Commercial residential · CR 0.6 (c0.0; r0.6) SS2 (x695)32.6 × 40.2 m1,302 m²on Heath St E

Not a single house

A rental apartment building

The City's RentSafeTO program evaluates this building as a rental apartment building (three storeys and ten units or more). Build options for a house do not apply.

Looking at a house nearby? What this means for you

  • 3 storeys, 30 rental units, built 1946More people, cars and deliveries than a street of houses alone. A tall building also shades the lots to its north.
  • Permits or applications open on this parcelRecent records on this lot: 26 185667 STE 12 SA (Mixed use development consisting of three towers organized around a central publicly ac..., 2026); 21 226522 STE 12 SB (Draft Plan of Subdivision for 4 blocks, 2021); 19 134851 STE 12 OZ (Application to amend the Official Plan and Zoning By-law to permit a mixed-use developm..., 2019). Larger work can mean noise and trucks next door; read what each one is for.
  • 12 development applications open within 300 m, up to 49 storeysNew buildings may go up around here in the next years. More change nearby than at 97% of Toronto houses.
  • City upkeep score: 93 out of 100RentSafeTO rates common areas, building systems and records. A low score can show from the street.
  • Major Transit Station Area: St ClairThe City plans more homes around the station: good for transit, and more building over time.

Want to check this building before you buy?

We are building checks for apartment buildings. Leave your email and we will tell you when it is ready.

N20 m
32.6 m frontage40.2 m deep

Before you offer

From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.

  • 10 by-law investigations closed in the last two years

    Good to know

    Closed files (Adequate Heat, Order Issued Property Standards, Property Standards, Zoning): 26 199957 PRS 00 IR (Property Standards, 2026); 26 172585 000 00 IR (Adequate Heat, 2026); 26 172584 000 00 IR (Property Standards, 2026); and 7 more.

    What it means. Someone raised an issue here and the City closed the file. Ask the seller what it was about.

    City of Toronto, Toronto Building orders and Municipal Licensing and Standards investigations
  • Work or applications in progress

    Good to know

    Recent records on this lot: 26 185667 STE 12 SA (Mixed use development consisting of three towers organized around a central publicly ac..., 2026); 21 226522 STE 12 SB (Draft Plan of Subdivision for 4 blocks, 2021); 19 134851 STE 12 OZ (Application to amend the Official Plan and Zoning By-law to permit a mixed-use developm..., 2019).

    What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.

    How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details

    City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications
  • 12 development applications open within 300 m

    Good to know

    12 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 49 storeys. They are listed under Around this lot.

    What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.

    How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details

    City of Toronto, Development Applications
  • Rental building evaluation: 93 out of 100

    Good to know

    The City's RentSafeTO program evaluated this rental building in 2026 (3 storeys, 30 units, built 1946).

    What it means. The score covers common areas, building systems and records. Read the evaluation details for the items that scored low.

    How to confirm. The City's RentSafeTO page has the evaluation results and any open orders for the building. Details

    City of Toronto, RentSafeTO Apartment Building Evaluations

Not in these records

  • Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
  • Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.

History of this lot

17 records on file: more than at 100% of Toronto houses (median 0).

  • By-law investigation26 199957 PRS 00 IRClosed

    Property Standards

    Jul 10, 2026 · 7 HEATH ST E
  • Development application26 185667 STE 12 SAUnder Review

    Mixed use development consisting of three towers organized around a central publicly accessible open space (POPS), along with a new 1,560 m² public park at the northwest corner of the site. The development would include 661 residential units, approximately 15,627 m² of retail, restaurant, wellness and other non-residential uses, and a network of mid-block pedestrian connections, including a direct connection to St. Clair Subway Station. The proposal also incorporates a shared podium for Towers 1 and 2, a standalone Tower 3 connected by an enclosed bridge, and below-grade vehicular, loading and servicing facilities to support a pedestrian-focused public realm.

    Jun 16, 2026 · 25 HEATH ST E · City file
  • By-law investigation26 172585 000 00 IRClosed

    Adequate Heat

    Jun 1, 2026 · 7 HEATH ST E
  • By-law investigation26 172584 000 00 IRClosed

    Property Standards

    Jun 1, 2026 · 7 HEATH ST E
  • By-law investigation25 187755 PRS 00 IVClosed

    Order Issued Property Standards: Exterior steps, not maintained.; Exterior yard surface and/or similar areas not maintained; The exterior walls and their components are not being maintained in good repair.; The guards and/or other appurtenant attachments and/or their supporting structural members are not maintained in good repair.; The retaining wall is not being maintained in good repair.; The roof or one of its components is not weather tight.

    Feb 13, 2025 · 7 HEATH ST E
  • By-law investigation25 187531 PRS 00 IVClosed

    Order Issued Property Standards: Ceiling not maintained free of holes, cracks, damaged and deteriorated materials.; Floor and/or floor covering not kept free from holes, stains, rubbish and debris.; Floor and/or floor covering not kept in a clean and sanitary condition; Floor(s) and/or floor covering(s) not maintained free from trip or other hazardous condition.; Interior door is not a good fit in its frame.; The stair, landing and every appurtenance, surface cover and finish is not maintained.; The stairs and/or other appurtenant attachments and/or their supporting structural members are not maintained in good repair.; Wall(s) not maintained free of holes, cracks, damaged and deteriorated materials.

    Feb 13, 2025 · 7 HEATH ST E
  • By-law investigation25 116706 ZON 00 IRClosed

    Zoning

    Feb 13, 2025 · 7 HEATH ST E
  • By-law investigation25 116705 PRS 00 IRClosed

    Property Standards

    Feb 13, 2025 · 7 HEATH ST E
Show 9 older records
  • By-law investigation25 116704 PRS 00 IRClosed

    Property Standards

    Feb 13, 2025 · 7 HEATH ST E
  • By-law investigation25 116703 PRS 00 IRClosed

    Property Standards

    Feb 13, 2025 · 7 HEATH ST E
  • By-law investigation25 116702 PRS 00 IRClosed

    Property Standards

    Feb 13, 2025 · 7 HEATH ST E
  • By-law investigation25 116701 FEN 00 IRClosed

    Fence

    Feb 13, 2025 · 7 HEATH ST E
  • By-law investigation25 116700 WST 00 IRClosed

    Waste

    Feb 13, 2025 · 7 HEATH ST E
  • Development application21 226522 STE 12 SBUnder Review

    Draft Plan of Subdivision for 4 blocks.

    Oct 15, 2021 · 25 HEATH ST E · City file
  • Development application19 134851 STE 12 OZOMB Appeal

    Application to amend the Official Plan and Zoning By-law to permit a mixed-use development consisting of four residential buildings 44, 39, 27, and 13-storeys, a new park at the northwest corner of the site, a courtyard privately owned publicly-accessible space, and a mid-block connection. The buildings will contain 1,361 dwelling units, of which 38 are replacement for the existing rental units on site. The application proposes 20,524 square metres of non-residential gross floor area.

    Apr 3, 2019 · 25 HEATH ST E · City file
  • Zoning review09 158666 PRZClosed
    Aug 17, 2009 · 7 HEATH ST E
  • Development application09 131301 STE 22 OZClosed

    rezoning application to permit lands to be redeveloped for residential apartment building containing 97 dwelling units , 30 of which are for rental (replacement) purposes complete with 102 parking spaces in four levels below grade - (12 visitors parking spaces included in 102 parking spaces)

    Apr 28, 2009 · 7 HEATH ST E

Check before you build

  • Site-specific exception 900.11.10(695)

    Needs a closer look

    25 site-specific rules and 25 older by-laws that still prevail apply to this lot. They can override the standard rules on this page. 4 parts are limited to an area drawn on a by-law diagram; check whether this lot is in it.

    Zoning By-law 569-2013, Chapter 900
Exception 900.11.10(695)Applies

These parts of the exception apply to this lot's address.

  1. Rule A

    On 1481-1535 Yonge Street, 1-31 Heath Street East and 30-36 Alvin Avenue, and 22 St. Clair Avenue East, if the requirements of By-law 1032-2022 are complied with, a building or structure may be constructed, used or enlarged in compliance with Regulations

  2. Rule B

    to (MM) below; (B) Despite Regulations 40.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum of 147.0 metres and the elevation of the highest point of the building or structure

  3. Rule C

    Despite Regulations 40.10.20.100(45), clause 150.5.20, and 150.5.40.40(1), a home occupation within a dwelling unit may have employees in the dwelling unit who are not the business operator

  4. Rule D

    For the purpose of this exception, the following uses may be provided in combination with a dwelling unit on the lot : (i) office, custom workshop , artist studio , production studio , performing arts studio , private art gallery , software development and processing , personal service shop and retail store

  5. Rule E

    Despite Regulation 40.10.40.1(1), residential use portions of a building may be located on the same storey as non-residential use portions

  6. Rule F

    Despite Regulation 40.10.40.10(2), the permitted maximum height of a building or structure is the number in metres following the letters "HT" as shown on Diagram 7 of By-law 1032-2022

  7. Rule G

    For the purpose of this exception, mezzanines, mechanical penthouses and any portion of a building on the roof top used for washrooms, stairways, access, hallways, vestibules, elevator overruns, residential amenity terraces, does not constitute a storey

  8. Rule H

    Despite Regulations 40.5.40.10(4), (5), (6), (7) and (8) and (F) above, the following equipment and structures may project beyond the permitted maximum height of a building : (i) structures and elements related to outdoor flooring and roofing assembly and drainage, safety railings, guard rails, railings, parapets, terraces, planters, balustrades, eaves, bollards, ancillary structures , retaining walls, and ornamental or architectural features and elements on the roof of the building or structure used for green roof technology and related roofing material, may project above the height limit to a maximum of 2.0 metres; (ii) acoustical barriers, landscape features, lighting fixtures, terrace dividers, stairs and stair enclosures, and fences, may project above the height limits to a maximum of 3.0 metres; (iii) cabanas, awnings, terraces, trellises, ornamental elements, screens, other structures for outside or open air recreation, may project above the height limits to a maximum of 4.0 metres; (iv) equipment and structures used for the functional operation of the building , such as electrical, utility, mechanical penthouse, ventilation, maintenance, safety and green roof purposes, enclosed stairwells, roof access, maintenance equipment storage, elevator shafts, elevator machine rooms, elevator overruns, chimneys, stacks, vents and water supply facilities, and related structural elements that enclose, screen or cover such equipment, as well as areas dedicated for indoor amenity space and associated elevator lobbies/vestibules, may project above the height limits to a maximum of 6.0 metres; (v) architectural crowning elements on Tower 1, as shown on Diagram 7 of By-law 1032-2022, may project above the height limits to a maximum of 11.0 metres; and (vi) window washing equipment, lightning rods, antennae, flagpoles and satellite dishes and wind mitigation features may project up to a maximum height of 5.0 metres above the elements listed in (iv) above

  9. Rule I

    For the purposes of this exception, the total area of all equipment, structures , or parts of any building mentioned in (H)(v) and (iv) above may cover 100 percent of the area of the roof, measured horizontally

  10. Rule J

    Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area of all buildings and structures on the lot is 128,000 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 123,500 square metres; (ii) the required minimum gross floor area for non-residential uses in Area 1, shown in Diagram 7 attached to By-law 1032-2022, is 3,825 square metres; (iii) the required minimum gross floor area for non-residential uses in Area 2, shown in Diagram 7 attached to By-law 1032-2022 is 1,552 square metres; (iv) the required minimum gross floor area for non-residential uses in Area 3, shown in Diagram 7 attached to By-law 1032-2022, is 1,646 square metres; (v) the required minimum gross floor area for non-residential uses in Area 4, shown in Diagram 7 attached to By-law 1032-2022, is 1,163 square metres

  11. Rule K

    Despite Regulations 40.10.20.100(1), (5), (6), (17), (33), a cabaret , club , eating establishment , entertainment place of assembly , place of assembly , recreation use , take-out eating establishment , service shop , retail service , retail store and retail store with beverage manufacturing use for beer, cider and wine may exceed 400 square metres

  12. Rule L

    Section 150.100 does not apply to an eating establishment on the lands

  13. Rule M

    Despite Regulation 40.10.20.100 (20) the outdoor sale or display of goods or commodities: (i) does not need to be combined with another permitted non-residential use; (ii) there is no maximum cumulative area for the outdoor sale or display of goods or commodities; (iii) the area for the outdoor sale or display of goods or commodities may not be located in areas required for parking, loading, driveways or landscaping ; and (iv) storage or warehousing of goods may be permitted in a vehicle

  14. Rule N

    In addition to the uses permitted to be combined with an outdoor patio , as set out in Regulation 40.10.20.100 (21)(A), a retail store with beverage manufacturing use for beer, cider and wine may also have an outdoor patio

  15. Rule O

    Despite Regulations 40.10.20.100 (21)(B) and (C), an outdoor patio : (i) shall have no maximum area; and (ii) may be used to provide entertainment such as performances, music and dancing

  16. Rule P

    Despite Regulation 40.10.40.50(1) and (2), a building with 20 or more dwelling units must provide amenity space on the lot at the following rate: (i) at least 1.7 square metres for each dwelling unit as indoor amenity space ; (ii) at least 1.3 square metres of outdoor amenity space for each dwelling unit ; (iii) no more than 25 percent of the outdoor component may be a green roof ; and (iv) the amenity space required for the lot may be provided within one building

  17. Rule Q

    Despite Regulation 40.10.40.70(2) and (4), the required minimum building setbacks are as shown in metres on Diagram 7 of By-law 1032-2022

  18. Rule R

    Despite Regulation 40.10.40.80(2), the required minimum separation of main walls are as shown in metres on Diagram 7 of By-law 1032-2022

  19. Rule S

    Despite Regulation 40.5.40.60(1), Clause 40.10.40.60, and (Q) and (R) above, the following building elements may encroach into the required minimum building setbacks and main wall separation distances as follows: (i) eaves, cornices, windowsills, light fixtures, to a maximum extent of 1.0 metres; (ii) columns, bollards, wheelchair ramps, stairs and stair enclosures, to a maximum extent of 4.0 metres; (iii) balconies and balcony dividers and ornamental and architectural elements and feature, to a maximum extent of 2.0 metres; (iv) canopies, awnings, trellises, window washing equipment, signage or similar structures , to a maximum extent of 3.0 metres; and (v) guards and guardrails, railings, parapets, terraces, privacy and wind screens, landscape planters and terrace platforms to a maximum extent of the main wall of the storey below

  20. Rule T

    Despite (Q) and (R) above, an interior pedestrian walkway between Tower 1 and Tower 3 may be permitted within the location shown on Diagram 7 of By-law 1032-2022, subject to the following: (i) an interior pedestrian walkway must be located above a height of 6.9 metres and below a height of 18.0 metres, measured between the Canadian Geodetic Datum elevation of 147.0 metres and the highest point of the interior pedestrian walkway

  21. Rule U · diagram area

    For the purposes of this exception, the floor plate of each Tower 1, 2 and 3 on Diagram 7 of By-law 1032-2022 must have a maximum gross floor area of 850 square metres measured from the exterior of the main wall of such floor level, and subject to the floor area reductions of regulation 40.5.40.40(3)

  22. Rule V · diagram area

    For the purposes of this exception, a "Tower" is the portion of the building illustrated on Diagram 7 of By-law 1032-2022 which collectively enclose the entirety of a storey higher than: (i) 28.7 metres for Tower 1; (ii) 20 metres for Tower 2; and (iii) 29 metres for Tower 3

  23. Rule W

    Despite Clause 200.5.10.1, Table 200.5.10.1 and Regulation 200.5.1.10(5), parking spaces must be provided in accordance with the following: (i) a minimum of 0.22 residential occupant parking spaces for each dwelling unit ; (ii) no residential visitor parking spaces are required; (iii) no parking spaces for non-residential uses are required; (iv) Despite Regulation 200.5.10.1(1), "care-share parking spaces" may replace parking spaces otherwise required for residential occupants, subject to the following: (a) a reduction of four (4) parking spaces for residents will be permitted for each "car-share parking space" provided, to a maximum of 10 "car-share parking spaces"; (b) for the purpose of this exception, "car-share" means the practice whereby a number of people share the use of one or more motor vehicles and such "car-share" motor vehicles are made available to at least the occupants of the building for short-term rental, including hourly rental; (c) for the purpose of this exception, "car-share parking spaces" means a parking space exclusively reserved and signed for a vehicle used only for "car-share" purposes; (d) "car-share parking spaces" may be provided in tandem parking spaces

  24. Rule X

    Parking spaces required by (W)(i) above may be provided in a stacked parking space and/or in an automated parking system

  25. Rule Y

    If a parking space is provided in a stacked parking space and/or in an automated parking system, Regulations 200.5.1.10.(2), (3) and (6), do not apply to the parking space

  26. Rule Z

    Parking spaces in public parking may be provided on the lands for the purposes of providing temporary short-term parking for the public and the permitted uses on the lot

  27. Rule AA

    Parking spaces referred to in (Z) above, and drive aisles accessing those parking spaces must be provided in accordance with the following minimum dimensions: (i) for Municipally owned public parking : (a) for parking spaces : 1. a minimum length of 5.2 metres; 2. a minimum width of 2.6 metres; and 3. a minimum vertical clearance of 2.2 metres; (b) for drive aisles : 1. a minimum width of 7.0 metres; (ii) for all other public parking: (a) for parking spaces : 1. a minimum length of 5.6 metres; 2. a minimum width of 2.6 metres; and 3. a minimum vertical clearance of 2.0 metres; (b) for drive aisles : 1. a minimum width of 6.0 metres (BB) Despite Regulation 200.15.1(1), an accessible parking space must have the following dimensions: (i) a minimum length of 5.6 metres; (ii) a minimum width of 3.4 metres; and (iii) a minimum vertical clearance of 2.1 metres; (CC) The entire length of an accessible parking space must be adjacent to a 1.5 metre wide accessible barrier free aisle or path; (DD) Accessible parking spaces must be the parking spaces closest to a barrier free: (i) entrance to a building ; (ii) passenger elevator that provides access to the first storey of the building ; and (iii) and shortest route from the required entrances in (i) and (ii). (EE) Despite Regulation 40.10.100.10(1), a maximum of four vehicle accesses to the lot are permitted and may be provided from Alvin Avenue and/or Heath Street East; (FF) Despite Clause 220.5.10.1, loading spaces must be provided on the lot as follows: (i) for the first building constructed on the lands a minimum of one Type 'G' loading space and one Type 'B' loading space must be provided, plus additional loading spaces as follows: (a) one Type 'B' loading space for non-residential gross floor area on the lot between 2,500 square metres and 4,999 square metres; (b) one Type 'B' loading space for non-residential gross floor area on the lot above 5,000 square metres; and (c) one Type 'C' loading space per each building that contains more than 399 dwelling units ; (ii) for each subsequent building constructed on the lands, loading spaces must be provided as follows: (a) one Type 'B' loading space for non-residential gross floor area on the lot between 2,500 square metres and 4,999 square metres; (b) one Type 'B' loading space for non-residential gross floor area on the lot above 5,000 square metres; and (c) one Type 'C' loading space per each building that contains more than 399 dwelling units ; (GG) For the purpose of this exception, if a mixed use building on the lot has a minimum of 30 dwelling units , the requirement for a Type "A" loading space or a Type "B" loading space is satisfied by the provision of a Type "G" loading space , referred to in Regulation 220.5.1.10(8); (HH) Despite Regulation 40.10.90.40(1), access to the required loading spaces set out in (FF) above may be provided from Alvin Avenue; (II) In addition to the places "long-term" bicycle parking spaces may be located in Regulation 230.5.1.10 (9) and 230.40.1.20(1), "long-term" bicycle parking spaces may be located on any level of a building below ground, or on the first and second storeys above ground or the mezzanine level between the first and second storeys ; (JJ) Despite Regulation 230.5.1.10(7), no change or shower facilities are required; (KK) Despite Regulations 230.5.1.10(6) and (10) and Clause 230.40.1.20, both "long-term" and "short-term" bicycle parking spaces may be located in a secured room, enclosure or bicycle locker may be located in a stacked bicycle parking space ; (LL) Despite Regulations 230.5.1.10(4)(A) and (C), a stacked bicycle parking space must have the following dimensions: (i) a minimum length of 1.8 metres; (ii) a minimum width of 0.45 metres; (iii) despite (ii) above, the width of an upper tier stacked bicycle parking space may be reduced by 0.14 metres per side if the stacked bicycle parking space overlaps with an adjacent stacked bicycle parking space on one or both sides; and (iv) despite (ii) above, the width of a lower tier stacked bicycle parking space may be reduced by 0.32 metres per side if the stacked bicycle parking space overlaps with an adjacent stacked bicycle parking space on one or both sides; (MM) A minimum of 15 percent of the total number of dwelling units on the lands must contain a minimum of two bedrooms and a minimum of 10 percent of the total number of dwelling units on the lands must have three or more bedrooms, provided that: (i) a minimum of 7.5 percent of the dwelling units within each of Areas 1, 2, 3 and 4 shown on Diagram 8 attached to By-law 1032-2022, are required to have a minimum three bedrooms; and (ii) a minimum of 10 percent of all dwelling units on the lands must have a minimum of three bedrooms, once all the buildings are constructed; Prevailing By-laws and Prevailing Sections: (None Apply)

  28. Older by-law A

    On 1481-1535 Yonge Street, 1-31 Heath Street East and 30-36 Alvin Avenue, and 22 St. Clair Avenue East, if the requirements of By-law 1032-2022 are complied with, a building or structure may be constructed, used or enlarged in compliance with Regulations

  29. Older by-law B

    to (MM) below; (B) Despite Regulations 40.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum of 147.0 metres and the elevation of the highest point of the building or structure

  30. Older by-law C

    Despite Regulations 40.10.20.100(45), clause 150.5.20, and 150.5.40.40(1), a home occupation within a dwelling unit may have employees in the dwelling unit who are not the business operator

  31. Older by-law D

    For the purpose of this exception, the following uses may be provided in combination with a dwelling unit on the lot : (i) office, custom workshop , artist studio , production studio , performing arts studio , private art gallery , software development and processing , personal service shop and retail store

  32. Older by-law E

    Despite Regulation 40.10.40.1(1), residential use portions of a building may be located on the same storey as non-residential use portions

  33. Older by-law F

    Despite Regulation 40.10.40.10(2), the permitted maximum height of a building or structure is the number in metres following the letters "HT" as shown on Diagram 7 of By-law 1032-2022

  34. Older by-law G

    For the purpose of this exception, mezzanines, mechanical penthouses and any portion of a building on the roof top used for washrooms, stairways, access, hallways, vestibules, elevator overruns, residential amenity terraces, does not constitute a storey

  35. Older by-law H

    Despite Regulations 40.5.40.10(4), (5), (6), (7) and (8) and (F) above, the following equipment and structures may project beyond the permitted maximum height of a building : (i) structures and elements related to outdoor flooring and roofing assembly and drainage, safety railings, guard rails, railings, parapets, terraces, planters, balustrades, eaves, bollards, ancillary structures , retaining walls, and ornamental or architectural features and elements on the roof of the building or structure used for green roof technology and related roofing material, may project above the height limit to a maximum of 2.0 metres; (ii) acoustical barriers, landscape features, lighting fixtures, terrace dividers, stairs and stair enclosures, and fences, may project above the height limits to a maximum of 3.0 metres; (iii) cabanas, awnings, terraces, trellises, ornamental elements, screens, other structures for outside or open air recreation, may project above the height limits to a maximum of 4.0 metres; (iv) equipment and structures used for the functional operation of the building , such as electrical, utility, mechanical penthouse, ventilation, maintenance, safety and green roof purposes, enclosed stairwells, roof access, maintenance equipment storage, elevator shafts, elevator machine rooms, elevator overruns, chimneys, stacks, vents and water supply facilities, and related structural elements that enclose, screen or cover such equipment, as well as areas dedicated for indoor amenity space and associated elevator lobbies/vestibules, may project above the height limits to a maximum of 6.0 metres; (v) architectural crowning elements on Tower 1, as shown on Diagram 7 of By-law 1032-2022, may project above the height limits to a maximum of 11.0 metres; and (vi) window washing equipment, lightning rods, antennae, flagpoles and satellite dishes and wind mitigation features may project up to a maximum height of 5.0 metres above the elements listed in (iv) above

  36. Older by-law I

    For the purposes of this exception, the total area of all equipment, structures , or parts of any building mentioned in (H)(v) and (iv) above may cover 100 percent of the area of the roof, measured horizontally

  37. Older by-law J

    Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area of all buildings and structures on the lot is 128,000 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 123,500 square metres; (ii) the required minimum gross floor area for non-residential uses in Area 1, shown in Diagram 7 attached to By-law 1032-2022, is 3,825 square metres; (iii) the required minimum gross floor area for non-residential uses in Area 2, shown in Diagram 7 attached to By-law 1032-2022 is 1,552 square metres; (iv) the required minimum gross floor area for non-residential uses in Area 3, shown in Diagram 7 attached to By-law 1032-2022, is 1,646 square metres; (v) the required minimum gross floor area for non-residential uses in Area 4, shown in Diagram 7 attached to By-law 1032-2022, is 1,163 square metres

  38. Older by-law K

    Despite Regulations 40.10.20.100(1), (5), (6), (17), (33), a cabaret , club , eating establishment , entertainment place of assembly , place of assembly , recreation use , take-out eating establishment , service shop , retail service , retail store and retail store with beverage manufacturing use for beer, cider and wine may exceed 400 square metres

  39. Older by-law L

    Section 150.100 does not apply to an eating establishment on the lands

  40. Older by-law M

    Despite Regulation 40.10.20.100 (20) the outdoor sale or display of goods or commodities: (i) does not need to be combined with another permitted non-residential use; (ii) there is no maximum cumulative area for the outdoor sale or display of goods or commodities; (iii) the area for the outdoor sale or display of goods or commodities may not be located in areas required for parking, loading, driveways or landscaping ; and (iv) storage or warehousing of goods may be permitted in a vehicle

  41. Older by-law N

    In addition to the uses permitted to be combined with an outdoor patio , as set out in Regulation 40.10.20.100 (21)(A), a retail store with beverage manufacturing use for beer, cider and wine may also have an outdoor patio

  42. Older by-law O

    Despite Regulations 40.10.20.100 (21)(B) and (C), an outdoor patio : (i) shall have no maximum area; and (ii) may be used to provide entertainment such as performances, music and dancing

  43. Older by-law P

    Despite Regulation 40.10.40.50(1) and (2), a building with 20 or more dwelling units must provide amenity space on the lot at the following rate: (i) at least 1.7 square metres for each dwelling unit as indoor amenity space ; (ii) at least 1.3 square metres of outdoor amenity space for each dwelling unit ; (iii) no more than 25 percent of the outdoor component may be a green roof ; and (iv) the amenity space required for the lot may be provided within one building

  44. Older by-law Q

    Despite Regulation 40.10.40.70(2) and (4), the required minimum building setbacks are as shown in metres on Diagram 7 of By-law 1032-2022

  45. Older by-law R

    Despite Regulation 40.10.40.80(2), the required minimum separation of main walls are as shown in metres on Diagram 7 of By-law 1032-2022

  46. Older by-law S

    Despite Regulation 40.5.40.60(1), Clause 40.10.40.60, and (Q) and (R) above, the following building elements may encroach into the required minimum building setbacks and main wall separation distances as follows: (i) eaves, cornices, windowsills, light fixtures, to a maximum extent of 1.0 metres; (ii) columns, bollards, wheelchair ramps, stairs and stair enclosures, to a maximum extent of 4.0 metres; (iii) balconies and balcony dividers and ornamental and architectural elements and feature, to a maximum extent of 2.0 metres; (iv) canopies, awnings, trellises, window washing equipment, signage or similar structures , to a maximum extent of 3.0 metres; and (v) guards and guardrails, railings, parapets, terraces, privacy and wind screens, landscape planters and terrace platforms to a maximum extent of the main wall of the storey below

  47. Older by-law T

    Despite (Q) and (R) above, an interior pedestrian walkway between Tower 1 and Tower 3 may be permitted within the location shown on Diagram 7 of By-law 1032-2022, subject to the following: (i) an interior pedestrian walkway must be located above a height of 6.9 metres and below a height of 18.0 metres, measured between the Canadian Geodetic Datum elevation of 147.0 metres and the highest point of the interior pedestrian walkway

  48. Older by-law U · diagram area

    For the purposes of this exception, the floor plate of each Tower 1, 2 and 3 on Diagram 7 of By-law 1032-2022 must have a maximum gross floor area of 850 square metres measured from the exterior of the main wall of such floor level, and subject to the floor area reductions of regulation 40.5.40.40(3)

  49. Older by-law V · diagram area

    For the purposes of this exception, a "Tower" is the portion of the building illustrated on Diagram 7 of By-law 1032-2022 which collectively enclose the entirety of a storey higher than: (i) 28.7 metres for Tower 1; (ii) 20 metres for Tower 2; and (iii) 29 metres for Tower 3

  50. Older by-law W

    Despite Clause 200.5.10.1, Table 200.5.10.1 and Regulation 200.5.1.10(5), parking spaces must be provided in accordance with the following: (i) a minimum of 0.22 residential occupant parking spaces for each dwelling unit ; (ii) no residential visitor parking spaces are required; (iii) no parking spaces for non-residential uses are required; (iv) Despite Regulation 200.5.10.1(1), "care-share parking spaces" may replace parking spaces otherwise required for residential occupants, subject to the following: (a) a reduction of four (4) parking spaces for residents will be permitted for each "car-share parking space" provided, to a maximum of 10 "car-share parking spaces"; (b) for the purpose of this exception, "car-share" means the practice whereby a number of people share the use of one or more motor vehicles and such "car-share" motor vehicles are made available to at least the occupants of the building for short-term rental, including hourly rental; (c) for the purpose of this exception, "car-share parking spaces" means a parking space exclusively reserved and signed for a vehicle used only for "car-share" purposes; (d) "car-share parking spaces" may be provided in tandem parking spaces

  51. Older by-law X

    Parking spaces required by (W)(i) above may be provided in a stacked parking space and/or in an automated parking system

  52. Older by-law Y

    If a parking space is provided in a stacked parking space and/or in an automated parking system, Regulations 200.5.1.10.(2), (3) and (6), do not apply to the parking space

  53. Older by-law Z

    Parking spaces in public parking may be provided on the lands for the purposes of providing temporary short-term parking for the public and the permitted uses on the lot

  54. Older by-law AA

    Parking spaces referred to in (Z) above, and drive aisles accessing those parking spaces must be provided in accordance with the following minimum dimensions: (i) for Municipally owned public parking : (a) for parking spaces : 1. a minimum length of 5.2 metres; 2. a minimum width of 2.6 metres; and 3. a minimum vertical clearance of 2.2 metres; (b) for drive aisles : 1. a minimum width of 7.0 metres; (ii) for all other public parking: (a) for parking spaces : 1. a minimum length of 5.6 metres; 2. a minimum width of 2.6 metres; and 3. a minimum vertical clearance of 2.0 metres; (b) for drive aisles : 1. a minimum width of 6.0 metres (BB) Despite Regulation 200.15.1(1), an accessible parking space must have the following dimensions: (i) a minimum length of 5.6 metres; (ii) a minimum width of 3.4 metres; and (iii) a minimum vertical clearance of 2.1 metres; (CC) The entire length of an accessible parking space must be adjacent to a 1.5 metre wide accessible barrier free aisle or path; (DD) Accessible parking spaces must be the parking spaces closest to a barrier free: (i) entrance to a building ; (ii) passenger elevator that provides access to the first storey of the building ; and (iii) and shortest route from the required entrances in (i) and (ii). (EE) Despite Regulation 40.10.100.10(1), a maximum of four vehicle accesses to the lot are permitted and may be provided from Alvin Avenue and/or Heath Street East; (FF) Despite Clause 220.5.10.1, loading spaces must be provided on the lot as follows: (i) for the first building constructed on the lands a minimum of one Type 'G' loading space and one Type 'B' loading space must be provided, plus additional loading spaces as follows: (a) one Type 'B' loading space for non-residential gross floor area on the lot between 2,500 square metres and 4,999 square metres; (b) one Type 'B' loading space for non-residential gross floor area on the lot above 5,000 square metres; and (c) one Type 'C' loading space per each building that contains more than 399 dwelling units ; (ii) for each subsequent building constructed on the lands, loading spaces must be provided as follows: (a) one Type 'B' loading space for non-residential gross floor area on the lot between 2,500 square metres and 4,999 square metres; (b) one Type 'B' loading space for non-residential gross floor area on the lot above 5,000 square metres; and (c) one Type 'C' loading space per each building that contains more than 399 dwelling units ; (GG) For the purpose of this exception, if a mixed use building on the lot has a minimum of 30 dwelling units , the requirement for a Type "A" loading space or a Type "B" loading space is satisfied by the provision of a Type "G" loading space , referred to in Regulation 220.5.1.10(8); (HH) Despite Regulation 40.10.90.40(1), access to the required loading spaces set out in (FF) above may be provided from Alvin Avenue; (II) In addition to the places "long-term" bicycle parking spaces may be located in Regulation 230.5.1.10 (9) and 230.40.1.20(1), "long-term" bicycle parking spaces may be located on any level of a building below ground, or on the first and second storeys above ground or the mezzanine level between the first and second storeys ; (JJ) Despite Regulation 230.5.1.10(7), no change or shower facilities are required; (KK) Despite Regulations 230.5.1.10(6) and (10) and Clause 230.40.1.20, both "long-term" and "short-term" bicycle parking spaces may be located in a secured room, enclosure or bicycle locker may be located in a stacked bicycle parking space ; (LL) Despite Regulations 230.5.1.10(4)(A) and (C), a stacked bicycle parking space must have the following dimensions: (i) a minimum length of 1.8 metres; (ii) a minimum width of 0.45 metres; (iii) despite (ii) above, the width of an upper tier stacked bicycle parking space may be reduced by 0.14 metres per side if the stacked bicycle parking space overlaps with an adjacent stacked bicycle parking space on one or both sides; and (iv) despite (ii) above, the width of a lower tier stacked bicycle parking space may be reduced by 0.32 metres per side if the stacked bicycle parking space overlaps with an adjacent stacked bicycle parking space on one or both sides; (MM) A minimum of 15 percent of the total number of dwelling units on the lands must contain a minimum of two bedrooms and a minimum of 10 percent of the total number of dwelling units on the lands must have three or more bedrooms, provided that: (i) a minimum of 7.5 percent of the dwelling units within each of Areas 1, 2, 3 and 4 shown on Diagram 8 attached to By-law 1032-2022, are required to have a minimum three bedrooms; and (ii) a minimum of 10 percent of all dwelling units on the lands must have a minimum of three bedrooms, once all the buildings are constructed; Prevailing By-laws and Prevailing Sections: (None Apply)

By-law 569-2013, Chapter 900

Lot facts

Area
1,302 m²
Frontage
32.6 m
Depth
40.2 m
Street
Heath St E
Corner lot
No
Public lane
None
House footprint
768 m²roof up to 13.8 m
Back yard
2.6 mhouse to rear lot line
Side yards
0 m and 3.2 mhouse to side lot lines; 0 is a shared wall
Buildings on the lot
1house, garage, sheds
Max height
13 m
Max lot coverage
—

House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.

  • Major Transit Station Area: St Clair. The lot is inside the St Clair Major Transit Station Area approved by the Province (Site and Area Specific Policy 721). Source
  • Yonge-St. Clair Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
  • Zone CR 0.6 (c0.0; r0.6) SS2 (x695) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
  • 4 City trees in front of this lot. The City's street tree inventory lists 4 trees at this address: pine, eastern white (35 cm), cedar, white (25 cm), elm, american (7 cm). Diameter is the trunk at breast height. Source

Around this lot

Minor variances approved
87%34 of 39 decisions
Garden suite permits
2
Laneway suite permits
1
Multiplex permits
6
Development applications
14

Within 300 m, last 10 years. 9 suite and multiplex permits: more than at 72% of Toronto houses (median 3). 39 variance decisions: more than at 74% of Toronto houses (median 19).

Recent variance decisions in the same zone

  • Minor varianceRefused

    To construct a new three-storey non-residential building (including a mezzanine level), with various uses such as: adaptable spaces for community-oriented and commercial uses, a convertible auditorium space, an atrium gathering area, workshops, studios, meeting rooms, café, entertainment places of assembly, eating/take-out establishment(s), and recreation. There will be greenroof areas, an outdoor rooftop terrace, and the rooftop mechanical penthouse will be enclosed (above the second storey).

    1560 YONGE ST · May 27, 2026 · 92 m away
  • Minor varianceApproved

    To permit additional commercial use types on the ground floor of the 44-storey mixed-use building (currently under construction).

    1 DELISLE AVE · Feb 18, 2026 · 127 m away
  • Minor varianceApproved

    To permit a commercial school use (fitness studio occupying Units 106 and 109) on the first storey of the existing 21-storey non-residential building.

    2 ST CLAIR AVE W · Jan 28, 2026 · 196 m away
  • Minor varianceApproved

    To alter the development standards (as approved under Site Specific Zoning By-law 1032-2022) for a mixed-use development comprised of a 13-storey building (Building 1) and three towers (Tower 1 with 44-storeys, Tower 2 with 38-storeys and Tower 3 with 25-storeys) connected by a shared podium on the lot by reallocating a proportion of residential density from Building 1 to Tower 1, increasing the building height of Tower 1 from 44-storeys (144 m) to 46-storeys (161.2 m), decreasing the height of Building 1 from 13-storeys (53.5 m) to four-storeys (25 m), increasing the height and projections of the mechanical penthouse and architectural crowning elements associated with Tower 1, modifying setbacks and separation distance by relocating Tower 2 (north toward Building 1) and by altering the podium element below Tower 3.

    1 HEATH ST E · Dec 10, 2025 · 38 m away
  • Minor varianceApproved

    To redescribe the lands as a result of the conveyance of the rear portion of the lot for parkland dedication.

    30 ST CLAIR AVE W · Oct 29, 2025 · 230 m away

Latest activity nearby

  • Consent (lot split)Pending

    To obtain consent to create new stratified easements/rights-of-way and to maintain existing easements/rights-of-way.File Numbers B0048/26TEY, B0059/26TEY, and B0060/26TEY are associated.

    30 ST CLAIR AVE W · Oct 28, 2027 · 230 m away
  • Consent (lot split)Pending

    To obtain consent to create new stratified easements/rights-of-way and to maintain existing easements/rights-of-way.File Numbers B0048/26TEY, B0059/26TEY, and B0060/26TEY are associated.

    40 ST CLAIR AVE W · Oct 28, 2027 · 244 m away
  • Consent (lot split)Pending

    To obtain consent to create new stratified easements/rights-of-way and to maintain existing easements/rights-of-way.File Numbers B0048/26TEY, B0059/26TEY, and B0060/26TEY are associated.

    1 DELISLE AVE · Aug 10, 2027 · 127 m away
  • Building permit

    Proposed localized concrete repairs for an underground parking garage

    45 ST CLAIR AVE W · Nov 24, 2026 · 299 m away
  • Building permit

    Proposal to install 1 maglocks in existing office space - UNIT 400

    1 ST CLAIR AVE E · Nov 13, 2026 · 230 m away
  • Building permit

    Proposal for maglock installation.

    2 ST CLAIR AVE W · Nov 10, 2026 · 196 m away
  • Building permit

    Proposed interior alterations of existing men and women common floor washrooms

    22 ST CLAIR AVE E · Oct 28, 2026 · 180 m away
  • Building permit

    Proposal for interior alterations for an existing office.

    1 ST CLAIR AVE E · Oct 26, 2026 · 230 m away
  • Building permit

    Proposal for interior alterations of existing suites 201 and 1100.

    21 ST CLAIR AVE E · Oct 21, 2026 · 231 m away
  • Zoning review

    Closed

    1560 YONGE ST · Oct 19, 2026 · 92 m away

Neighbourhood: Rosedale-Moore Park

About the area around the lot, not the lot itself.

Nearest station
St. Clair Station4 min walk
Nearest TTC stop
Yonge St at Heath St East1 min walk
Nearest cycling route
Yonge StCycle Track, 1 min walk
Nearest traffic count
1,599 vehicles in 8 hHeath St E / Alvin Ave (West), 70 m away, Aug 11, 2022
Serious collisions within 500 m
42021–2026, killed or seriously injured: 1 fatal, 1 with pedestrians, 1 with cyclists
Parks
Yorkminster Park Baptist Church Park1 min walk
Lawton Parkette2 min walk
David A. Balfour Park5 min walk

Schools within 1 km

  • DEER PARK JR & SR PUBLIC SCHOOL English Public 3 min walk
  • THE YORK SCHOOL - JR CAMPUS Private 3 min walk
  • THE LINDEN SCHOOL Private 6 min walk
  • THE YORK SCHOOL - MDL AND SR CAMPUS Private 10 min walk
  • UPPER CANADA COLLEGE SCHOOL Private 12 min walk
  • BROWN JR PUBLIC SCHOOL English Public 13 min walk

Being near a school does not mean the lot is in its catchment; check with the board.

2021 Census

FigureRosedale-Moore ParkMedian neighbourhood
Median household income (2020)$122,000$84,500
Households that own their home58%54%
Population (2021)20,08016,813
Homes built in 1960 or before46%29%
Homes needing major repairs6%7%

Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.

Police-reported crime, 2025

Per 100,000 peopleRosedale-Moore ParkCity median
Assault1080.4636.3
Robbery86.869.5
Auto theft199.6192.6
Theft over $5,00065.146.1
Break and enter455.6172.8
Theft from vehicles182.2188.1

Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.

Something here not right?

Sources

  • Building permits on this lot since 2000: Permits issued or applied for since about 2000, with status.
  • Committee of Adjustment files since 2001: Minor variances and consents (lot splits) on this lot and nearby, with decisions.
  • Development applications: Rezoning, site plan, subdivision and condominium applications.
  • Preliminary zoning reviews: Zoning reviews requested before a permit or variance application.
  • Zoning and overlays: Zoning By-law 569-2013 zone, height, coverage, policy area, parking, rooming house, priority retail street and downtown setback overlays.
  • Lot boundary, street and lane: Lot polygon, its addresses, the street it fronts, corner and public lane contact, with frontage and depth measured from the boundary; City of Toronto land in City use, which is not a home.
  • House and yards: Footprint and roof height of the house and other buildings, and the yard behind the house, from the City's 3D Massing (updated yearly, illustrative).
  • City trees in front of the lot: City-owned trees on the street allowance at this address, with species and trunk diameter. Private trees on the lot are not in open data.
  • Heritage: Heritage Register (listed and designated properties), Official Plan Amendment 720 properties and properties removed from the Register under the 2022 two-year limit.
  • TRCA regulated area: Valleys, floodplains, shorelines and wetlands regulated by the Toronto and Region Conservation Authority.
  • Ravines and natural features: Ravine and Natural Feature Protection area (Chapter 658, map last published 2019), Natural Heritage System and Environmentally Significant Areas.
  • Official Plan policies: Site and Area Specific Policies, Secondary Plans and Major Transit Station Areas covering the lot.
  • Rooming houses, short-term rentals and rental buildings: Multi-tenant house licences, short-term rental registrations and RentSafeTO evaluations at this address.
  • Neighbourhood context: Neighbourhood, 2021 Census figures, police-reported crime rates, schools, parks, TTC stops, cycling routes, serious collisions and traffic counts nearby. Area context only, not a finding about the lot.
  • Orders and by-law investigations: Outstanding Toronto Building orders, and by-law investigations open now or closed in the last two years. Fire and Public Health orders and older closed files are not published.
  • Address points: loaded Nov 22, 2026, published Nov 20, 2026
  • Toronto Building orders: loaded Nov 27, 2026, published Nov 26, 2026
  • Neighbourhood Profiles, 2021 Census: loaded Oct 14, 2026, published Oct 6, 2023
  • Street centrelines: loaded Nov 22, 2026, published Nov 20, 2026
  • City-owned land: loaded Nov 22, 2026, published Nov 16, 2026
  • Committee of Adjustment open applications: loaded Nov 27, 2026, published Nov 26, 2026
  • Committee of Adjustment decisions: loaded Nov 27, 2026, published Nov 26, 2026
  • Committee of Adjustment decisions 2001-2016: loaded Oct 14, 2026, published Feb 20, 2026
  • Collisions with people killed or seriously injured (Toronto Police Service): loaded Nov 22, 2026, published Nov 21, 2026
  • Neighbourhood crime rates (Toronto Police Service): loaded Oct 14, 2026, published Feb 20, 2026
  • Cycling network: loaded Nov 22, 2026, published Nov 16, 2026
  • Development applications: loaded Nov 27, 2026, published Nov 27, 2026
  • Environmentally Significant Areas: loaded Oct 14, 2026, published Mar 16, 2026
  • Green spaces: loaded Nov 15, 2026, published Nov 10, 2026
  • Heritage register: loaded Oct 14, 2026, published Sep 1, 2026
  • Former heritage listings: loaded Oct 14, 2026, published Jul 3, 2025
  • Official Plan Amendment 720 heritage list: loaded Oct 14, 2026, published Sep 1, 2026
  • 3D Massing building footprints: loaded Oct 14, 2026, published Dec 2, 2025
  • By-law investigation addresses: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigation deficiencies: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigations: loaded Nov 27, 2026, published Nov 26, 2026
  • Major Transit Station Areas: loaded Oct 14, 2026, published Feb 3, 2026
  • Natural Heritage System: loaded Oct 14, 2026, published Mar 16, 2026
  • Neighbourhoods: loaded Oct 14, 2026, published Feb 20, 2026
  • Property boundaries: loaded Nov 27, 2026, published Nov 27, 2026
  • Active building permits: loaded Nov 27, 2026, published Nov 26, 2026
  • Cleared building permits: loaded Nov 27, 2026, published Nov 26, 2026
  • Cleared building permits 2000-2016: loaded Oct 14, 2026, published Jul 8, 2025
  • Preliminary zoning reviews: loaded Nov 27, 2026, published Nov 26, 2026
  • Ravine and natural feature protection: loaded Oct 14, 2026, published Jul 23, 2019
  • RentSafeTO evaluations: loaded Nov 27, 2026, published Nov 26, 2026
  • Multi-tenant house licences: loaded Nov 27, 2026, published Nov 26, 2026
  • Site and Area Specific Policies: loaded Oct 14, 2026, published Mar 16, 2026
  • School locations: loaded Oct 14, 2026, published May 27, 2026
  • Secondary Plans: loaded Oct 14, 2026, published Mar 16, 2026
  • Street trees: loaded Oct 14, 2026, published Jun 4, 2026
  • Short-term rental registrations: loaded Nov 27, 2026, published Nov 26, 2026
  • Traffic counts at intersections: loaded Nov 22, 2026, published Nov 21, 2026
  • TRCA regulation limit: loaded Oct 14, 2026, published Apr 29, 2026
  • TTC stops (GTFS): loaded Nov 8, 2026, published Nov 5, 2026
  • Zoning by-law: loaded Oct 14, 2026, published Feb 20, 2026
  • Lot coverage overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Height overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Parking zone overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Policy area overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Priority retail streets: loaded Oct 14, 2026, published Feb 20, 2026
  • Rooming house overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Zoning setbacks: loaded Oct 14, 2026, published Feb 20, 2026

Contains information licensed under the Open Government Licence – Toronto. TRCA regulation limit © TRCA.

Screening tool based on City of Toronto and TRCA open data. Not a zoning review or legal opinion. Site-specific exceptions, amendments not yet in the open data, minor variances and other by-laws can change the answer. Confirm with a Preliminary Project Review or Zoning Certificate from Toronto Building before buying or designing.