Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
7 development applications open within 300 m
Good to know7 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 40 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
No permits, applications or Committee of Adjustment files on this lot in the City's open records.
Check before you build
Site-specific exception 900.11.10(814)
Needs a closer look18 site-specific rules and 18 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule B
to (S) below; (B) Despite Regulations 40.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum elevation of 189.45 metres and the highest point of the building or structure
- Rule C
Regulation 40.10.30.40(1)(A) with respect to maximum lot coverage does not apply
- Rule D
Despite Regulation 40.10.40.1(1), residential uses are permitted to be located on the first storey provided they have direct access to Wedgewood Drive
- Rule E
Despite Regulation 40.10.40.10(3) and (7), the permitted maximum height of a building or structure is the number following the HT symbol in metres as shown on Diagram 3 of By-law 89-2023(OLT)
- Rule F
Despite Regulations 40.5.40.10(3) to (8) and (E) above, the following equipment and structures may project beyond the permitted maximum height of a building : (i) wind screens, elevator overruns, parapets, awnings, fences, guard rails, railings and dividers, pergolas, trellises, balustrades, eaves, screens, roof drainage, window sills, window washing equipment, chimneys, vents, terraces, lightning rods, light fixtures, architectural features, and elements of a green roof , may project above the height limits to a maximum of 3.0 metres; (ii) stairs and stair enclosures, may project above the height limits to a maximum of 3.5 metres; and (iii) mechanical equipment and any associated structures , may project above the height limits to a maximum of 6.0 metres
- Rule G
Despite Regulation 40.10.40.10(5), the required minimum height of the first storey , as measured between the floor of the first storey and the ceiling of the first storey, is 4.0 metres
- Rule H
Despite Regulations 40.10.40.40(1) the permitted maximum gross floor area of all buildings and structures on the lot is 31,000 square metres, of which; (i) the required minimum gross floor area for non-residential uses is 500 square metres
- Rule I
Despite Regulation 40.10.40.50(1), amenity space must be provided at a minimum rate of 3.86 square metres for each dwelling unit of which at least 2.0 square metres for each dwelling unit is indoor amenity space
- Rule J
Despite Regulation 40.10.40.70 (3), the required minimum building setbacks are as shown in metres on Diagram 3 of By-law 89-2023(OLT)
- Rule K
Despite Regulations 40.10.40.60(1), (2), and (3), and (J) above, the following elements may encroach into the required minimum building setbacks and separation distances: (i) balconies to a maximum extent of 2.5 metres; (ii) eaves, building cornices, light fixtures, ornamental and architectural elements, parapets, railings and fences, planters, trellises, window sills, underground garage ramps, to a maximum extent of 2.0 metres; (iii) Canopies to a maximum extent of 4.5 metres
- Rule L
Despite Regulations 40.10.50.10(2) and (3), fencing and soft landscaping is not required along the rear lot line
- Rule M
Despite Regulations 40.5.80.10(1), 200.5.10.1(1) and Table 200.5.10.1, parking spaces must be provided in accordance with the following: (i) a minimum of 0.41 parking spaces per dwelling unit for residential occupant parking spaces ; (ii) a minimum of 0.10 parking spaces per dwelling unit for residential visitor parking spaces ; (iii) no parking spaces are required for non-residential uses; and (iv) a maximum of 15 parking spaces required by (i) and (ii) above may be located within 50 metres of the lot
- Rule N
Despite Regulation 200.5.10.1(1), "car-share parking spaces" may replace parking spaces otherwise required for residential occupants, subject to the following: (i) A reduction of four residential occupant parking spaces will be permitted for each "car-share parking space" provided and that the maximum reduction permitted be capped by the application of the following formula: (a) four multiplied by the total number of dwelling units divided by 60, and rounded down to the nearest whole number; (ii) For the purpose of this exception, "car-share" means the practice where a number of people share the use of one or more cars that are owned by a profit or non-profit car-sharing organization and where such organization may require that use of cars be reserved in advance, charge fees based on time and/or kilometres driven, and set membership requirements of the car-sharing organization, including the payment of a membership fee that may or may not be refundable; (iii) For the purpose of this exception, "car-share parking space" means a parking space that is exclusively reserved and signed for a vehicle only for "car-share" purposes
- Rule O
Despite Regulation 200.15.1(1), an accessible parking space must have the following minimum dimensions: (i) Length of 5.6 metres; (ii) Width of 3.4 metres; and (iii) Vertical clearance of 2.1 metres
- Rule P
Despite Clause 220.5.10.1(3), no loading space is required for non-residential uses
- Rule Q
Despite Regulation 230.5.1.10(4), each stacked bicycle parking space must have a minimum width of 0.46 metres, and a minimum length of 1.8 metres
- Rule R
Despite Regulation 230.5.1.10(9)(A)(iii) and (B)(iii), "long-term" bicycle parking spaces may be located: (i) On levels of the building below-ground
- Rule S
Despite Regulation 230.40.1.20(2), "short-term" bicycle parking spaces may be located more than 30 metres from a pedestrian entrance to the building on the lot . Prevailing By-laws and Prevailing Sections: (None Apply)
- Older by-law B
to (S) below; (B) Despite Regulations 40.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum elevation of 189.45 metres and the highest point of the building or structure
- Older by-law C
Regulation 40.10.30.40(1)(A) with respect to maximum lot coverage does not apply
- Older by-law D
Despite Regulation 40.10.40.1(1), residential uses are permitted to be located on the first storey provided they have direct access to Wedgewood Drive
- Older by-law E
Despite Regulation 40.10.40.10(3) and (7), the permitted maximum height of a building or structure is the number following the HT symbol in metres as shown on Diagram 3 of By-law 89-2023(OLT)
- Older by-law F
Despite Regulations 40.5.40.10(3) to (8) and (E) above, the following equipment and structures may project beyond the permitted maximum height of a building : (i) wind screens, elevator overruns, parapets, awnings, fences, guard rails, railings and dividers, pergolas, trellises, balustrades, eaves, screens, roof drainage, window sills, window washing equipment, chimneys, vents, terraces, lightning rods, light fixtures, architectural features, and elements of a green roof , may project above the height limits to a maximum of 3.0 metres; (ii) stairs and stair enclosures, may project above the height limits to a maximum of 3.5 metres; and (iii) mechanical equipment and any associated structures , may project above the height limits to a maximum of 6.0 metres
- Older by-law G
Despite Regulation 40.10.40.10(5), the required minimum height of the first storey , as measured between the floor of the first storey and the ceiling of the first storey, is 4.0 metres
- Older by-law H
Despite Regulations 40.10.40.40(1) the permitted maximum gross floor area of all buildings and structures on the lot is 31,000 square metres, of which; (i) the required minimum gross floor area for non-residential uses is 500 square metres
- Older by-law I
Despite Regulation 40.10.40.50(1), amenity space must be provided at a minimum rate of 3.86 square metres for each dwelling unit of which at least 2.0 square metres for each dwelling unit is indoor amenity space
- Older by-law J
Despite Regulation 40.10.40.70 (3), the required minimum building setbacks are as shown in metres on Diagram 3 of By-law 89-2023(OLT)
- Older by-law K
Despite Regulations 40.10.40.60(1), (2), and (3), and (J) above, the following elements may encroach into the required minimum building setbacks and separation distances: (i) balconies to a maximum extent of 2.5 metres; (ii) eaves, building cornices, light fixtures, ornamental and architectural elements, parapets, railings and fences, planters, trellises, window sills, underground garage ramps, to a maximum extent of 2.0 metres; (iii) Canopies to a maximum extent of 4.5 metres
- Older by-law L
Despite Regulations 40.10.50.10(2) and (3), fencing and soft landscaping is not required along the rear lot line
- Older by-law M
Despite Regulations 40.5.80.10(1), 200.5.10.1(1) and Table 200.5.10.1, parking spaces must be provided in accordance with the following: (i) a minimum of 0.41 parking spaces per dwelling unit for residential occupant parking spaces ; (ii) a minimum of 0.10 parking spaces per dwelling unit for residential visitor parking spaces ; (iii) no parking spaces are required for non-residential uses; and (iv) a maximum of 15 parking spaces required by (i) and (ii) above may be located within 50 metres of the lot
- Older by-law N
Despite Regulation 200.5.10.1(1), "car-share parking spaces" may replace parking spaces otherwise required for residential occupants, subject to the following: (i) A reduction of four residential occupant parking spaces will be permitted for each "car-share parking space" provided and that the maximum reduction permitted be capped by the application of the following formula: (a) four multiplied by the total number of dwelling units divided by 60, and rounded down to the nearest whole number; (ii) For the purpose of this exception, "car-share" means the practice where a number of people share the use of one or more cars that are owned by a profit or non-profit car-sharing organization and where such organization may require that use of cars be reserved in advance, charge fees based on time and/or kilometres driven, and set membership requirements of the car-sharing organization, including the payment of a membership fee that may or may not be refundable; (iii) For the purpose of this exception, "car-share parking space" means a parking space that is exclusively reserved and signed for a vehicle only for "car-share" purposes
- Older by-law O
Despite Regulation 200.15.1(1), an accessible parking space must have the following minimum dimensions: (i) Length of 5.6 metres; (ii) Width of 3.4 metres; and (iii) Vertical clearance of 2.1 metres
- Older by-law P
Despite Clause 220.5.10.1(3), no loading space is required for non-residential uses
- Older by-law Q
Despite Regulation 230.5.1.10(4), each stacked bicycle parking space must have a minimum width of 0.46 metres, and a minimum length of 1.8 metres
- Older by-law R
Despite Regulation 230.5.1.10(9)(A)(iii) and (B)(iii), "long-term" bicycle parking spaces may be located: (i) On levels of the building below-ground
- Older by-law S
Despite Regulation 230.40.1.20(2), "short-term" bicycle parking spaces may be located more than 30 metres from a pedestrian entrance to the building on the lot . Prevailing By-laws and Prevailing Sections: (None Apply)
2 parts for other addresses
- A On 5995 and 5997 Yonge Street, if the requirements of By-law 89-2023(OLT) are complied with, a building or structure may be constructed, used, or enlarged, in …
- A On 5995 and 5997 Yonge Street, if the requirements of By-law 89-2023(OLT) are complied with, a building or structure may be constructed, used, or enlarged, in …
Lot facts
- Area
- 913 m²
- Frontage
- 20 m
- Depth
- 48.2 m
- Street
- Yonge St
- Corner lot
- No
- Public lane
- None
- Max height
- 10.5 m
- Max lot coverage
- 33%
Around this lot
- Minor variances approved
- 100%10 of 10 decisions
- Garden suite permits
- 2
- Laneway suite permits
- 0
- Multiplex permits
- 2
- Development applications
- 10
Within 300 m, last 10 years. 4 suite and multiplex permits: more than at 54% of Toronto houses (median 3). 10 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To convert the existing ancillary building (3-car detached garage) at the rear of the property into a take-out pizza restaurant.
6020-6022 YONGE ST · Oct 15, 2026 · 81 m away - Minor varianceApproved
To permit revisions to the approved 13-storey mid-rise mixed-use development, and Specifically seek relief from the site-specific By-law No. 1037-2022 to increase height, number of residential units, gross floor area and reduce building set backs and vehicular parking rates. (the application was deferred from the hearing of 20 June 2024)
6150 YONGE ST · Aug 1, 2024 · 410 m away - Minor varianceApproved
To permit modifications of gross floor area, building height, and parking requirements for an approved mixed-use building.
5995 YONGE ST · Jun 8, 2023 · 21 m away - Minor varianceApproved
To permit revisions to the approved 13 storey mid-rise, mixed-use development on the subject site.
6150 YONGE ST · Jun 8, 2023 · 410 m away - Minor varianceApproved
To permit interior alteration to the existing building to permit a coffee shop use.
6117-6123 YONGE ST · Oct 1, 2015 · 322 m away
Latest activity nearby
- Building permit
Proposal for repairs to the level P1 of the underground parking garage
6061 YONGE ST · Nov 17, 2026 · 172 m away - Building permit
Interior alterations to 6005 Yonge Street, Unit A
5999-6023 YONGE ST · Nov 12, 2026 · 67 m away - Building permit
Proposal for interior alterations to a new restaurant and patron area, less than 30 seats for new tenant.Convenience address is 6017 Yonge St.
5999-6023 YONGE ST · Oct 23, 2026 · 67 m away - Minor varianceApproved
To convert the existing ancillary building (3-car detached garage) at the rear of the property into a take-out pizza restaurant.
6020-6022 YONGE ST · Oct 15, 2026 · 81 m away - Building permit
Proposal to demolish existing building and construct a new three storey four unit detached dwelling and a rear garden suite.
22 EVERINGHAM CRT · Oct 8, 2026 · 251 m away - Building permit
Proposal to demolish existing building and construct a new three storey four unit detached dwelling and a rear garden suite.
22 EVERINGHAM CRT · Oct 8, 2026 · 251 m away - Zoning review
Notice Sent
6020-6022 YONGE ST · Aug 11, 2026 · 90 m away - Building permit
1 ground sign with LED sign and 4 static sign panels.
5959 YONGE ST · Jul 16, 2026 · 68 m away - Zoning review
Closed
6020-6022 YONGE ST · Jun 16, 2026 · 90 m away - Building permit
Supply and install (3) like for like HVAC roof top units
5928 YONGE ST · Jun 5, 2026 · 162 m away
Neighbourhood: Newtonbrook East
About the area around the lot, not the lot itself.
- Nearest station
- Finch Station16 min walk
- Nearest TTC stop
- Yonge St at Patricia Ave2 min walk
- Nearest cycling route
- Newtonbrook Park TrlMulti-Use Trail - Connector, 6 min walk
- Nearest traffic count
- 37,617 vehicles in 14 hYonge St / Wedgewood Dr, 50 m away, Oct 7, 2026
- Serious collisions within 500 m
- 62021–2026, killed or seriously injured: 1 fatal, 2 with pedestrians, 1 with cyclists
- Parks
- Centre Park4 min walk
- Goulding Park5 min walk
- Newtonbrook Park6 min walk
Schools within 1 km
- DREWRY ACADEMY Private 4 min walk
- ALPHA QUALITY EDUCATION SCHOOL Private 6 min walk
- DREWRY SECONDARY SCHOOL English Public 6 min walk
- AVONDALE SECONDARY ALTERNATIVE SCHOOL English Public 8 min walk
- MONSEIGNEUR DE CHARBONNEL CATHOLIC SECONDARY SCHOOL French Separate 9 min walk
- WILLOWDALE CHRISTIAN SCHOOL Private 11 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Newtonbrook East | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $80,000 | $84,500 |
| Households that own their home | 62% | 54% |
| Population (2021) | 15,345 | 16,813 |
| Homes built in 1960 or before | 17% | 29% |
| Homes needing major repairs | 5% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Newtonbrook East | City median |
|---|---|---|
| Assault | 554 | 636.3 |
| Robbery | 60.3 | 69.5 |
| Auto theft | 252.3 | 192.6 |
| Theft over $5,000 | 49.4 | 46.1 |
| Break and enter | 170 | 172.8 |
| Theft from vehicles | 170 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.