Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
Work or applications in progress
Good to knowRecent records on this lot: 22 136574 STE 09 SA (Site Plan Approval Application to redevelop the site with two mixed-use towers having h..., 2022); 21 230120 STE 09 CD (*** Draft Plan of Condominium for 753 dwelling units, 2021).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications8 development applications open within 300 m
Good to know8 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 21 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
3 records on file: more than at 81% of Toronto houses (median 0).
- Development application22 136574 STE 09 SAUnder Review
Site Plan Approval Application to redevelop the site with two mixed-use towers having heights of 15 and 17-storeys (plus mechanical). The proposal includes a total gross floor area of 48,925.5 square metres, 47,743.3 square metres is devoted to residential uses and 1,200 square metres for non-residential floor area.
Apr 21, 2022 · 20 CALEDONIA RD · City file - Development application21 230120 STE 09 CDUnder Review
*** Draft Plan of Condominium for 753 dwelling units.
Oct 25, 2021 · 20 CALEDONIA RD · City file - Development application21 175097 STE 09 OZClosed
Official Plan & zoning By-law Amendment Application to redevelop the site with two mixed-use towers having heights of 15 and 17-storeys (plus mechanical).
Jun 23, 2021 · 20 CALEDONIA RD · City file
Check before you build
Site-specific exception 900.11.10(612)
Needs a closer look25 site-specific rules and 25 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
On 1500-1536 St Clair Avenue West and 20-36 Caledonia Road, if the requirements of Section 12 and Schedule A of By-law 536-2022 are complied with, a building or structure may be constructed, used or enlarged in compliance with Regulations
- Rule B
to (X) below; (B) Despite Regulations 40.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum elevation of 131.5 metres and the elevation of the highest point of the building or structure
- Rule C
Despite Regulation 40.10.40.10(2)(A), the permitted maximum height of a building or structure is the number in metres following the letters "HT" as shown on Diagram 6 of By-law 536-2022
- Rule D
Despite Regulations 40.5.40.10(3) to (8), 40.5.75.1(2) and (C) above, the following building elements and structures may project beyond the permitted maximum height of a building shown on Diagram 6 of By-law 536-2022: (i) Building elements and structures on any roof such as elevator shafts, elevator overruns, stairs, stair towers, window washing equipment, building maintenance units, satellite dishes, lightning rods, chimneys, stacks, flues, vents, cooling towers, air intakes, mechanical, electrical, utility, or other equipment and devices used for the functional operation of the building , unenclosed heating equipment and power generators, the enclosure, screening or covering of equipment and devices, exoskeleton structures , antennas, cellular arrays, and related structural elements to a maximum of 8.0 metres; (ii) Building elements and structures on any roof such as indoor amenity space , washrooms, a green roof and related elements, canopies, awnings, solar shades and related structural elements to a maximum of 8.0 metres; (iii) Building elements and structures on any roof or at ground level used for outdoor amenity space or open air recreation including pergolas and playhouses, public art, solar energy devices, and access ramps, to a maximum of 3.0 metres; (iv) Building elements and structures such as terrace/balcony dividers, privacy screens, guardrails, railings, balustrades, parapets, architectural elements, landscaping , public art, light fixtures, privacy screens, and roof drainage to a maximum of 2.0 metres; (v) The total area of all equipment, structures or parts of a building referred to in (i) above, may cover no more than 80% of the area of the roof; (vi) Acoustical screens and sound barriers/walls; (vii) Safety and wind protection/mitigation features; and (viii) Crash walls and structures associated with rail safety mitigation
- Rule E
Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area is 49,000 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 48,000 square metres; (ii) the permitted maximum gross floor area for non-residential uses is 3,500 square metres; and (iii) the required minimum gross floor area for non-residential uses is 1,100 square metres
- Rule F
The permitted maximum number of dwelling units is 770, of which: (i) A minimum of 15 percent of the total dwelling units must contain a minimum of two-bedrooms; and (ii) A minimum of 10 percent of the total dwelling units must contain a minimum of three-bedrooms
- Rule G
Despite Regulation 40.10.40.1(1), residential use portions of a building are permitted to be located below, on or above the same storey as non-residential use portions of a building , however, no dwelling unit may be located below the portion of the storey closest in elevation to "finished grade"
- Rule H
Despite Regulation 40.10.40.1(2), the floor level of the portion of a first storey that accommodates a non-residential use must be within 0.2 metres of the ground measured at 1.0 metres outside of each pedestrian entrance to such non-residential space
- Rule I
Despite Regulation 40.10.40.10(5), the required minimum height of the first storey , as measured between the floor of the first storey and the ceiling of the first storey , is: (i) 3.0 metres for residential uses; and (ii) 4.5 metres for non-residential uses
- Rule J
In addition to the elements which reduce gross floor area listed in Regulation 40.5.40.40(3), the gross floor area of any building is also reduced by the area in a building used for: (i) All parking spaces provided at and above-ground any access thereto; (ii) Storage rooms, electrical, utility, mechanical, and ventilation areas and rooms at and above ground level; and (iii) All non-residential and residential gross floor area located below-ground level
- Rule K
Despite Regulation 40.10.40.50(1)(A) and (B), a building with 20 or more dwelling units must provide amenity space at the following rate: (i) at least 2.0 square metres for each dwelling unit as indoor amenity space ; and (ii) at least 2.0 square metres of outdoor amenity space for each dwelling unit of which 40.0 square metres must be in a location adjoining or directly accessible to the indoor amenity space
- Rule L
Despite Regulation 40.10.40.70(2), the required minimum building setbacks are as shown in metres on Diagram 6 of By-law 536-2022
- Rule M
Despite (L) above, the required minimum building setback for the portion of the storey closest in elevation to "finished grade", is: (i) 15.0 metres from the south lot lines along St. Clair Avenue West; (ii) 17.0 metres, exclusive of structural support columns, from the portions of the most westerly lot line located within 25 metres of the south lot lines along St. Clair Avenue West; and (iii) 20.0 metres, exclusive of structural support columns, from the portions of the most westerly lot line not described in (ii) above
- Rule N
For the purpose of this By-law and more particularly (G) and (M) above, "finished grade" means the elevation of the finished ground surface measured at the nearest pedestrian sidewalk/walking path or vehicular driveway
- Rule O
Despite Regulation 40.10.40.80(2), the required separation of main walls are as shown in metres on Diagram 6 of By-law 536-2022
- Rule P
Despite Clause 40.10.40.60, Regulations 5.10.40.70(1), 40.10.40.70(2) and (4) and 40.10.40.80(2) and (L), (M) and (O) above, the following elements and structures may encroach into the required minimum building setbacks and main wall separation distances as follows: (i) Decks, porches, patios and balconies, to a maximum extent of 1.8 metres; (ii) Architectural elements, light fixtures and window sills, to a maximum extent of 0.5 metres; (iii) Canopies and awnings, to a maximum extent of 3.0 metres; (iv) Landscaping , public art, structures and equipment used for outdoor amenity space or open air recreation, access ramps and associated railings, exterior stairs, air vents, air shafts/intakes, and site servicing features; (v) Crash walls and structures associated with rail safety mitigation; (vi) Safety and wind protection/mitigation features; and (vii) Acoustical screens and noise mitigation barriers
- Rule Q
Despite Regulation 200.5.10.1(1), 200.5.10.1(2) and Table 200.5.10.1, parking spaces must be provided in accordance with the following: (i) a minimum of 0 residential occupant parking spaces for each dwelling unit ; (ii) a maximum of 0.4 parking spaces for each dwelling unit ; (iii) a minimum of 0.1 residential visitor parking spaces for each dwelling unit ; and (iv) a minimum of 1.0 parking spaces for each 100 square metres of non-residential gross floor area
- Rule R
Despite Regulation 200.5.10.1(1) and (R) above, "car-share parking spaces" may replace parking spaces , subject to the following: (i) a reduction of 4 residential occupant parking spaces will be permitted for each "car-share parking space" provided and that the maximum reduction permitted be capped by the application of the following formula: (a) 4 multiplied by the total number of dwelling units divided by 60, rounded down to the nearest whole number; (ii) for the purpose of this exception, "car-share" means the practice whereby a number of people share the use of one or more motor vehicles and such "car-share" motor vehicles are made available to at least the occupants of the building for short-term rental, including hourly rental; and (iii) for the purpose of this exception, "car-share parking space" means a parking space exclusively reserved and signed for a vehicle used only for "car-share" purposes
- Rule S
Despite Clause 200.15.1 and Regulation 200.15.10(1), ten (10) accessible parking spaces must be provided in accordance with the following: (i) An accessible parking space must have the following minimum dimensions: (a) length of 5.6 metres; (b) width of 3.4 metres; and (c) vertical clearance of 2.1 metres; (ii) the entire length of an accessible parking space must be adjacent to a 1.5 metres wide accessible barrier free aisle or path as shown on Diagram 1 and Diagram 2 of By-law 579-2017; and (iii) Accessible parking spaces are required to be within 30 metres of a barrier free entrance to the building and passenger elevator that provides access to the first storey of the building
- Rule T
Despite Clauses 40.10.90.1, 220.5.10.1, and Regulation 220.5.1.10(1), loading spaces must be provided as follows: (i) A minimum of one (1) Type "G" loading space ; and (ii) A minimum of one (1) Type "B" loading space
- Rule U
Despite Regulation 230.5.1.10(10), "short-term" bicycle parking spaces may also be located in a stacked bicycle parking space
- Rule V
Despite Regulations 230.5.1.10(4)(A)(i) and (ii), 230.5.1.10(5)(A) and 230.5.1.10(4)(C), the required minimum dimensions of a stacked bicycle parking space are: (i) length of 1.6 metres; (ii) width of 0.3 metres; and (iii) vertical clearance of 1.1 metres
- Rule W
Despite Regulations 230.5.1.10(9) and 230.5.10.1(5), "long-term" bicycle parking spaces may be provided in any combination of vertical, horizontal or stacked positions, may be located in a secured room, and may be located on levels of the building below-ground level without being subject to any level increment requirement
- Rule X
Despite Regulations 230.5.1.10(10) and 230.40.1.20(2), "short-term" bicycle parking spaces may also be provided as stacked bicycle parking spaces , may be provided in any combination of vertical, horizontal or stacked positions, may be located in a secured room and within a building and may be located more than 30 metres from a pedestrian entrance to the building
- Rule Y
Despite Regulations 40.10.40.70(2), (4) and 40.10.40.80(2), no angular plane shall apply to the lands outlined by heavy lines in Diagram 1 of By-law 536-2022. Prevailing By-laws and Prevailing Sections: (None Apply)
- Older by-law A
On 1500-1536 St Clair Avenue West and 20-36 Caledonia Road, if the requirements of Section 12 and Schedule A of By-law 536-2022 are complied with, a building or structure may be constructed, used or enlarged in compliance with Regulations
- Older by-law B
to (X) below; (B) Despite Regulations 40.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum elevation of 131.5 metres and the elevation of the highest point of the building or structure
- Older by-law C
Despite Regulation 40.10.40.10(2)(A), the permitted maximum height of a building or structure is the number in metres following the letters "HT" as shown on Diagram 6 of By-law 536-2022
- Older by-law D
Despite Regulations 40.5.40.10(3) to (8), 40.5.75.1(2) and (C) above, the following building elements and structures may project beyond the permitted maximum height of a building shown on Diagram 6 of By-law 536-2022: (i) Building elements and structures on any roof such as elevator shafts, elevator overruns, stairs, stair towers, window washing equipment, building maintenance units, satellite dishes, lightning rods, chimneys, stacks, flues, vents, cooling towers, air intakes, mechanical, electrical, utility, or other equipment and devices used for the functional operation of the building , unenclosed heating equipment and power generators, the enclosure, screening or covering of equipment and devices, exoskeleton structures , antennas, cellular arrays, and related structural elements to a maximum of 8.0 metres; (ii) Building elements and structures on any roof such as indoor amenity space , washrooms, a green roof and related elements, canopies, awnings, solar shades and related structural elements to a maximum of 8.0 metres; (iii) Building elements and structures on any roof or at ground level used for outdoor amenity space or open air recreation including pergolas and playhouses, public art, solar energy devices, and access ramps, to a maximum of 3.0 metres; (iv) Building elements and structures such as terrace/balcony dividers, privacy screens, guardrails, railings, balustrades, parapets, architectural elements, landscaping , public art, light fixtures, privacy screens, and roof drainage to a maximum of 2.0 metres; (v) The total area of all equipment, structures or parts of a building referred to in (i) above, may cover no more than 80% of the area of the roof; (vi) Acoustical screens and sound barriers/walls; (vii) Safety and wind protection/mitigation features; and (viii) Crash walls and structures associated with rail safety mitigation
- Older by-law E
Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area is 49,000 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 48,000 square metres; (ii) the permitted maximum gross floor area for non-residential uses is 3,500 square metres; and (iii) the required minimum gross floor area for non-residential uses is 1,100 square metres
- Older by-law F
The permitted maximum number of dwelling units is 770, of which: (i) A minimum of 15 percent of the total dwelling units must contain a minimum of two-bedrooms; and (ii) A minimum of 10 percent of the total dwelling units must contain a minimum of three-bedrooms
- Older by-law G
Despite Regulation 40.10.40.1(1), residential use portions of a building are permitted to be located below, on or above the same storey as non-residential use portions of a building , however, no dwelling unit may be located below the portion of the storey closest in elevation to "finished grade"
- Older by-law H
Despite Regulation 40.10.40.1(2), the floor level of the portion of a first storey that accommodates a non-residential use must be within 0.2 metres of the ground measured at 1.0 metres outside of each pedestrian entrance to such non-residential space
- Older by-law I
Despite Regulation 40.10.40.10(5), the required minimum height of the first storey , as measured between the floor of the first storey and the ceiling of the first storey , is: (i) 3.0 metres for residential uses; and (ii) 4.5 metres for non-residential uses
- Older by-law J
In addition to the elements which reduce gross floor area listed in Regulation 40.5.40.40(3), the gross floor area of any building is also reduced by the area in a building used for: (i) All parking spaces provided at and above-ground any access thereto; (ii) Storage rooms, electrical, utility, mechanical, and ventilation areas and rooms at and above ground level; and (iii) All non-residential and residential gross floor area located below-ground level
- Older by-law K
Despite Regulation 40.10.40.50(1)(A) and (B), a building with 20 or more dwelling units must provide amenity space at the following rate: (i) at least 2.0 square metres for each dwelling unit as indoor amenity space ; and (ii) at least 2.0 square metres of outdoor amenity space for each dwelling unit of which 40.0 square metres must be in a location adjoining or directly accessible to the indoor amenity space
- Older by-law L
Despite Regulation 40.10.40.70(2), the required minimum building setbacks are as shown in metres on Diagram 6 of By-law 536-2022
- Older by-law M
Despite (L) above, the required minimum building setback for the portion of the storey closest in elevation to "finished grade", is: (i) 15.0 metres from the south lot lines along St. Clair Avenue West; (ii) 17.0 metres, exclusive of structural support columns, from the portions of the most westerly lot line located within 25 metres of the south lot lines along St. Clair Avenue West; and (iii) 20.0 metres, exclusive of structural support columns, from the portions of the most westerly lot line not described in (ii) above
- Older by-law N
For the purpose of this By-law and more particularly (G) and (M) above, "finished grade" means the elevation of the finished ground surface measured at the nearest pedestrian sidewalk/walking path or vehicular driveway
- Older by-law O
Despite Regulation 40.10.40.80(2), the required separation of main walls are as shown in metres on Diagram 6 of By-law 536-2022
- Older by-law P
Despite Clause 40.10.40.60, Regulations 5.10.40.70(1), 40.10.40.70(2) and (4) and 40.10.40.80(2) and (L), (M) and (O) above, the following elements and structures may encroach into the required minimum building setbacks and main wall separation distances as follows: (i) Decks, porches, patios and balconies, to a maximum extent of 1.8 metres; (ii) Architectural elements, light fixtures and window sills, to a maximum extent of 0.5 metres; (iii) Canopies and awnings, to a maximum extent of 3.0 metres; (iv) Landscaping , public art, structures and equipment used for outdoor amenity space or open air recreation, access ramps and associated railings, exterior stairs, air vents, air shafts/intakes, and site servicing features; (v) Crash walls and structures associated with rail safety mitigation; (vi) Safety and wind protection/mitigation features; and (vii) Acoustical screens and noise mitigation barriers
- Older by-law Q
Despite Regulation 200.5.10.1(1), 200.5.10.1(2) and Table 200.5.10.1, parking spaces must be provided in accordance with the following: (i) a minimum of 0 residential occupant parking spaces for each dwelling unit ; (ii) a maximum of 0.4 parking spaces for each dwelling unit ; (iii) a minimum of 0.1 residential visitor parking spaces for each dwelling unit ; and (iv) a minimum of 1.0 parking spaces for each 100 square metres of non-residential gross floor area
- Older by-law R
Despite Regulation 200.5.10.1(1) and (R) above, "car-share parking spaces" may replace parking spaces , subject to the following: (i) a reduction of 4 residential occupant parking spaces will be permitted for each "car-share parking space" provided and that the maximum reduction permitted be capped by the application of the following formula: (a) 4 multiplied by the total number of dwelling units divided by 60, rounded down to the nearest whole number; (ii) for the purpose of this exception, "car-share" means the practice whereby a number of people share the use of one or more motor vehicles and such "car-share" motor vehicles are made available to at least the occupants of the building for short-term rental, including hourly rental; and (iii) for the purpose of this exception, "car-share parking space" means a parking space exclusively reserved and signed for a vehicle used only for "car-share" purposes
- Older by-law S
Despite Clause 200.15.1 and Regulation 200.15.10(1), ten (10) accessible parking spaces must be provided in accordance with the following: (i) An accessible parking space must have the following minimum dimensions: (a) length of 5.6 metres; (b) width of 3.4 metres; and (c) vertical clearance of 2.1 metres; (ii) the entire length of an accessible parking space must be adjacent to a 1.5 metres wide accessible barrier free aisle or path as shown on Diagram 1 and Diagram 2 of By-law 579-2017; and (iii) Accessible parking spaces are required to be within 30 metres of a barrier free entrance to the building and passenger elevator that provides access to the first storey of the building
- Older by-law T
Despite Clauses 40.10.90.1, 220.5.10.1, and Regulation 220.5.1.10(1), loading spaces must be provided as follows: (i) A minimum of one (1) Type "G" loading space ; and (ii) A minimum of one (1) Type "B" loading space
- Older by-law U
Despite Regulation 230.5.1.10(10), "short-term" bicycle parking spaces may also be located in a stacked bicycle parking space
- Older by-law V
Despite Regulations 230.5.1.10(4)(A)(i) and (ii), 230.5.1.10(5)(A) and 230.5.1.10(4)(C), the required minimum dimensions of a stacked bicycle parking space are: (i) length of 1.6 metres; (ii) width of 0.3 metres; and (iii) vertical clearance of 1.1 metres
- Older by-law W
Despite Regulations 230.5.1.10(9) and 230.5.10.1(5), "long-term" bicycle parking spaces may be provided in any combination of vertical, horizontal or stacked positions, may be located in a secured room, and may be located on levels of the building below-ground level without being subject to any level increment requirement
- Older by-law X
Despite Regulations 230.5.1.10(10) and 230.40.1.20(2), "short-term" bicycle parking spaces may also be provided as stacked bicycle parking spaces , may be provided in any combination of vertical, horizontal or stacked positions, may be located in a secured room and within a building and may be located more than 30 metres from a pedestrian entrance to the building
- Older by-law Y
Despite Regulations 40.10.40.70(2), (4) and 40.10.40.80(2), no angular plane shall apply to the lands outlined by heavy lines in Diagram 1 of By-law 536-2022. Prevailing By-laws and Prevailing Sections: (None Apply)
Lot facts
- Area
- 189 m²
- Frontage
- 12.4 m
- Depth
- 15.3 m
- Street
- Caledonia Rd
- Corner lot
- No
- Public lane
- None
- Max height
- 16 m
- Max lot coverage
- —
- Zone CR 3.0 (c1.0; r2.5) SS2 (x612) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
Around this lot
- Minor variances approved
- 94%29 of 31 decisions
- Garden suite permits
- 1
- Laneway suite permits
- 2
- Multiplex permits
- 3
- Development applications
- 10
Within 300 m, last 10 years. 6 suite and multiplex permits: more than at 64% of Toronto houses (median 3). 31 variance decisions: more than at 64% of Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To alter the development standards for the mixed-use development containing two buildings (Building A and Building B) with a shared podium and one 16-storey and one 18-storey tower (approved under Site Specific Zoning By-Law 535-2022 and 536-2022) by increasing the total number of dwelling units from 770 to 776 units, reducing the setback at the fifteenth storey of Building B (fronting Caledonia Road), and to permit parking space obstructions due to structural columns. This application is associated with Site Plan Application #22 136574 STE 09 SA that is currently under review.
1500 ST CLAIR AVE W · Jul 31, 2024 · 11 m away - Minor varianceApproved
To construct a new Library (Toronto Public Library).
1748 ST CLAIR AVE W · Sep 15, 2016 · 463 m away - Minor varianceApproved
To construct a three-storey residential addition above an existing one-storey commercial building. A total of six dwelling units is proposed.
1700 ST CLAIR AVE W · Aug 13, 2015 · 346 m away - Minor varianceApproved
To construct a one-storey front addition.
1500 ST CLAIR AVE W · Aug 13, 2015 · 11 m away - Minor varianceApproved
To construct a second and third-storey addition above the existing commercial building.
1743 ST CLAIR AVE W · Jul 16, 2015 · 440 m away
Latest activity nearby
- Building permit
Proposal for interior alteration to convert from SFD to two units house and new third floor dormer addition.
15 CALEDONIA RD · Oct 13, 2026 · 50 m away - Building permit
Proposal for a backwater valve
68 CALEDONIA RD · Oct 9, 2026 · 175 m away - Building permit
Proposal to reconstruct the rear addition.
54 EXETER ST · Sep 24, 2026 · 267 m away - Building permit
TO CONSTRUCT A NEW DETACHED GARAGE STRUCTURE ABUTTING LANEWAY
89 MCROBERTS AVE · Sep 7, 2026 · 273 m away - Building permit
Rev 01: Revision to add interior alterations to second floor (not in original scope) and changes to the main floor and basement as shown in bubbles. Proposal for interior alterations to the ground and basement levels for new restaurant, greater than 30 seats.
1666 ST CLAIR AVE W · Aug 10, 2026 · 246 m away - Building permit
Proposal for second unit in basement, as well as front and rear addition.
17 GILBERT AVE · Jun 29, 2026 · 290 m away - Building permit
Party wall admin permit for work at 19 Exeter St - 26-155267
21 EXETER ST · Jun 22, 2026 · 263 m away - Building permit
Proposal for multiple projects (alterations, basement underpinning and walk-out stair, detached rear garage).
19 EXETER ST · Jun 11, 2026 · 261 m away - Minor varianceApproved
To legalize and to maintain the existing rear one-storey addition (attached shed), which was constructed without an authorized building permit. Also, to convert the existing basement level into a residential dwelling unit. There will be a total of two residential dwelling units on this lot (one unit occupying the ground and second levels, and one unit occupying the basement level).
17 GILBERT AVE · May 27, 2026 · 290 m away - Building permit
Supply and install sanitary line back water valve
56 PRESCOTT AVE · May 27, 2026 · 228 m away
Neighbourhood: Corso Italia-Davenport
About the area around the lot, not the lot itself.
- Nearest station
- Caledonia Station33 min walk
- Nearest TTC stop
- St Clair Ave West at Caledonia Rd West Side1 min walk
- Nearest cycling route
- Silverthorn AveBike Lane - Contraflow, 7 min walk
- Nearest traffic count
- 26,441 vehicles in 14 hSt Clair Ave W / Caledonia Rd / Caledonia Park Rd / Earlscourt Park Trl, 60 m away, Oct 18, 2025
- Serious collisions within 500 m
- 32021–2026, killed or seriously injured: 0 fatal, 3 with pedestrians, 0 with cyclists
- Parks
- Earlscourt Park1 min walk
- Don Panos Parkette2 min walk
- Prescott Parkette3 min walk
Schools within 1 km
- ST PAUL VI CATHOLIC ELEMENTARY SCHOOL English Separate 5 min walk
- CARLETON VILLAGE JR & SR PUBLIC SCHOOL English Public 9 min walk
- GENERAL MERCER JR PUBLIC SCHOOL English Public 13 min walk
- ST NICHOLAS OF BARI CATHOLIC ELEMENTARY SCHOOL English Separate 15 min walk
- ECOLE ELEMENTAIRE CHARLES SAURIOL French Public 15 min walk
- STELLA MARIS CATHOLIC ELEMENTARY SCHOOL English Separate 15 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Corso Italia-Davenport | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $94,000 | $84,500 |
| Households that own their home | 63% | 54% |
| Population (2021) | 13,200 | 16,813 |
| Homes built in 1960 or before | 72% | 29% |
| Homes needing major repairs | 7% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Corso Italia-Davenport | City median |
|---|---|---|
| Assault | 995 | 636.3 |
| Robbery | 91.7 | 69.5 |
| Shootings | 7.1 | 10.5 |
| Auto theft | 197.6 | 192.6 |
| Theft over $5,000 | 35.3 | 46.1 |
| Break and enter | 197.6 | 172.8 |
| Theft from vehicles | 324.6 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.