HousePrecheckCheck an address

970 Kipling AveToronto · zoning, lot size and permit records

Also 3801 Bloor St W

Commercial residential · CR 5.0 (c1.5; r3.5) SS1 (x377)≈ 100.2 × 143.6 m8,711 m²on Bloor St Wcorner, also on Kipling Ave

Not a home

Land without a building

The City's 3D model of buildings shows nothing standing on this parcel: vacant land, a parking lot or a yard. It is not a home for sale, so the house checks and the pre-offer report do not apply.

Looking at a house nearby? What this means for you

  • Empty land or parkingWhat gets built here matters most to the street: read the applications on it and around it below.
  • Permits or applications open on this parcelRecent records on this lot: 26 194744 (Stand-alone shoring and excavation permit in order to remediate the soil as needed, pri..., 2026); 26 179735 (Geothermal Borefield for the district energy system beneath 970 Kipling Avenue, consist..., 2026); 26 175993 WET 03 SA (Proposed 43-storey tower and a 28-storey tower. The Subject Site will include 839 purpo..., 2026). Larger work can mean noise and trucks next door; read what each one is for.
  • 6 development applications open within 300 m, up to 44 storeysNew buildings may go up around here in the next years. More change nearby than at 99% of Toronto houses.
  • Major Transit Station Area: KiplingThe City plans more homes around the station: good for transit, and more building over time.
N50 m
≈ 100.2 m frontage≈ 143.6 m deepirregular lot, estimated

Before you offer

From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.

  • Natural Heritage System (44% of lot)

    Good to know

    Part of the lot is in the Natural Heritage System shown on Official Plan Map 9.

    What it means. New buildings or additions in that part need a natural heritage impact study.

    How to confirm. City Planning confirms the policies that apply. Details

    City of Toronto Official Plan, Map 9
  • Work or applications in progress

    Good to know

    Recent records on this lot: 26 194744 (Stand-alone shoring and excavation permit in order to remediate the soil as needed, pri..., 2026); 26 179735 (Geothermal Borefield for the district energy system beneath 970 Kipling Avenue, consist..., 2026); 26 175993 WET 03 SA (Proposed 43-storey tower and a 28-storey tower. The Subject Site will include 839 purpo..., 2026).

    What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.

    How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details

    City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications
  • 6 development applications open within 300 m

    Good to know

    6 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 44 storeys. They are listed under Around this lot.

    What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.

    How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details

    City of Toronto, Development Applications

Not in these records

  • Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
  • Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.

History of this lot

7 records on file: more than at 97% of Toronto houses (median 0).

  • Building permit26 194744Permit Issued

    Stand-alone shoring and excavation permit in order to remediate the soil as needed, prior to start of construction of future apartments.

    Oct 9, 2026 · 970 KIPLING AVE
  • Development application26 226939 WET 03 OZClosed

    An application to amend the Zoning By-law to Lift the "(H)" Holding Symbol, applied by Zoning By-law 492-2026.

    Aug 27, 2026 · 970 KIPLING AVE · City file
  • Building permit26 179735Permit Issued

    Geothermal Borefield for the district energy system beneath 970 Kipling Avenue, consisting of 55 Bores and lateral piping.

    Jun 24, 2026 · 970 KIPLING AVE
  • Zoning review26 175993 PSPClosed
    Jun 11, 2026 · 970 KIPLING AVE
  • Development application26 175993 WET 03 SANOAC Issued

    Proposed 43-storey tower and a 28-storey tower. The Subject Site will include 839 purpose-built rental apartments comprised of 198 affordable units and 641 market units as well as approximately 13,560 SF of retail space.

    Jun 2, 2026 · 970 KIPLING AVE · City file
  • Development application26 127458 WET 03 OZClosed

    Proposed amendments to the site-specific zoning by-law for the Bloor-Kipling lands to permit a modified version of the approved mixed use building on Block 5 consisting of a 43-storey tower and a 28-storey tower with a common 5-storey podium and retail uses at grade. A total of 840 residential units are proposed, including 198 affordable units.

    Mar 24, 2026 · 970 KIPLING AVE · City file
  • Zoning review26 127458 PRZClosed
    Mar 17, 2026 · 970 KIPLING AVE

Check before you build

  • Site-specific exception 900.11.10(377)

    Needs a closer look

    27 site-specific rules apply to this lot. They can override the standard rules on this page.

    Zoning By-law 569-2013, Chapter 900
Exception 900.11.10(377)Applies

These parts of the exception apply to this lot's address.

  1. Rule A

    On 970 Kipling Avenue and 5207 Dundas Street West, a building , structure , addition or enlargement may be erected or used if it complies with

  2. Rule B

    to (VV) below: (B) For the purposes of this exception, each lot is separately comprised of "Area A" and "Area B" as shown on Diagram 2 of By-law 825-2021

  3. Rule C

    In accordance with clause 5.10.30.20, in "Area A" and "Area B" the lot line abutting Dundas Street West is the front lot line

  4. Rule D

    In addition to those uses of which an outdoor patio must be combined with listed in regulation 40.10.20.100(21)(A), a retail store is also a permitted use which can be combined with an outdoor patio

  5. Rule E

    Despite clause 40.10.30.40, the permitted maximum lot coverage is: (i) in "Area A" as shown on Diagram 2 of By-law 825-2021: 67 percent; and (ii) in "Area B" as shown on Diagram 2 of By-law 825-2021: 57 percent

  6. Rule F

    Despite regulation 40.10.40.1(1), all residential use portions of the building must be located above non-residential use portions of the building except for those uses located on the first, second, third and fourth storey above ground

  7. Rule G

    Regulation 40.10.40.1(6), with regards to locations of entrances when abutting residential uses, does not apply

  8. Rule H

    Despite regulations 40.5.40.10(1) and (2), the height of a building or structure is the vertical distance between the Canadian Geodetic Datum elevation of 126.25 metres for "Area A" and 133.1 metres for "Area B" as shown on Diagram 2 of By-law 825-2021 and the highest point of the building or structure

  9. Rule I

    Despite regulation 40.10.40.10(1), for the "Base Building" located in "Area A" as shown on Diagram 2 of By-law 825-2021: (i) for the portion of the building facing "Frontage A" as shown on Diagram 10 of By-law 825-2021, the permitted maximum height of a building or structure is 27.0 metres, except that: (a) a maximum of 39 metres of the portion of the building or structure facing "Frontage A" is permitted to have a height in addition to that permitted by (I)(i) above of 3.5 metres; (b) where a main wall stepback of at least 1.8 metres is provided from the main wall of the "Base Building" below it, or from the portion of the building permitted in (I)(i)(a) above, the cumulative permitted maximum height of a building or structure specified in (I)(i) and (I)(i)(a) above is increased by a further 7.0 metres; (c) a maximum of 63 metres of the portion of the building or structure facing "Frontage A" is permitted to have a height in addition to that permitted by (I)(i) above of 7.0 metres; and (d) where a main wall stepback of at least 2.8 metres is provided from the main wall of the "Base Building" below it, or from the portion of the building permitted in (I)(i)(c) above, the cumulative permitted maximum height of a building or structure specified in (I)(i) and (I)(i)(c) above is increased by a further 7.0 metres; (ii) for the portion of the building facing "Frontage B" as shown on Diagram 10 of By-law 825-2021, the permitted maximum height of a building or structure is 27.0 metres; (iii) for the portion of the building facing "Frontage C" as shown on Diagram 10 of By-law 825-2021, the permitted maximum height of a building or structure is 24.0 metres, except that: (a) where a main wall stepback of at least 2.2 metres is provided from the main wall of the "Base Building" below it, the permitted maximum height of a building or structure specified in (I)(iii) above is increased by 7.0 metres. (iv) for the portion of the building facing "Frontage D1" as shown on Diagram 10 of By-law 825-2021, the permitted maximum height of a building or structure is 30.0 metres, except that: (a) where a main wall stepback of at least 1.8 metres is provided from the main wall of the "Base Building" below it, the permitted maximum height of a building or structure specified in (I)(iv) above is increased by a further 7.0 metres. (v) for the portion of the building facing "Frontage D2" as shown on Diagram 10 of By-law 825-2021 the permitted maximum height of a building or structure is 34.0 metres; (vi) for the "Tower" area labelled as "Tower 1" on Diagram 10 of By-law 825-2021, the permitted maximum height of a building or structure is 65 metres, provided: (a) the "Tower" does not exceed a maximum floor area, measured from the exterior of the main wall of each floor level and inclusive of the entire floor, of 750 square metres; and (b) a minimum "Tower" separation distance of 25.0 metres between the main walls of "Tower 1" and "Tower 2" as shown on Diagram 10 of By-law 825-2021 is maintained; (vii) for the "Tower" labelled as "Tower 2" on Diagram 10 of By-law 825-2021, the permitted maximum height of a building or structure is 86.0 metres, provided: (a) the "Tower" does not exceed a maximum floor area, measured from the exterior of the main wall of each floor level and inclusive of the entire floor, of 750 square metres; (b) where the "Tower" is located above a height of 73.0 metres, the "Tower" must not exceed a maximum floor area of 675 square metres, measured from the exterior of the main wall of each floor level and inclusive of the entire floor; and (c) a minimum "Tower" separation distance of 25.0 metres between the main walls of "Tower 1" and "Tower 2" as shown on Diagram 10 of By-law 825-2021 is maintained; (viii) where the main wall of the "Base Building" contains dwelling units or indoor amenity space on the ground abutting the "Landscaped Courtyard Area", the permitted maximum building or structure height is 11.0 metres and any additional height as noted in (I)(i) to (v) above must be setback from the main wall of the building below it by a minimum of 6.0 metres; (ix) for the purpose of determining permitted maximum building and structure heights, the requirement commences from "Frontage A", "Frontage B", "Frontage C", "Frontage D1" and "Frontage D2" and proceeds into the interior of the lot at a right angle; (x) where any permitted maximum building or structure height requirement listed in (I)(i) to (v) above is in conflict based on a right angle projection of the Frontages as shown in Diagram 10 of By-law 825-2021, the greater permitted building or structure height prevails for the first 10 metres of that conflicting requirement; (xi) The permitted maximum building height for a "Tower" prevails over the permitted maximum building height for the "Base Building"; (xii) where a building or structure faces more than one Frontage as shown on Diagram 10 of By-law 825-2021, that portion of the building which faces the frontage with the greater permitted maximum building or structure height as described in (I)(i) to (v) above prevails, measured from the first 10 metres from that Frontage, projected at a right angle

  10. Rule J

    despite regulation 40.10.40.10(1), for the "Base Building" located in "Area B" as shown on Diagram 2 as shown on By-law 825-2021: (i) for the portion of the building or structure facing "Frontage A" as shown on Diagram 11 of By-law 825-2021 the permitted maximum height of a building or structure is 29.0 metres, except that: (a) a maximum of 32 metres of the portion of the building or structure facing "Frontage A" is permitted to have a height in addition to that permitted by (J)(i) above of 7.0 metres provided a main wall stepback of 3.0 metres from the main wall of the "Base Building" below it is maintained; and (b) a maximum of 31 metres of the portion of the building or structure facing "Frontage A" is permitted to have a height in addition to that permitted by (J)(i) above of 3.5 metres and a further 7.0 metres of height is permitted provided a minimum main wall stepback of 4.5 metres from the main wall of that portion of the building below it is maintained; (ii) for the portion of the building or structure facing "Frontage B" as shown on Diagram 11 as shown on By-law 825-2021 the permitted maximum height of a building or structure is 10.5 metres, except that: (a) for a maximum width of 27.0 metres of the portion of the building or structure facing "Frontage B", the permitted maximum height specified in (J)(ii) above is increased by 22.0 metres; (b) for a maximum width of 20.0 metres of the portion of the building or structure facing "Frontage B", the permitted maximum height specified in (J)(ii) above is increased by 18.5 metres; and (c) for a maximum width of 26 metres of the portion of the building or structure facing "Frontage B", the permitted maximum height specified in (J)(ii) above is increased by 25.5 metres; (iii) for the portion of the building facing "Frontage C" as shown on Diagram 11 of By-law 825-2021 the permitted maximum height of a building and structure is 34.5 metres; (iv) for the portion of the building facing "Frontage D" as shown on Diagram 11 of By-law 825-2021 the permitted maximum height of a building or structure is 10.5 metres, except that: (a) for a maximum width of 40 metres of the portion of the building facing "Frontage D", the permitted maximum height specified in (J)(iv) above is increased by 25.5 metres; and (b) for a maximum width of 34 metres of the portion of the building facing "Frontage D", the permitted maximum height specified in (J)(iv) above is increased by 18.5 metres; (v) for the area labelled "Historical Alignment" on Diagram 11 of By-law 825-2021, the permitted maximum height of a building or structure is 0 metres, except that: (a) landscaping and soft landscaping elements, public art structures , and park equipment such as benches, tables and outdoor fitness, recreation and play structures may exceed the permitted maximum height by 5.0 metres; (vi) for the "Tower" area labelled as "Tower 1" on Diagram 11 of By-law 825-2021, the permitted maximum height of a building or structure is 91 metres, provided: (a) where the "Tower" is located between a height of 36.0 metres and 66.9 metres, the "Tower" must not exceed a maximum floor area, measured from the exterior of the main wall of each floor level and inclusive of the entire floor, of 750 square metres; (b) where the "Tower" is located above a height of 67.0 metres, the "Tower" must not exceed a maximum floor area, measured from the exterior of the main wall of each floor level and inclusive of the entire floor, of 690 square metres; and (c) a minimum "Tower" separation distance of 25.0 metres between the main walls of "Tower 1" and "Tower 2" as shown on Diagram 11 of By-law 825-2021 is maintained. (vii) for the "Tower" labelled as "Tower 2" on Diagram 11 as shown on By-law 825-2021, the permitted maximum height of a building or structure is 42 metres, provided: (a) where the "Tower" is located above a height of 32.0 metres, the "Tower" must not exceed a maximum floor area of 750 square metres, measured rom the exterior of the main wall of each floor level and inclusive of the entire floor; and (b) a minimum "Tower" separation distance of 25.0 metres between the main walls of "Tower 1" and "Tower 2" as shown on Diagram 11 of By-law 825-2021 is maintained; (viii) for the purpose of determining permitted maximum building and structure heights, the requirement commences from "Frontage A", "Frontage B", "Frontage C", and "Frontage D" and proceeds into the interior of the lot projected at a right angle; (ix) where any permitted maximum building or structure height requirement listed in (J)(i) to (v) above is in conflict based on a right angle projection of the Frontages as shown in Diagram 11 of By-law 825-2021, the greater permitted building height prevails for the first 10 metres of that conflicting requirement; (x) The permitted maximum building height for a "Tower" prevails over the permitted maximum building height for the "Base Building"; (xi) where a building or structure faces more than one Frontage as shown on Diagram 11 of By-law 825-2021, that portion of the building which faces the frontage with the greater permitted maximum building or structure height as described in (J)(i) to (iv) above prevails, measured from the first 10 metres from that Frontage projected at a right angle

  11. Rule K

    Despite regulation 40.5.40.10(4), and in compliance with regulation 40.5.40.10(5), the following equipment and structures located on the roof of the "Base Building" may exceed the permitted maximum permitted building height: (i) equipment used for the functional operation of the building , such as electrical, utility, mechanical and ventilation equipment, structures or parts of the building used for the functional operation of the building , such as enclosed stairwells, roof access, maintenance equipment, storage, elevator shafts, chimneys, vents, and water supply facilities to a maximum extent of 7.0 metres; (ii) structures that enclose, screen or cover the equipment, structures and parts of a building listed in (K)(i) above to a maximum extent of 7.0 metres; and (iii) screens or other unenclosed structures used to mitigate wind or noise, balustrades, railings, guards, dividers, pergolas, trellises, eaves, privacy screens, skylights, access hatches, window washing equipment, lightning rods, terraces, landscaping elements, and structures located on the roof used for outdoor amenity space and outside or open air recreation, to a maximum extent of 3.0 metres

  12. Rule L

    Despite regulation 40.5.40.10(7), all parapets may exceed the permitted maximum height for a building by 2.0 metres

  13. Rule M

    Despite regulation 40.5.40.10(8), the following equipment and structures on the roof of a "Tower" may exceed the permitted maximum building height as specified: (i) equipment, structures or parts of a building listed in regulation (K)(i) and (ii) above by 7.0 metres, if the total area of those listed elements cover no more than 450 square metres, measured horizontally; (ii) exterior chimneys, pipes and vents may further exceed the permitted maximum building height, or exceed the permitted maximum height by an amount in addition to that described in (M)(i) above by 3.0 metres; (iii) screens or other unenclosed structures used to mitigate wind or noise, balustrades, railings, guards, dividers, pergolas, trellises, eaves, privacy screens, skylights, access hatches, window washing equipment, lightning rods, terraces, landscaping elements, and structures located on the roof used for outdoor amenity space and outside or open air recreation, to a maximum extent of 3.0 metres; and (iv) the definition of "Tower" in this by-law prevails over the definition of "tower" described in regulation 40.5.40.10(8)

  14. Rule N

    Despite regulation 40.5.75.1(2)(A)(ii), a photovoltaic solar energy device or a thermal solar energy device that is located on a building may exceed the permitted maximum height for a building by 2.0 metres, and where located on top of a mechanical penthouse, the devices may exceed the additional permitted maximum height of the mechanical penthouse by 2.0 metres

  15. Rule O

    Despite regulation 40.10.40.10(5), the required minimum height of the first storey is: (i) 4.5 metres for non-residential uses; (ii) 3.0 metres for residential uses; and (iii) a mezzanine shall not constitute a storey

  16. Rule P

    Regulation 40.10.40.10(7), with regards to the maximum number of storeys , does not apply

  17. Rule Q

    Despite regulation 40.10.40.40(1) in "Area A" as shown on Diagram 2 of By-law 825-2021, the permitted maximum gross floor area is 57,959 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 53,250 square metres; and (ii) the required minimum gross floor area for non-residential uses is 4,709 square metres

  18. Rule R

    Despite regulation 40.10.40.40(1) in "Area B" as shown on Diagram 2 of By-law 825-2021, the permitted maximum gross floor area is 49,314 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 45,795 square metres; and (ii) the required minimum gross floor area for non-residential uses is 3,519 square metres

  19. Rule S

    Despite regulation 40.5.40.40(3), the gross floor area of a mixed use building is reduced by the area in the building used for: (i) all areas located below ground; (ii) all loading spaces ; (iii) all bicycle parking spaces and the entirety of the room separated by demising walls containing those bicycle parking spaces ; (iv) all storage rooms, washrooms, electrical, utility, mechanical and ventilation rooms; (v) all shower and change facilities; (vi) all indoor amenity space ; (vii) elevator shafts; (viii) garbage shafts; (ix) mechanical penthouse; and (x) exit stairwells

  20. Rule T

    Despite regulation 40.10.40.50(1), in each of "Area A" and "Area B" as shown on Diagram 2 of By-law 825-2021, amenity space must be provided in accordance with the following: (i) a minimum of 2.0 square metres of indoor amenity space per dwelling unit ; (ii) a minimum of 2.0 square metres of outdoor amenity space per dwelling unit ; and (a) of the minimum required outdoor amenity space in "Area A", a minimum of 95 square metres of outdoor amenity space must be provided abutting the "Landscaped Courtyard Area"; (iii) at least 40.0 square metres of outdoor amenity space is required to be in location adjoining or directly accessible to the indoor amenity space ; and (iv) no portion of the green roof is considered outdoor amenity space

  21. Rule U

    Regulation 40.10.40.50(2), with regards to amenity space for buildings with non-residential uses in SS1 areas, does not apply

  22. Rule V

    Despite regulation 40.10.40.70(1), in "Area A" as shown on Diagram 2 of By-law 825-2021, the required minimum building setbacks are as follows: (i) for the portion of the building facing "Frontage A" as shown on Diagram 10 of By-law 825-2021: (a) the required minimum aggregate building setback of the main walls facing "Frontage A" must be equal to or greater than an average of 1.9 metres; (b) no more than 35 percent of the main walls may be directly abutting "Frontage A"; and (c) the permitted maximum length of any single continuous building setback is 35 percent of the main wall ; (ii) for the portion of the building facing "Frontage B" as shown on Diagram 10 of By-law 825-2021: (a) the required minimum building setback is 3.0 metres from the midpoint of the main wall for a minimum length of 30 metres in either direction from the midpoint of the main wall facing "Frontage B"; (b) no more than 15 percent of the main walls may be directly abutting "Frontage B"; and (c) despite (a) and (b) above, a building setback of 0 metres is permitted for the building located at the vertex of "Frontage B" and "Frontage C" as shown on Diagram 10 of By-law 825-2021; (iii) for the portion of the building facing "Frontage C" as shown on Diagram 10 of By-law 825-2021: (a) the required minimum aggregate building setback of the main walls facing "Frontage C" east of the selected opening to the "Gateway to Open Space Zone" as shown on By-law 825-2021 and described in (BB) below must be equal to or greater than an average of 3.0 metres; and (b) the required minimum building setback west of the selected opening to the "Gateway to Open Space Zone" as shown on Diagram 10 of By-law 825-2021 and described in (BB) below is 6.0 metres, measured only at the midpoint of that portion of the main wall facing "Frontage C"; (iv) for the portion of the building facing "Frontage D1" as shown on Diagram 10 of By-law 825-2021: (a) the required minimum building setback is 1.5 metres, except that a building setback of 0 metres for a maximum 15 percent of the main wall is permitted; (v) for the portion of the building facing "Frontage D2" as shown on Diagram 10 of By-law 825-2021: (a) the required minimum building setback is 3.0 metres measured only from the midpoint of the main wall facing "Frontage B"; (vi) required minimum building setbacks are measured from each Frontage as shown on Diagram 10 of By-law 825-2021, projected at a right angle; (vii) where any required minimum building setback listed in (V)(i) to (v) above is in conflict based on a right angle projection of the Frontages as shown in Diagram 10 of By-law 825-2021, the lesser required building setback prevails for the first 10 metres of that conflicting requirement; (viii) where a building faces more than one frontage as shown on Diagram 10 of By-law 825-2021, that portion of the building which faces the frontage with the lesser required building setback as described in (V)(i) to (v) above prevails, measured from the first 10 metres from that frontage, projected at a right angle; (ix) For the "Towers" shown as "Tower 1" and "Tower 2" on Diagram 10 of By-law 825-2021, the required minimum building setbacks are as shown on Diagram 10; and (a) required minimum building setbacks for "Tower 1" and "Tower 2" are only as they are shown on Diagram 10, otherwise building setbacks do not apply for "Tower 1" and "Tower 2"; (x) The required "Tower" building setbacks prevail over the required "Base Building" building setbacks ; (xi) No building or structure may penetrate a 45 degree angular plane as measured: (a) along the average elevation of the lot line of the closest lot located in the Residential Zone category or Residential Apartment Zone category; and (b) For "Area A" as shown on Diagram 2 of By-law 825-2021, along the average elevation of the south lot line of "the lands located northeast of the intersection of Kipling Avenue and Dundas Street West"

  23. Rule W

    Despite regulation 40.10.40.70(1), in "Area B" as shown on Diagram 2 of By-law 825-2021, the required minimum building setbacks are calculated as follows: (i) for the portion of the "Base Building" facing "Frontage A" as shown on Diagram 11 of By-law 825-2021, no minimum building setbacks are required except for those portions of the building located on the ground and below the second storey of the building , where: (a) a minimum building setback of 2.0 metres is required for a minimum of 43.0 metres of the main wall as measured from the northernmost point of the main wall and projecting south; (b) a combined minimum building setback of 3.0 metres is required for a minimum of 19.0 metres of the main wall ; and (c) a minimum building setback of 6.0 metres is required for a minimum 10.5 metres of the main wall located at the southernmost end of "Frontage A" and projecting north; (ii) for the portion of the "Base Building" facing "Frontage B" as shown on Diagram 11 of By-law 825-2021, no minimum building setbacks are required except for those portions of the building located on the ground and below the second storey of the building, where: (a) a minimum building setback of 2.0 metres is required, located at the easternmost end of "Frontage B" and projecting west, for a minimum width of 23 metres. This setback is to be measured at the midpoint of the 23 metre width from the main wall as it fronts on to "Frontage B"; (b) a minimum building setback of 3.0 metres, located at the westernmost end of "Frontage B", and projecting east, for a minimum width of 24 metres of the main wall ; and (c) where a required minimum building setback listed in (a) and (b) above is in conflict, the lesser required building setback prevails; (iii) for the portion of the "Base Building" facing "Frontage C" as shown on Diagram 11 of By-law 825-2021, the required minimum building setback is 1.0 metres, measured only at the midpoint of the main wall ; (iv) for the portion of the "Base Building" facing "Frontage D" as shown on Diagram 11 of By-law 825-2021, the required minimum building setback is 4.0 metres, except: (a) the portion of the building on the ground and located below the second storey containing dwelling units with direct entrances to each dwelling unit , the required building setback is 5.75 metres; (v) required minimum building setbacks are measured from each Frontage as shown on Diagram 11 of By-law 825-2021, projected at a right angle; (vi) where any required minimum building setback listed in (W)(i) to (iv) above is in conflict based on a right angle projection of the Frontages as shown in Diagram 11 of By-law 825-2021, the lesser required building setback prevails for the first 10 metres of that conflicting requirement; (vii) where a building faces more than one frontage as shown on Diagram 11 of By-law 825-2021, that portion of the building which faces the frontage with the lesser required minimum building setback as described in (W)(i) to (iv) above prevails, measured from the first 10 metres from that frontage, projected at a right angle; (viii) For the "Towers" shown as "Tower 1" and "Tower 2" on Diagram 11 of By-law 825-2021, the required minimum building setbacks are as shown on Diagram 11; and (a) required minimum building setbacks for "Tower 1" and "Tower 2" are only as they are shown on Diagram 11, otherwise building setbacks do not apply for "Tower 1" and "Tower 2"; (ix) The required "Tower" building setbacks prevail over the required "Base Building" building setbacks ; (x) No buildings or structures are permitted in the area labelled "Historical Alignment" on Diagram 11 as shown on By-law 825-2021, except: (a) landscaping and soft landscaping elements, public art structures, and park equipment such as benches, tables and outdoor fitness, recreation and play structures; (xi) No building or structure may penetrate a 45 degree angular plane as measured along the average elevation of the lot line of the closest lot located in the Residential Zone category or Residential Apartment Zone category

  24. Rule X

    Regulation 40.10.40.70(4), with regards to the required minimum building setback from the front lot line for residential uses on the first storey , does not apply

  25. Rule Y

    Despite regulation 40.10.40.60(1)(B), a platform or balcony attached to the main wall with a floor level higher than the floor level of the first storey of the building ; (i) must be located behind the main wall if located on a "Base Building"; or (ii) if located on the portion of a "Base Building" where additional height is permitted where a stepback is provided as described in (I) and (J) above, the platform or balcony may project into the required minimum building setback provided it does not exceed that required stepback.

  26. Rule Z

    Despite regulation 40.10.40.60(2)(B)(iii), a canopy, awning or similar structure , with or without structural support, or a roof over a platform, may not encroach into a required minimum building setback for the building where the minimum building setback is less than 1.0 metres except that: (i) in "Area B" as shown in Diagram 2 of By-law 825-2021, and abutting "Frontage B" and "Frontage C" as shown on Diagram 11 of By-law 825-2021, for no more than 50 percent of the length of either "Frontage B" or "Frontage C", a canopy is permitted to project into any required building setback provided it is located at or below the second storey

  27. Rule AA

    Despite regulation 40.10.50.10(1): (i) in "Area A" as shown on Diagram 2 of By-law 825-2021, a combined minimum of 1,825 square metres of landscaping and soft landscaping is required to be provided, which forms the "Landscaped Courtyard Area", of which also: (a) forms a continuous connection between the two "Gateway to Open Space Zones" identified on Diagram 10 of By-law 825-2021; (b) is "publicly accessible space"; and (c) the provision of an outdoor patio which is ancillary to non-residential uses reduces the required landscaping and soft landscaping requirement described in (AA)(i) above to a maximum of 10 percent of that required area; (ii) in "Area B" as shown on Diagram 2 of By-law 825-2021, a combined minimum of 560 square metres of landscaping and soft landscaping is required to be provided which must be provided in one continuous area, surrounded by at least three main walls ; (BB) in "Area A" as shown on Diagram 2 of By-law 825-2021, two pedestrian accesses to the "Landscaped Courtyard Area", with no obstructions by a building or structure as described below, must be provided in the "Gateway to Open Space Zones" as shown on Diagram 10 of By-law 825-2021, of which: (i) the southern pedestrian access to the "Landscaped Courtyard Area" will have a minimum width of 27.0 metres abutting "Frontage C" and must be open to the sky; and (ii) the northern pedestrian access to the "Landscaped Courtyard Area" will have a minimum width of 11.0 metres and a minimum height of 9.0 metres, as measured from the ground below it; (CC) Regulation 40.10.50.10(2), with regards to fence requirements if abutting a lot in the Residential or Residential Apartment Zone category, does not apply; (DD) Regulation 40.10.50.10(3), with regards to landscaping requirements if abutting a lot in the Residential or Residential Apartment Zone category, does not apply; (EE) Despite regulations 40.10.80.10(1) and 40.10.80.20(1) and (2), parking spaces are not permitted to be located above ground; (FF) Despite regulation 40.10.90.10(1), all loading spaces must be located inside a building ; (GG) Despite clauses 40.10.90.40 and 40.10.100.10, all vehicle access and access to loading spaces for "Area A" as shown in Diagram 2 of By-law 825-2021 is required to be from St. Alban's Road, Adobigok Pathway or Biindagen Trail and all vehicle access and access to loading spaces for "Area B" as shown in Diagram 2 of By-law 825-2021 is required to be from Beamish Drive; (HH) Despite regulation 200.5.1.10(2)(A)(iv), a maximum of 10 percent of obstructed parking spaces in each of "Area A" and "Area B" as shown on Diagram 2 of By-law 825-2021 are not required to provide 0.3 metres of additional width for each obstructed side; (II) Despite regulation 200.5.1.10(12)(C), a vehicle entrance or exit to the building must be at least 3.5 metres from the lot line abutting the street in "Area A" as shown on Diagram 2 of By-law 825-2021 and 0.7 metres for "Area B" as shown on Diagram 2 of By-law 825-2021; (JJ) Despite regulation 200.5.10.1(1) and Table 200.5.10.1, and in each of "Area A" and "Area B" as shown on Diagram 2 of By-law 825-2021, parking spaces must be provided in accordance with the following: (i) a minimum of 0.3 parking spaces and a maximum of 0.48 parking spaces for each dwelling unit for residential occupants; (ii) a minimum of 0.1 parking spaces for each dwelling unit for residential visitors; (iii) a minimum of 1.0 parking spaces for each 100 square metres of gross floor area for non-residential uses, except that: (a) no parking spaces are required for a community centre or day nursery ; (iv) For each of the morning, afternoon and evening parking periods identified in Table 1 of By-law 825-2021, the required minimum number of parking spaces for each use is calculated using the respective parking space requirement rate outlined in (JJ)(i) to (iii) above multiplied by the shared parking occupancy rate in Table 1, and: (a) the minimum number of parking spaces required for each parking period is the total of the parking spaces required for all uses during that parking period; and (b) the minimum number of parking spaces required for all uses on the lot , is equal to the largest number of parking space required for a parking period. (v) "car-share parking spaces" may replace parking spaces otherwise required for residential occupants, subject to the following: (a) a reduction of four residential occupant parking spaces will be permitted for each "car-share" parking space provided and that the maximum reduction be capped by the following formula: 4 [multiplied by] (total number of dwelling units divided by 60), rounded down to the nearest whole number; (vi) Despite regulation 40.5.80.1(1), 40 percent of parking spaces required by (JJ)(i)(ii) and (iii) above may be provided as public parking on a non-exclusive basis; (KK) Despite regulation 40.5.80.10(1), a maximum of 30 percent of the required residential visitor and non-residential parking spaces for each of "Area A" and "Area B" as shown on Diagram 2 of By-law 825-2021 may be provided on "the lands located northeast of the intersection of Kipling Avenue and Dundas Street West"; (LL) Despite regulation 200.5.1.10(2) and 200.5.1(3), any parking space provided as part of public parking may have a minimum length of 5.2 metres, provided they are accessed by a drive aisle having a width of 7.0 metres or greater; (MM) Despite regulation 200.15.1(1), an accessible parking space must have the following dimensions: (i) length of 5.6 metres; (ii) width of 3.4 metres; and (iii) vertical clearance of 2.1 metres; (NN) Despite regulation 200.15.1(4), accessible parking spaces must be parking spaces located closest to a pedestrian access to a building or a passenger elevator that provides access to the first storey of the building ; (OO) Despite regulation 200.15.10(1), accessible parking spaces must be provided at the following minimum rates: (i) if the number of required parking spaces is 25 to 100, a minimum of 1 accessible parking space for every 25 parking space or part thereof; and (ii) if the number of required parking spaces is greater than 100, a minimum of 4 accessible parking spaces plus 1 accessible parking space for every 50 parking spaces or part thereof, in excess of 100 parking spaces ; (PP) Despite clause 220.5.10.1 and regulation 40.10.90(1), loading spaces must be provided in accordance with the following: (i) in "Area A" as shown in Diagram 2 of By-law 825-2021, a minimum of 1 Type "B" loading space , 2 Type "C" loading spaces and 1 Type "G" loading space , is required; and (ii) in "Area B" as shown in Diagram 2 of By-law 825-2021, a minimum of 1 Type "C" loading space , and 1 Type "G" loading space , is required; (QQ) despite regulation 230.5.1.10(10), both "short-term" and "long-term" bicycle parking spaces may be located in a stacked bicycle parking space ; (RR) regulation 230.5.1.10(4) will apply with the exception that, if a stacked bicycle parking space is provided in a mechanical device, where any portion of a bicycle is situated above or below any portion of an adjacent bicycle, the minimum required width of each such stacked bicycle parking space is 0.43 metres; (SS) Despite regulation 230.5.10.1(6), to calculate bicycle parking space requirements for other than dwelling units , the interior floor area of a building is reduced by the area in the building used for: (i) all areas located below ground; (ii) all loading spaces ; (iii) all bicycle parking spaces and the entirety of the room separated by demising walls containing those bicycle parking spaces ; (iv) all storage rooms, washrooms, electrical, utility, mechanical and ventilation rooms; (v) all shower and change facilities; (vi) all indoor amenity space ; (vii) elevator shafts; (viii) garbage shafts; (ix) mechanical penthouse; and (x) exit stairwells; (TT) In each of "Area A" and "Area B", and applied either independently or collectively: (i) a minimum of 25 percent of the total number of dwelling units must contain two bedrooms; and (ii) a minimum of 10 percent of the total number of dwelling units must contain three bedrooms; (UU) In each of "Area A" and "Area B", and applied either independently or collectively: (i) a minimum of 10 percent of the total number of dwelling units must contain two bedrooms containing a minimum interior floor area of 87 square metres each; and (ii) a minimum of 7 percent of the total number of dwelling units must contain three bedrooms containing a minimum interior floor area of 100 square metres each; and (VV) In "Area A" as shown on Diagram 2 of By-law 825-2021, 14 dwelling units which abut the "Landscaped Courtyard Area" are required as part of the mixed use building , and each of those dwelling units shall have exclusive use of a yard comprised of a minimum area of 18 square metres of combined landscaping and soft landscaping , and: (i) the landscaping and soft landscaping requirement is in addition to that required by (AA) above.

By-law 569-2013, Chapter 900

Lot facts

Area
8,711 m²
Frontage
100.2 mestimated, irregular lot
Depth
143.6 mestimated, irregular lot
Street
Bloor St W
Corner lot
Yes, also on Kipling Ave143.6 m along it
Public lane
None
Max height
15 m
Max lot coverage
33%
  • Major Transit Station Area: Kipling. The lot is inside the Kipling Major Transit Station Area approved by the Province (Site and Area Specific Policy 626). Source
  • Etobicoke Centre Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
  • Zone CR 5.0 (c1.5; r3.5) SS1 (x377) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source

Around this lot

Minor variances approved
83%10 of 12 decisions
Garden suite permits
1
Laneway suite permits
0
Multiplex permits
0
Development applications
18

Within 300 m, last 10 years. 1 suite and multiplex permits: no more than at most Toronto houses (median 3). 12 variance decisions: no more than at most Toronto houses (median 19).

Recent variance decisions in the same zone

  • Minor varianceApproved

    To alter the development standards as outlined in By-law 304-2025 (OLT) to accommodate a 44-storey mixed-use building containing 521 residential units.

    4 BEAMISH DR · Jul 16, 2026 · 127 m away
  • Minor varianceApproved

    To permit design changes for the proposed sports court facility.

    5207 DUNDAS ST W · May 28, 2026 · 210 m away
  • Minor varianceApproved

    To alter the development standards as outlined in By-law 924-2024 in order to accommodate a 41-storey purpose-built rental building that will contain a total of 521 residential units.

    5238 DUNDAS ST W · Oct 23, 2025 · 309 m away
  • Minor varianceApproved

    To permit a bicycle parking space deficiency in order to accomodate the development of a fifty-storey mixed use building.

    5251 DUNDAS ST W · Aug 14, 2025 · 356 m away
  • Minor varianceApproved

    To modify the development standards from site specific By-law 963-2023 related to setbacks, height, canopy depth, and the podium and tower floorplate.

    5 JOPLING AVE S · Mar 20, 2025 · 268 m away

Latest activity nearby

  • Consent (lot split)Pending

    Accepted

    980 KIPLING AVE · Nov 23, 2026 · 184 m away
  • Minor variancePending

    Accepted

    980 KIPLING AVE · Nov 23, 2026 · 184 m away
  • Minor variancePending

    Accepted

    980 KIPLING AVE · Nov 23, 2026 · 184 m away
  • Building permit

    Interior alterations and fitup to the Ground, 3rd and 4th Floor for a new Daycare Facility

    5207 DUNDAS ST W · Nov 18, 2026 · 210 m away
  • Building permit

    Supply and install (2) replacement like for like HVAC roof top units.

    3835 BLOOR ST W · Nov 10, 2026 · 256 m away
  • Development application

    Proposed scope of work consists of the conversion of, and addition to, an existing nursing home to accommodate a municipal shelter with 60 beds. The project includes net-zero building retrofits, building envelope upgrades and barrier-free renovations.

    3838 BLOOR ST W · Nov 3, 2026 · 274 m away · City file
  • Minor variancePending

    In Progress

    2 BOTFIELD AVE · Oct 30, 2026 · 247 m away
  • Building permit

    Revision 01: Addition of a dedicated generator room within the Enwave district energy plant electrical roomProposal for Enwave district energy plant at the Etobicoke Civic Centre. Includes below grade plant room and Level 16 roof.

    3755 BLOOR ST W · Oct 23, 2026 · 132 m away
  • Building permit

    Stand-alone shoring and excavation permit in order to remediate the soil as needed, prior to start of construction of future apartments.

    970 KIPLING AVE · Oct 9, 2026 · 27 m away
  • Zoning review

    Notice Sent

    980 KIPLING AVE · Oct 2, 2026 · 184 m away

Neighbourhood: Etobicoke City Centre

About the area around the lot, not the lot itself.

Nearest station
Kipling Station6 min walk
Nearest TTC stop
Dundas St West at Kipling Ave1 min walk
Nearest cycling route
Kipling AveCycle Track, 1 min walk
Nearest traffic count
20,429 vehicles in 8 hKipling Ave / Dundas St W, 90 m away, Dec 16, 2023
Serious collisions within 500 m
62021–2026, killed or seriously injured: 2 fatal, 3 with pedestrians, 0 with cyclists
Parks
Six Points Park2 min walk
Fieldway Parkette9 min walk
Michael Power Park9 min walk

Schools within 1 km

  • MINDWERX4KIDS LEARNING CENTRE SCHOOL Private 2 min walk
  • ACADEMY OF MATH AND ENGLISH Private 9 min walk
  • OUR LADY OF PEACE CATHOLIC ELEMENTARY SCHOOL English Separate 12 min walk
  • ISLINGTON JR MDL SCHOOL English Public 16 min walk
  • WEDGEWOOD JR SCHOOL English Public 16 min walk

Being near a school does not mean the lot is in its catchment; check with the board.

2021 Census

FigureEtobicoke City CentreMedian neighbourhood
Median household income (2020)$83,000$84,500
Households that own their home50%54%
Population (2021)23,60016,813
Homes built in 1960 or before9%29%
Homes needing major repairs4%7%

Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.

Police-reported crime, 2025

Per 100,000 peopleEtobicoke City CentreCity median
Assault844.4636.3
Robbery187.769.5
Shootings16.210.5
Auto theft601.8192.6
Theft over $5,000200.646.1
Break and enter210.3172.8
Theft from vehicles278.2188.1

Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.

Something here not right?

Sources

  • Building permits on this lot since 2000: Permits issued or applied for since about 2000, with status.
  • Committee of Adjustment files since 2001: Minor variances and consents (lot splits) on this lot and nearby, with decisions.
  • Development applications: Rezoning, site plan, subdivision and condominium applications.
  • Preliminary zoning reviews: Zoning reviews requested before a permit or variance application.
  • Zoning and overlays: Zoning By-law 569-2013 zone, height, coverage, policy area, parking, rooming house, priority retail street and downtown setback overlays.
  • Lot boundary, street and lane: Lot polygon, its addresses, the street it fronts, corner and public lane contact, with frontage and depth measured from the boundary; City of Toronto land in City use, which is not a home.
  • House and yards: Footprint and roof height of the house and other buildings, and the yard behind the house, from the City's 3D Massing (updated yearly, illustrative).
  • City trees in front of the lot: City-owned trees on the street allowance at this address, with species and trunk diameter. Private trees on the lot are not in open data.
  • Heritage: Heritage Register (listed and designated properties), Official Plan Amendment 720 properties and properties removed from the Register under the 2022 two-year limit.
  • TRCA regulated area: Valleys, floodplains, shorelines and wetlands regulated by the Toronto and Region Conservation Authority.
  • Ravines and natural features: Ravine and Natural Feature Protection area (Chapter 658, map last published 2019), Natural Heritage System and Environmentally Significant Areas.
  • Official Plan policies: Site and Area Specific Policies, Secondary Plans and Major Transit Station Areas covering the lot.
  • Rooming houses, short-term rentals and rental buildings: Multi-tenant house licences, short-term rental registrations and RentSafeTO evaluations at this address.
  • Neighbourhood context: Neighbourhood, 2021 Census figures, police-reported crime rates, schools, parks, TTC stops, cycling routes, serious collisions and traffic counts nearby. Area context only, not a finding about the lot.
  • Orders and by-law investigations: Outstanding Toronto Building orders, and by-law investigations open now or closed in the last two years. Fire and Public Health orders and older closed files are not published.
  • Address points: loaded Nov 22, 2026, published Nov 20, 2026
  • Toronto Building orders: loaded Nov 27, 2026, published Nov 26, 2026
  • Neighbourhood Profiles, 2021 Census: loaded Oct 14, 2026, published Oct 6, 2023
  • Street centrelines: loaded Nov 22, 2026, published Nov 20, 2026
  • City-owned land: loaded Nov 22, 2026, published Nov 16, 2026
  • Committee of Adjustment open applications: loaded Nov 27, 2026, published Nov 26, 2026
  • Committee of Adjustment decisions: loaded Nov 27, 2026, published Nov 26, 2026
  • Committee of Adjustment decisions 2001-2016: loaded Oct 14, 2026, published Feb 20, 2026
  • Collisions with people killed or seriously injured (Toronto Police Service): loaded Nov 22, 2026, published Nov 21, 2026
  • Neighbourhood crime rates (Toronto Police Service): loaded Oct 14, 2026, published Feb 20, 2026
  • Cycling network: loaded Nov 22, 2026, published Nov 16, 2026
  • Development applications: loaded Nov 27, 2026, published Nov 27, 2026
  • Environmentally Significant Areas: loaded Oct 14, 2026, published Mar 16, 2026
  • Green spaces: loaded Nov 15, 2026, published Nov 10, 2026
  • Heritage register: loaded Oct 14, 2026, published Sep 1, 2026
  • Former heritage listings: loaded Oct 14, 2026, published Jul 3, 2025
  • Official Plan Amendment 720 heritage list: loaded Oct 14, 2026, published Sep 1, 2026
  • 3D Massing building footprints: loaded Oct 14, 2026, published Dec 2, 2025
  • By-law investigation addresses: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigation deficiencies: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigations: loaded Nov 27, 2026, published Nov 26, 2026
  • Major Transit Station Areas: loaded Oct 14, 2026, published Feb 3, 2026
  • Natural Heritage System: loaded Oct 14, 2026, published Mar 16, 2026
  • Neighbourhoods: loaded Oct 14, 2026, published Feb 20, 2026
  • Property boundaries: loaded Nov 27, 2026, published Nov 27, 2026
  • Active building permits: loaded Nov 27, 2026, published Nov 26, 2026
  • Cleared building permits: loaded Nov 27, 2026, published Nov 26, 2026
  • Cleared building permits 2000-2016: loaded Oct 14, 2026, published Jul 8, 2025
  • Preliminary zoning reviews: loaded Nov 27, 2026, published Nov 26, 2026
  • Ravine and natural feature protection: loaded Oct 14, 2026, published Jul 23, 2019
  • RentSafeTO evaluations: loaded Nov 27, 2026, published Nov 26, 2026
  • Multi-tenant house licences: loaded Nov 27, 2026, published Nov 26, 2026
  • Site and Area Specific Policies: loaded Oct 14, 2026, published Mar 16, 2026
  • School locations: loaded Oct 14, 2026, published May 27, 2026
  • Secondary Plans: loaded Oct 14, 2026, published Mar 16, 2026
  • Street trees: loaded Oct 14, 2026, published Jun 4, 2026
  • Short-term rental registrations: loaded Nov 27, 2026, published Nov 26, 2026
  • Traffic counts at intersections: loaded Nov 22, 2026, published Nov 21, 2026
  • TRCA regulation limit: loaded Oct 14, 2026, published Apr 29, 2026
  • TTC stops (GTFS): loaded Nov 8, 2026, published Nov 5, 2026
  • Zoning by-law: loaded Oct 14, 2026, published Feb 20, 2026
  • Lot coverage overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Height overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Parking zone overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Policy area overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Priority retail streets: loaded Oct 14, 2026, published Feb 20, 2026
  • Rooming house overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Zoning setbacks: loaded Oct 14, 2026, published Feb 20, 2026

Contains information licensed under the Open Government Licence – Toronto. TRCA regulation limit © TRCA.

Screening tool based on City of Toronto and TRCA open data. Not a zoning review or legal opinion. Site-specific exceptions, amendments not yet in the open data, minor variances and other by-laws can change the answer. Confirm with a Preliminary Project Review or Zoning Certificate from Toronto Building before buying or designing.

Flag an error

What is not right?

The problem