Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
Heritage property: designated (Part IV)
Needs a closer lookOn the City's Heritage Register. Demolition and exterior changes need heritage review.
What it means. Renovations, additions and demolition can take longer, cost more or be refused.
How to confirm. Heritage Planning at the City confirms the status and what it covers. Details
City of Toronto Heritage RegisterWork or applications in progress
Good to knowRecent records on this lot: 18 149815 STE 28 SA (Site Plan Control application for a 51-storey mixed use building with a GFA of 35,000 s..., 2018).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications1 Committee of Adjustment file on this lot
Good to know1 approved. A0282/25TEY (To facilitate the redevelopment of this site for a 51-storey mixed-use building, includ..., 2025).
What it means. Approved variances and consents stay with the property, including any conditions in the decision. They allow what was approved, not more.
How to confirm. Decisions are in the Application Information Centre; older files are available from the Committee of Adjustment office. Details
City of Toronto, Committee of Adjustment applications (2001 onwards)9 development applications open within 300 m
Good to know9 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 69 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
13 records on file: more than at 100% of Toronto houses (median 0).
- By-law investigation26 158054 GRA 00 IRNotice Issued
Graffiti
May 10, 2026 · 601 SHERBOURNE ST - By-law investigation25 230167 GRA 00 IVClosed
Notice Issued Graffiti
Aug 30, 2025 · 601 SHERBOURNE ST - By-law investigation25 218184 GRA 00 IRClosed
Graffiti
Aug 30, 2025 · 601 SHERBOURNE ST - Minor varianceA0282/25TEYApproved
To facilitate the redevelopment of this site for a 51-storey mixed-use building, including the Parkland dedication requirement. This application is necessitated to modify Sections 4, 7, 16, and 24 under Appendix 1, Site Specific Zoning By-law 1528-2019, and Sections 4, 7, 15, and 23 under Schedule A, Site Specific Zoning By-law 1529-2019, which relates to the timing of conveyance and lease of the parklands and the construction for park improvements.
Jun 11, 2025 · 601 SHERBOURNE ST - Development application18 149815 STE 28 SANOAC Issued
Site Plan Control application for a 51-storey mixed use building with a GFA of 35,000 sq. m with 499 sq. m of retail space and 511 residential units, and the total number of rental units on the Block is 2057 units, of which 24 are rental replacement units (and therefore not market). The overall FSI is 7.38.
Apr 27, 2018 · 601 SHERBOURNE ST · City file - Development application15 206976 STE 28 OZClosed
Redevelopment of the subject properties for a 51-storey rental building, with retail uses at grade. As part of these applications they are also proposing to reconfigure St. James Town West Park, and make significant improvements to it. The existing heritage designated building at 601 Sherbourne Street (known as the Thomas Cruttenden Building) will be retained and no changes will be made to the existing rental units within the building. The existing underground parking garage on the Block will be modified to connect below grade to the new building. The new building will have a total Gross Floor Area (GFA) of approximately 34600 square metres, of which approximately 400 square metres will be atgrade retail space. A total of 532 new rental residential units are proposed. The new development will result in a total of 2057 units of market rental units (in bachelor, one-bedroom, two-bedroom and three-bedroom configurations) on the Block and an overall Floor Space Index (FSI) of 7.38
Aug 14, 2015 · 601 SHERBOURNE ST · City file - Zoning review11 147295 LTOClosedMar 17, 2011 · 5 HOWARD ST
- Zoning review10 264974 LPRClosedSep 24, 2010 · 601 SHERBOURNE ST
Show 5 older records
- Building permit10 213177Closed
Proposal to erect 3 first party illuminated fascia signs. Tenant - "EggSmart".
Aug 9, 2010 · 601 SHERBOURNE ST - Building permit10 187314Closed
Proposal to install a new kitchen exhaust hood. Tenant - "EggSmart".
Jun 7, 2010 · 601 SHERBOURNE ST - Zoning review03 179464 LTOClosedSep 29, 2003 · 601 SHERBOURNE ST
- Zoning review02 162262 LTOClosedAug 12, 2002 · 601 SHERBOURNE ST
- Zoning review01 012552 LTOClosedApr 17, 2001 · 601 SHERBOURNE ST
Check before you build
Site-specific exception 900.11.10(184)
Needs a closer look17 site-specific rules apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
On 545, 555, 561, 565, 583, 589, 591, 595, 599 and 601 Sherbourne Street, 306-334 Bleecker Street, 346-350 Bleecker Street, 354-368 Bleecker Street, 60-68 Earl Street, 280-294 Bleecker Street, 61 Earl Street and 3-7 Howard Street, if the requirements of Section 8 and Schedule A of By-law 1529-2019 are complied with, Regulations 40.10.40.10(2) and 40.10.40.40(1) do not apply to prevent the erection of mixed-use buildings and apartment buildings that comply with
- Rule B
to (P) below; (B) Despite Regulation 40.10.40.40(1), the maximum gross floor area of Buildings E and F as shown on Diagram 6 of By-law 1529-2019, must not exceed 36,000 square metres, of which a maximum of 35,200 square metres may be used for residential uses, and a maximum of 800 square metres may be used for non-residential uses
- Rule C
Despite Regulation 800.50(300), in Area B as shown on Diagram 1 of By-law 1529-2019, excluding Building E as shown on Diagram 6 of By-law 1529-2019, gross floor area is defined by zoning by-law 438-86 and the maximum gross floor area is 114,950 square metres, of which a maximum of 109,720 square metres may be used for residential uses and a maximum of 5,250 square metres may be used for non-residential uses
- Rule D
In Buildings E and F as shown on Diagram 6 of By-law 1529-2019, the number of dwelling units and types of dwelling units must comply with the following: (i) The maximum total number of dwelling units is 545; (ii) The minimum number of three-bedroom dwelling units is 43; and (iii) The minimum number of two-bedroom dwelling units is 137
- Rule E
Despite Regulations 5.10.40.70(1) and 40.10.40.70(2), the required minimum building setbacks are identified on Diagrams 6 and 7 of By-law 1529-2019
- Rule F
Despite Clause 40.10.40.60 and (E) above, the following are permitted to encroach into the required building setbacks shown on Diagram 6 of By-law 1529-2019: (i) cornices, lighting fixtures, , ornamental elements, eaves, window sills, guardrails, balustrades, railings, wheel chair ramps, thermal insulation and roof ballast, and pipes , to a maximum of 0.3 metres; (ii) window washing equipment and vents to a maximum of 3.0 metres; (iii) canopies and awnings to a maximum of 3.5 metres; and (iv) balconies to a maximum of 2.0 metres, provided they do not project beyond the lot line
- Rule G
Despite Clause 40.10.40.60 and (E) above, the following are permitted to encroach into the required building setbacks shown on Diagram 7 of By-law 1529-2019; (i) awnings, lighting fixtures, ornamental elements, trellises, window sills, balustrades, stairs, stair enclosures, wheelchair ramps, underground garage ramps, landscape and public art features may extend to a maximum of 1.0 metres; and (ii) balconies to a maximum of 1.5 metres
- Rule H
Despite Regulations 40.5.40.10(1), the height of a building or structure is measured as follows: (i) For Buildings E and F as shown on Diagram 6 of By-law 1529-2019, as the distance between the Canadian Geodetic Datum elevation of 115.30 metres to the highest point of the building or structure ; (ii) in Area B as shown on Diagram 1 of By-law 1529-2019, excluding Building E as shown on Diagram 6 of By-law 1529-2019, as the distance between the Canadian Geodetic Datum elevation of 114.79 metres to the highest point of the building or structure
- Rule I
Despite Regulation 40.10.40.10(2), the permitted maximum height of any building must not exceed the height in metres specified by the numbers following the symbol "HT" on Diagrams 6 and 7 of By-law 1529-2019
- Rule J
Despite Clause 40.5.40.10 and (I) above, the following building elements and structures on Buildings E and F as shown on Diagram 6 of By-law 1529-2019 may project above the permitted maximum height shown on Diagram 6 of By-law 1529-2019: (i) stairs and stair enclosures, elevator, heating, cooling or ventilating equipment, mechanical penthouse, wall or structure enclosing such elements to a maximum of 7.5 metres; (ii) decks, planters, parapets, railings retaining walls, and roof access hatches to a maximum of 1.5 metres; (iii) chimneys, fencing, landscape and public art features, lighting fixtures, ornamental elements, trellises, flues, pipes, stacks, structures located on the roof used for outside or open air recreation, terrace or balcony guard dividers, vents, wind protection and safety features to a maximum of 3.0 metres; and (iv) waterproofing materials, pavers and green roof elements to a maximum of 0.4 metres
- Rule K
Despite Regulations 40.10.40.10(2),40.5.40.10, and (I) above, the following building elements and structures within Area B, as shown on Diagram 1 of By-law 1529-2019, excluding Building E as shown on Diagram 6 of By-law 1529-2019, may project above the permitted maximum height shown on Diagram 7 of By-law 1529-2019: (i) the parapets, terrace guards and dividers, planters, railings, decorative screens, and window washing equipment to a maximum of 1.0 metres
- Rule L
A minimum of 3,440 square metres of landscaped open space must be provided on the lands, which may include structures that provide access to an underground parking garage that are both below ground level and above ground level with a maximum height of 3.0 metres and may include structures for venting that are at and/or below ground level provided that the total area of all access structure and venting structures does not exceed 90 square metres.
- Rule M
Despite Regulation 40.10.40.50(1), amenity space must be provided for each building identified on Diagrams 6 and 7 of By-law 1529-2019, or on the lands, as follows: (i) Building A – a minimum of 200 square metres of indoor amenity space for the dwelling units; (ii) Building B – a minimum of 250 square metres of indoor amenity space for the dwelling units; (iii) Building C – a minimum of 223 square metres of indoor amenity space for the dwelling units; (iv) Building D – a minimum of 2.0 square metres of indoor amenity space per residential unit within Building D for the dwelling units ; (v) Building E – a minimum of 1,060 square metres of indoor amenity space for the dwelling units ; (vi) Building E – a minimum of 630 square metres of outdoor amenity space for the dwelling units ; and (vii) A minimum of 3,280 square metres of outdoor amenity space must be provided on the lands , excluding the outdoor amenity space required for Building E as specified in (M)(vi) above.
- Rule N
Despite Regulations 200.5.1.10(2) and 200.5.10.1(1) and Articles 200.15.1 and 200.15.10, parking spaces must be provided and maintained on the lands as follows: (i) a minimum of 597 parking spaces must be provided for the residents of the dwelling units ; (ii) a minimum of 206 parking spaces must be provided on Level P1 for visitors to residents of the dwelling units and non-residential uses; (iii) a maximum of 93 parking spaces may be used as public parking ; (iv) of the total number of parking spaces on the lands, a maximum of 243 parking spaces may be obstructed on one side; and (v) a minimum of 7 accessible parking spaces , which must have a minimum width of 3.65 metres and do not require an adjacent barrier-free aisle or path
- Rule O
Despite Clause 230.5.10, bicycle parking spaces must be provided and maintained for each building identified on Diagrams 6 and 7 of By-law 1529-2019, or on the lands follows: (i) Buildings A, B and C – a minimum of 194 long-term bicycle parking spaces for the residents of the dwelling units ; (ii) Building D – a minimum of 246 long-term bicycle parking spaces for the residents of the dwelling units ; (iii) Building E – a minimum of 475 long-term bicycle parking spaces for the residents of the dwelling units ; (iv) a minimum of 150 short-term bicycle parking spaces for visitors of the dwelling units and non-residential uses for all buildings on the lands, of which a minimum of 40 short-term bicycle parking spaces must be provided above ground and the remaining must be located below ground in a secured room on Level P1; (v) bicycle parking spaces may be stacked bicycle parking spaces ; and (vi) a stacked bicycle parking space may overlap an adjacent stacked bicycle parking space on one or both sides on the same tier to a maximum of 0.2 metres per side
- Rule P
Despite Clause 220.5.10.1(3), loading spaces must be provided on the lands in accordance with the following: (i) a minimum of one loading space – type "A" ; (ii) a minimum of four loading spaces – type "B" ; (iii) a minimum of one loading space – type "C" that must be located in Building E as shown on Diagram 6 of By-law 1529-2019; and (iv) a minimum of two loading space – type "G" , one of which will have a minimum vertical clearance of 6.1 metres for 9.5 metres of its length
- Rule Q
Despite Regulation 40.10.100.10(1), two vehicle accesses are permitted.
Lot facts
- Area
- 210 m²
- Frontage
- 6.8 m
- Depth
- 35.7 m
- Street
- Sherbourne St
- Corner lot
- Yes, also on Howard St35.7 m along it
- Public lane
- None
- House footprint
- 196 m²roof up to 17 m
- Back yard
- 1.8 mhouse to rear lot line
- Side yards
- 0 m and 0 mhouse to side lot lines; 0 is a shared wall
- Buildings on the lot
- 1house, garage, sheds
- Max height
- 12 m
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
- Major Transit Station Area: Sherbourne. The lot is inside the Sherbourne Major Transit Station Area approved by the Province (Site and Area Specific Policy 601). Source
- Downtown Plan Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
- Zone CR 1.5 (c1.0; r1.0) SS2 (x184) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
Around this lot
- Minor variances approved
- 100%15 of 15 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 2
- Development applications
- 24
Within 300 m, last 10 years. 2 suite and multiplex permits: no more than at most Toronto houses (median 3). 15 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceRefused
To alter the development standards, as approved under Site Specific Zoning By-laws 22769 and 325-82, for the existing 27-storey mixed-use building by reducing the building setbacks, increasing the residential dwelling units from 479 to 495 units, increasing the total gross floor area, and reducing the total amenity space. This application is subject to a Site Plan Control application, which has not yet been submitted by the applicant.
235 BLOOR ST E · Nov 4, 2026 · 393 m away - Minor varianceApproved
To permit 30 undersized/partially obstructed vehicular parking spaces within the existing underground parking garage (Parking Levels 1 to 5) of the 53-storey mixed-use building, which is currently under construction.
603 SHERBOURNE ST · Nov 26, 2025 · 29 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 1529-2019), for a new 56-storey mixed-use building (which is currently under construction), by increasing the gross floor area, the total number of dwelling units, and the building height(s) for Building E (145.5 m to 159 m). There will be a total of 600 residential dwelling units on this lot.
591 SHERBOURNE ST · Sep 3, 2025 · 29 m away - Minor varianceApproved
To facilitate the redevelopment of this site for a 51-storey mixed-use building, including the Parkland dedication requirement. This application is necessitated to modify Sections 4, 7, 16, and 24 under Appendix 1, Site Specific Zoning By-law 1528-2019, and Sections 4, 7, 15, and 23 under Schedule A, Site Specific Zoning By-law 1529-2019, which relates to the timing of conveyance and lease of the parklands and the construction for park improvements.
601 SHERBOURNE ST · Jun 11, 2025 · 7 m away - Minor varianceApproved
To permit the replacement of 4 new mechanical units.
1 MOUNT PLEASANT RD · Apr 9, 2025 · 289 m away
Latest activity nearby
- Zoning review
Not Started
421 BLOOR ST E · Nov 23, 2026 · 128 m away - Building permit
Proposal for interior alterations to replace existing indoor diesel life-safety generator with new rooftop natural gas life safety generator.
77 HUNTLEY ST · Nov 18, 2026 · 223 m away - Building permit
Revision 01 - fire alarm upgrade to P1, P2, P3, P4, P5 and first and second floorFire Alarm Upgrade: to add strobes in the required area to address accessibility requirement, the rest existing fire alarm to remain.
1 MOUNT PLEASANT RD · Nov 18, 2026 · 289 m away - Building permit
Three wall sign.***NO FRILLS***
345 BLOOR ST E · Nov 10, 2026 · 162 m away - Building permit
Proposal for interior alteration to fit the nails salon
4 HOWARD ST · Oct 30, 2026 · 42 m away - Building permit
Replacement of existing fire damaged balcony railings and repair of existing balconies for unit 2307 & 2407.
375 BLEECKER ST · Oct 30, 2026 · 115 m away - Building permit
Interior alterations for a new nail salon in unit 4
6 HOWARD ST · Oct 27, 2026 · 53 m away - Building permit
Fire Damage in a High-rise Residential Building: Removing and replacing all damaged interior finishes and partition walls, balcony windows and doors, and balcony railings in the affected unit. If further investigation confirms damage to the concrete balcony slab, it will be repaired or replaced.
666 ONTARIO ST · Oct 16, 2026 · 289 m away - Building permit
Scope: to alter Designated Heritage houses in accordance with building design and Heritage Conservation Plan for integration with main tower.Construct a 61 storey market rental tower, with 4 levels of below grade parking. Proposed rental unit count is 716 units.
37 LINDEN ST · Oct 9, 2026 · 66 m away - Building permit
Scope: to alter Designated Heritage houses in accordance with building design and Heritage Conservation Plan for integration with main tower.Construct a 61 storey market rental tower, with 4 levels of below grade parking. Proposed rental unit count is 716 units
29 LINDEN ST · Oct 9, 2026 · 95 m away
Neighbourhood: North St.James Town
About the area around the lot, not the lot itself.
- Nearest station
- Sherbourne Station2 min walk
- Nearest TTC stop
- Sherbourne Station - Eastbound Platform2 min walk
- Nearest cycling route
- Sherbourne StCycle Track, 1 min walk
- Nearest traffic count
- 9,684 vehicles in 14 hHoward St / Sherbourne St, 30 m away, Sep 11, 2025
- Serious collisions within 500 m
- 52021–2026, killed or seriously injured: 1 fatal, 2 with pedestrians, 2 with cyclists
- Parks
- St. James Town West Park1 min walk
- Rosedale Ravine Lands3 min walk
- Dr. Gordon Chong Park4 min walk
Schools within 1 km
- MONSIGNOR FRASER COLLEGE - ISABELLA NORTH English Separate 2 min walk
- MONSIGNOR FRASER COLLEGE - ISABELLA CAMPUS English Separate 3 min walk
- ROSE AVENUE JR PUBLIC SCHOOL English Public 5 min walk
- BRANKSOME HALL GIRLS SCHOOL Private 9 min walk
- OUR LADY OF LOURDES CATHOLIC ELEMENTARY SCHOOL English Separate 9 min walk
- JARVIS COLLEGIATE INSTITUTE English Public 9 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | North St.James Town | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $59,200 | $84,500 |
| Households that own their home | 11% | 54% |
| Population (2021) | 18,535 | 16,813 |
| Homes built in 1960 or before | 19% | 29% |
| Homes needing major repairs | 10% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | North St.James Town | City median |
|---|---|---|
| Assault | 1281.6 | 636.3 |
| Robbery | 76.9 | 69.5 |
| Shootings | 4.3 | 10.5 |
| Auto theft | 85.4 | 192.6 |
| Theft over $5,000 | 38.4 | 46.1 |
| Break and enter | 153.8 | 172.8 |
| Theft from vehicles | 136.7 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.