Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
TRCA regulated area (20% of lot)
Needs a closer lookPart of the lot is near a valley, floodplain, shoreline or wetland. Work there needs a TRCA permit and may be restricted.
What it means. Additions, pools and new buildings in the regulated part need a TRCA permit and may be refused. Ask your insurer about flood coverage.
How to confirm. A TRCA property inquiry letter says which policies apply ($385, at least two weeks). Details
Ontario Regulation 41/24, TRCA Regulation LimitRavine and natural feature protection (11% of lot)
Needs a closer lookPart of the lot is in the area covered by the City's Ravine and Natural Feature Protection By-law. The City's map of the area was last published in 2019.
What it means. In that part, injuring or removing a tree of any size, grading, filling or dumping needs a City permit. Plans for a pool, addition or garden suite there may be refused.
How to confirm. Urban Forestry confirms where the protected area runs and whether work needs a permit. Details
Toronto Municipal Code, Chapter 658Natural Heritage System (36% of lot)
Good to knowPart of the lot is in the Natural Heritage System shown on Official Plan Map 9.
What it means. New buildings or additions in that part need a natural heritage impact study.
How to confirm. City Planning confirms the policies that apply. Details
City of Toronto Official Plan, Map 9Work or applications in progress
Good to knowRecent records on this lot: 26 143520 (Proposal for alterations to sprinkler system, 2026).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
14 records on file: more than at 100% of Toronto houses (median 0).
- Building permit26 143520Permit Issued
Proposal for alterations to sprinkler system.
May 7, 2026 · 60 MOBILE DR - Zoning review25 244191 ZZUClosedOct 23, 2025 · 60 MOBILE DR
- Building permit20 161333Closed
Revision 01 - Adding washrooms on lvl 2 lvlv 3 and lvl 5 and expansion of office on lvl 2 into tenant fit-out area.Three storey office building with a mechanical penthouse and a one storey below grade parking. The above grade levels will consist of office space and a meeting room, the below grade level will consist of car parking, office space and subsidiary storage and service spaces. Mass Timber Construction
Oct 17, 2024 · 60 MOBILE DR - Building permit23 225890Closed
Install First party ground sign**Teachers Federation**
Nov 14, 2023 · 60 MOBILE DR - Building permit23 219068Cancelled
Install 1 first party ground sign**60 Mobile Tenant sign**
Oct 26, 2023 · 60 MOBILE DR - Building permit23 116675Closed
ROOFTOP PV PANEL PART OF PERMIT 20 161333 BLD 00 NB
Mar 23, 2023 · 60 MOBILE DR - Building permit20 183100Closed
Demolish the existing one storey office building less (one) foundation wall is to remain - which will be shored.
Sep 17, 2020 · 60 MOBILE DR - Building permit20 171552Approved
Sentence 3.1.7.1.(1) requires the fire-resistance ratings for assemblies to be based on testing in accordance with CAN/ULC-S101 or on the basis of MMAH Supplementary Standard SB-2. Annex B of CSA O86 has been developed to determine fire-resistance ratings for mass timber elements based on previous testing to CAN/ULC-S101, but it is not yet part of the OBC acceptable solutions (although it is accepted in other jurisdictions). For this building, use of Annex B is proposed for the mass timber.
Jul 23, 2020 · 60 MOBILE DR
Show 6 older records
- Development application20 151703 NNY 16 OZClosed
Lifting the 'Hold' application to permit a new 9,500 square metres office building.
Jun 3, 2020 · 60 MOBILE DR · City file - Development application20 150765 NNY 16 SAClosed
Site Plan application to permit a new 9,500 square metre office building.
Jun 1, 2020 · 60 MOBILE DR · City file - Building permit11 232474Closed
Ontario Secondary School Teacher's Federation - Ground and 3rd floor
Jul 12, 2011 · 60 MOBILE DR - Building permit09 130626Closed
New Backflow Prevention Devices to office space.
May 13, 2009 · 60 MOBILE DR - Building permit08 175087Closed - Dormant
HVAC - Darton property advisors - Renovations
Jul 29, 2008 · 60 MOBILE DR - Zoning review02 148239 LTOClosedJun 19, 2002 · 60 MOBILE DR
Check before you build
Zoning not in By-law 569-2013
Needs a closer lookThis lot is not covered by the citywide zoning by-law's map. It is probably still governed by a former municipal by-law, which this tool does not read yet.
Zoning By-law 569-2013
Lot facts
- Area
- 9,566 m²
- Frontage
- 183.7 mestimated, irregular lot
- Depth
- 103.3 mestimated, irregular lot
- Street
- Mobile Dr
- Corner lot
- No
- Public lane
- None
- House footprint
- 2,393 m²roof up to 16.3 m
- Back yard
- 8.4 mhouse to rear lot line
- Side yards
- 44.1 m and 59.6 mhouse to side lot lines
- Buildings on the lot
- 4house, garage, sheds
- Max height
- —
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
Around this lot
- Minor variances approved
- 100%2 of 2 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 0
- Development applications
- 2
Within 300 m, last 10 years. 0 suite and multiplex permits: no more than at most Toronto houses (median 3). 2 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
Proposed demolition of showroom portion of existing auto dealership and construction of new 2-storey showroom addition.
1695 EGLINTON AVE E · Nov 3, 2022 · 401 m away - Minor varianceApproved
To construct a new office building.
57 MOBILE DR · Jun 10, 2021 · 74 m away - Minor varianceApproved
To construct an addition for Vehicle Storage and aTraining Room, and to remove the existing grass island near the street and widen the driveway.
25 OLD EGLINTON AVE · Oct 22, 2020 · 185 m away - Minor varianceApproved
To facilitate in the construction of a new six-storey, self-storage facility.
1 MOBILE DR · Oct 7, 2020 · 452 m away - Minor varianceApproved
To convert the existing warehouse and office space into a personal service shop.
32 MOBILE DR · Mar 19, 2014 · 259 m away
Latest activity nearby
- Building permit
Proposed fire alram system
44 MOBILE DR · Nov 2, 2026 · 154 m away - Building permit
Proposed interior alterations to second floor to accommodate new medical offices and staff.
44 MOBILE DR · Jun 25, 2026 · 154 m away - Building permit
Renovation of an existing janitor / storage room on the ground floor for a new universal washroom.
44 MOBILE DR · Jun 17, 2026 · 154 m away - Building permit
1 wall sign**GODIN**
35 MOBILE DR · Jun 3, 2026 · 203 m away - Building permit
1 Wall Sign
35 MOBILE DR · May 21, 2026 · 203 m away - Building permit
Proposal for interior alterations to an existing industrial/office building.
35 MOBILE DR · May 13, 2026 · 203 m away - Building permit
Proposal for alterations to sprinkler system.
60 MOBILE DR · May 7, 2026 · 17 m away - Building permit
1 ground sign**NEW CIRCLES**
44 MOBILE DR · Apr 10, 2026 · 154 m away - Building permit
1 GROUND SIGN**NEW CIRCLES**
44 MOBILE DR · Mar 23, 2026 · 154 m away - Building permit
1 Ground Sign
44 MOBILE DR · Mar 11, 2026 · 154 m away
Neighbourhood: Victoria Village
About the area around the lot, not the lot itself.
- Nearest station
- Wynford Station9 min walk
- Nearest TTC stop
- Eglinton Ave East at Credit Union Dr4 min walk
- Nearest cycling route
- Eglinton Ave EBike Lane, 3 min walk
- Nearest traffic count
- 2,841 vehicles in 8 hMobile Dr / Credit Union Dr, 180 m away, Oct 16, 2006
- Serious collisions within 500 m
- 02021–2026, killed or seriously injured
- Parks
- Charles Sauriol Conservation Area1 min walk
- Academy Soccer Field8 min walk
- Wigmore Park10 min walk
Schools within 1 km
- BRIGHTON SCHOOL Private 10 min walk
- IMAM ALI ISLAMIC CENTRE AND AL HAADI ACADEMY SCHOOL Private 14 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Victoria Village | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $68,000 | $84,500 |
| Households that own their home | 41% | 54% |
| Population (2021) | 17,365 | 16,813 |
| Homes built in 1960 or before | 29% | 29% |
| Homes needing major repairs | 7% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Victoria Village | City median |
|---|---|---|
| Assault | 591.2 | 636.3 |
| Robbery | 20.4 | 69.5 |
| Auto theft | 285.4 | 192.6 |
| Theft over $5,000 | 30.6 | 46.1 |
| Break and enter | 208.9 | 172.8 |
| Theft from vehicles | 178.4 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.