
- GREENWOOD COLLEGE SCHOOL Private 8 min walk
- TORONTO PREP SCHOOL Private 8 min walk
- HODGSON MIDDLE SCHOOL English Public 11 min walk
- SUNNYBROOK SCHOOL Private 11 min walk
- MANOR MONTESSORI - DE SAVERY SITE Private 11 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | South Eglinton-Davisville | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $80,000 | $84,500 |
| Households that own their home | 30% | 54% |
| Population (2021) | 22,735 | 16,813 |
| Homes built in 1960 or before | 11% | 29% |
| Homes needing major repairs | 3% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | South Eglinton-Davisville | City median |
|---|---|---|
| Assault | 436 | 636.3 |
| Robbery | 24.2 | 69.5 |
| Auto theft | 58.8 | 192.6 |
| Theft over $5,000 | 20.8 | 46.1 |
| Break and enter | 128 | 172.8 |
| Theft from vehicles | 100.3 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.