Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
Cultural Heritage Evaluation Report required
Needs a closer lookThis property is listed under Official Plan Amendment 720: a heritage evaluation is needed before redevelopment.
What it means. Plans to tear down or rebuild will need a heritage evaluation first.
How to confirm. Heritage Planning at the City confirms the status. Details
Official Plan Amendment 7203 building permits open, the oldest since 2011
Needs a closer lookStill open in the City's records: 24 174774 (IProposal fo installation of new air conditioning units for cooling centre in library, 2024, status Inspection); 15 142462 (Proposal to install a new fire alarm system, paging system and emergency lighting retro..., 2015, status Inspection); 11 291688 (Proposal to install one backflow prevention device in existing highschool "St Joseph's..., 2011, status Permit Issued).
What it means. An open permit can mean work that was never finished or never passed final inspection. After closing, finishing it or closing the file can fall to you.
How to confirm. Ask the seller for the final inspection records. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016)1 Committee of Adjustment file on this lot
Good to know1 approved. B0092/08TEY (To create an easement in favour of 90 Wellesley Street West for the purpose of steam wa..., 2008).
What it means. Approved variances and consents stay with the property, including any conditions in the decision. They allow what was approved, not more.
How to confirm. Decisions are in the Application Information Centre; older files are available from the Committee of Adjustment office. Details
City of Toronto, Committee of Adjustment applications (2001 onwards)1 development application open within 300 m
Good to know1 rezoning, site plan, subdivision or condominium application within 300 m, submitted in the last 10 years, is not closed yet, including buildings of up to 40 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
11 records on file: more than at 99% of Toronto houses (median 0).
- Building permit24 174774Inspection
IProposal fo installation of new air conditioning units for cooling centre in library
Jul 31, 2024 · 74 WELLESLEY ST W - Zoning review22 112336 LPRClosedFeb 9, 2022 · 74 WELLESLEY ST W
- Development application16 221931 STE 20 OZClosed
Official Plan Amendment application to establish a new University of Toronto St. George Campus Secondary Plan that would replace the existing University of Toronto Secondary Plan.
Sep 13, 2016 · 74 WELLESLEY ST W · City file - Building permit15 142462Inspection
Proposal to install a new fire alarm system, paging system and emergency lighting retrofit in the existing secondary school.
Apr 28, 2015 · 74 WELLESLEY ST W - Building permit11 291688Permit Issued
Proposal to install one backflow prevention device in existing highschool "St Joseph's College".
Oct 24, 2011 · 74 WELLESLEY ST W - Building permit10 232488Closed
REVISION - to add and remove partition walls.HVAC - permit for interior alterations to existing secondary school. floor 4. St Joseph College.
Aug 24, 2011 · 74 WELLESLEY ST W - Building permit10 258654Closed
To erect and display one ground sign containing readograph copy and identifying a school. **St. Joseph's College School**
Oct 29, 2010 · 74 WELLESLEY ST W - Building permit10 219687Closed
Interior alterations to existing gymnasium on ground floor, including smoke detection to existing stage. Resurfacing to roof and additional roof drains to gymnasium area only. St. Josephs College School.
Aug 19, 2010 · 74 WELLESLEY ST W
Show 3 older records
- Consent (lot split)B0092/08TEYApproved
To create an easement in favour of 90 Wellesley Street West for the purpose of steam water services from 74 Wellesley Street West to 90 Wellesley Street West, together with right of access and repair in favour of the owners/occupants of 90 Wellesley Street West. Easement - Parts 7 and 9, Plann 66R-23430 74 Wellesley Street West Part 7 and 9 have a combined area of 51.6 m2 and will be used for steam water services from 74 Wellesley Street West to 90 Wellesley Street West, together with right of access and repair in favour of the owners/occupants of 90 Wellesley Street West .
Jul 9, 2008 · 74 WELLESLEY ST W - Zoning review07 276101 LTOClosedNov 5, 2007 · 74 WELLESLEY ST W
- Zoning review83 026385 LTOClosedOct 31, 1983 · 74 WELLESLEY ST W
Check before you build
Zoning not in By-law 569-2013
Needs a closer lookThis lot is not covered by the citywide zoning by-law's map. It is probably still governed by a former municipal by-law, which this tool does not read yet.
Zoning By-law 569-2013
Lot facts
- Area
- 4,484 m²
- Frontage
- 74.4 m
- Depth
- 60.8 m
- Street
- Wellesley St W
- Corner lot
- No
- Public lane
- St Basil Lane, 74 m along it
- House footprint
- 2,354 m²roof up to 26.8 m
- Back yard
- 7.5 mhouse to rear lot line
- Side yards
- 11.1 m and 11.1 mhouse to side lot lines
- Buildings on the lot
- 2house, garage, sheds
- Max height
- —
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
Around this lot
- Minor variances approved
- 100%7 of 7 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 0
- Development applications
- 8
Within 300 m, last 10 years. 0 suite and multiplex permits: no more than at most Toronto houses (median 3). 7 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 88-2023(OLT)) for the 40-storey mixed-use building (which is currently under construction), by increasing the residential gross floor area, building height (41-storeys; 123.5 m to 127.6 m and 129.2 m to 133.6 m), and the height of the elevator overrun projection. There will be a total of 516 residential dwelling units on this site.
20 MAITLAND ST · Apr 1, 2026 · 468 m away - Minor varianceApproved
To alter the development standards for the previously approved 32-storey and 46-storey, two-tower mixed-use, purpose built rental development with 30 Percent affordable dwelling units and a child care center (approved under Site Specific Zoning By-law 1096-2021), by redistributing the building heights to 33 and 41storeys, increasing podium setbacks, reducing street wall heights, reducing the size of podium to create two separate buildings connected only below grade, decreasing the amount of indoor amenity space, reducing the number of two or more bedroom units, eliminating the resident and non-residential parking requirements, and decreasing the amount of residential visitor spaces. Site plan control application 19 127591 STE 13 SA is under review.
27 GROSVENOR ST · Jul 30, 2025 · 357 m away - Minor varianceApproved
To alter the development standards for the 40-storey mixed-use building (as approved under Site Specific Zoning By-law 88-2023) by increasing the total number of residential dwelling units, the overall and residential gross floor area, the building height, and the maximum projection height of an elevator overrun. Also, to reduce the total number of residential dwelling units with 3 or more bedrooms, the required amenity space, and the total number of residential visitor parking spaces. The new 45-storey mixed-use building (excluding the mechanical penthouse) will have a total of 572 residential dwelling units, 78 residential parking spaces, and 7 residential visitor parking spaces. This is currently undergoing Site Plan Control (Application Number 19 240163 STE 13 SA).
26 MAITLAND ST · Apr 23, 2025 · 487 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 193-2024(OLT)), for a new 59-storey mixed-use building, by permitting a private student residence use on this lot. There will be a total of 587 residential dwelling units within this building.
510 YONGE ST · Mar 19, 2025 · 390 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-Law 1422-2017), for the 40-storey mixed-use building by: increasing the podium height (from 3-storeys to 6-storeys); and altering building setbacks (in order to consolidate the non-residential institutional uses within the podium). No changes to the tower or residential uses are proposed. Also, to reduce the minimum required number of parking spaces for institutional uses (from 11 parking spaces to 5 parking spaces), which will be located within underground parking level P1.
70 ST MARY ST · Feb 26, 2025 · 348 m away
Latest activity nearby
- Zoning review
Application Acceptable
95 ST JOSEPH ST · Nov 24, 2026 · 95 m away - Building permit
Proposed Hydro Vault Repairs
1001 BAY ST · Nov 13, 2026 · 188 m away - Building permit
Rev 01 - Proposed alterations to sprinkler system leve 3-14Proposal for sprinkler.
900 BAY ST · Nov 12, 2026 · 135 m away - Building permit
Proposal for sprinklers for Hearst Tower Level 8-11.
900 BAY ST · Nov 10, 2026 · 135 m away - Building permit
Proposal for sprinklers for Hepburn Tower Level 3-7.
900 BAY ST · Nov 10, 2026 · 135 m away - Building permit
Proposed interior alterations for dental office
16 WELLESLEY ST W · Nov 10, 2026 · 281 m away - Building permit
Proposed interior alteration at second, third, fifth and sixth floor to convert the property from office building to mixed-use building; Proposed: 10 residential units, 1 wellness studio and 5 officesExisting: 1 wellness studio at first floor and 1 office at fourth floor
9 ST NICHOLAS ST · Nov 9, 2026 · 293 m away - Building permit
Proposal for sprinklers for Hearst Tower Level 8-10.
900 BAY ST · Nov 9, 2026 · 135 m away - Building permit
Proposal for sprinklers for Hearst Tower Level 3-7.
900 BAY ST · Nov 9, 2026 · 135 m away - Building permit
REV 01: Fire separation revision of B2 level, interior alteration to B1 tenant storage area, Ground Floor 900 Bay Lobby layout revision.Proposed interior alterations - interior fit-out for following areas; Ground Floor 900 bay lobby (addition of 2 Security Desks, Secured Glazing and Turnstiles), 2nd floor Hearst lobby (to add relocated Conference Reception Desk), Basement 2 (addition of Pallet scanner and Parcel scanner area), and Basement 1( addition of 25 chain-link cages at Tenant Storage Room B1-042)
900 BAY ST · Nov 5, 2026 · 135 m away
Neighbourhood: Bay-Cloverhill
About the area around the lot, not the lot itself.
- Nearest station
- Wellesley Station7 min walk
- Nearest TTC stop
- Wellesley St West at Bay St2 min walk
- Nearest cycling route
- Wellesley St WCycle Track, 1 min walk
- Nearest traffic count
- 13,053 vehicles in 8 hBay St / Wellesley St W, 130 m away, Jun 21, 2023
- Serious collisions within 500 m
- 82021–2026, killed or seriously injured: 1 fatal, 4 with pedestrians, 1 with cyclists
- Parks
- Clover Hill Park2 min walk
- Queen's Park3 min walk
- Dr. Lillian McGregor Park3 min walk
Schools within 1 km
- ST JOSEPH'S COLLEGE SCHOOL English Separate 1 min walk
- TORONTO SCHOOL OF THEOLOGY - U OF T, BLDG 434 University 2 min walk
- THE YMCA ACADEMY SECONDARY SCHOOL Private 5 min walk
- ROSEDALE DAY SCHOOL Private 9 min walk
- MUNK SCHOOL OF GLOBAL AFFAIRS GRAHAM LIBRARY - U OF T, BLDG 12C University 10 min walk
- MUNK SCHOOL OF GLOBAL AFFAIRS AT TRINITY - U OF T, BLDG 12A University 10 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Bay-Cloverhill | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $58,400 | $84,500 |
| Households that own their home | 30% | 54% |
| Population (2021) | 16,670 | 16,813 |
| Homes built in 1960 or before | 4% | 29% |
| Homes needing major repairs | 3% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Bay-Cloverhill | City median |
|---|---|---|
| Assault | 601.9 | 636.3 |
| Robbery | 74.7 | 69.5 |
| Auto theft | 16.6 | 192.6 |
| Theft over $5,000 | 87.2 | 46.1 |
| Break and enter | 286.4 | 172.8 |
| Theft from vehicles | 145.3 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.