Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
2 development applications open within 300 m
Good to know2 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 8 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
2 records on file: more than at 72% of Toronto houses (median 0).
- Development application14 200121 STE 32 SAClosed
Proposed 6 storey residential apartment building with grade related retail. Total 56 units with 44 parking spaces below grade.
Jul 31, 2014 · 691 KINGSTON RD - Development application14 200116 STE 32 OZClosed
Proposed 7 storey residential apartment building with grade related retail. Total 49 units with 62 parking spaces below grade.Applicant to register one condominium for subject development and 622 & 646 Kingston Road being processed under 14 200168 STE 32 OZApplicant has purchased lot to the east. To be used to expand underground parking and two semi detached dwellings at grade. OPA is required.
Jul 31, 2014 · 691 KINGSTON RD
Check before you build
Site-specific exception 900.11.10(25)
Needs a closer look14 site-specific rules and 14 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule B
to (O) below. (B) Within the hatched area shown on Diagram 3 of By-law No. 785-2015, the only uses permitted are two dwellings units in a mixed use building , a below grade parking garage , and the vehicular access.
- Rule C
The total gross floor area of the building must not exceed a maximum of 5,500 square metres and must not exceed: (i) 4,875 square metres for the residential uses (dwelling units) in the building ; and (ii) 620 square metres for the non-residential use.
- Rule D
The maximum permitted number of dwelling units is forty-nine (49).
- Rule E
The height of any building or structure on the lot must not exceed the maximum height permitted as indicated by the letter "H" as shown on Diagram 5 of By-law No. 785-2015, measured from the Canadian Geodetic Datum elevation of 125.5 metres.
- Rule F
Despite (E) above, parapets, lighting fixtures, fences, safety railings, stairs, stair enclosures, terraces, landscape planters, trellises or privacy screens shall be permitted to project beyond the height permitted provided the height of the fence, safety railing or privacy fence does not exceed 2.0 metres beyond the height indicated on Diagram 5 of By-law No. 785-2015.
- Rule G
No portion of any building or structure to be erected or used on the lot can extend beyond the lines delineated by the heavy lines on Diagram 4 and Diagram 5 of the By-law No. 785-2015.
- Rule H
Despite (G) above, eaves, cornices, lighting fixtures, window sills, landscape planters, trellises, stairs, stair enclosures, railings, awnings, canopies and other minor architectural projections are permitted to project no more than 0.45 metres, beyond the heavy lines on Diagram 4 and Diagram 5 of By-law No. 785-2015.
- Rule I
Despite (G) above, balconies are permitted to project not more than 1.8 metres beyond the heavy lines on Diagram 5 on the north and west elevations of the building .
- Rule J
Despite (G) and (I) above, balconies are permitted to project not more than 2.25 metres beyond the heavy lines as shown on the south elevation of Diagram 5 for portions of the building beginning 4.0 metres and higher measured from the Canadian Geodetic Datum elevation of 125.5 metres.
- Rule K
No windows or doors are permitted on the south elevation of the building unless a minimum setback of 3.5 metres is provided between the main wall of the building and the south lot line .
- Rule L
Despite (K) above, doors are permitted on the south elevation of the building shown on Diagram 4.
- Rule M
Parking spaces must be provided in accordance with the following: (i) A minimum of 0.5 parking spaces for each bachelor or one-bedroom unit dwelling unit , a minimum of 0.7 parking spaces for each dwelling unit containing two-bedrooms, and a minimum of 1.1 parking spaces for each dwelling unit containing three-bedrooms must be provided on the lot in a parking garage ; and (ii) A minimum of 15 visitor parking spaces must be provided on the lot and be available for mutual use with the apartment building known municipally in the year 2014 as 622 and 646 Kingston Road.
- Rule N
One loading space must be provided on the lot in accordance with the following: (i) A minimum length of 13.0 metres; (ii) A minimum width of 4.0 metres; and (iii) A minimum vertical clearance of 6.1 metres over at least the first 8.0 metres of the loading space measured from the end of the loading space opposite the entrance to it, and a vertical clearance of at least 4.3 metres over the balance of the loading space . [amended by by-lw 580-2017]
- Rule O
A minimum of 120 square metres of indoor residential amenity space must be provided on the lot and be available for mutual use with the apartment building known municipally in the year 2014 as 622 and 646 Kingston Road. Prevailing By-laws and Prevailing Sections: (None Apply)
- Older by-law B
to (O) below. (B) Within the hatched area shown on Diagram 3 of By-law No. 785-2015, the only uses permitted are two dwellings units in a mixed use building , a below grade parking garage , and the vehicular access.
- Older by-law C
The total gross floor area of the building must not exceed a maximum of 5,500 square metres and must not exceed: (i) 4,875 square metres for the residential uses (dwelling units) in the building ; and (ii) 620 square metres for the non-residential use.
- Older by-law D
The maximum permitted number of dwelling units is forty-nine (49).
- Older by-law E
The height of any building or structure on the lot must not exceed the maximum height permitted as indicated by the letter "H" as shown on Diagram 5 of By-law No. 785-2015, measured from the Canadian Geodetic Datum elevation of 125.5 metres.
- Older by-law F
Despite (E) above, parapets, lighting fixtures, fences, safety railings, stairs, stair enclosures, terraces, landscape planters, trellises or privacy screens shall be permitted to project beyond the height permitted provided the height of the fence, safety railing or privacy fence does not exceed 2.0 metres beyond the height indicated on Diagram 5 of By-law No. 785-2015.
- Older by-law G
No portion of any building or structure to be erected or used on the lot can extend beyond the lines delineated by the heavy lines on Diagram 4 and Diagram 5 of the By-law No. 785-2015.
- Older by-law H
Despite (G) above, eaves, cornices, lighting fixtures, window sills, landscape planters, trellises, stairs, stair enclosures, railings, awnings, canopies and other minor architectural projections are permitted to project no more than 0.45 metres, beyond the heavy lines on Diagram 4 and Diagram 5 of By-law No. 785-2015.
- Older by-law I
Despite (G) above, balconies are permitted to project not more than 1.8 metres beyond the heavy lines on Diagram 5 on the north and west elevations of the building .
- Older by-law J
Despite (G) and (I) above, balconies are permitted to project not more than 2.25 metres beyond the heavy lines as shown on the south elevation of Diagram 5 for portions of the building beginning 4.0 metres and higher measured from the Canadian Geodetic Datum elevation of 125.5 metres.
- Older by-law K
No windows or doors are permitted on the south elevation of the building unless a minimum setback of 3.5 metres is provided between the main wall of the building and the south lot line .
- Older by-law L
Despite (K) above, doors are permitted on the south elevation of the building shown on Diagram 4.
- Older by-law M
Parking spaces must be provided in accordance with the following: (i) A minimum of 0.5 parking spaces for each bachelor or one-bedroom unit dwelling unit , a minimum of 0.7 parking spaces for each dwelling unit containing two-bedrooms, and a minimum of 1.1 parking spaces for each dwelling unit containing three-bedrooms must be provided on the lot in a parking garage ; and (ii) A minimum of 15 visitor parking spaces must be provided on the lot and be available for mutual use with the apartment building known municipally in the year 2014 as 622 and 646 Kingston Road.
- Older by-law N
One loading space must be provided on the lot in accordance with the following: (i) A minimum length of 13.0 metres; (ii) A minimum width of 4.0 metres; and (iii) A minimum vertical clearance of 6.1 metres over at least the first 8.0 metres of the loading space measured from the end of the loading space opposite the entrance to it, and a vertical clearance of at least 4.3 metres over the balance of the loading space . [amended by by-lw 580-2017]
- Older by-law O
A minimum of 120 square metres of indoor residential amenity space must be provided on the lot and be available for mutual use with the apartment building known municipally in the year 2014 as 622 and 646 Kingston Road. Prevailing By-laws and Prevailing Sections: (None Apply)
2 parts for other addresses
- A On 663 and 691 Kingston Road, if the requirements of this By-law No. 785-2015 are complied with, none of the provisions of 10.10.40.80(1)(C), …
- A On 663 and 691 Kingston Road, if the requirements of this By-law No. 785-2015 are complied with, none of the provisions of 10.10.40.80(1)(C), …
Lot facts
- Area
- 685 m²
- Frontage
- 33.8 mestimated, irregular lot
- Depth
- 31.5 mestimated, irregular lot
- Street
- Kingston Rd
- Corner lot
- No
- Public lane
- Dr. Alan Hutchison Lane, 17.4 m along it
- Max height
- 14 m
- Max lot coverage
- —
Around this lot
- Minor variances approved
- 90%28 of 31 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 1
- Multiplex permits
- 4
- Development applications
- 4
Within 300 m, last 10 years. 5 suite and multiplex permits: more than at 59% of Toronto houses (median 3). 31 variance decisions: more than at 64% of Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To alter the existing four-storey commercial building by constructing a rear second and third storey addition over the existing parking area and a rear fourth storey addition.
577 KINGSTON RD · Oct 11, 2017 · 172 m away
Latest activity nearby
- Building permit
Proposal to legalize roof top terrace and guards in existing mixed use building.
577 KINGSTON RD · Nov 10, 2026 · 172 m away - Zoning review
Closed
9 BENLAMOND AVE · Nov 9, 2026 · 259 m away - Building permit
PROPOSAL TO DEMOLISH THE EXISTING DWELLING AND CONSTRUCT A NEW CUSTOM 3 STOREY SINGLE FAMILY DWELLING WITH FINISHED BASEMENT
20 LONG CRES · Nov 6, 2026 · 265 m away - Building permit
PROPOSAL FOR A NEW CUSTOM 3 STOREY SINGLE FAMILY DWELLING WITH FINISHED BASEMENT
20 LONG CRES · Nov 6, 2026 · 265 m away - Building permit
Proposed installation of new fire alarm devices, connected to the existing fire alarm system, for the modernization of existing elevator
700 KINGSTON RD · Nov 6, 2026 · 86 m away - Building permit
Solar collector panel installation to roof of existing 4 storey Group D office building
577 KINGSTON RD · Oct 16, 2026 · 172 m away - Building permit
Proposal to demolish existing dwelling and construct a new 4-unit detached dwelling and a detached garage.
2 KIMBERLEY AVE · Oct 15, 2026 · 251 m away - Building permit
Proposal to demolish existing dwelling and construct a new 4-unit detached dwelling and a detached garage.
2 KIMBERLEY AVE · Oct 15, 2026 · 251 m away - Building permit
Proposal of new roof on existing deck in rear yard.
51 WINTHORPE RD · Oct 15, 2026 · 172 m away - Development application
The proposed development is for a 4-storey (14.31 metre) apartment building with 16 residential units, a total Gross Floor Area of 1,627.50 square metres, and a proposed density of 1.26. A total of 7 vehicular parking spaces are provided in the underground parking level and 17 bicycle parking spaces are proposed.
9 BENLAMOND AVE · Oct 7, 2026 · 268 m away · City file
Neighbourhood: The Beaches
About the area around the lot, not the lot itself.
- Nearest station
- Danforth GO Station17 min walk
- Nearest TTC stop
- Southwood Dr at Kingston Rd1 min walk
- Nearest cycling route
- Southwood DrSigned Route (No Pavement Markings), 1 min walk
- Nearest traffic count
- 18,930 vehicles in 14 hKingston Rd / Southwood Dr / Main St, 50 m away, Oct 20, 2024
- Serious collisions within 500 m
- 02021–2026, killed or seriously injured
- Parks
- Glen Stewart Park4 min walk
- Love Crescent Parkette7 min walk
- Norwood Park9 min walk
Schools within 1 km
- ST JOHN CATHOLIC ELEMENTARY SCHOOL English Separate 4 min walk
- NOTRE DAME CATHOLIC HIGH SCHOOL English Separate 6 min walk
- BEACHES ALTERNATIVE JR & KIMBERLEY JR English Public 7 min walk
- WILLIAMSON ROAD JR PUBLIC SCHOOL English Public 8 min walk
- GLEN AMES SR PUBLIC SCHOOL English Public 9 min walk
- MALVERN COLLEGIATE INSTITUTE English Public 9 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | The Beaches | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $116,000 | $84,500 |
| Households that own their home | 63% | 54% |
| Population (2021) | 21,510 | 16,813 |
| Homes built in 1960 or before | 65% | 29% |
| Homes needing major repairs | 7% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | The Beaches | City median |
|---|---|---|
| Assault | 525.6 | 636.3 |
| Robbery | 25.2 | 69.5 |
| Auto theft | 164 | 192.6 |
| Theft over $5,000 | 50.5 | 46.1 |
| Break and enter | 151.4 | 172.8 |
| Theft from vehicles | 243.9 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.