Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
Heritage property: in a Heritage Conservation District (Part V)
Needs a closer lookOn the City's Heritage Register. Demolition and exterior changes need heritage review.
What it means. Renovations, additions and demolition can take longer, cost more or be refused.
How to confirm. Heritage Planning at the City confirms the status and what it covers. Details
City of Toronto Heritage RegisterBuilding permit open since 2014
Needs a closer lookStill open in the City's records: 14 241282 (Proposal for interior alterations to existing retail space in the existing building.Ten..., 2014, status Inspection).
What it means. An open permit can mean work that was never finished or never passed final inspection. After closing, finishing it or closing the file can fall to you.
How to confirm. Ask the seller for the final inspection records. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016)2 by-law investigations closed in the last two years
Good to knowClosed files (Order Issued Property Standards, Property Standards): 25 223556 PRS 00 IV (Order Issued Property Standards, 2025); 25 210939 PRS 00 IR (Property Standards, 2025).
What it means. Someone raised an issue here and the City closed the file. Ask the seller what it was about.
City of Toronto, Toronto Building orders and Municipal Licensing and Standards investigations1 Committee of Adjustment file on this lot
Good to know1 approved. B091/00TO (This application includes 81 and 85 Front Street East. The proposed conveyance is a "ho..., 2000).
What it means. Approved variances and consents stay with the property, including any conditions in the decision. They allow what was approved, not more.
How to confirm. Decisions are in the Application Information Centre; older files are available from the Committee of Adjustment office. Details
City of Toronto, Committee of Adjustment applications (2001 onwards)5 development applications open within 300 m
Good to know5 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 46 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
64 records on file: more than at 100% of Toronto houses (median 0).
- By-law investigation26 117539 SNI 00 IVClosed
Notice Issued Snow and Ice: Exterior areas including: steps, landings, walks, driveways, parking spaces, ramps have not been cleared of snow and ice within twenty four (24) hours of a snow
Feb 13, 2026 · 83 FRONT ST E - By-law investigation26 117264 SNI 00 IRClosed
Snow and Ice
Feb 13, 2026 · 83 FRONT ST E - By-law investigation25 223556 PRS 00 IVClosed
Order Issued Property Standards
Aug 15, 2025 · 81 FRONT ST E - By-law investigation25 210939 PRS 00 IRClosed
Property Standards
Aug 15, 2025 · 81 A FRONT ST E - Building permit25 194053Refusal Notice
Proposed plumbing installation for existing apartment dwelling.
Jul 15, 2025 · 81 A FRONT ST E - Building permit23 192643Cancelled
Basement alterations for the storage of wine for clients in individual storage lockers.
Aug 23, 2023 · 77 FRONT ST E - Building permit22 178170Closed
To erect and display two first party signs, illuminated and displaying static copy, on the north elevation, with the following details:Sign 1: a wall sign, with a face measuring 0.70m vertically by 3.19m horizontally at a height of 4.67m, on the second storey;Sign 2: a projecting sign, with two sign faces measuring 0.69m vertically by 0.69m horizontally each, at a height of 3.19m, on the first storey.****AU PAIN DORE****
Sep 12, 2022 · 81 FRONT ST E - Building permit22 171221Closed
Interior alterations to an existing restaurant under 30 seats for a new restaurant under 30 seats
Jul 18, 2022 · 81 FRONT ST E
Show 56 older records
- Building permit21 205993Closed
Application for a permit to erect and display three wall signs and one projecting, all illuminated.*****CANNA CABANA*****
Jan 19, 2022 · 77 FRONT ST E - Zoning review21 175025 ZPRClosedJun 23, 2021 · 77 FRONT ST E
- Building permit20 198138Closed
To erect and display two illuminated wall signs.****META CANNABIS CO****
Dec 3, 2020 · 77 FRONT ST E - Building permit20 161461Closed
To erect and display two wall signs and one projecting sign, all illuminated and displaying static copy. Erected on the south elevation of the building.****A & W****
Oct 15, 2020 · 85 FRONT ST E - Building permit20 146549Closed
Proposal for interior alteration to create a new A&W restaurant.
Sep 14, 2020 · 85 FRONT ST E - Building permit20 138086Closed
Proposal for interior alterations to existing retail store for a tenant fit out of a new retail store - Meta Growth
May 25, 2020 · 77 FRONT ST E - Building permit17 247542Closed
Proposal to conduct remedial work to floor framing.
Oct 30, 2017 · 81 FRONT ST E - Building permit17 178045Closed
New fixtures to *Starbucks*
Jul 6, 2017 · 81 FRONT ST E - Building permit17 140143Closed
In conjunction with a multi-storey building on the premises, proposal to erect and display one illuminated wall sign and one illuminated projecting sign displaying static copy on the first storey north elevation. The proposed wall sign is 1.55 metres vertically by 1.65 metres horizontally at a height of 4.0 metres above grade. The proposed projecting sign contains two sign faces, back to back, each sign face measuring 0.46 metres vertically by 0.61 metres horizontally at a height of 2.96 metres above grade.**BELL**
May 11, 2017 · 77 FRONT ST E - Building permit17 109455Closed
Interior alterations to ground floor to change use from restaurant (less than 30) to retail spacer. Tenant - "Bell". CONVENIENCE ADDRESS - 79 FRONT ST E.
Mar 3, 2017 · 77 FRONT ST E - Building permit16 183612Closed
Proposal to replace a exiting fire alarm panel.
Jul 4, 2016 · 85 FRONT ST E - Building permit16 172308Cancelled
In conjunction with a multi-storey building on the premises, proposal to erect and display four illuminated wall signs, all displaying static copy, located on the first and second(?) storey of the north elevation. One of the wall signs measure 0.74 metre vertically by 4.59 metres horizontally. Three of the wall signs measure 0.33 metres vertically by 2.21 metres horizontally.**Paramount Middle Eastern Cuisine**
Jun 15, 2016 · 85 FRONT ST E - Building permit15 253563Closed
REV - 01 to the HVAC - layout only,
May 17, 2016 · 85 FRONT ST E - Building permit14 241282Inspection
Proposal for interior alterations to existing retail space in the existing building.Tenant: Tilley
Nov 17, 2014 · 77 FRONT ST E - Zoning review13 122973 LTOClosedFeb 21, 2013 · 77 FRONT ST E
- Building permit12 285372Closed
To erect and display one non-illuminated wall sign at the second storey of the northerly elevation of the subject building, in conjunction with a coffee shop. **Starbucks**
Dec 18, 2012 · 81 FRONT ST E - Building permit11 133544Closed
Proposal for revision to kitchen exhaust system in existing restaurant greater than 30 seats - Hero Burger. (Related building permit 11 133531 BLD)
Nov 21, 2012 · 77 FRONT ST E - Building permit12 183268Closed
Interior alterations to existing cafe on the ground floor. Occupant load = 36 + 4 staff. Existing + Proposed tenant - "Starbucks".
Jun 19, 2012 · 81 FRONT ST E - Building permit11 252888Closed
To erect and display two illuminated overhanging structure signs, each with static copy and each at the northerly-facing first storey building wall in conjunction with a new restaurant located at the ground floor of an existing heritage building located on the premises. **Hero Burger**
Sep 15, 2011 · 79 FRONT ST E - Building permit11 133531Closed
Permit for interior alterations to existing restaurant greater than 30 seats - Hero burger.
Mar 7, 2011 · 77 FRONT ST E - Building permit10 287852Closed
Proposal to install 1 backflow prevention device in an existing apartment building.
Nov 3, 2010 · 81 A FRONT ST E - Zoning review08 191450 ZALCancelledAug 8, 2008 · 77 FRONT ST E
- Zoning review05 157467 LTOClosedJul 8, 2005 · 77 FRONT ST E
- Zoning review04 151494 LTOClosedJun 29, 2004 · 77 FRONT ST E
- Building permit02 183263Closed
alter storefront in connection with application 02-138265. To construct frames around the door and widows to support future signs hang on top of the frames. This is NOT a sign permit HISTORICAL
Dec 4, 2002 · 85 FRONT ST E - Building permit00 349750Closed
alter plans approved under bp 00-349750 & 00-349750-01by altering basement layout, clarify details on all floor plans, plus histrical front wall restoration. HISTORICAL, (Includes 81 & 85 Front St E) changes bubbled
Nov 14, 2002 · 77 FRONT ST E - Building permit01 108342Closed
revise storm & san. drains, 8" storm & 6" san. drain layout to connect to Existing Services)No New services provided as per applicant advised)A.P.)See-PLANS------
Jul 31, 2002 · 77 FRONT ST E - Building permit02 146049Closed
install fire alarm system in connection with bp#02-113665
Jun 14, 2002 · 85 FRONT ST E - Building permit02 113665Closed
alter plans as approved under file 02 -11365 by altering sprinkler system in proposed restaurant on first floor and basement . 130 seats for Ground Flr, 56 Seats for Basement. tenant: spring roll
Jun 14, 2002 · 85 FRONT ST E - Zoning review02 130931 PSPClosedApr 29, 2002 · 81 FRONT ST E
- Building permit02 107342Cancelled
install kitchen exhaust riser
Jan 31, 2002 · 85 FRONT ST E - Zoning review01 013442 LTOClosedNov 7, 2001 · 85 FRONT ST E
- Zoning review01 013380 LTOClosedOct 24, 2001 · 77 FRONT ST E
- Consent (lot split)B091/00TOApproved
This application includes 81 and 85 Front Street East. The proposed conveyance is a "horizontal severance" for the proposed 54-unit residential condominium along with easements for mechanical, electrical and other services. Portions of the lower floor are to be conveyed for a residential lobby on the first floor and a common room and mechanical room on the basement floor. The parts to be conveyed for residential use are Parts 1 to 6 inclusive and Parts 30 & 31, as indentified on plans submitted to the Committee of Adjustment. The parts to be retained for commercial use are Parts 7 to 29 inclusive, as identified on plans submitted to the Committee of Adjustment.
Aug 22, 2000 · 77 FRONT ST E - Zoning review00 327767 000ClosedAug 14, 2000 · 77 FRONT ST E
- Building permit00 164691Closed
remoal of interior non-loadbearing partitions only, all life safety systems to remain in place and funtional. no renovation or other interior alterations included. this application includes 77-85 front st e
Jul 11, 2000 · 77 FRONT ST E - Zoning review00 012732 LTOClosedJul 7, 2000 · 77 FRONT ST E
- Zoning review00 158975 000ClosedJun 6, 2000 · 77 FRONT ST E
- Building permit00 158966Cancelled
Make interior alterations to 2nd floor
Jun 6, 2000 · 77 FRONT ST E - Building permit99 108084Closed
Install shoring to faciliate brick repair on part of bldg. face. Hold for Structural Engineer Field Review Memo + Owner's Commit Form
Nov 23, 1999 · 81 FRONT ST E - Building permit99 017640Closed
SUPPLY AND INSTALL NEW H.V.A.C. SYSTEM TO EXISTING SEE BLDG APPL # 426811 JNB
Oct 13, 1999 · 77 FRONT ST E - Building permit99 017639Closed
MAKE INTERIOR INTERIOR ALTERATIONS TO 1ST FLOOR OF BUILDING FOR RESTAURANT PURPOSES AND ALTER STOREFRONT. "OCCUP. LOAD=30 TENANT: MARKET EATERY JNB DESIGNATED HIST. HOLD FOR HLTH APP.
Oct 13, 1999 · 77 FRONT ST E - Building permit98 024983Closed
MAKE INTERIOR ALTERATIONS. SEE STATEMENT OF UNDERTAKING. FEE $10000
Dec 10, 1998 · 77 FRONT ST E - Building permit98 021830Cancelled
REPAIR BRICK WALL AT FRONT OF BUILDINGS HOLD FOR SURVEY APPROVAL (W24)/SP
Sep 23, 1998 · 77 FRONT ST E - Zoning review98 025940 LTOClosedApr 3, 1998 · 77 FRONT ST E
- Building permit96 016638Closed
MAKE INTERIOR ALTERATIONS BY MAKING STRUCTURAL MODIFICATIONS. AT GROUND FLOOR AND BASEMENT ONLY
Aug 26, 1996 · 77 FRONT ST E - Zoning review96 024593 LTOClosedFeb 14, 1996 · 81 FRONT ST E
- Zoning review91 026773 LTOClosedJul 31, 1991 · 85 FRONT ST E
- Zoning review91 026629 LTOClosedJun 21, 1991 · 77 FRONT ST E
- Zoning review91 026568 LTOClosedJun 6, 1991 · 81 FRONT ST E
- Zoning review91 026082 LTOClosedFeb 11, 1991 · 85 FRONT ST E
- Zoning review88 030626 LTOClosedSep 6, 1988 · 81 FRONT ST E
- Zoning review86 027842 LTOClosedFeb 11, 1986 · 81 FRONT ST E
- Zoning review84 026909 LTOClosedOct 17, 1984 · 77 FRONT ST E
- Zoning review84 026797 LTOClosedAug 24, 1984 · 81 FRONT ST E
- Zoning review82 026214 LTOClosedJun 25, 1982 · 85 FRONT ST E
Check before you build
Site-specific exception 900.11.10(2109)
Needs a closer look2 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Older by-law A
Section 12(2) 132 of former City of Toronto By-law 438-86
- Older by-law B
Section 12(2) 260 of former City of Toronto By-law 438-86.
Lot facts
- Area
- 1,318 m²
- Frontage
- 29 mestimated, irregular lot
- Depth
- 61.3 mestimated, irregular lot
- Street
- Market St
- Corner lot
- Yes, also on Front St E61.3 m along it
- Public lane
- None
- Max height
- 23 m
- Max lot coverage
- —
- Major Transit Station Area: King. The lot is inside the King Major Transit Station Area approved by the Province (Site and Area Specific Policy 606). Source
- Downtown Plan Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Priority retail street: Front Street East, Market Street. The lot is on a priority retail street. In this zone at least 60% of the ground floor along that street must hold retail, restaurants, offices or similar uses, with entrances within 5 m of the lot line and 60% of the ground floor wall in windows or doors. Source
- Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
- Zone CR 4.0 (c3.0; r4.0) SS1 (x2109) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
- 10 City trees in front of this lot. The City's street tree inventory lists 10 trees at this address: honey locust (20 cm), honey locust (20 cm), honey locust (18 cm). Diameter is the trunk at breast height. Source
Around this lot
- Minor variances approved
- 100%5 of 5 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 0
- Development applications
- 12
Within 300 m, last 10 years. 0 suite and multiplex permits: no more than at most Toronto houses (median 3). 5 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To permit a reduction in the number of required resident parking spaces and nine obstructed parking spaces, on-site.
89 CHURCH ST · Jan 15, 2025 · 429 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 552-2019(LPAT)), for the existing four-storey commercial/office building, by permitting the dwelling unit use through the conversion of the second and third storeys from commercial/offices uses into residential dwelling units (live/work units). Also, to permit a new residential lobby, facing King Street East. No visitor parking spaces and accessible parking spaces will be provided on-site. There will be a total of three commercial units and 11 residential dwelling units (7 dwelling units and 1 commercial unit on the second level, and 4 dwelling units and 2 commercial units on the third level) within this mixed-use building.
71 KING ST E · Dec 11, 2024 · 248 m away - Minor varianceApproved
To permit the reduction of residential parking spaces and types, residential amenity space provided, and tower heights to the 85 ,78, and 70-storey buildings, currently under review by Site Plan Control Application (File Number 20 19218252 STE 10 SA). There will be a total of 2,640 residential dwelling units (with 188 affordable units) within this block (Block4).
55 LAKE SHORE BLVD E · Oct 23, 2024 · 447 m away - Minor varianceApproved
To alter the development standards for the 33-storey mixed-use building (approved under Site Specific Zoning By-Law 1195-2022), by converting the required office use space into hotel use space (for 142 hotel suites and related facilities) on floors 1 through 10. The site is subject to a current Site Plan Control Application (File 2017 235087 STE 28 SA).
34 KING ST E · Sep 25, 2024 · 352 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 702-2021(OLT), as amended by City Wide Zoning By-law 569-2013), which include an increase to the overall tower height (from 45-storeys to 48-storeys) and total gross floor area, and a reduction of parking spaces, amenity space, and number of two or more bedrooms, for the approved mixed-use building (currently under construction).
114 CHURCH ST · Dec 6, 2023 · 441 m away
Latest activity nearby
- Zoning review
Application On Hold
91 FRONT ST E · Nov 24, 2026 · 67 m away - Building permit
Proposal for interior alteration to existing office suites 208, 216, 230 and 306
56 THE ESPLANADE · Nov 23, 2026 · 205 m away - Building permit
Revision 01 - due site conditions and landlord repairsProposed interior alterations and repairs due to fire damage.
47 COLBORNE ST · Nov 9, 2026 · 197 m away - Building permit
UNIT 301 INTERIOR NON-STRUCTURAL PARTITION DEMOLITION
47 COLBORNE ST · Nov 6, 2026 · 197 m away - Building permit
REV 01: Revision to permit to combine the two existing all gender washrooms into oneProposal for interior alterations for tenant fit out to existing unit. Unit 300
41 FRONT ST E · Nov 6, 2026 · 184 m away - Building permit
REVISION- 03Rev 02 - Scope clarified and simplified for future tenant (Back to Base project with plumbing rough-ins). Build out of future space by others (under separate future permit).REVISION 01:Interior alterations - back to base building - group A occupancy
71 FRONT ST E · Nov 5, 2026 · 48 m away - Building permit
Proposal for iInterior alterations to a group D office building - UNIT 400
47 COLBORNE ST · Nov 4, 2026 · 197 m away - Building permit
Proposal for maglock permit adding maglocks to existing patio doors
65 KING ST E · Nov 4, 2026 · 255 m away - Building permit
Interior alterations to and existing office. - Unit 307 - Allied
47 COLBORNE ST · Nov 3, 2026 · 197 m away - Building permit
Revision 01: revision to permit 25-138538 BLD 00 BA to revise layout.Convert the existing gym to a retail store - DollaramaConvenience address is 98 The Esplanade
71 FRONT ST E · Nov 3, 2026 · 48 m away
Neighbourhood: St Lawrence-East Bayfront-The Islands
About the area around the lot, not the lot itself.
- Nearest station
- King Station7 min walk
- Nearest TTC stop
- Church St at The Esplanade2 min walk
- Nearest cycling route
- The EsplanadeBi-Directional Cycle Track, 2 min walk
- Nearest traffic count
- 6,113 vehicles in 8 hFront St E / Market St, 60 m away, Mar 24, 2022
- Serious collisions within 500 m
- 122021–2026, killed or seriously injured: 4 fatal, 6 with pedestrians, 4 with cyclists
- Parks
- Market Lane Park1 min walk
- Toronto Sculpture Garden2 min walk
- David Crombie Park2 min walk
Schools within 1 km
- DOWNTOWN ALTERNATIVE SCHOOL English Public 3 min walk
- ST MICHAEL CATHOLIC ELEMENTARY SCHOOL - BLDG 1 English Separate 4 min walk
- GEORGE BROWN COLLEGE - ST JAMES CAMPUS College 5 min walk
- KEYSTONE INTERNATIONAL SCHOOLS Private 6 min walk
- VICTORIA STREET LINC English Public 8 min walk
- MARKET LANE JR & SR PUBLIC SCHOOL English Public 10 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | St Lawrence-East Bayfront-The Islands | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $87,000 | $84,500 |
| Households that own their home | 40% | 54% |
| Population (2021) | 31,285 | 16,813 |
| Homes built in 1960 or before | 3% | 29% |
| Homes needing major repairs | 3% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | St Lawrence-East Bayfront-The Islands | City median |
|---|---|---|
| Assault | 1059.7 | 636.3 |
| Robbery | 96.3 | 69.5 |
| Shootings | 4.5 | 10.5 |
| Auto theft | 24.6 | 192.6 |
| Theft over $5,000 | 78.4 | 46.1 |
| Break and enter | 163.5 | 172.8 |
| Theft from vehicles | 163.5 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.