Everything here comes from public records: City of Toronto open data, TRCA and Statistics Canada, 15 sets in all. Each item leads to the record it comes from. Our sources
This house at a glance
Each score from 0 to 10: 0 needs attention, 10 all clear. Build potential is how much more you could add.
About 1305 Dundas St W
1305 Dundas St W is on a 20.2 m by 54.3 m lot on Dundas St W in Little Portugal. The zoning is CR. A site-specific exception, 900.11.10(2264), changes some of the usual rules for this address. The lot also fronts Coolmine Rd.
The City has 29 records on this lot since 1985. That is more than at 99% of Toronto houses. In 2026, a building permit was filed: "Proposed interior alterations to convert retail store to gym". Status: inspection. In 2026, a Committee of Adjustment application was filed: "To alter the existing three-storey mixed-use building by increasing the total interior floor area (recreational use for a gym) on the ground level. the…". Status: closed. In 2023, a building permit was filed: "Proposal for interior alterations to an existing restaurant, greater than 30 seats in the basement of an existing mixed use building". Status: inspection. 2 open permits mean the City has not closed the files. Ask the seller whether the work was finished and passed its final inspection.
No development applications are open within 300 m. Within 300 m, the Committee of Adjustment decided 77 minor variance applications in the last 10 years and approved 96%. The nearest TTC stop is Dundas St West at Rusholme Rd, a 1-minute walk.
Summary
What the City's records show on this house
- Building permit open since 2023ModerateFree check
- Work or applications in progressModerateFree check
- Site-specific exception 900.11.10(2264)Moderate
- 2 by-law investigations closed in the last two yearsLow
- 2 Committee of Adjustment files on this lotLowFree check
Left unchecked, any of these can mean unexpected costs, trouble after closing, or plans you can't carry out. Found before you offer, they give you room to negotiate. The full report explains what each one means for this house and what to do next.
15 sets of public records, already checked for you. Searching each one yourself and working out what it means for you takes time. We have done that work: what matters about this house and lot, in plain English, in a few minutes.
What to find out first
2 things to check before you offer.
What to find out before an offer, the steps to take, what each costs and how long it takesUnlock
Open City files
How much in the City's records needs answers before an offer
- Building permit open since 2023
- Work or applications in progress
- 2 by-law investigations closed in the last two years
What this part means for this house, in plain EnglishUnlock
Building permit open since 2023
ModerateCheck before you offerSee the open permit check for this house
What the record shows, what it means for you and what to doUnlock
Work or applications in progress
ModerateCheck before you offerSee the open permit check for this house
What the record shows, what it means for you and what to doUnlock
2 by-law investigations closed in the last two years
LowCheck if it appliesWhat the record shows, what it means for you and what to doUnlock
2 Committee of Adjustment files on this lot
LowFor later, once you own itSee the next door check for this house
What the record shows, what it means for you and what to doUnlock
What this means: Building permits before buyingWhat this means: Committee of Adjustment
City files on this lot
29 records on file, more than at 99% of Toronto houses (median 0 records).
| Date | Record | As the City filed it | In plain words | Status |
|---|---|---|---|---|
| 2026-08-13 | By-law investigation26 219055 PRS 00 IR | Property Standards | Closed | |
| 2026-02-17 | Building permit25 208946 | Proposed interior alterations to convert Retail store to Gym | Inspection | |
| 2026-01-21 | Minor varianceA0736/25TEY | To alter the existing three-storey mixed-use building by increasing the total interior floor area (recreational use for a gym) on the ground level. The existing basement level is unoccupied (used for storage space), and the second and third levels contain residential dwelling units, which will be maintained and unaltered. There is a total of 23 residential dwelling units on this lot. | Approved | |
| 2026-01-15 | By-law investigation26 105222 PRS 00 IR | Property Standards | Closed | |
| 2024-07-22 | Zoning review24 184989 ZAP | No description on file | Cancelled | |
| 2024-07-04 | Zoning review24 174660 ZAP | No description on file | Cancelled | |
| 2023-11-29 | Building permit23 223414 | Proposal for interior alterations to an existing restaurant, greater than 30 seats in the basement of an existing mixed use building. | Inspection | |
| 2020-11-23 | Zoning review20 221468 ZPR | No description on file | Closed | |
| 2019-11-12 | Building permit18 156331 | Revision 01: changes as per bubbled drawingsProposal for interior alterations to 2nd and 3rd floors of an existing 3-storey mixed-use (restaurant, retail store & dwelling units/rooms) building. Scope also includes front facade re-cladding.Proposed Uses on Second Floor: 14 - Bachelor/One Bedroom Dwelling UnitsProposed Uses on Third Floor: 10 - Bachelor/One Bedroom Dwelling Units | Closed | |
| 2019-02-20 | Building permit18 259783 | Revision # 01 - To increase the occupant load from 50 to 100.Change of Use Permit for a new Exhibition Gallery (No Construction) on the ground floor of the existing Multiple Unit Building. | Closed | |
| 2018-12-12 | Minor varianceA0725/18TEY | To alter to the existing the three-storey mixed-use building by converting all eight existing dwelling rooms into dwelling units for a total of 24 dwelling units. Construction will also include reconfiguring the indoor amenity space, recladding the front façade, and reconstructing the front basement stairs to the existing restaurant. | Approved | |
| 2018-10-22 | Building permit18 225148 | Install one backflow prevention device. | Closed | |
| 2013-04-05 | Zoning review13 145294 LPR | No description on file | Closed | |
| 2012-08-08 | Zoning review12 225862 LPR | No description on file | Closed | |
| 2009-05-22 | Zoning review09 140685 LPR | No description on file | Closed | |
| 2009-04-03 | Building permit09 123514 | Layout change to existing restaurant in basement to increase occupant load to 344. | Cancelled | |
| 2004-09-24 | Zoning review04 176561 LTO | No description on file | Closed | |
| 2003-09-08 | Zoning review03 172598 LTO | No description on file | Closed | |
| 2002-10-07 | Building permit02 170967 | Install h.v.a.c. system for 3rd floor. (dwelling portion) | Closed | |
| 2002-05-14 | Zoning review02 135957 LTO | No description on file | Closed | |
| 2002-04-18 | Building permit02 114751 | make interior alterations to 3rd floor, by converting to 3 dwelling units into 5 dwelling rooms, & 5 dwelling unit also converting 2nd fl from 19 rooming rooms and artist photography studio to 5 dwelling unit, 4 artist photography studios & 14 dwelling rooms | Closed | |
| 2002-03-21 | Zoning review02 120027 LTO | No description on file | Closed | |
| 2002-01-25 | Building permit01 188979 | make interior alterations to 2nd floor for (19 dwelling rooms and 4 Artist's/Photography Stuios. | Closed | |
| 2002-01-11 | Building permit02 102557 | Alter Plan Revision to B.P. 357068 issued 1994. Since there is no change to major occupancy or occupant load of ground floor, OBC Part 11 allows "Match Existing" that no need for Barrier-free washroom as long as no new washroom is proposed. | Closed | |
| 1997-05-02 | Zoning review97 026421 LTO | No description on file | Closed | |
| 1995-04-19 | Building permit95 015319 | INSTALL FIXTURES:- BSMT:- 4 2-COMPT. SINKS, 2 D.W., 8 W.B., 7 W.C., 3 URINALS, 1 W.T., 6 FLOOR DRAINS 1 SEWAGE PUMP REPLACE SANITARY & STORM DRAINS IN BUILDING | Closed | |
| 1994-11-14 | Building permit94 012567 | MAKE INTERIOR ALTERATIONS, CONSTRUCT BASEMENT ON WEST ELEVATION, ENLARGE THE 2ND FLOOR BY ENCLOSING THE FRONT BALCONY AND UNDERPIN EAST FOUNDATION WALL. SEE C OF A DECISION. HEALTH DEPT. APPROVAL IS REQUIRED. SF | Closed | |
| 1993-06-18 | Building permit93 016747 | CARRY OUT REMEDIAL WORK REQUIRED TO BE TAKEN TO RENDER THE BUILDING SAFE AS STIPULATED IN ORDER TO COMPLY DATED MAY 7,1993 AND ISSUED UNDER SECTION 10(2) OF THE BUILDING CODE ACT NOT APPROVED FOR ZONING PURPOSES SS/TC | Closed | |
| 1985-10-25 | Building permit85 023437 | MAKE INTERIOR ALTERATIONS AND BUILD RAMP ON WEST SIDE | Closed |
Restrictions
How much heritage, nature and site-specific rules limit changes to the house
- Site-specific exception 900.11.10(2264)
- No heritage listing or designation
What this part means for this house, in plain EnglishUnlock
Site-specific exception 900.11.10(2264)
ModerateCheck if it appliesWhat the record shows, what it means for you and what to doUnlock
What this means: Toronto zoning by address
If you want to change or build
What the site-specific rules mean for an addition, a garage or a rebuild.
Site-specific exception 900.11.10(2264)
What the exception changes for this address, rule by ruleUnlock
Flood and erosion rules
How much of the lot lies in the areas TRCA regulates for flooding and erosion
- Outside the areas TRCA regulates
From TRCA's regulated areas only. Basement flooding, sewer back-up and the TRCA flood plain are not in this score yet; ask the seller and your insurer about water in the basement.
What this part means for this house, in plain EnglishUnlock
Build potential
How much more the rules allow on this lot, beyond what is on record
What this part means for this house, in plain EnglishUnlock
The lot and what the rules allow
- Zone
- CR 2.5 (c1.0; r2.0) SS2 (x2264)
- Height limit
- 16 m
- Corner lot
- Yes, also on Coolmine Rd
- Public lane
- None
- House footprint
- 331 m²
- Back yard
- 0 m
- Buildings on the lot
- 3
House and yards from the City's 3D Massing; a survey gives exact figures.
What you can build
Why, measured on this lot, and the most you could buildUnlock
Building nearby
How much neighbours are building and applying to change within 300 m
- 6 development applications within 300 m in 10 years, none open
- 32 suite and multiplex permits within 300 m in 10 years
- 77 minor variance decisions within 300 m, 96% approved
What this part means for this house, in plain EnglishUnlock
What the City allowed next door
Within 500 m, last 10 years: a guide if you plan to build or apply for something similar.
What neighbours have built and changed around you, and how the City decidedUnlock
Area safety
Police-reported crime in the neighbourhood against the Toronto median
- Lower than the Toronto median in 2 of 7 categories
Neighbourhood rates per 100,000 people from the Toronto Police Service, not this street.
What this part means for this house, in plain EnglishUnlock
Little Portugal neighbourhood
About the area, not this house.
2021 Census, against the median Toronto neighbourhood
Getting around and schools
- Ossington StationNearest station24 min walk
- Dundas St West at Rusholme RdNearest TTC stop1 min walk
- Gladstone AveNearest cycling route5 min walk
- The Orchard Montessori SchoolSchool6 min walk
- Alexander Muir Gladstone Ave & the GroveSchool7 min walk
- Ossington Old Orchard Jr Public SchoolSchool8 min walk
- Pope Francis Catholic Elementary SchoolSchool8 min walk
Police-reported crime, 2025, per 100,000 people
- Assaultcity median 636.3726.9
- Robberycity median 69.532.8
- Shootingscity median 10.510.9
- Auto theftcity median 192.6120.2
- Theft over $5,000city median 46.149.2
- Break and entercity median 172.8180.4
- Theft from vehiclescity median 188.1191.3
Ready emails
Copy and send as they are.
5 questions for the seller and your lawyer, written outUnlock
What we checked, and what the City's records don't cover
We checked 48 sets of City of Toronto, TRCA and Statistics Canada open data for this address, last updated Nov 28, 2026. Our records don't cover flooding history, ownership and mortgages, or the condition of the house: ask the seller and your insurer about water in the basement, your lawyer about title, and book a home inspection.
See every source and when we loaded it · Pre-offer checklist