Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
15 development applications open within 300 m
Good to know15 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 94 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
14 records on file: more than at 100% of Toronto houses (median 0).
- Development application21 227654 STE 11 CDClosed
Draft Plan of Standard Condominium for 202 units, 22 residential parking spaces and 12 service units
Oct 19, 2021 · 767 YONGE ST · City file - Development application19 265064 STE 11 SAClosed
Site Plan Approval for a 25-storey mixed-use building.
Dec 27, 2019 · 767 YONGE ST · City file - Development application16 118667 STE 27 OZClosed
A 25-storey (81.7 metres including a mechanical penthouse) mixed-use building with retail uses on the ground floor and residential uses above at 767-773 Yonge Street. The proposal has a Floor Space Index of 14 times the area of the lot and a total of 202 residential units, 203 bicycle parking spaces and 22 vehicle parking spaces. The proposal proposes to concerve and alter the 3-storey heritage building at 771-773 Yonge Street.
Feb 19, 2016 · 767 YONGE ST · City file - Building permit14 262989Closed
To complete interior alterations to the existing 2nd floor for office of "ILAC" ESL school in the existing multi-use building.
Feb 12, 2015 · 767 YONGE ST - Building permit14 233303Closed
Proposal for minor plumbing changes to "Tim Hortons"
Nov 5, 2014 · 769 YONGE ST - Building permit14 233291Closed
Proposal for minor HVAC changes to "Tim Hortons"
Nov 3, 2014 · 769 YONGE ST - Building permit08 148993Cancelled
Convert existing 2nd floor Internet Cafe into Management Office (changed Place of Worship by drawings received 13/5/08)
Jul 17, 2008 · 767 YONGE ST - Zoning review06 113496 LTOClosedMar 1, 2006 · 767 YONGE ST
Show 6 older records
- Building permit01 150090Closed
Alter HVAC system on ground floor restaurant (55 seats). Cost Incl: 01-150074 Tenant: Tim Hortons (work is being done at 769 Yonge St)
Jul 17, 2001 · 767 YONGE ST - Building permit01 150074Closed
Interior alterations to ground floor for restaurant (55 seats) use.Tenant: Tim Hortons (work is being done at 769 Yonge St) Survey Approved.
Jul 17, 2001 · 767 YONGE ST - Zoning review01 153368 000ClosedJun 28, 2001 · 767 YONGE ST
- Building permit01 150096Closed
Install plumbing fixtures in ground floor restaurant (55 seats) and basement: Basement: 2 WB, 2 WC; Ground Floor: 3 KS, 1 3-com KS, 3 Bar Sinks, 2 Dishwasher, 2 WB, 2 Mop Sinks, 3 WC, 2 Urinal and 7 FD.1 grease interceptor.install 4"drain) Cost Incl: 01-150074 Tenant: Tim Hortons (work is being done at 769 Yonge St)
Jun 25, 2001 · 767 YONGE ST - Zoning review94 025730 LTOClosedDec 15, 1994 · 767 YONGE ST
- Zoning review84 026277 LTOClosedMar 20, 1984 · 767 YONGE ST
Check before you build
Site-specific exception 900.11.10(220)
Needs a closer look25 site-specific rules apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
On 767, 769, 771 and 773 Yonge Street, if the requirements in Section 6 and Schedule 1 of By-law 321-2020(LPAT) are complied with, a building or structure may be constructed in compliance with regulations
- Rule B
to (Y) below; (B) Despite regulations 40.10.40.40(1) and (2), the permitted maximum gross floor area of all buildings and structures will be 13,900 square metres
- Rule C
A minimum of ten percent of the total number of dwelling units must contain three or more bedrooms
- Rule D
Regulation 40.10.40.1, with respect to the location of residential use portions of the building does not apply, except that no dwelling units may be located in the first storey of the building
- Rule E
Despite regulations 40.5.40.10(1) and (2), the height of a building or structure is measured from the Canadian Geodetic Datum elevation of 116.05 metres to the highest point of a building or structure
- Rule F
Despite regulation 40.10.40.10(1), the height of any building or structure may not exceed the height limit of the numbers following the symbol HT on Diagram 3 of By-law 321-2020(LPAT)
- Rule G
Despite (F) above, as well as regulations 40.5.40.10(6) and (7), the following elements or portion of any building or structure may project above the height indicated by the numbers following the symbol HT on Diagram 3 of By-law 321-2020(LPAT): (i) architectural features, ornamental elements, parapets, trellises, pergolas, lighting fixtures, lightning rods, window washing equipment, and unenclosed structures providing safety or wind protection to rooftop amenity space , all of which may project up to a maximum of 3.0 metres; (ii) screens and partitions, which may project to a maximum of 2.5 metres; (iii) landscape planters and elements of a green roof , which may project to a maximum of 2.0 metres; and (iv) roof topping and finishes, railings and balustrades, which may project to a maximum of 1.0 metres
- Rule H
Despite regulation 40.5.40.10(5)(A), the total area of all equipment, structures , or parts of a building may cover no more than 85 percent of the area of the roof, measured horizontally
- Rule I
Despite regulation 40.5.40.10(5)(B), if any equipment, structures , or parts of a building are located within 6.0 metres of a lot line abutting a street, their total horizontal dimension, measured parallel to the street , may not exceed 85 percent of the width of the building's main walls facing that street
- Rule J
Despite regulation 40.5.40.10(6), unenclosed structures providing safety or wind protection to rooftop amenity space and that are located closer than 2.0 metres from the interior face of any main wall may also be permitted to exceed the maximum permitted height by 3.0 metres
- Rule K
Despite regulation 40.5.40.10(4) and subject to (H), (I) and (J) above, elevator shafts, window washing equipment and mechanical equipment used for the functional operation of the building may exceed the permitted maximum height of the building by 6.0 metres
- Rule L
Despite regulations 40.5.40.70(1) and 40.10.40.70(1), the required minimum building setbacks are shown on Diagram 3 of By-law 321-2020(LPAT)
- Rule M
Regulation 40.10.40.10(5) with respect to the minimum height of the first storey does not apply
- Rule N
Despite (I) above, and regulations 5.10.40.70(1), 40.10.40.60(1), (2), (3), (6), the following are permitted to encroach into the required minimum building setbacks on Diagram 3 attached to and forming part of this By-law: (i) balconies, canopies, window projections, window washing equipment, patios and awnings may encroach up to a maximum of 1.8 metres; (ii) lighting fixtures may encroach to a maximum of 1.0 metres; and (iii) ramps, stairs, stair enclosures, and servicing areas and associated structures and elements required for the functional operation of the building
- Rule O
The south face of a building must not have any transparent glazing above a height of 14.0 metres
- Rule P
Despite regulation 40.10.40.80(2), if a building has main walls where a line projected outward at a right angle from one of the main walls intercepts another main wall of the same building , the required minimum aboveground separation distance between those main walls , excluding architectural recesses in a main wall and main walls around inset balconies and entrances, is: (i) a minimum of 3.0 metres if there are no windows in one or both of those main walls ; and (ii) a minimum of 6.0 metres if each main wall has windows
- Rule Q
Despite regulations 40.10.40.50(1) and (2), amenity space must be provided and maintained in accordance with the following: (i) a minimum of 270 square metres of indoor amenity space , which may be shared with non-residential uses; (ii) a minimum of 135 square metres of outdoor amenity space , which may be shared with non-residential uses; (iii) the indoor amenity space may be provided in multipurpose rooms which are not contiguous; and (iv) no amenity space is required for non-residential uses of the building
- Rule R
Despite regulation 200.5.10.1(1) and Table 200.5.10.1, parking spaces must be provided and maintained in accordance with the following: (i) a minimum of 22 parking spaces for residents of the building ; and (ii) no parking spaces are required for visitors or non-residential uses
- Rule S
Despite regulations 200.15.1(1) and 200.15.10(1), a minimum of 2 accessible parking spaces must be provided and maintained in accordance with the following dimensional requirements: (i) a minimum length of 5.6 metres; (ii) a minimum width of 3.4 metres; (iii) a minimum vertical clearance of 2.1 metres; and (iv) the entire length must be adjacent to a 1.5 metre wide accessible barrier free aisle or path
- Rule T
Regulations 200.15.1(4) and 200.15.1.5(1), with respect to the location of the accessible parking spaces , do not apply
- Rule U
Despite regulation 200.5.1.10(12), the vehicle entrance and exit to the building must be at least 1.0 metres from the lot line abutting the street
- Rule V
Despite regulation 200.5.1.10(13), access to a parking space may be provided by motor vehicle elevators, provided a minimum of two (2) motor vehicle elevators are provided and maintained in the building for the use of residents
- Rule W
Despite regulation 230.5.1.10(4)(A) and (C), a bicycle parking space must comply with the following: (i) for a staked bicycle parking space , a minimum length of 1.6 metres, a minimum width of 0.45 metres and a minimum vertical clearance of 1.0 metres; (ii) for a bicycle parking space that is not a stacked bicycle parking space , a minimum length of 1.6 metres, a minimum width of 0.45 metres and a minimum vertical clearance of 1.9 metres
- Rule X
Despite regulations 230.5.10.1(10), 230.40.1.20(1) and (2), a "long-term" and "short-term" bicycle parking space may be located in a stacked bicycle parking space , which may be located within a secure room below ground or within the building
- Rule Y
Despite regulations 220.5.10.1(2), (3), (4), (5), (6), (8), a minimum of one Type "G" loading space must be provided and maintained.
Lot facts
- Area
- 788 m²
- Frontage
- 21.8 mestimated, irregular lot
- Depth
- 44.1 mestimated, irregular lot
- Street
- Yonge St
- Corner lot
- Yes, also on Asquith Ave44.1 m along it
- Public lane
- None
- Max height
- 61 m
- Max lot coverage
- —
- Site and Area Specific Policy 211, 225. The Official Plan has a policy for this site or area that varies the general rules. Read it before relying on zoning alone. Source
- Major Transit Station Area: Bloor-Yonge. The lot is inside the Bloor-Yonge Major Transit Station Area approved by the Province (Site and Area Specific Policy 600). Source
- Downtown Plan Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Priority retail street: Yonge Street. The lot is on a priority retail street. In this zone at least 60% of the ground floor along that street must hold retail, restaurants, offices or similar uses, with entrances within 5 m of the lot line and 60% of the ground floor wall in windows or doors. Source
- Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
- Zone CR 7.8 (c4.5; r7.8) SS1 (x220) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
Around this lot
- Minor variances approved
- 93%25 of 27 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 1
- Development applications
- 37
Within 300 m, last 10 years. 1 suite and multiplex permits: no more than at most Toronto houses (median 3). 27 variance decisions: more than at 59% of Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceRefused
To alter the development standards, as approved under Site Specific Zoning By-laws 22769 and 325-82, for the existing 27-storey mixed-use building by reducing the building setbacks, increasing the residential dwelling units from 479 to 495 units, increasing the total gross floor area, and reducing the total amenity space. This application is subject to a Site Plan Control application, which has not yet been submitted by the applicant.
235 BLOOR ST E · Nov 4, 2026 · 465 m away - Minor varianceApproved
To alter the development standards for the mixed-use development (approved a northern building height of 35-storeys (124.5 m) under Site Specific Zoning By-law 302-2023), and increased to 39-storeys (135.5 m as approved under Minor Variance Decision A0018/24TEY), by further increasing the northern building height to 44-storeys (142.75 m, excluding the mechanical penthouse) inclusive of an 11-storey podium base building (38.65 m), increasing the maximum gross floor area, residential gross floor area, and reducing the outdoor amenity spaces. Also, the existing 10-storey office building (located at the southern limits of this subject site) will be maintained and unaltered. There will be a total of 329 residential dwelling units on this lot.
1235 BAY ST · Oct 14, 2026 · 242 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-Law 697-2021(OLT), for a new 50-storey mixed-use building (as approved under Committee of Adjustment Files A0612/23TEY and A0231/25TEY), by increasing the maximum total gross floor area, maximum building height (60.2 m to 61.25 m at the east side portion of the building), altering the minimum building setbacks, and reducing the required bicycle parking spaces. There will be a total of 267 residential dwelling units on this lot.
874 YONGE ST · Aug 5, 2026 · 174 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 1050-2015) for the 68-storey mixed-use building (north-east Tower) by increasing the building height from 215 m to 218.6 m (including the height of the mechanical penthouse). Also, to reduce the total number of commercial parking spaces (managed by the Toronto Parking Authority) from 800 to 795 within Parking Levels 1 to 6 (with five parking spaces located on the south-east portion of Parking Level 6 being converted into car wash bays). The existing 196 residential parking spaces on Parking Levels 3 and 4 will be maintained and unaltered.
27-29 YORKVILLE AVE · Jul 15, 2026 · 175 m away - Minor varianceApproved
To alter the existing residential dwelling unit by converting it into two separate residential dwelling units (occupying the second and third storeys of the existing three-storey mixed-use building). Also, to extend the existing commercial unit (currently occupying the ground floor) into the basement.
106 SCOLLARD ST · Jun 10, 2026 · 466 m away
Latest activity nearby
- Zoning review
Application Acceptable
12 CUMBERLAND ST · Nov 24, 2026 · 105 m away - Building permit
1 wall sign + 1 projecting sign***HELLO NORI***
1250 BAY ST · Nov 24, 2026 · 286 m away - Building permit
Installation of new vertical condensate drain risers to collect condensate from existing piping outlets at the balconies.
40 ASQUITH AVE · Nov 20, 2026 · 143 m away - Building permit
6 overhanging structure signs**AEVUM**
11 YORKVILLE AVE · Nov 19, 2026 · 135 m away - Building permit
Proposal for new Sprinklers System on the 3rd floor public corridor.
60 BLOOR ST W · Nov 19, 2026 · 230 m away - Building permit
Proposed interior alterations to an existing office
2 BLOOR ST E · Nov 18, 2026 · 104 m away - Building permit
Proposal for interior alterations to an existing office.
2 BLOOR ST E · Nov 17, 2026 · 104 m away - Building permit
INTERIOR RENOVATION OF AN EXISTING CONDO SUITE IN EXISTING CONDOMINIUM - UNIT 4802
50 YORKVILLE AVE · Nov 16, 2026 · 214 m away - Zoning review
Not Started
12 CUMBERLAND ST · Nov 12, 2026 · 105 m away - Building permit
Proposal for interior alterations to an existing office space
121 BLOOR ST E · Nov 10, 2026 · 236 m away
Neighbourhood: Rosedale-Moore Park
About the area around the lot, not the lot itself.
- Nearest station
- Yonge Station1 min walk
- Nearest TTC stop
- Yonge Station - Westbound Platform1 min walk
- Nearest cycling route
- Yonge StCycle Track, 1 min walk
- Nearest traffic count
- 7,497 vehicles in 8 hYonge St / Asquith Ave, 40 m away, Nov 22, 2018
- Serious collisions within 500 m
- 92021–2026, killed or seriously injured: 0 fatal, 2 with pedestrians, 3 with cyclists
- Parks
- Town Hall Square2 min walk
- Harold Town Park2 min walk
- Asquith Green Park3 min walk
Schools within 1 km
- HUMBER COLLEGE - INTERNATIONAL GRADUATE SCHOOL College 4 min walk
- MCDONALD INTERNATIONAL ACADEMY SCHOOL Private 6 min walk
- JESSE KETCHUM JR & SR PUBLIC SCHOOL English Public 8 min walk
- ROSEDALE DAY SCHOOL Private 9 min walk
- CAREER QUEST - TORONTO Private 9 min walk
- THE ABELARD CENTRE FOR EDUCATION Private 10 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Rosedale-Moore Park | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $122,000 | $84,500 |
| Households that own their home | 58% | 54% |
| Population (2021) | 20,080 | 16,813 |
| Homes built in 1960 or before | 46% | 29% |
| Homes needing major repairs | 6% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Rosedale-Moore Park | City median |
|---|---|---|
| Assault | 1080.4 | 636.3 |
| Robbery | 86.8 | 69.5 |
| Auto theft | 199.6 | 192.6 |
| Theft over $5,000 | 65.1 | 46.1 |
| Break and enter | 455.6 | 172.8 |
| Theft from vehicles | 182.2 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.