Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
6 building permits open, the oldest since 2007
Needs a closer lookStill open in the City's records: 23 216110 (Electromagnetic maglocks at main door (double doors).[See separate applications, #23 18..., 2023, status Inspection); 22 208706 (Carbonix unit install and assoiated plumbing and venting.(Related MS permit: 22 208711..., 2022, status Permit Issued); 22 201222 (Proposal to install one (1) double door maglock in level 1. Please refer to Dwg. # E-01..., 2022, status Inspection); and 3 more.
What it means. An open permit can mean work that was never finished or never passed final inspection. After closing, finishing it or closing the file can fall to you.
How to confirm. Ask the seller for the final inspection records. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016)Work or applications in progress
Good to knowRecent records on this lot: 25 107282 (Alternative solution- proposed to install two sets of Speedlane Swing optical turnstile..., 2025); 14 265322 (FS - Sprinkler Shop Drawing - Construct interior alterations for Enbridge Gas at MSB St..., 2015); 09 178694 (FS - Sprinkler Shop Drawing - Interior alterations to create new board room on first floor, 2010).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications2 Committee of Adjustment files on this lot
Good to know2 approved. A0381/07NY (This is an application for variance from the provisions of the North York Zoning By-law..., 2007); A066/01U (This is an application under Section 45 of the Planning Act, for variance from the prov..., 2001).
What it means. Approved variances and consents stay with the property, including any conditions in the decision. They allow what was approved, not more.
How to confirm. Decisions are in the Application Information Centre; older files are available from the Committee of Adjustment office. Details
City of Toronto, Committee of Adjustment applications (2001 onwards)10 development applications open within 300 m
Good to know10 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 28 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
109 records on file: more than at 100% of Toronto houses (median 0).
- Building permit26 117846Closed
2 Wall Sign
Feb 25, 2026 · 500 CONSUMERS RD - Building permit26 104634Closed
Existing office to be renovated into 2 offices. HVAC scope includes; reworking radiant heating panel complete with new piping, removing existing VAV box and replacing with 2 new VAV boxes with thermostats, new ductwork for supply air, addition of a return air grille and transfer duct, and balancing the hydronic and supply air.
Jan 21, 2026 · 500 CONSUMERS RD - Zoning review25 256710 ZSVClosedNov 20, 2025 · 500 CONSUMERS RD
- Building permit25 252415Cancelled
2 WALL SIGNS**ENBRIDGE**
Nov 12, 2025 · 500 CONSUMERS RD - Building permit25 107282Under Review
Alternative solution- proposed to install two sets of Speedlane Swing optical turnstiles at the main security entrance, It is proposed to install two sets of Speedlane Swing optical turnstiles at the main security entrance, leading through Link Lobby 1418 on the Ground Floor of the Enbridge Gas office building, located at 500 Consumers Rd in Toronto, Ontario. Please refer to report dated October 24, 2024
Jan 21, 2025 · 500 CONSUMERS RD - Building permit24 221092Closed
Proposal for minor interior renovation and furniture alterations. Enbridge VPC Annex - Sustain.
Jan 8, 2025 · 500 CONSUMERS RD - Building permit24 221145Closed
Proposal to install 1 maglock on ground floor - Enbridge VPC Annex - Sustain.
Nov 4, 2024 · 500 CONSUMERS RD - Zoning review24 133505 ZAPClosedApr 7, 2024 · 500 CONSUMERS RD
Show 101 older records
- Building permit24 105240Closed
Proposal for alteration of fire sprinkler system
Feb 6, 2024 · 500 CONSUMERS RD - Building permit23 221642Closed
PROPOSED: Existing meeting room to be renovated into 2 private offices. HVAC scope includes; reworking radiant heating panel complete with new piping for room 1053A, removing existing VAV box and replacing with 2 new VAV boxes with thermostats, new ductwork for supply air, addition of a return air grille and transfer duct, and balancing the hydronic and supply air. Sprinkler heads in room 1053A repositioned for full coverage.
Nov 3, 2023 · 500 CONSUMERS RD - Building permit23 216110Inspection
Electromagnetic maglocks at main door (double doors).[See separate applications, #23 188401 BA and #23 213263 AS, for two fast lane gates]
Nov 1, 2023 · 500 CONSUMERS RD - Building permit23 180425Closed
Interior alterations - Enbridge Link Lobby renovation on the ground floor
Oct 31, 2023 · 500 CONSUMERS RD - Building permit23 213263Approved
It is proposed to install two sets of Speedlane Swing optical turnstiles at the main security entrance, leading through Link Lobby 1418 on the Ground Floor of the Enbridge Gas office building, located at 500 Consumers Rd.
Oct 11, 2023 · 500 CONSUMERS RD - Building permit23 188401Closed
Interior alterations - Renovation to Existing Executive suit area. Reconfiguration of existing historic display room to meeting room, includes addition of 2 glass doors and partitions for noise reduction. Modifications to HVAC diffusers and transfers ducts within the new meeting room. Electrical scope includes updated lighting and installation of new equipment in the new meeting room and updated lighting layout of secondary room.
Aug 21, 2023 · 500 CONSUMERS RD - Building permit23 144607Closed
Renovation to add doors to cordon off existing Executive suit area for securituy reasons, adding card reader to the new doors. Reconfiguration of 3 rooms (furniture), modification and addition of glass wall partions. Relocaton of print room, includes modification to HVAC exhaust fan to movd from exisiting location to new printer location
May 26, 2023 · 500 CONSUMERS RD - Building permit22 144588Closed
Turnstiles installation on one location. Refer to dwg #E-01of the attached drawing.
Feb 10, 2023 · 500 CONSUMERS RD - Building permit22 241748Approved
Proposed to install 2 automatic systems SmartLane 911 optical portals (i.e. automatic turnstiles) located at the west exist of 500 consumers road
Dec 22, 2022 · 500 CONSUMERS RD - Building permit22 241735Cancelled
Proposed to install 2 automatic systems SmartLane 911 optical portals (i.e. automatic turnstiles) located at the west exist of 500 consumers road
Dec 22, 2022 · 500 CONSUMERS RD - Building permit22 208711Closed
Carbonix unit install and assoiated plumbing and venting.Enbridge Distribution
Oct 20, 2022 · 500 CONSUMERS RD - Building permit22 208706Permit Issued
Carbonix unit install and assoiated plumbing and venting.(Related MS permit: 22 208711 MSA 00 MS)
Oct 20, 2022 · 500 CONSUMERS RD - Building permit22 201222Inspection
Proposal to install one (1) double door maglock in level 1. Please refer to Dwg. # E-01 of the attached drawing.
Sep 22, 2022 · 500 CONSUMERS RD - Building permit22 202968Closed
Proposed interior alterations, tenant office fit out reconfiguration.
Sep 19, 2022 · 500 CONSUMERS RD - Building permit22 145092Permit Issued
Construct interior alterations for Enbridge Toronto - fitness center and cafeteria in basement
Jun 27, 2022 · 500 CONSUMERS RD - Building permit22 159974Closed
Proposal for a tenant fit out thorough interior alterations for a corporate office on Level 3.
Jun 24, 2022 · 500 CONSUMERS RD - Building permit22 159566Closed
PHASE 2: Tenant fit out thorough interior alterations for a corporate office in basement.
Jun 23, 2022 · 500 CONSUMERS RD - Building permit22 119253Closed
Proposed installation of two (2) backflow Preventors. One to be installed in "Maintenance" building and one to be installed in "Plant" building. Drawings labelled for two different sizings and same thermal expansion tank used for both.
Mar 7, 2022 · 500 CONSUMERS RD - Building permit21 198705Cancelled
Proposal to install a new maglock on the main entrance exterior door.
Aug 16, 2021 · 500 CONSUMERS RD - Building permit21 116940Closed
HVAC - Interior alterations and reduction/addition to loading dock
May 21, 2021 · 500 CONSUMERS RD - Building permit21 133301Closed
Proposal for Decommission and Demolition of existing services and buildings. Refer to clouded areas and demolition notes within attached site plan for detailed demolition scope and extents. Proposed New equipment and serivces will be installed near the location of existing buildings (to be demolished). New Regulators will be covered via the use of x6 identical Huts. Each Hut is with size of 43" x 43" x 73" (height). Huts are openable and required to protect the control valves from weather and sun.
Apr 27, 2021 · 500 CONSUMERS RD - Building permit21 135189Closed
Proposal to demolish the existing boiler Building.
Apr 26, 2021 · 500 CONSUMERS RD - Building permit21 112903Closed
Proposal for interior alteration to an office on the 3rd floor of the existing building.
Feb 11, 2021 · 500 CONSUMERS RD - Building permit20 230627Closed
Proposal to install 1 maglock on the main entrance on ground floor of existing office building.
Feb 8, 2021 · 500 CONSUMERS RD - Building permit21 102315Closed
Interior alteration to base building
Jan 28, 2021 · 500 CONSUMERS RD - Building permit20 213984Closed
Proposal to install 1 maglock in the ground floor
Nov 10, 2020 · 500 CONSUMERS RD - Building permit20 140930Closed
Proposed interior alterations to an existing office area on the ground floor.
Sep 3, 2020 · 500 CONSUMERS RD - Building permit20 174695Inspection
replace gas boiler equipment room at south side
Aug 31, 2020 · 500 CONSUMERS RD - Building permit20 175413Closed
Proposed interior alterations of existing office space to suit revised program area
Aug 28, 2020 · 500 CONSUMERS RD - Building permit20 168331Closed
Proposed interior alterations in the annex to convert to base condition
Aug 6, 2020 · 500 CONSUMERS RD - Zoning review20 163068 ZPRClosedJul 3, 2020 · 500 CONSUMERS RD
- Building permit19 208136Closed
New interior wall enclosure for new generator room on existing mechanical and generator room
Oct 9, 2019 · 500 CONSUMERS RD - Building permit19 110309Closed
Install new sprinkler system to the second floor.
Mar 28, 2019 · 500 CONSUMERS RD - Building permit16 252949Closed
REVISON 01- INSTALL ONE PULL STATION, NEW TURNSTILES ON 4TH FLOOR PROPOSAL TO INSTALL 4 MAGLOCKS ( 3 M/L ON GROUND FL AND 1 M/L ON PENTHOUSE)
Feb 25, 2019 · 500 CONSUMERS RD - Building permit18 254633Closed
PROPOSAL TO INSTALL 1 MAGLOCK ON 2nd FLOOR
Dec 12, 2018 · 500 CONSUMERS RD - Building permit18 250372Closed
Proposal to install one maglock on ground floor of existing office building.
Nov 27, 2018 · 500 CONSUMERS RD - Building permit18 245420Refused
Proposed alternative solutions for atuomatic turnstiles.
Oct 19, 2018 · 500 CONSUMERS RD - Building permit17 231407Closed
Addition of a how water heating pump and modifications to the hot water piping configuration
Sep 20, 2017 · 500 CONSUMERS RD - Building permit16 225450Closed
Interior demolition of existing tenant space. Interior alteration of entire 2nd floor space for client, Enbridge Gas Distribution Inc.
Nov 3, 2016 · 500 CONSUMERS RD - Building permit16 181157Closed
Proposal to install a certified tent 14-240266 (40 x 100) to be erected July 18 and dismantled July 19th for Enbridge Gas employee event.
Jul 19, 2016 · 500 CONSUMERS RD - Building permit16 146104Closed
Interior alterations, penthouse addition on the roof and enclosing the north rear loading dock
Jun 24, 2016 · 500 CONSUMERS RD - Building permit16 152206Closed
Install Certified tent 40'x60' frame tent
May 26, 2016 · 500 CONSUMERS RD - Building permit16 134819Closed
Demolition on interior improvements to base building condition.
Apr 8, 2016 · 500 CONSUMERS RD - Building permit16 120130Closed
Proposal to install 1 mag lock on the 4th floor of the existing office building.
Feb 26, 2016 · 500 CONSUMERS RD - Building permit15 263360Closed
Proposal for interior alterations to the 4th floor in existing office - tenant is "Enbridge"
Jan 22, 2016 · 500 CONSUMERS RD - Building permit15 256676Closed
install 1 maglock on 3rd floor
Dec 1, 2015 · 500 CONSUMERS RD - Building permit15 250543Closed
New fire protection sprinkler system for existing building on the 3rd floor see 15 - 202577
Nov 25, 2015 · 500 CONSUMERS RD - Building permit15 202577Closed
Removal of existing office space, and reworking floor based on corporate workstation/office standards. All electrical and mechanical systems will be updated and sprinklers will be added.
Sep 10, 2015 · 500 CONSUMERS RD - Building permit15 195652Closed
Proposal to install 1 maglock on 5th floor.
Aug 4, 2015 · 500 CONSUMERS RD - Building permit15 157088Closed
Install proposed 40 x 60 certified tent (cert #14-240264) in parking lot from June 4, 2015 and removed June 4th 2015.
May 21, 2015 · 500 CONSUMERS RD - Building permit14 262043Closed
To construct interior alterations (3437m2) of work for Enbridge Gas
Feb 13, 2015 · 500 CONSUMERS RD - Building permit14 265322Application On Hold
FS - Sprinkler Shop Drawing - Construct interior alterations for Enbridge Gas at MSB Storage buidling
Feb 6, 2015 · 500 CONSUMERS RD - Building permit15 102348Closed
Fire Alarm control equipment replacement-office building.
Feb 2, 2015 · 500 CONSUMERS RD - Building permit14 224358Closed
Create new opening with barrier free ramp
Oct 8, 2014 · 500 CONSUMERS RD - Building permit14 155395Closed
Install proposed 40 x 60 certified tent (cert #10-256161) in parking lot from June 4, 2014 and removed June 4th 2014.
May 29, 2014 · 500 CONSUMERS RD - Building permit13 259888Cancelled
Interior alteration for enbridge office space
Dec 4, 2013 · 500 CONSUMERS RD - Building permit13 221238Closed
CERTIFIED TEMPORARY TENT, 1 _ 30ft x 45 ARCHTOP FRAME TENT (Cert # 11 167176) August 22nd to 23rd, 2013
Aug 21, 2013 · 500 CONSUMERS RD - Building permit13 175890Closed
Enbridge Gas (Certified Tent # 11 -167121 ) 40 ft x 60 archtop frame tent May 29th to 30th. 2013
May 30, 2013 · 500 CONSUMERS RD - Building permit12 286036Closed
One electromagnetic maglock on the ground floor - Enbridge Gas Distribution Inc
Dec 21, 2012 · 500 CONSUMERS RD - Building permit12 290213Closed
To erect and display two static copy illuminated wall signs at the southerly elevation of the building in conjunction with an exiting public utilities business office operating on the premises. **Enbridge**
Dec 18, 2012 · 500 CONSUMERS RD - Building permit12 244533Closed
Installation of one electromagnetic maglock on the ground floor - Enbridge Gas Distribution Inc
Oct 10, 2012 · 500 CONSUMERS RD - Building permit12 244526Closed
Alterations to offices on the ground floor - Enbridge Gas Distribution Inc
Oct 10, 2012 · 500 CONSUMERS RD - Building permit12 145633Cancelled
Enbridge - 5th Floor - Int. Alt.
Apr 13, 2012 · 500 CONSUMERS RD - Building permit11 268704Closed
Enbridge Gas Certified Tents ( Cret # 11 -167121 ) 50 ft x 110 ft pole tent no walls Sept 15th to 17th.
Sep 7, 2011 · 500 CONSUMERS RD - Building permit11 256129Closed
Installation of one certified tent for a corporate event for Enbridge Gas - August 17 to 18, 2011.
Aug 18, 2011 · 500 CONSUMERS RD - Building permit09 178694Application On Hold
FS - Sprinkler Shop Drawing - Interior alterations to create new board room on first floor.
Feb 9, 2010 · 500 CONSUMERS RD - Building permit08 229341Cancelled
Building 2, dock 1 - Loading dock and receiving area - Enbridge Gas Distribution
Apr 20, 2009 · 500 CONSUMERS RD - Building permit08 141146Closed - Dormant
Construction of a concrete structural slab to support the installation of new outdoor certified equipment (fuel cell) a cogeneration system.
Apr 16, 2008 · 500 CONSUMERS RD - Building permit08 103426Closed - Dormant
Alterations and upgrades to existing office and industrial facilities in Building #2 for Enbridge Gas Distribution Inc
Apr 14, 2008 · 500 CONSUMERS RD - Zoning review08 121308 PSPClosedMar 25, 2008 · 500 CONSUMERS RD
- Development application08 120083 NNY 33 SAClosed
The owners are pursuing the construction of a fuel cell system as part of a co-generation facility. This fuel cell will be integrated with the natural gas pipeline on the site. The uses on the site include: general office, general warehouse and mechanical services. The site currently has 6 structures as follows: a mechanical services building (area of 3 325 m²); a single storey industrial/warehouse building (area of 8 145 m²); and a five storey office building (area of 3 603 m²). There are also existing mechanical buildings lcoated at the north-east corner of the property which include: an electrical substation (area of 58.1 m²); a turbo expander and related structures (area of 89.7 m²); and heating plant/regulator building (area of 48.4 m²). A large surface parking lot is located to the rear of the office, mechanical services and industrial/warehouse buildings.
Mar 18, 2008 · 500 CONSUMERS RD - Minor varianceA0381/07NYApproved
This is an application for variance from the provisions of the North York Zoning By-law 7625, as amended, to maintain the pre-engineered regulator building which was constructed beyond Committee of Adjustment decision number A066/01U, which granted a rear yard setback for this building of 2.4 m.
Aug 29, 2007 · 500 CONSUMERS RD - Zoning review07 233629 ZPRClosedJun 18, 2007 · 500 CONSUMERS RD
- Building permit06 199438Permit Issued
Construction of a Substation Building B
Feb 22, 2007 · 500 CONSUMERS RD - Building permit06 141113Closed
Int Alt for wxpanded employee only gym with new shower and locker facilites on basement floor.
Jul 5, 2006 · 500 CONSUMERS RD - Building permit02 121312Closed
EXTERNAL SECURITY STATION
May 29, 2002 · 500 CONSUMERS RD - Building permit02 125940Closed - Dormant
TO INSTALL 2 ELECTROMAGNETIC LOCKS ON THE GROUND FLOOR.
Apr 26, 2002 · 500 CONSUMERS RD - Building permit02 121316Closed
CONSTRUCT AN EXTERNAL PHONE ACCESS IN THE ONE STOREY LINK BETWEEN THE OFFICE BUILDINGS.
Apr 10, 2002 · 500 CONSUMERS RD - Building permit01 142432Closed
ENCLOSE EXISITING REGULATOR STATION (NEW ACCESSORY STRUCTURES) IN THE REAR OF AN EXISITING OFFICE BUILDING SITE.
Nov 9, 2001 · 500 CONSUMERS RD - Minor varianceA066/01UApproved
This is an application under Section 45 of the Planning Act, for variance from the provisions of the North York Zoning By-law 7625, as amended, to permit the construction of two preengineered buildings to cover the existing valves and equipment used to regulate the flow of natural gas. Building 1 would have dimensions of 3m x 4.2m while Building 2 would have dimensions of 6m x 6m.
Sep 13, 2001 · 500 CONSUMERS RD - Building permit01 122096Closed
INTERIOR ALTERATIONS TO AN EXISTING WASHROOM IN THE BASEMENT
Apr 17, 2001 · 500 CONSUMERS RD - Building permit01 122117Closed
INTERIOR ALTERATIONS TO AN EXISTING WASHROOM IN THE BASEMENT
Apr 4, 2001 · 500 CONSUMERS RD - Building permit01 122114Closed
INTERIOR ALTERATIONS TO AN EXISTING WASHROOM IN THE BASEMENT, 20 FIXTURES AND SANITARY DRAIN ADDITION.
Apr 2, 2001 · 500 CONSUMERS RD - Building permit01 116535Closed
INSTALL ONE NEW ELECTROMAGETIC LOCKS
Mar 28, 2001 · 500 CONSUMERS RD - Building permit00 361882Closed
INSTALLING THREE MAGLOCKS ON THE GROUND FLOOR
Dec 28, 2000 · 500 CONSUMERS RD - Building permit00 359237Closed
INTERIOR ALTERATIONS ON THE 5TH FLOOR
Dec 18, 2000 · 500 CONSUMERS RD - Building permit00 359231Closed
INTERIOR ALTERATIONS ON THE SECOND FLOOR, 22 FIXTURES
Dec 15, 2000 · 500 CONSUMERS RD - Building permit00 359206Closed
INTERIOR ALTERATIONS TO THE COMMON WASHROOMS ON THE 5TH FLOOR.
Dec 12, 2000 · 500 CONSUMERS RD - Building permit00 348781Closed
INSTALLING TWO MAGLOCKS ON THE GROUND FLOOR
Oct 30, 2000 · 500 CONSUMERS RD - Building permit00 176724Closed
INTERIOR ALTERATION TO WASHROOM OF AN EXISTING OFFICE BUILDING.
Aug 11, 2000 · 500 CONSUMERS RD - Building permit00 141330Closed
REVISION TO ORIGINAL PERMIT - HVAC FOR AN INTERIOR ALTERATION TO AN EXISITNG BUILDING
Aug 10, 2000 · 500 CONSUMERS RD - Building permit00 176736Closed
HVAC FOR AN INTERIOR ALTERATION TO WASHROOM OF AN EXISTING OFFICE BUILDING.3RD FLOOR
Aug 3, 2000 · 500 CONSUMERS RD - Building permit00 143302Closed
INTERIOR ALTERATIONS TO EXISTING WASHROOMS ORIG. NO 143302
Jun 15, 2000 · 500 CONSUMERS RD - Building permit00 141325Closed
INTERIOR ALTERATION TO AN EXISITNG BUILDING
May 31, 2000 · 500 CONSUMERS RD - Building permit00 143319Closed
INTERIOR ALTERATION TO EXISTING WASHROOMS ORIG. NO 143302
May 30, 2000 · 500 CONSUMERS RD - Building permit99 104899Closed
Note fees paid under file 104303, for all permits building, plumbing and HVAC pre made cheque for 450.00.
Apr 6, 2000 · 500 CONSUMERS RD - Building permit00 129982Closed
HVAC FOR AN INTERIOR OFFICE RENOVATION TO THE 1 ST FLOOR ORIG PERMIT 00-129980
Feb 29, 2000 · 500 CONSUMERS RD - Building permit98 251033Closed - Dormant
SPRINKLERS RELOCATION
Feb 15, 1999 · 500 CONSUMERS RD - Building permit98 251135Closed - Dormant
FIRE RETROFIT
Jul 14, 1998 · 500 CONSUMERS RD - Building permit96 089956Closed
ADD SPRINKLER SYSTEM
Mar 21, 1997 · 500 CONSUMERS RD - Building permit96 089934Closed
INT ALT ''CONSUMERS GAS''
Dec 13, 1996 · 500 CONSUMERS RD
Check before you build
Zoning not in By-law 569-2013
Needs a closer lookThis lot is not covered by the citywide zoning by-law's map. It is probably still governed by a former municipal by-law, which this tool does not read yet.
Zoning By-law 569-2013
Lot facts
- Area
- 60,760 m²
- Frontage
- 185.9 mestimated, irregular lot
- Depth
- 389.8 mestimated, irregular lot
- Street
- Esther Cutler Rd
- Corner lot
- Yes, also on Consumers Rd389.8 m along it
- Public lane
- None
- House footprint
- 12,105 m²roof up to 41.4 m
- Back yard
- 143 mhouse to rear lot line
- Side yards
- 55.6 m and 58.2 mhouse to side lot lines
- Buildings on the lot
- 2house, garage, sheds
- Max height
- —
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
- 14 City trees in front of this lot. The City's street tree inventory lists 14 trees at this address: pine, austrian (37 cm), pine, austrian (35 cm), pine, austrian (32 cm). Diameter is the trunk at breast height. Source
Around this lot
- Minor variances approved
- 100%3 of 3 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 0
- Development applications
- 13
Within 300 m, last 10 years. 0 suite and multiplex permits: no more than at most Toronto houses (median 3). 3 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To facilitate in the redevelopment of the subject property and increase the podium height of Tower "A", reduce the required number accessible parking spaces and remove Section 37 clauses that regulate development phasing. Other Planning applications include: 19147759NNY17OZ, 20232552NNY17SB, 22140264NNY17SA. Please note, this application was previously deferred September 11, 2025.
2550 VICTORIA PARK AVE · Jan 8, 2026 · 206 m away - Minor varianceApproved
To permit a Commercial School, within the existing 7-storey office building.
2450 VICTORIA PARK AVE · May 1, 2025 · 211 m away - Minor varianceApproved
To permit the reduction of gross floor area devoted to office, medical office, or software development and processing on Block 4. Cross-reference Zoning By-law Amendment Application 19 147759 NNY 17 OZ, Draft Plan of Subdivision Application 20 232552 NNY 17 SB and Site Plan Control Application 22 140264 NNY 17 SA.
2550 VICTORIA PARK AVE · Oct 24, 2024 · 206 m away - Minor varianceApproved
Proposal to allow a Medical Clinic as a permitted use.
280 CONSUMERS RD · Sep 12, 2024 · 436 m away - Minor varianceApproved
Legal non-conforming condition(s) to be brought into conformity with By-law to support an application for conversion of existing buildings to a standard condominium. No development is contemplated. Related file is 2022 210795 NNY CD.
280 CONSUMERS RD · Jan 18, 2024 · 436 m away
Latest activity nearby
- Building permit
INSTALLATION OF TWELVE (12) ELECTROMAGNETIC LOCKS N THE 2ND, 3RD, AND 4TH FLOOR ELEVATOR LOBBIES
2235 SHEPPARD AVE E · Oct 22, 2026 · 286 m away - Zoning review
Closed
2555 VICTORIA PARK AVE · Sep 15, 2026 · 275 m away - Zoning review
Closed
2 LANSING SQ · Sep 11, 2026 · 267 m away - Building permit
Proposal for plumbing permit
515 CONSUMERS RD · Sep 11, 2026 · 120 m away - Zoning review
Closed
515 CONSUMERS RD · Sep 4, 2026 · 120 m away - Building permit
Interior alterations to renovate office for new tenant
2235 SHEPPARD AVE E · Sep 4, 2026 · 286 m away - Building permit
Tenant fit-out convert existing restaurant into commercial bakery.
515 CONSUMERS RD · Aug 31, 2026 · 120 m away - Building permit
PROPOSED INTERIOR RENOVATION (COMMERCIAL)
2555 VICTORIA PARK AVE · Aug 18, 2026 · 275 m away - Building permit
2 Wall Sign*****RELIANCE*****
2235 SHEPPARD AVE E · Jul 21, 2026 · 286 m away - Building permit
Installation of temporary tents - 60'x80' (CERT#25 136452 000 00) , 40'x75' (CERT#25 137538 000 00) , 10'x20' (CERT#25 135788 000 00), 20'x20' and 20'x30' (CERT#25 135795 000 00). All tents staked into the ground, for the Armenian Community Centre's summer festival event July 10-12, 2026. Installation: July 6-8, 2026, Removal: July 13, 2026
50 HALLCROWN PL · Jul 9, 2026 · 294 m away
Neighbourhood: Henry Farm
About the area around the lot, not the lot itself.
- Nearest station
- Don Mills Station29 min walk
- Nearest TTC stop
- Consumers Rd at Hallcrown Pl2 min walk
- Nearest cycling route
- Huntingwood DrCycle Track, 15 min walk
- Nearest traffic count
- 14,295 vehicles in 14 hConsumers Rd / Hallcrown Pl, 110 m away, Jan 22, 2026
- Serious collisions within 500 m
- 12021–2026, killed or seriously injured: 0 fatal, 1 with pedestrians, 0 with cyclists
- Parks
- Farmcrest Parkette5 min walk
- Hickorynut Parkette5 min walk
- Atria South Park6 min walk
Schools within 1 km
- A R S ARMENIAN PRIVATE SCHOOL Private 4 min walk
- VICTORIA PARK LINC CENTRE English Separate 4 min walk
- HANSON COLLEGE Private 10 min walk
- AMBERWOOD ACADEMY Private 10 min walk
- ELITE ACADEMIC SECONDARY SCHOOL Private 10 min walk
- OXFORD COLLEGE OF CANADA SECONDARY SCHOOL Private 11 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Henry Farm | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $79,500 | $84,500 |
| Households that own their home | 39% | 54% |
| Population (2021) | 19,840 | 16,813 |
| Homes built in 1960 or before | 5% | 29% |
| Homes needing major repairs | 4% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Henry Farm | City median |
|---|---|---|
| Assault | 286.8 | 636.3 |
| Robbery | 51.1 | 69.5 |
| Homicide | 3.9 | 5.3 |
| Shootings | 3.9 | 10.5 |
| Auto theft | 192.5 | 192.6 |
| Theft over $5,000 | 27.5 | 46.1 |
| Break and enter | 55 | 172.8 |
| Theft from vehicles | 94.3 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.