HousePrecheckCheck an address

5509 Dundas St WToronto · zoning, lot size and permit records

(H) CR 0.6 (c0.6; r0.0) SS3 (x302)30.8 × 67.7 m1,780 m²on Dundas St W

Not a home

Land without a building

The City's 3D model of buildings shows nothing standing on this parcel: vacant land, a parking lot or a yard. It is not a home for sale, so the house checks and the pre-offer report do not apply.

Looking at a house nearby? What this means for you

  • Empty land or parkingWhat gets built here matters most to the street: read the applications on it and around it below.
  • Permits or applications open on this parcelRecent records on this lot: 25 233678 (Deferred Fees from folder 21 233678 (RSN-5019188) ZoningProcess RSN 69679262, 2025); 18 149707 WET 05 SA (Proposal for a 22 storey mixed-use building including 6 affordable rental dwelling unit..., 2018). Larger work can mean noise and trucks next door; read what each one is for.
  • 3 development applications open within 300 m, up to 40 storeysNew buildings may go up around here in the next years. More change nearby than at 95% of Toronto houses.
N20 m
30.8 m frontage67.7 m deep

Before you offer

From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.

  • Work or applications in progress

    Good to know

    Recent records on this lot: 25 233678 (Deferred Fees from folder 21 233678 (RSN-5019188) ZoningProcess RSN 69679262, 2025); 18 149707 WET 05 SA (Proposal for a 22 storey mixed-use building including 6 affordable rental dwelling unit..., 2018).

    What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.

    How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details

    City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications
  • 3 development applications open within 300 m

    Good to know

    3 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 40 storeys. They are listed under Around this lot.

    What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.

    How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details

    City of Toronto, Development Applications

Not in these records

  • Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
  • Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.

History of this lot

9 records on file: more than at 99% of Toronto houses (median 0).

  • Building permit26 114190Approved

    Alternative Solution to address the extended fire hose coverage utilizing the requirements of the 2024 ontario building code and nfpa 14.

    Feb 6, 2026 · 5509 DUNDAS ST W
  • Building permit25 233678Open

    Deferred Fees from folder 21 233678 (RSN-5019188) ZoningProcess RSN 69679262

    Oct 2, 2025 · 5509 DUNDAS ST W
  • Building permit25 102833Approved

    Alternative Solution for standpipe in connection with building permit No. 21 233678 BLD 00 NB

    Jan 9, 2025 · 5509 DUNDAS ST W
  • Development application24 251625 WET 03 OZClosed

    Proposed Zoning By-law Amendment application to lift the Holding Provision (H) in association with the proposed development at 5507 & 5509 Dundas Street West. Holding Provisions are included in the approved zoning by-laws (By-law 55-2021 & By-law 56-2021).

    Dec 18, 2024 · 5507 DUNDAS ST W · City file
  • Building permit21 233678Superseded

    Part Permit - Proposal to construct a 23 storey mixed use development with 259 dwelling units, retail on grade and 3 levels of underground garage

    Dec 31, 2021 · 5509 DUNDAS ST W
  • Zoning review18 133602 PRZClosed
    Oct 26, 2018 · 5509 DUNDAS ST W
  • Zoning review18 149707 PSPClosed
    Apr 30, 2018 · 5509 DUNDAS ST W
  • Development application18 149707 WET 05 SANOAC Issued

    Proposal for a 22 storey mixed-use building including 6 affordable rental dwelling units, a POPS and a laneway easement.

    Apr 27, 2018 · 5509 DUNDAS ST W · City file
Show 1 older records
  • Development application18 133602 WET 05 OZClosed

    The Zoning By-law Amendment application to permit the redevelopment of the Subject Lands for a 21-storey mixed use building. The proposed development would provide for a total of 21934 square metres of gross floor area comprised of 20,725 square metres of residential uses (95% of the total GFA), 1,209 square metres of at-grade retail uses.

    Mar 23, 2018 · 5509 DUNDAS ST W · City file

Check before you build

  • Site-specific exception 900.11.10(302)

    Needs a closer look

    19 site-specific rules and 19 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.

    Zoning By-law 569-2013, Chapter 900
  • Holding provision (H)

    Needs a closer look

    Development is on hold until the conditions of the holding by-law are met.

    Zoning By-law 569-2013
Exception 900.11.10(302)Applies

These parts of the exception apply to this lot's address.

  1. Rule A

    On lands municipally known as 5507 and 5509 Dundas Street West, if the requirements of By-law 55-2021 are complied with, a mixed use building and structures may be erected, used or enlarged in compliance with

  2. Rule B

    to (S) below; (B) Despite Regulations 40.5.40.10 (1) and (2), the height of a building or structure is the vertical distance between the Canadian Geodetic Datum elevation of 127.14 metres and the highest point of the building or structure

  3. Rule C

    Despite Regulation 40.5.40.60 (1) and (B) above, a canopy or, awning with or without structural support may encroach into a required minimum building setback that abuts a street

  4. Rule D

    Regulation 40.10.40.1(1), requiring residential uses to be located above nonresidential uses, does not apply.

  5. Rule E

    Despite Regulation 40.10.40.10(3), the permitted maximum height of any portion of the mixed use building , is the numerical value, in metres, following the letters "HT" as shown on Diagram 6 of By-law 55-2021.

  6. Rule F

    Despite Regulation 40.10.40.10(7), the permitted maximum number of storeys in any portion of the mixed use building is the numerical value followed by the letters "ST" as shown on Diagram 6 of By-law 55-2021.

  7. Rule G

    Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area of the mixed use building is 22,500 square metres, of which: (i) the residential gross floor area must not exceed 21,200 square metres; and (ii) the non-residential gross floor area must not exceed 1,300 square metres

  8. Rule H

    Non-residential gross floor area is not permitted above the first storey excluding mezzanine space.

  9. Rule I

    Area devoted to non-residential floor area must: (i) have a main pedestrian entrance: (a) located parallel to the lot line abutting Dundas Street West; and (b) located within 0.2 metres of the ground measured at the lot line abutting the street directly opposite the entrance; and (ii) have a minimum 6 metre finished floor to underside of interior finished ceiling height for the Dundas Street West frontage for a depth of 6 metres and a minimum of 3.6 metres for the remaining depth from the Dundas Street frontage.

  10. Rule J

    Dwelling units in a mixed use building are not permitted to front on the portion of the first storey facing the lot line abutting Dundas Street West.

  11. Rule K

    A minimum of ten percent (10 percent) of all dwelling units in the mixed use building must be three bedroom units, of which: (i) all required three bedroom units must have be a minimum of 100 square metres of interior floor area excluding mechanical space; and (ii) a minimum of fifty percent (50 percent) of the required three bedroom units must have a minimum of 106 square metres of interior floor area excluding mechanical space.

  12. Rule L

    A minimum of fifteen percent (15 percent) of all dwelling units in the mixed use building must be two bedroom units, of which all required two bedroom units must have a minimum of 87 square metres of interior floor area excluding mechanical space.

  13. Rule M

    A maximum of 265 dwelling units are permitted in the mixed use building .

  14. Rule N

    Any portion of the building above a height of 28.7 metres must not exceed 750 square metres, measured from exterior wall to exterior wall, excluding balconies.

  15. Rule O

    Despite Clause 40.10.40.70, the required minimum building setbacks are shown on Diagram 7 of By-law 55-2021

  16. Rule P

    Despite Regulation 40.5.40.10(4) and (E) above: (i) a mechanical penthouse is limited in accordance with the area identified as mechanical penthouse in Diagram 6 of By-law 55-2021; (ii) mechanical equipment and stair enclosures may project to a maximum of 6.0 metres above the applicable height limit and storey limit shown on Diagram 6 of By-law 55-2021; (iii) terraces and balcony guards, elements of a green roof and insulation and roof surface materials, planters, railings, parapets, and ornamental architectural features, may project to a maximum of 3.0 metres above the applicable height limit shown on Diagram 6 of By-law 55-2021; (iv) window washing equipment may project to a maximum of 8.0 metres above the applicable height limit shown on Diagram 6 of By-law 55-2021; (v) a ladder for maintenance purposes may project to a maximum of 1.2 metres above the applicable height limit shown on Diagram 6 of By-law 55-2021; and (vi) public art may project above the applicable height limit.

  17. Rule Q

    Despite Clause 40.10.40.70, Regulation 40.10.40.70(3) and (O) above, the following elements are permitted to encroach from the building or structure into the required building setbacks shown on Diagram 7 of By-law 55-2021; (i) eaves, cornices, columns, landscape features, wheelchair ramps, light fixtures, stairs and stair enclosures, balustrades, guardrails, bollards, awnings, arcades, canopies, raised planters, patios, retaining walls, fences, vents, screens, underground parking ramp and associated structures , damper equipment, window washing equipment to a maximum of 2.5 metres; (ii) balconies and bay windows to a maximum of 2.2 metres; (iii) structures used for outside or open air recreation, safety, noise mitigation, and wind mitigation, to a maximum of 1.6 metres; (iv) ornamental, decorative or architectural elements to a maximum of 3.1 metres; and (v) public art.

  18. Rule R

    Despite Regulation 200.5.10.1(1), parking spaces must be provided and maintained in accordance with the following: (i) a minimum of 0.57 parking spaces per dwelling unit must be provided for the use of the residents; (ii) a minimum of 0.1 parking spaces per dwelling unit must be provided for visitors to the residential use portion of the building ; (iii) a minimum of 0.75 parking spaces must be provided per 100 square metres of non-residential gross floor area ; (iv) Despite (R)(i) above, the minimum number of parking spaces required to be provided for the use of residents of the building may be reduced in accordance with a reduction of 4 resident parking spaces for each "car-share" parking space provided, to a maximum reduction of 12 parking spaces ; and (v) For the purposes of exception (R)(iv) above, "car-share" parking space means a parking space that is reserved and actively used for car-sharing and must be for the exclusive use of the residents of the building . "Car-share" means the practice where a number of people share the use of one or more cars that are owned by a profit or non-profit car-sharing organization and where such organization may require that use of cars to be reserved in advance, charge fees based on time and/or kilometres driven, and set membership requirements of the car-sharing organization, including the payment of a membership fee that may or may not be refundable.

  19. Rule S

    The lands identified with the symbol "(H)" in the zone label on Diagram 2 of By-law 55-2021 are restricted in use as specified by section 9 of By-law 55-2021. Prevailing By-laws and Prevailing Sections: (None Apply)

  20. Older by-law A

    On lands municipally known as 5507 and 5509 Dundas Street West, if the requirements of By-law 55-2021 are complied with, a mixed use building and structures may be erected, used or enlarged in compliance with

  21. Older by-law B

    to (S) below; (B) Despite Regulations 40.5.40.10 (1) and (2), the height of a building or structure is the vertical distance between the Canadian Geodetic Datum elevation of 127.14 metres and the highest point of the building or structure

  22. Older by-law C

    Despite Regulation 40.5.40.60 (1) and (B) above, a canopy or, awning with or without structural support may encroach into a required minimum building setback that abuts a street

  23. Older by-law D

    Regulation 40.10.40.1(1), requiring residential uses to be located above nonresidential uses, does not apply.

  24. Older by-law E

    Despite Regulation 40.10.40.10(3), the permitted maximum height of any portion of the mixed use building , is the numerical value, in metres, following the letters "HT" as shown on Diagram 6 of By-law 55-2021.

  25. Older by-law F

    Despite Regulation 40.10.40.10(7), the permitted maximum number of storeys in any portion of the mixed use building is the numerical value followed by the letters "ST" as shown on Diagram 6 of By-law 55-2021.

  26. Older by-law G

    Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area of the mixed use building is 22,500 square metres, of which: (i) the residential gross floor area must not exceed 21,200 square metres; and (ii) the non-residential gross floor area must not exceed 1,300 square metres

  27. Older by-law H

    Non-residential gross floor area is not permitted above the first storey excluding mezzanine space.

  28. Older by-law I

    Area devoted to non-residential floor area must: (i) have a main pedestrian entrance: (a) located parallel to the lot line abutting Dundas Street West; and (b) located within 0.2 metres of the ground measured at the lot line abutting the street directly opposite the entrance; and (ii) have a minimum 6 metre finished floor to underside of interior finished ceiling height for the Dundas Street West frontage for a depth of 6 metres and a minimum of 3.6 metres for the remaining depth from the Dundas Street frontage.

  29. Older by-law J

    Dwelling units in a mixed use building are not permitted to front on the portion of the first storey facing the lot line abutting Dundas Street West.

  30. Older by-law K

    A minimum of ten percent (10 percent) of all dwelling units in the mixed use building must be three bedroom units, of which: (i) all required three bedroom units must have be a minimum of 100 square metres of interior floor area excluding mechanical space; and (ii) a minimum of fifty percent (50 percent) of the required three bedroom units must have a minimum of 106 square metres of interior floor area excluding mechanical space.

  31. Older by-law L

    A minimum of fifteen percent (15 percent) of all dwelling units in the mixed use building must be two bedroom units, of which all required two bedroom units must have a minimum of 87 square metres of interior floor area excluding mechanical space.

  32. Older by-law M

    A maximum of 265 dwelling units are permitted in the mixed use building .

  33. Older by-law N

    Any portion of the building above a height of 28.7 metres must not exceed 750 square metres, measured from exterior wall to exterior wall, excluding balconies.

  34. Older by-law O

    Despite Clause 40.10.40.70, the required minimum building setbacks are shown on Diagram 7 of By-law 55-2021

  35. Older by-law P

    Despite Regulation 40.5.40.10(4) and (E) above: (i) a mechanical penthouse is limited in accordance with the area identified as mechanical penthouse in Diagram 6 of By-law 55-2021; (ii) mechanical equipment and stair enclosures may project to a maximum of 6.0 metres above the applicable height limit and storey limit shown on Diagram 6 of By-law 55-2021; (iii) terraces and balcony guards, elements of a green roof and insulation and roof surface materials, planters, railings, parapets, and ornamental architectural features, may project to a maximum of 3.0 metres above the applicable height limit shown on Diagram 6 of By-law 55-2021; (iv) window washing equipment may project to a maximum of 8.0 metres above the applicable height limit shown on Diagram 6 of By-law 55-2021; (v) a ladder for maintenance purposes may project to a maximum of 1.2 metres above the applicable height limit shown on Diagram 6 of By-law 55-2021; and (vi) public art may project above the applicable height limit.

  36. Older by-law Q

    Despite Clause 40.10.40.70, Regulation 40.10.40.70(3) and (O) above, the following elements are permitted to encroach from the building or structure into the required building setbacks shown on Diagram 7 of By-law 55-2021; (i) eaves, cornices, columns, landscape features, wheelchair ramps, light fixtures, stairs and stair enclosures, balustrades, guardrails, bollards, awnings, arcades, canopies, raised planters, patios, retaining walls, fences, vents, screens, underground parking ramp and associated structures , damper equipment, window washing equipment to a maximum of 2.5 metres; (ii) balconies and bay windows to a maximum of 2.2 metres; (iii) structures used for outside or open air recreation, safety, noise mitigation, and wind mitigation, to a maximum of 1.6 metres; (iv) ornamental, decorative or architectural elements to a maximum of 3.1 metres; and (v) public art.

  37. Older by-law R

    Despite Regulation 200.5.10.1(1), parking spaces must be provided and maintained in accordance with the following: (i) a minimum of 0.57 parking spaces per dwelling unit must be provided for the use of the residents; (ii) a minimum of 0.1 parking spaces per dwelling unit must be provided for visitors to the residential use portion of the building ; (iii) a minimum of 0.75 parking spaces must be provided per 100 square metres of non-residential gross floor area ; (iv) Despite (R)(i) above, the minimum number of parking spaces required to be provided for the use of residents of the building may be reduced in accordance with a reduction of 4 resident parking spaces for each "car-share" parking space provided, to a maximum reduction of 12 parking spaces ; and (v) For the purposes of exception (R)(iv) above, "car-share" parking space means a parking space that is reserved and actively used for car-sharing and must be for the exclusive use of the residents of the building . "Car-share" means the practice where a number of people share the use of one or more cars that are owned by a profit or non-profit car-sharing organization and where such organization may require that use of cars to be reserved in advance, charge fees based on time and/or kilometres driven, and set membership requirements of the car-sharing organization, including the payment of a membership fee that may or may not be refundable.

  38. Older by-law S

    The lands identified with the symbol "(H)" in the zone label on Diagram 2 of By-law 55-2021 are restricted in use as specified by section 9 of By-law 55-2021. Prevailing By-laws and Prevailing Sections: (None Apply)

By-law 569-2013, Chapter 900

Lot facts

Area
1,780 m²
Frontage
30.8 m
Depth
67.7 m
Street
Dundas St W
Corner lot
No
Public lane
None
Max height
15 m
Max lot coverage
50%
  • Site and Area Specific Policy 367. The Official Plan has a policy for this site or area that varies the general rules. Read it before relying on zoning alone. Source
  • Zone (H) CR 0.6 (c0.6; r0.0) SS3 (x302) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source

Around this lot

Minor variances approved
100%1 of 1 decisions
Garden suite permits
0
Laneway suite permits
0
Multiplex permits
0
Development applications
10

Within 300 m, last 10 years. 0 suite and multiplex permits: no more than at most Toronto houses (median 3). 1 variance decisions: no more than at most Toronto houses (median 19).

Recent variance decisions in the same zone

  • Minor varianceApproved

    To alter the development standards as outlined in By-laws 55-2021 and 56-2021 to accommodate a 22-storey mixed-use building.

    5507 DUNDAS ST W · Nov 20, 2025 · 28 m away

Latest activity nearby

  • Building permit

    Application for a permit to erect and display three first party wall signs, displaying static copy and illuminated, erected at the first storey. Dimensions:Wall sign1: 1.00m L x 5.8 W x 0.105m D at a height of 4.7 on the east elevation.Wall sign2: 0.4m L x 3.1 W x 0.6m D at a height of 3.6 on the west elevation.Wall sign3: 1.5m L x 1.1 W x 0.105m D at a height of 5.0 on the north elevation.** GOOD WILL**

    5454 DUNDAS ST W · Sep 22, 2026 · 254 m away
  • Building permit

    2 wall sign and 1 overhanging structure***GOOD WILL***

    5454 DUNDAS ST W · Sep 9, 2026 · 254 m away
  • Zoning review

    Closed

    5500 DUNDAS ST W · Mar 17, 2026 · 259 m away
  • Zoning review

    Closed

    5454 DUNDAS ST W · Mar 10, 2026 · 254 m away
  • Building permit

    Alternative Solution to address the extended fire hose coverage utilizing the requirements of the 2024 ontario building code and nfpa 14.

    5509 DUNDAS ST W · Feb 6, 2026 · 20 m away
  • Development application

    Application to amend the Zoning By-law at 5500 Dundas Street West to permit two mixed-use buildings of 14 and 16 storeys (48.7 metres and 54.9 metres, excluding MPH), comprising 560 dwelling units and a minimum of 990 square metres of non-residential gross floor area at grade. A Privately Owned Publicly Accessible Space (POPS) is proposed at the south-west corner of the site.

    5500 DUNDAS ST W · Dec 19, 2025 · 276 m away · City file
  • Minor varianceApproved

    To alter the development standards as outlined in By-laws 55-2021 and 56-2021 to accommodate a 22-storey mixed-use building.

    5507 DUNDAS ST W · Nov 20, 2025 · 28 m away
  • Building permit

    Deferred Fees from folder 21 233678 (RSN-5019188) ZoningProcess RSN 69679262

    5509 DUNDAS ST W · Oct 2, 2025 · 20 m away
  • Zoning review

    Notice Sent

    37 SHORNCLIFFE RD · Sep 3, 2025 · 223 m away
  • Zoning review

    Closed

    5507 DUNDAS ST W · Jun 2, 2025 · 28 m away

Neighbourhood: Etobicoke City Centre

About the area around the lot, not the lot itself.

Nearest station
Kipling Station17 min walk
Nearest TTC stop
Shorncliffe Rd at Dundas St West South Side1 min walk
Nearest cycling route
Dundas St WCycle Track, 16 min walk
Nearest traffic count
17,848 vehicles in 8 hDundas St W / Shorncliffe Rd / Shaver Ave S, 80 m away, Nov 25, 2023
Serious collisions within 500 m
22021–2026, killed or seriously injured: 0 fatal, 1 with pedestrians, 0 with cyclists
Parks
Cloverdale Park3 min walk
Silverhill Park7 min walk
Greenfield Park12 min walk

Schools within 1 km

  • ETOBICOKE SECONDARY ALTERNATIVE SCHOOL English Public 9 min walk
  • KINGSLEY PRIMARY SCHOOL Private 15 min walk

Being near a school does not mean the lot is in its catchment; check with the board.

2021 Census

FigureEtobicoke City CentreMedian neighbourhood
Median household income (2020)$83,000$84,500
Households that own their home50%54%
Population (2021)23,60016,813
Homes built in 1960 or before9%29%
Homes needing major repairs4%7%

Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.

Police-reported crime, 2025

Per 100,000 peopleEtobicoke City CentreCity median
Assault844.4636.3
Robbery187.769.5
Shootings16.210.5
Auto theft601.8192.6
Theft over $5,000200.646.1
Break and enter210.3172.8
Theft from vehicles278.2188.1

Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.

Something here not right?

Sources

  • Building permits on this lot since 2000: Permits issued or applied for since about 2000, with status.
  • Committee of Adjustment files since 2001: Minor variances and consents (lot splits) on this lot and nearby, with decisions.
  • Development applications: Rezoning, site plan, subdivision and condominium applications.
  • Preliminary zoning reviews: Zoning reviews requested before a permit or variance application.
  • Zoning and overlays: Zoning By-law 569-2013 zone, height, coverage, policy area, parking, rooming house, priority retail street and downtown setback overlays.
  • Lot boundary, street and lane: Lot polygon, its addresses, the street it fronts, corner and public lane contact, with frontage and depth measured from the boundary; City of Toronto land in City use, which is not a home.
  • House and yards: Footprint and roof height of the house and other buildings, and the yard behind the house, from the City's 3D Massing (updated yearly, illustrative).
  • City trees in front of the lot: City-owned trees on the street allowance at this address, with species and trunk diameter. Private trees on the lot are not in open data.
  • Heritage: Heritage Register (listed and designated properties), Official Plan Amendment 720 properties and properties removed from the Register under the 2022 two-year limit.
  • TRCA regulated area: Valleys, floodplains, shorelines and wetlands regulated by the Toronto and Region Conservation Authority.
  • Ravines and natural features: Ravine and Natural Feature Protection area (Chapter 658, map last published 2019), Natural Heritage System and Environmentally Significant Areas.
  • Official Plan policies: Site and Area Specific Policies, Secondary Plans and Major Transit Station Areas covering the lot.
  • Rooming houses, short-term rentals and rental buildings: Multi-tenant house licences, short-term rental registrations and RentSafeTO evaluations at this address.
  • Neighbourhood context: Neighbourhood, 2021 Census figures, police-reported crime rates, schools, parks, TTC stops, cycling routes, serious collisions and traffic counts nearby. Area context only, not a finding about the lot.
  • Orders and by-law investigations: Outstanding Toronto Building orders, and by-law investigations open now or closed in the last two years. Fire and Public Health orders and older closed files are not published.
  • Address points: loaded Nov 22, 2026, published Nov 20, 2026
  • Toronto Building orders: loaded Nov 28, 2026, published Nov 27, 2026
  • Neighbourhood Profiles, 2021 Census: loaded Oct 14, 2026, published Oct 6, 2023
  • Street centrelines: loaded Nov 22, 2026, published Nov 20, 2026
  • City-owned land: loaded Nov 22, 2026, published Nov 16, 2026
  • Committee of Adjustment open applications: loaded Nov 28, 2026, published Nov 27, 2026
  • Committee of Adjustment decisions: loaded Nov 28, 2026, published Nov 27, 2026
  • Committee of Adjustment decisions 2001-2016: loaded Oct 14, 2026, published Feb 20, 2026
  • Collisions with people killed or seriously injured (Toronto Police Service): loaded Nov 22, 2026, published Nov 21, 2026
  • Neighbourhood crime rates (Toronto Police Service): loaded Oct 14, 2026, published Feb 20, 2026
  • Cycling network: loaded Nov 22, 2026, published Nov 16, 2026
  • Development applications: loaded Nov 28, 2026, published Nov 28, 2026
  • Environmentally Significant Areas: loaded Oct 14, 2026, published Mar 16, 2026
  • Green spaces: loaded Nov 15, 2026, published Nov 10, 2026
  • Heritage register: loaded Oct 14, 2026, published Sep 1, 2026
  • Former heritage listings: loaded Oct 14, 2026, published Jul 3, 2025
  • Official Plan Amendment 720 heritage list: loaded Oct 14, 2026, published Sep 1, 2026
  • 3D Massing building footprints: loaded Oct 14, 2026, published Dec 2, 2025
  • By-law investigation addresses: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigation deficiencies: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigations: loaded Nov 28, 2026, published Nov 27, 2026
  • Major Transit Station Areas: loaded Oct 14, 2026, published Feb 3, 2026
  • Natural Heritage System: loaded Oct 14, 2026, published Mar 16, 2026
  • Neighbourhoods: loaded Oct 14, 2026, published Feb 20, 2026
  • Property boundaries: loaded Nov 27, 2026, published Nov 27, 2026
  • Active building permits: loaded Nov 28, 2026, published Nov 27, 2026
  • Cleared building permits: loaded Nov 28, 2026, published Nov 27, 2026
  • Cleared building permits 2000-2016: loaded Oct 14, 2026, published Jul 8, 2025
  • Preliminary zoning reviews: loaded Nov 28, 2026, published Nov 27, 2026
  • Ravine and natural feature protection: loaded Oct 14, 2026, published Jul 23, 2019
  • RentSafeTO evaluations: loaded Nov 28, 2026, published Nov 27, 2026
  • Multi-tenant house licences: loaded Nov 28, 2026, published Nov 27, 2026
  • Site and Area Specific Policies: loaded Oct 14, 2026, published Mar 16, 2026
  • School locations: loaded Oct 14, 2026, published May 27, 2026
  • Secondary Plans: loaded Oct 14, 2026, published Mar 16, 2026
  • Street trees: loaded Oct 14, 2026, published Jun 4, 2026
  • Short-term rental registrations: loaded Nov 28, 2026, published Nov 27, 2026
  • Traffic counts at intersections: loaded Nov 22, 2026, published Nov 21, 2026
  • TRCA regulation limit: loaded Oct 14, 2026, published Apr 29, 2026
  • TTC stops (GTFS): loaded Nov 8, 2026, published Nov 5, 2026
  • Zoning by-law: loaded Oct 14, 2026, published Feb 20, 2026
  • Lot coverage overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Height overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Parking zone overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Policy area overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Priority retail streets: loaded Oct 14, 2026, published Feb 20, 2026
  • Rooming house overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Zoning setbacks: loaded Oct 14, 2026, published Feb 20, 2026

Contains information licensed under the Open Government Licence – Toronto. TRCA regulation limit © TRCA.

Screening tool based on City of Toronto and TRCA open data. Not a zoning review or legal opinion. Site-specific exceptions, amendments not yet in the open data, minor variances and other by-laws can change the answer. Confirm with a Preliminary Project Review or Zoning Certificate from Toronto Building before buying or designing.

Flag an error

What is not right?

The problem