HousePrecheckCheck an address

45 Collegiate RdToronto · zoning, lot size and permit records

Also 24 Assembly Lane, 32 Assembly Lane, 55 Collegiate Rd, 65 Collegiate Rd

Commercial residential · CR 3.0 (c1.0; r2.0) SS2 (x373)≈ 98.8 × 155.6 m7,517 m²on Bloor St Wcorner, also on Collegiate Rd

Not a home

A commercial or mixed-use building

5 different civic addresses share this parcel, in a commercial zone: shops, offices or a mixed-use building rather than one house. It is not a home for sale, so the house checks and the pre-offer report do not apply.

Looking at a house nearby? What this means for you

  • Shops, offices or a mixed buildingCustomers, deliveries and evening activity; errands within a short walk.
  • Permits or applications open on this parcelRecent records on this lot: 26 122265 STE 09 SA (Site Plan Administrative Amendment to 22 129524 STE 09 SA, 2026); 26 122305 STE 09 SA (Site Plan Administrative Amendment to 22 129491 STE 09 SA, 2026); 22 140172 STE 09 SA (Site Plan Approval for a 33-storey mixed-use building having a non-residential gross fl..., 2022); and 4 more. Larger work can mean noise and trucks next door; read what each one is for.
  • 8 development applications open within 300 m, up to 37 storeysNew buildings may go up around here in the next years. More change nearby than at 98% of Toronto houses.
  • 1 open order or by-law investigation at this buildingThe City is following up on complaints here, such as upkeep, heat or noise. Not resolved in the City's records: 25 195151 WNP 00 VI (Order Issued No Permit: Site Progress- Block C, 2025, status Stop Work Order Issued).
  • Major Transit Station Area: DufferinThe City plans more homes around the station: good for transit, and more building over time.
N50 m
≈ 98.8 m frontage≈ 155.6 m deepirregular lot, estimated

Before you offer

From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.

  • 1 open order or by-law investigation

    Needs a closer look

    Not resolved in the City's records: 25 195151 WNP 00 VI (Order Issued No Permit: Site Progress- Block C, 2025, status Stop Work Order Issued).

    What it means. An order is attached to the property, not to the seller. If it is not resolved before closing, the work, permits or fines it calls for can fall to you.

    How to confirm. Ask the seller how each order will be resolved and get it in writing. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details

    City of Toronto, Toronto Building orders and Municipal Licensing and Standards investigations
  • Work or applications in progress

    Good to know

    Recent records on this lot: 26 122265 STE 09 SA (Site Plan Administrative Amendment to 22 129524 STE 09 SA, 2026); 26 122305 STE 09 SA (Site Plan Administrative Amendment to 22 129491 STE 09 SA, 2026); 22 140172 STE 09 SA (Site Plan Approval for a 33-storey mixed-use building having a non-residential gross fl..., 2022); and 4 more.

    What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.

    How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details

    City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications
  • 8 development applications open within 300 m

    Good to know

    8 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 37 storeys. They are listed under Around this lot.

    What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.

    How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details

    City of Toronto, Development Applications

Not in these records

  • Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
  • Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.

History of this lot

13 records on file: more than at 100% of Toronto houses (median 0).

  • Development application26 122265 STE 09 SAUnder Review

    Site Plan Administrative Amendment to 22 129524 STE 09 SA.

    Feb 27, 2026 · 1141 BLOOR ST W
  • Development application26 122305 STE 09 SAUnder Review

    Site Plan Administrative Amendment to 22 129491 STE 09 SA.

    Feb 27, 2026 · 1141 BLOOR ST W
  • Building order25 195151 WNP 00 VIStop Work Order Issued

    Order Issued No Permit: Site Progress- Block C

    Jul 16, 2025 · 1141 BLOOR ST W
  • Development application23 226738 STE 09 OZClosed

    Proposal to amend Site and Area Specific Policy 581 ("SASP 581") in the City of Toronto Official Plan, as amended by Official Plan Amendment 489 ("OPA 489"), to reduce the minimum gross floor area for community hub space to be provided as part of the approved mixed-use development. The requested amendment is technical in nature and is reflective of recent updated information with respect to the calculation of the existing floor area that determined the minimum size of the community hub.

    Nov 16, 2023 · 1141 BLOOR ST W · City file
  • Development application22 140164 STE 09 SAClosed

    Site Plan Approval for an 8-storey residential building having a gross floor area of 2643.5 square metres, and containing 56 affordable dwelling units.

    Apr 29, 2022 · 1141 BLOOR ST W · City file
  • Development application22 140160 STE 09 SAFinal Approval Completed

    Site Plan Approval for a 22-storey mixed-use building having a non-residential gross floor area of 981.5 square metres, and a residential gross floor area of 24,500.30 square metres. 264 rental dwelling units are proposed.

    Apr 29, 2022 · 1141 BLOOR ST W · City file
  • Development application22 140172 STE 09 SANOAC Issued

    Site Plan Approval for a 33-storey mixed-use building having a non-residential gross floor area of 3347.40 square metres, and a residential gross floor area of 31,223.90 square metres. 415 rental dwelling units are proposed.

    Apr 29, 2022 · 1141 BLOOR ST W · City file
  • Development application22 140155 STE 09 SAClosed

    Site Plan Approval for a 19-storey mixed-use building having a non-residential gross floor area of 7566.2 square metres, and a residential gross floor area of 22,475.9 square metres. 228 rental dwelling units are proposed.

    Apr 29, 2022 · 1141 BLOOR ST W · City file
Show 5 older records
  • Development application22 129524 STE 09 SANOAC Issued

    Site Plan Approval for a 37-storey mixed-use building having a non-residential gross floor area of 1543.20 square metres, and a residential gross floor area of 57,746.0 square metres. 844 rental dwelling units are proposed.

    Apr 1, 2022 · 1141 BLOOR ST W · City file
  • Development application22 129491 STE 09 SANOAC Issued

    Site Plan Approval for an 11-storey mixed-use building having a non-residential gross floor area of 5755.70 square metres, and a residential gross floor area of 15,948.80 square metres. 211 residential dwelling units are proposed.

    Apr 1, 2022 · 1141 BLOOR ST W · City file
  • Development application18 149098 STE 18 SAUnder Review

    INACTIVE To facilitate a mixed-use redevelopment of the site:149,055 square metres of res. GFA (2018 dwelling units); 15,656 square metres of retail/commercial uses; 2,887 square metres of office uses; 2,868 square metres of existing floor area within the Kent Senior Public School.

    Apr 26, 2018 · 1141 BLOOR ST W · City file
  • Development application17 237276 STE 18 SBUnder Review

    Draft Plan of Subdivision (10 lots) to facilitate a mixed-use redevelopment of the site: 147,512 square metres of res. GFA (2,219 dwelling units); 15,780 square metres of retail/commercial uses; 4,900 square metres of office uses; 2,815 square metres of existing floor area within the Kent Senior Public School, which will be renovated as a community hub.

    Sep 22, 2017 · 1141 BLOOR ST W · City file
  • Development application17 237256 STE 18 OZClosed

    Official Plan & Zoning By-law Amendments to facilitate a mixed-use redevelopment of the site:149,055 square metres of res. GFA ; 15,656 square metres of retail/commercial uses; 2,887 square metres of office uses; 2,868 square metres of existing floor area within the Kent Senior Public School.

    Sep 22, 2017 · 1141 BLOOR ST W · City file

Check before you build

  • Site-specific exception 900.11.10(373)

    Needs a closer look

    26 site-specific rules apply to this lot. They can override the standard rules on this page.

    Zoning By-law 569-2013, Chapter 900
Exception 900.11.10(373)Applies

These parts of the exception apply to this lot's address.

  1. Rule B

    to (GG) below, are complied with, an apartment building on Block F and mixed-use buildings may be constructed and used; (B) For the purposes of By-law 700-2021(OLT), reference to Block A, Block B, Block C, Block D, Block, E, Block F, and the public park are as identified on Diagram 6 attached to By-law 700-2021(OLT) and reference to building A, building B1, building B2, building C, building D, building E and building F are the buildings within such Blocks as identified on Diagrams 7 and 8 attached to By-law 700-2021(OLT)

  2. Rule C

    Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area on the lands must not exceed 167,230 square metres, and provided that: (i) the residential gross floor area must not exceed 145,807 square metres up to the maximum permitted for each Block: (a) 15,950 square metres for Block A; (b) 57,800 square metres for Block B; (c) 27,900 square metre for Block C; (d) 20,700 square metres for Block D; (e) 20,700 square metres for Block E; and (f) 2,900 square metres for Block F; (ii) the combined maximum non-residential gross floor area across all Blocks must not exceed 22,000 square metres, subject to: (a) the provision of a community centre located on Block D having a minimum of gross floor area of 2,787 square metres and containing a day nursery with a minimum gross floor area of 743 square metres; and (b) the community centre may include a club ; (iii) despite Provision (C)(ii) above and (H) below, up to a maximum of 10 buildings or structures may be erected within the "Private Street" as shown on Diagram 6 attached to By-law 700-2021(OLT), subject to the following: (a) each building or structure may have a maximum non-residential gross floor area of 10 square metres; (b) each building or structure has a maximum height of no greater than 3 metres; and (c) any such building or structures are only permitted when the "Private Street" is closed to vehicle access as set out in Schedule A

  3. Rule D

    Despite Regulation 40.10.40.10(2), the permitted maximum height for each building or structure is the numerical value measured in metres following the HT symbol on Diagrams 7 and 8 attached to By-law 700-2021(OLT)

  4. Rule E

    The permitted maximum number of storeys for each building is the numerical value following the ST symbol on Diagrams 7 and 8 attached to By-law 700-2021(OLT)

  5. Rule F

    For the purpose of this exception, the following are not a storey : (i) a mechanical penthouse or mezzanine level of any building on the Blocks, except building A as shown Diagram 7 attached to By-law 700-2021(OLT)

  6. Rule G

    Despite Regulations 40.5.40.10(1) and (2), the height of a building or structure is the vertical distance between the elevation of the highest point of the building or structure and the Canadian Geodetic Datum elevation of: (i) 112.00 metres, inclusive of a mechanical penthouse and amenity space for building A; (ii) 111.20 metres for building B1; (iii) 111.20 metres for building B2; (iv) 112.70 metres for building C; (v) 112.00 metres for building D; (vi) 111.00 metres for building E; and (vii) 111.00 metres for building F

  7. Rule H

    Despite Regulations 5.10.40.70(1), (2), (3) and (4), clauses 40.5.40.60 and 40.10.40.60, and Regulations 40.10.40.70(2) and 40.10.40.80(2), the required minimum building setbacks and required minimum above-ground distance between the main walls is as shown in metres on Diagrams 7 and 8 attached to By-law 700-2021(OLT)

  8. Rule I

    Despite Regulation 40.5.40.10(4), landscaping may also exceed the permitted maximum height for the building by a maximum of 5.0 metres, subject to Regulation 40.5.40.10(5)

  9. Rule J

    Despite Regulation 40.5.40.10(5), equipment, structures or parts of a building exceeding the permitted maximum height for a building , as permitted by Regulation 40.5.40.10(4), must comply with the following (i) the total area of all equipment, structures , or parts of a building may cover 100 percent of the area of a roof, measured horizontally; (ii) any equipment, structures , parts of a building , planters and landscaping may be located within 6.0 metres of a lot line abutting a street , regardless of their total horizontal dimension; and (iii) Provisions (J)(i) and (ii) above do not permit additional gross floor area beyond that permitted in Provision (C) above

  10. Rule K

    Despite Regulation 40.5.40.10(6), unenclosed structures providing safety or wind protection to rooftop amenity space may exceed the permitted maximum height for that building by 3.0 metres, if the structures are no closer than 0.0 metres from the interior face of any main wall

  11. Rule L

    Despite Regulations 40.5.40.10 (4), (5), (8)(A) and (C), the area of equipment, structures or parts of a building , as permitted by Regulation 40.5.40.10(4), listed in the regulation located on the roof of a permitted building may exceed the permitted maximum height for that building by 6.5 metres and may cover up to 100 percent of the area of the storey immediately below the subject roof

  12. Rule M

    Despite Regulation 40.5.40.10(8)(A), lightning rods, window washing equipment may exceed the permitted heights shown on Diagrams 7 and 8 attached to By-law 700-2021(OLT) equal to the sum of the height following the letters HT and up to a maximum 5.0 metres

  13. Rule N

    Despite Regulation 40.5.40.10(8)(B), chimneys, pipes, vents, and air handling unit may exceed the permitted shown on Diagrams 7 and 8 attached to By-law 700-2021(OLT) equal to the sum of the height following the letter HT and up to a maximum of 3.0 metres

  14. Rule O

    Despite Regulations 5.10.40.70(1), (2), (3) and (4), clauses 40.5.40.60 and 40.10.40.60, and regulations 40.10.40.70(2) and 40.10.40.80(2), the required minimum building setbacks and required minimum above-ground distance between the main walls are as shown in metres on Diagrams 7 and 8 attached to By-law 700-2021(OLT), except that: (i) cornices, pilasters, parapets, other ornamental elements, eaves, window sills, light fixtures and any related access structures or drainage for the foregoing, which may encroach beyond the distance between main walls shown on Diagrams 7 and 8, by up to a maximum of 1.0 metre for buildings fronting the Private Street; (ii) guardrails, fences, screens, decks, balconies, terraces and landscape features as well as any related access, balustrades, railings, infrastructure, covers and associated structures and drainage for the foregoing, which may encroach into the building setbacks and distance between main walls shown on Diagrams 7 and 8, by up to maximum of 2.5 metres; (iii) despite Provision (O)(ii) above, guardrails, fences, screens, decks, balconies, terraces and landscape features as well as any related access, balustrades, railings, infrastructure, covers and associated structures and drainage located on building B2 may only encroach beyond the building setbacks and distance between main walls shown on Diagrams 7 and 8, by up to a maximum of 2.5 metres only for the portion of the building above the second storey to the top of the eighth storey fronting the Private Street; (iv) access stairs and enclosures, wheelchair ramps, window washing equipment, building maintenance units, site servicing features, ventilation shafts and any related access, guardrails, balustrades, railings, infrastructure, covers or drainage for the foregoing may encroach into and beyond the building setbacks and distance between main walls shown on Diagrams 7 and 8, by up to a maximum of 5.0 metres; (v) Provisions (O)(i) to (iv) above does not apply to the area identified as heritage building to be retained on building D, except for amenity space or an outdoor eating establishment and ancillary structures to the eating establishment use permitted by the City; and (vi) Provisions (O)(i) to (iv) above does not permit encroachments, projections or otherwise beyond the building setbacks adjacent to a street

  15. Rule P

    Regulation 40.5.40.10(5), 40.5.40.10(6), 40.5.40.10(8)(A) and (C) and Provisions (J), (K), and (L) above do not apply to building A

  16. Rule Q

    Despite Regulation 40.10.40.60(1)(C) and Provision (H) above, a platform with no roof may encroach into the lands identified as "Private Street" on Diagram 6 attached to By-law 700-2021(OLT) up to a maximum of 1.5 metres

  17. Rule R

    Despite regulation 40.10.40.50(1), amenity space must be provided at a minimum rate of 2.8 square metres for each dwelling unit of which: (i) at least 1.5 square metres for each dwelling unit is indoor amenity space ; (ii) at least 40.0 square metres is outdoor amenity space in a location adjoining or directly accessible to the indoor amenity space ; (iii) no more than 25 percent of the outdoor component may be a green roof ; and (iv) zero (0) square metres of amenity space is required for the dwelling units on Block F as shown on Diagram 6 attached to By-law 700-2021(OLT)

  18. Rule S

    The maximum number of dwelling units located on Blocks A, B, C, D, and E is 2,106 and must be provided in accordance with the following: (i) 211 dwelling units on Block A; (ii) 859 dwelling units on Block B; (iii) 421 dwelling units on Block C; (iv) 315 dwelling units on Block D; and (v) 300 dwelling units on Block E

  19. Rule T

    The provision of dwelling units located on Blocks A, B, C, D, and E is subject to the following: (i) a minimum of 11 percent of the total number of dwelling units across the blocks must contain three or more bedrooms; and (ii) a minimum of 20 percent of the total number of dwelling units across the blocks must contain two bedrooms

  20. Rule U

    Despite Regulation 40.10.20.100 (20) the outdoor sale or display of goods or commodities: (i) does not need to be combined with another permitted non-residential use; (ii) there is no maximum cumulative area for the outdoor sale or display of goods and commodities; and (iii) storage or warehousing of goods may be permitted in a vehicle

  21. Rule V

    Despite Regulation 40.10.100.10(1)(C), more than one vehicle access is permitted on the lands, and 40.10.100.10(1)(B) does not apply

  22. Rule W

    Despite Regulations 200.5.10.1(1) and Table 200.5.10.1, parking spaces must be provided in accordance with the following: (i) a minimum of 0.29 parking spaces per dwelling unit for residents; (ii) a minimum of 0.06 parking spaces per dwelling unit for residential visitors; (iii) a minimum of 1.0 parking spaces per 100 square metres of gross floor area for non-residential uses; (iv) despite Provision (W)(iii) above, zero (0) parking spaces are required for eating establishments , take-out eating establishments ; (v) despite Provision (W)(iii) above, above and 200.5.1.10(2)(A)(ii); (a) a minimum of 4 of the required parking spaces must be for the exclusive use of the community centre and day nursery use and may be shared; and (b) the parking spaces under (a) above must have a minimum width of 3.9 metres. (vi) a reduction of four (4) resident parking spaces may be provided for each car-share parking space provided, to a maximum of 15 car-share parking spaces; and (vii) Despite Provisions (W)(i) and (ii) above, zero (0) parking spaces are required for building F as shown on Diagram 6 attached to By-law 700-2021(OLT)

  23. Rule X

    All non-residential parking and residential visitor parking may be provided on a non-exclusive, shared basis according to the occupancy rates listed below: (i) residential visitors: (a) morning – 10 percent; (b) afternoon – 35 percent; and (c) evening – 100 percent; (ii) non-residential uses: (a) morning – 20 percent; (b) afternoon – 100 percent; and (c) evening – 75 percent.

  24. Rule Y

    Parking spaces for non-residential and residential visitor uses may be provided in a public parking garage below ground

  25. Rule Z

    Despite Regulation 200.15.10(1), a minimum of 4 accessible parking spaces must be provided plus 1 accessible parking space for every 50 required parking spaces or part thereof; and (i) Despite 200.15.1(1), 200.15.1(3),200.15.1(4) and By-law 579-2017, an accessible parking space must comply with the following: (a) the minimum required width of an accessible parking space is 3.9 metres; and (b) accessible parking spaces must be the parking spaces closest to a barrier free: i) entrance to a building ; ii) passenger elevator that provides access to the first storey of the building ; and iii) shortest route from the required entrances in b. i., and ii., above

  26. Rule AA

    Despite Regulation 230.5.10.1(1) and Table 230.5.10.1(1), bicycle parking spaces must be provided in accordance with the following: (i) a minimum of 0.9 "long-term" bicycle parking spaces per dwelling unit for residents; (ii) a minimum of 0.1 "short-term" bicycle parking spaces per dwelling unit for residential visitors; (iii) a minimum of 0.2 "long-term" bicycle parking spaces per 100 square metres interior floor area for retail stores , personal service shops , and eating establishments and take-out eating establishments ; (iv) a minimum of 3 plus 0.3 "short-term" bicycle parking spaces per 100 square metres interior floor area for retail stores , personal service shops , and eating establishments ; (v) a minimum of 0.2 "long-term" bicycle parking spaces per 100 square metres interior floor area for office uses; (vi) a minimum of 3 plus 0.2 "short-term" bicycle parking spaces per 100 square metres interior floor area for office uses; (vii) a minimum of 0.1 "long-term" bicycle parking spaces per 100 square metres interior floor area for community centre or day nursery uses; (viii) a minimum of 3 plus 0.1 "short-term" bicycle parking spaces per 100 square metres interior floor area for community centre or day nursery uses; and (ix) no "long-term" bicycle parking spaces or "short-term" bicycle parking spaces will be required for any of the residential dwelling units within Block F as shown on Diagram 6 attached to By-law 700-2021(OLT); (BB) Despite Regulation 230.5.1.10 (7), no shower and change facilities are required; (CC) Despite Regulation 230.5.1.10(10), a "long-term" bicycle parking space and "short-term" bicycle parking space may be provided in a stacked bicycle parking space provided the minimum dimensions are: (i) a minimum vertical clearance of 1.2 metres; (ii) a minimum width of 0.45 metres; and (iii) a minimum length of 1.8 metres; (DD) Despite Regulations 220.5.10.1(2), (3), (4), (5) and (8), loading spaces must be provided in accordance with the following: (i) a minimum of one (1) Type 'G' loading space and one (1) Type 'B' loading space must be provided for use in conjunction with building A, building B1 and building B2; and (ii) a combined minimum of an additional three (3) Type 'B' loading spaces and five (5) Type 'C' loading spaces must be provided anywhere within Block A, Block B, Block C, Block D, and Block E: (a) additional loading spaces must be provided at a rate of one (1) loading spaces Type 'B' for each 46,600 square metres of residential and non-residential gross floor area ; and (b) additional loading spaces must be provided at a rate of one (1) loading spaces Type 'C' for each 29,650 square metres of residential and non-residential gross floor area ; and (iii) zero (0) loading spaces are required for or within Block F as shown on Diagram 6 attached to By-law 700-2021(OLT); (EE) Despite regulation 220.5.20.1(2), access to loading spaces provided below-ground, including Type 'G' loading spaces , may be provided via a ramp with a maximum grade of 12 percent; (FF) Despite Regulation 5.10.30.1(1), within the lands shown on Diagram 1 attached to By-law 700-2021(OLT) no building or structure may be erected or used: (i) unless the street identified as Public Street on Diagram 6 of By-law 700-2021(OLT), is constructed to a minimum base curb and base asphalt or concrete and is connected to an existing street ; (ii) unless all Municipal water mains and Municipal sewers, and their appurtenances, are installed within the street identified as Public Street on Diagram 6 attached to By-law 700-2021(OLT), and are operational; and (iii) building F as shown on Diagram 7 attached to By-law 700-2021(OLT) and below-ground structures and foundations located on any of the Blocks as shown on Diagram 6 attached to By-law 700-2021(OLT), are not subject to the restrictions of Provisions (FF)(i) and (ii) above; and (GG) the issuance of above-grade building permits are subject to the following: (i) prior to issuance of any above-grade building permit for building A, building B1, building B2, building C, building D, and building E as shown on Diagram 6 and 7 attached to By-law 700-2021(OLT), the street identified as Public Street on Diagram 6 of By-law 700-2021(OLT) must be conveyed to the City; and (ii) prior to issuance of any above-grade building permit for building C, building D, and building E as shown on Diagram 6 and 7 attached to By-law 700-2021(OLT), the lands zoned OR (x29) on Diagram 2 and labelled as "Public Park" on Diagram 6 of By-law 700-2021(OLT) must be conveyed to the City.

1 part for other addresses
  • A On lands municipally known as 1141 Bloor Street West, 980 Dufferin Street and 90 Croatia Street in the year 2020, if the requirements By-law 700-2021(OLT) …
By-law 569-2013, Chapter 900

Lot facts

Area
7,517 m²
Frontage
98.8 mestimated, irregular lot
Depth
155.6 mestimated, irregular lot
Street
Bloor St W
Corner lot
Yes, also on Collegiate Rd155.6 m along it
Public lane
None
House footprint
574 m²roof up to 29.3 m
Back yard
74.3 mhouse to rear lot line
Side yards
19.8 m and 55.7 mhouse to side lot lines
Buildings on the lot
9house, garage, sheds
Max height
16 m
Max lot coverage
—

House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.

  • Site and Area Specific Policy 581. The Official Plan has a policy for this site or area that varies the general rules. Read it before relying on zoning alone. Source
  • Major Transit Station Area: Dufferin. The lot is inside the Dufferin Major Transit Station Area approved by the Province (Site and Area Specific Policy 658). Source
  • Zone CR 3.0 (c1.0; r2.0) SS2 (x373) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source

Around this lot

Minor variances approved
93%37 of 40 decisions
Garden suite permits
4
Laneway suite permits
14
Multiplex permits
15
Development applications
17

Within 300 m, last 10 years. 33 suite and multiplex permits: more than at 95% of Toronto houses (median 3). 40 variance decisions: more than at 75% of Toronto houses (median 19).

Recent variance decisions in the same zone

  • Minor varianceApproved

    To alter the development standards under Site Specific Zoning By-Law 700-2021 (OLT) for the approved mixed-use redevelopment, with respect to the above-grade building permits, as well as the construction of the development block, public street, and municipal services.

    1141 BLOOR ST W · Dec 13, 2023 · 47 m away
  • Minor varianceApproved

    To permit the existing parking deficiency and to permit a rear yard setback deficiency for the existing commercial building (Dufferin Mall).

    900 DUFFERIN ST · Feb 23, 2022 · 353 m away
  • Minor varianceApproved

    To permit the existing parking deficiency and to permit a north side yard setback deficiency for the existing commercial building (Dufferin Mall).

    900 DUFFERIN ST · Feb 23, 2022 · 353 m away
  • Minor varianceApproved

    To alter an existing two-storey mixed-use building, containing one dwelling unit, into a three-storey mixed-use building containing two dwelling units by constructing: a third storey addition, a rear three-storey addition, and a rooftop terrace. Two rear parking spaces are proposed.

    1245 BLOOR ST W · Aug 4, 2021 · 375 m away
  • Minor varianceApproved

    To construct a detached double car garage at the rear of the existing two-storey mixed-use building.

    1190 BLOOR ST W · Mar 17, 2021 · 127 m away

Latest activity nearby

  • Building permit

    Proposal to construct an attached roof above an existing deck in rear yard.

    661 BROCK AVE · Nov 18, 2026 · 272 m away
  • Building permit

    Interior renovation for a noodle restaurant, including building plumbing and HVAC work

    90 CROATIA ST · Nov 12, 2026 · 120 m away
  • Zoning review

    Closed

    1084 BLOOR ST W · Nov 6, 2026 · 287 m away
  • Building permit

    Interior alterations for a proposed new take out restaurant.

    980 DUFFERIN ST · Nov 4, 2026 · 96 m away
  • Building permit

    Rev 01: Changed from a new riser for the lobby/gym sprinklers to altering the existing and upsizing. Proposal for new sprinkler system in existing lobby.

    919 DUFFERIN ST · Nov 3, 2026 · 256 m away
  • Zoning review

    Closed

    634 BROCK AVE · Nov 2, 2026 · 249 m away
  • Building permitmultiplex, new building, new house

    Revision No.1:PROPOSED RESIDENTIAL SIXPLEX(BASEMENT+3 STOREY)

    999 DUFFERIN ST · Nov 2, 2026 · 144 m away
  • Building permit

    Admin partywall permit in conjunction with 25 102323 01 BLD, 508 Brock Ave.

    510 BROCK AVE · Oct 30, 2026 · 295 m away
  • Zoning review

    Closed

    1108 BLOOR ST W · Oct 27, 2026 · 213 m away
  • Zoning review

    Notice Sent

    1101 BLOOR ST W · Oct 23, 2026 · 242 m away

Neighbourhood: Dufferin Grove

About the area around the lot, not the lot itself.

Nearest station
Dufferin Station3 min walk
Nearest TTC stop
Bloor St West at Dufferin St2 min walk
Nearest cycling route
Bloor St WCycle Track, 1 min walk
Nearest traffic count
9,818 vehicles in 8 hBloor St W / Collegiate Rd / Pauline Ave, 100 m away, Oct 22, 2019
Serious collisions within 500 m
72021–2026, killed or seriously injured: 1 fatal, 4 with pedestrians, 2 with cyclists
Parks
Susan Tibaldi Parkette3 min walk
Dufferin Grove Park5 min walk
Salem Parkette8 min walk

Schools within 1 km

  • BLOOR C.I. & ALPHA II ALTERNATIVE English Public 1 min walk
  • ST MARY CATHOLIC ACADEMY SECONDARY SCHOOL English Separate 6 min walk
  • PAULINE JR PUBLIC SCHOOL English Public 7 min walk
  • ST SEBASTIAN CATHOLIC ELEMENTARY SCHOOL English Separate 8 min walk
  • ST ANTHONY CATHOLIC ELEMENTARY SCHOOL English Separate 9 min walk
  • BROCK JR PUBLIC SCHOOL English Public 11 min walk

Being near a school does not mean the lot is in its catchment; check with the board.

2021 Census

FigureDufferin GroveMedian neighbourhood
Median household income (2020)$78,000$84,500
Households that own their home42%54%
Population (2021)11,21516,813
Homes built in 1960 or before56%29%
Homes needing major repairs10%7%

Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.

Police-reported crime, 2025

Per 100,000 peopleDufferin GroveCity median
Assault1224.5636.3
Robbery111.369.5
Auto theft111.3192.6
Theft over $5,00087.546.1
Break and enter270.3172.8
Theft from vehicles278.3188.1

Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.

Something here not right?

Sources

  • Building permits on this lot since 2000: Permits issued or applied for since about 2000, with status.
  • Committee of Adjustment files since 2001: Minor variances and consents (lot splits) on this lot and nearby, with decisions.
  • Development applications: Rezoning, site plan, subdivision and condominium applications.
  • Preliminary zoning reviews: Zoning reviews requested before a permit or variance application.
  • Zoning and overlays: Zoning By-law 569-2013 zone, height, coverage, policy area, parking, rooming house, priority retail street and downtown setback overlays.
  • Lot boundary, street and lane: Lot polygon, its addresses, the street it fronts, corner and public lane contact, with frontage and depth measured from the boundary; City of Toronto land in City use, which is not a home.
  • House and yards: Footprint and roof height of the house and other buildings, and the yard behind the house, from the City's 3D Massing (updated yearly, illustrative).
  • City trees in front of the lot: City-owned trees on the street allowance at this address, with species and trunk diameter. Private trees on the lot are not in open data.
  • Heritage: Heritage Register (listed and designated properties), Official Plan Amendment 720 properties and properties removed from the Register under the 2022 two-year limit.
  • TRCA regulated area: Valleys, floodplains, shorelines and wetlands regulated by the Toronto and Region Conservation Authority.
  • Ravines and natural features: Ravine and Natural Feature Protection area (Chapter 658, map last published 2019), Natural Heritage System and Environmentally Significant Areas.
  • Official Plan policies: Site and Area Specific Policies, Secondary Plans and Major Transit Station Areas covering the lot.
  • Rooming houses, short-term rentals and rental buildings: Multi-tenant house licences, short-term rental registrations and RentSafeTO evaluations at this address.
  • Neighbourhood context: Neighbourhood, 2021 Census figures, police-reported crime rates, schools, parks, TTC stops, cycling routes, serious collisions and traffic counts nearby. Area context only, not a finding about the lot.
  • Orders and by-law investigations: Outstanding Toronto Building orders, and by-law investigations open now or closed in the last two years. Fire and Public Health orders and older closed files are not published.
  • Address points: loaded Nov 22, 2026, published Nov 20, 2026
  • Toronto Building orders: loaded Nov 27, 2026, published Nov 26, 2026
  • Neighbourhood Profiles, 2021 Census: loaded Oct 14, 2026, published Oct 6, 2023
  • Street centrelines: loaded Nov 22, 2026, published Nov 20, 2026
  • City-owned land: loaded Nov 22, 2026, published Nov 16, 2026
  • Committee of Adjustment open applications: loaded Nov 27, 2026, published Nov 26, 2026
  • Committee of Adjustment decisions: loaded Nov 27, 2026, published Nov 26, 2026
  • Committee of Adjustment decisions 2001-2016: loaded Oct 14, 2026, published Feb 20, 2026
  • Collisions with people killed or seriously injured (Toronto Police Service): loaded Nov 22, 2026, published Nov 21, 2026
  • Neighbourhood crime rates (Toronto Police Service): loaded Oct 14, 2026, published Feb 20, 2026
  • Cycling network: loaded Nov 22, 2026, published Nov 16, 2026
  • Development applications: loaded Nov 27, 2026, published Nov 27, 2026
  • Environmentally Significant Areas: loaded Oct 14, 2026, published Mar 16, 2026
  • Green spaces: loaded Nov 15, 2026, published Nov 10, 2026
  • Heritage register: loaded Oct 14, 2026, published Sep 1, 2026
  • Former heritage listings: loaded Oct 14, 2026, published Jul 3, 2025
  • Official Plan Amendment 720 heritage list: loaded Oct 14, 2026, published Sep 1, 2026
  • 3D Massing building footprints: loaded Oct 14, 2026, published Dec 2, 2025
  • By-law investigation addresses: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigation deficiencies: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigations: loaded Nov 27, 2026, published Nov 26, 2026
  • Major Transit Station Areas: loaded Oct 14, 2026, published Feb 3, 2026
  • Natural Heritage System: loaded Oct 14, 2026, published Mar 16, 2026
  • Neighbourhoods: loaded Oct 14, 2026, published Feb 20, 2026
  • Property boundaries: loaded Nov 27, 2026, published Nov 27, 2026
  • Active building permits: loaded Nov 27, 2026, published Nov 26, 2026
  • Cleared building permits: loaded Nov 27, 2026, published Nov 26, 2026
  • Cleared building permits 2000-2016: loaded Oct 14, 2026, published Jul 8, 2025
  • Preliminary zoning reviews: loaded Nov 27, 2026, published Nov 26, 2026
  • Ravine and natural feature protection: loaded Oct 14, 2026, published Jul 23, 2019
  • RentSafeTO evaluations: loaded Nov 27, 2026, published Nov 26, 2026
  • Multi-tenant house licences: loaded Nov 27, 2026, published Nov 26, 2026
  • Site and Area Specific Policies: loaded Oct 14, 2026, published Mar 16, 2026
  • School locations: loaded Oct 14, 2026, published May 27, 2026
  • Secondary Plans: loaded Oct 14, 2026, published Mar 16, 2026
  • Street trees: loaded Oct 14, 2026, published Jun 4, 2026
  • Short-term rental registrations: loaded Nov 27, 2026, published Nov 26, 2026
  • Traffic counts at intersections: loaded Nov 22, 2026, published Nov 21, 2026
  • TRCA regulation limit: loaded Oct 14, 2026, published Apr 29, 2026
  • TTC stops (GTFS): loaded Nov 8, 2026, published Nov 5, 2026
  • Zoning by-law: loaded Oct 14, 2026, published Feb 20, 2026
  • Lot coverage overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Height overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Parking zone overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Policy area overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Priority retail streets: loaded Oct 14, 2026, published Feb 20, 2026
  • Rooming house overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Zoning setbacks: loaded Oct 14, 2026, published Feb 20, 2026

Contains information licensed under the Open Government Licence – Toronto. TRCA regulation limit © TRCA.

Screening tool based on City of Toronto and TRCA open data. Not a zoning review or legal opinion. Site-specific exceptions, amendments not yet in the open data, minor variances and other by-laws can change the answer. Confirm with a Preliminary Project Review or Zoning Certificate from Toronto Building before buying or designing.

Flag an error

What is not right?

The problem

The records come from the City's open data; we check each flag against them. Your email is used only to answer this.