HousePrecheckCheck an address

4 Montgomery RdToronto · zoning, lot size and permit records

Also 4 Montgomery Rd

(H) CR 2.0 (c0.5; r2.0) SS2 (x781)≈ 25.6 × 49.1 m836 m²on Montgomery Rdcorner, also on Birchview Blvd

Not a home

Land without a building

A demolition permit (26 129435, 2026) is on file and no permit for a new building: the land is probably empty or used for parking. It is not a home for sale, so the house checks and the pre-offer report do not apply.

Looking at a house nearby? What this means for you

  • Empty land or parkingWhat gets built here matters most to the street: read the applications on it and around it below.
  • Permits or applications open on this parcelRecent records on this lot: 26 129435 (Proposal for demolition permit to make way for a future mixed-use condominium developme..., 2026); 21 229300 WET 03 CD (*** Proposed 13 storey mixed use building containing 319 residential units, 2021); 21 133565 WET 03 SA (The proposed development consists of a 16-storey mixed-use building comprised of reside..., 2021); and 1 more. Larger work can mean noise and trucks next door; read what each one is for.
  • 3 development applications open within 300 m, up to 16 storeysNew buildings may go up around here in the next years. More change nearby than at 81% of Toronto houses.
  • Major Transit Station Area: IslingtonThe City plans more homes around the station: good for transit, and more building over time.
N20 m
≈ 25.6 m frontage≈ 49.1 m deepirregular lot, estimated

Before you offer

From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.

  • TRCA regulated area (100% of lot)

    Needs a closer look

    Part of the lot is near a valley, floodplain, shoreline or wetland. Work there needs a TRCA permit and may be restricted.

    What it means. Additions, pools and new buildings in the regulated part need a TRCA permit and may be refused. Ask your insurer about flood coverage.

    How to confirm. A TRCA property inquiry letter says which policies apply ($385, at least two weeks). Details

    Ontario Regulation 41/24, TRCA Regulation Limit
  • Ravine and natural feature protection (98% of lot)

    Needs a closer look

    Part of the lot is in the area covered by the City's Ravine and Natural Feature Protection By-law. The City's map of the area was last published in 2019.

    What it means. In that part, injuring or removing a tree of any size, grading, filling or dumping needs a City permit. Plans for a pool, addition or garden suite there may be refused.

    How to confirm. Urban Forestry confirms where the protected area runs and whether work needs a permit. Details

    Toronto Municipal Code, Chapter 658
  • Natural Heritage System (100% of lot)

    Good to know

    Part of the lot is in the Natural Heritage System shown on Official Plan Map 9.

    What it means. New buildings or additions in that part need a natural heritage impact study.

    How to confirm. City Planning confirms the policies that apply. Details

    City of Toronto Official Plan, Map 9
  • Work or applications in progress

    Good to know

    Recent records on this lot: 26 129435 (Proposal for demolition permit to make way for a future mixed-use condominium developme..., 2026); 21 229300 WET 03 CD (*** Proposed 13 storey mixed use building containing 319 residential units, 2021); 21 133565 WET 03 SA (The proposed development consists of a 16-storey mixed-use building comprised of reside..., 2021); and 1 more.

    What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.

    How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details

    City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications
  • 3 development applications open within 300 m

    Good to know

    3 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 16 storeys. They are listed under Around this lot.

    What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.

    How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details

    City of Toronto, Development Applications

Not in these records

  • Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
  • Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.

History of this lot

5 records on file: more than at 93% of Toronto houses (median 0).

  • Building permit26 129435Permit Issueddemolition

    Proposal for demolition permit to make way for a future mixed-use condominium development, which includes the lands at 3100 Bloor Street West, and 4-8 Montgomery Road.

    May 5, 2026 · 4 MONTGOMERY RD
  • Building permit23 108992Cancelleddemolition

    Proposal to demolish the existing house for a new development related to 21 133565 WET 03 SA.

    Jan 31, 2023 · 4 MONTGOMERY RD
  • Development application21 229300 WET 03 CDUnder Review

    *** Proposed 13 storey mixed use building containing 319 residential units.

    Oct 22, 2021 · 4 MONTGOMERY RD · City file
  • Development application21 133565 WET 03 SAUnder Review

    The proposed development consists of a 16-storey mixed-use building comprised of residential and commercial uses at grade, and residential uses above. The building would provide a total of 347 residential units and a total gross floor area of 38,136 square metres.

    Mar 29, 2021 · 4 MONTGOMERY RD · City file
  • Development application20 151103 WET 03 OZOMB Approved

    The proposed development consists of a 16-storey mixed-use building comprised of residential and commercial uses at grade, and residential uses above.

    Jun 1, 2020 · 4 MONTGOMERY RD · City file

Check before you build

  • Site-specific exception 900.11.10(781)

    Needs a closer look

    25 site-specific rules and 25 older by-laws that still prevail apply to this lot. They can override the standard rules on this page. 2 parts are limited to an area drawn on a by-law diagram; check whether this lot is in it.

    Zoning By-law 569-2013, Chapter 900
  • Holding provision (H)

    Needs a closer look

    Development is on hold until the conditions of the holding by-law are met.

    Zoning By-law 569-2013
Exception 900.11.10(781)Applies

These parts of the exception apply to this lot's address.

  1. Rule A · diagram area

    On the lands known municipally as part of 3100-3200 Bloor Street West and 4-8 Montgomery Road, shown as Part A and Part B on Diagram 1, if the requirements of Sections 13, 14 and Schedule A of By-law 1187-2022(OLT) are complied with, a building or structure may be constructed, used or enlarged in compliance with Regulations

  2. Rule B

    to (Z) below; (B) For the purpose of this exception, the lot is comprised of the lands shown as Part A and Part B on Diagram 1 of By-law 1187-2022(OLT)

  3. Rule C

    Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area of all buildings and structures on the lot is 38,140 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 37,700 square metres; and (ii) the required minimum gross floor area for non-residential uses is 440 square metres

  4. Rule D

    The permitted maximum "floor plate area" of each storey of a "tower" is 825 square metres, and for the purpose of this exception: (i) "floor plate area" means the total built area within a "tower", measured from the exterior of the main walls on each storey, excluding balconies; and (ii) despite Regulation 40.5.40.10(8)(C), "tower" means the portion of a building with a height equal to or greater than 36.0 metres

  5. Rule E

    In addition to the elements which reduce gross floor area in a mixed use building listed in Regulation 40.5.40.40(3), gross floor area is also reduced by the area in a building used for: (i) all bicycle parking provided at and above ground level; (ii) storage rooms and areas, waste collection and recycling areas, electrical, utility, mechanical, and ventilation rooms and areas, provided below, at or above ground level; (iii) ventilation ducts, utility shafts, and vehicular ramps; (iv) all indoor amenity space ; (v) the area of a void in a floor if there is a vertical clearance of more than 2.95 metres between the top of the floor below the void and the ceiling directly above it; and (vi) all inset balconies

  6. Rule F

    Despite Regulation 40.10.30.40(1), the permitted maximum lot coverage , as a percentage of the lot area is 75 percent

  7. Rule G

    Regulations 40.10.40.1(1) and (3), with respect to the location of residential and non-residential uses in a mixed use building and with respect to residential use orientation to a street and requirements for direct access to a street , do not apply

  8. Rule H

    A minimum of 50 percent of the length of the first storey of the exterior building main wall along Bloor Street West, commencing from the eastern-most point of the main wall , must be used for non-residential uses as listed in Regulations 40.10.20.10(1)(A) and 40.10.20.20(1)(A). For the purpose of this Regulation, the extent of the main wall along Bloor Street West is as shown on Diagram 6

  9. Rule I

    Despite Regulation 40.10.40.1(2), the floor level of the portion of a first storey that accommodates a non-residential use must be within 0.2 metres of the ground measured at 1.0 metres outside of each pedestrian entrance to such non-residential use

  10. Rule J

    Regulation 40.10.40.10(5), regarding the required minimum height of the first storey of non-residential uses, measured between the floor of the first storey and floor of the second storey , is 4.5 metres. The required minimum height of the first storey does not apply to residential uses

  11. Rule K

    For the purpose of this exception, Clause 150.100.30.1 does not apply

  12. Rule L

    Despite Regulations 40.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum elevation of 117.50 metres and the elevation of the highest point of the building or structure

  13. Rule M

    Despite Regulations 40.10.40.10(2) and (7), the permitted maximum height of a building or structure is the number in metres following the letters "HT" and the permitted maximum storeys of a building or structure is the number following the letters "ST" as shown on Diagram 6 of By-law 1187-2022(OLT) provided that for the purpose of this exception a mezzanine and a mechanical penthouse is not a storey

  14. Rule N

    Despite Regulations 40.5.40.10(3) to (8), 40.5.75.1(2) and (M) above, the following building elements, equipment and structures may project beyond the permitted maximum heights shown on Diagram 6 of By-law 1187-2022(OLT), and if located on a rooftop such building elements, equipment and structures are not subject to area, coverage, horizontal dimension or locational restrictions: (i) equipment used for the functional operation of the building including electrical, utility, mechanical and ventilation equipment, enclosed stairwells, roof access, maintenance equipment storage, elevator shafts, chimneys, and vents, by a maximum of 6.5 metres; (ii) structures that enclose, screen or cover the equipment, structures and parts of a building listed in (i) above, inclusive of a mechanical penthouse, by a maximum of 6.5 metres; (iii) architectural feature at the southwest corner of the "tower", by a maximum height of 6.5 metres; (iv) architectural features, parapets, and elements and structures associated with a green roof , by a maximum of 2.0 metres; (v) building maintenance units and window washing equipment, by a maximum of 3.5 metres; (vi) planters, landscaping features, guard rails, and divider screens on a balcony and/or terrace, by a maximum of 3.0 metres; (vii) trellises, pergolas, and unenclosed structures providing safety or wind protection to rooftop amenity space , and mitigation structures and features by a maximum of 4.0 metres; (viii) building elements and structures such as railings, balustrades, eaves, roof drainage, balcony and terrace guards, fences, skylights, cornices, seating areas, decorative screens, privacy screens, access ramps, and ramps to underground, by a maximum of 3.0 metres; (ix) building elements, structures and equipment used for outdoor amenity space or open-air recreation including pools and associated equipment, light monitors, light fixtures, by a maximum of 4.0 metres; (x) building elements and structures such as canopies, awnings, and related architectural elements by a maximum of 6.0 metres; (xi) heating/cooling, and building elements and devices, maintenance equipment storage, public art, by a maximum of 6.5 metres; and (xii) elevator overruns, lightning rods, stacks, flues, air intakes, antennas, satellite dishes, cellular arrays, flagpoles, solar panels and related equipment, by a maximum of 7.0 metres

  15. Rule O

    Despite Clause 40.10.40.80 and Regulations 40.10.40.70(2) and (4), the required minimum building setbacks , including any portion of a building with dwelling units located in the first storey of a building , are as shown in metres on Diagram 6 of By-law 1187-2022(OLT) and no angular planes or minimum distance between the main walls requirements apply

  16. Rule P

    Despite Clause 40.10.40.60, Regulation 5.10.40.70(1) and (O) above, the following elements may encroach into the required minimum building setbacks and main wall separation distances shown on Diagram 6 of By-law 1187-2022(OLT) as follows: (i) decks, porches, patios and balconies, by a maximum of 2.0 metres; (ii) despite (i) above, patios associated with dwelling units not facing a street, by a maximum of 3.0 metres; (iii) canopies and awnings, guardrails, balustrades, railings, and light fixtures by a maximum of 3.0 metres; (iv) exterior stairs, access ramps and elevating devices; (v) architectural features, such as a pilaster, decorative column, cornice, sill, belt course, or chimney breast, by a maximum of 0.6 metres; (vi) window projections, including bay windows and box windows, by a maximum of 1.0 metre; (vii) eaves, by a maximum of 0.6 metre; (viii) air conditioners, satellite dishes, antennae, vents, and pipes, lightning rods and flag poles, by a maximum of 1.0 metre; (ix) pergolas and cabanas, by a maximum of 3.0 metres, and 0.0 metres when facing the lot line abutting Montgomery Road and Bloor Street West; (x) landscaping , planters, public art, structures and equipment used for outdoor amenity space or open air recreation, patios, air vents, air shafts/intakes, site mechanical and servicing features, elements required for the functional operation of a building, fences, screens, safety and wind mitigation elements, and window washing equipment, including a Building Maintenance Unit and crane; and (xi) building elements and structures such as parapets, trellises, pillars, and damper equipment to reduce building movement, by a maximum of 2.5 metres

  17. Rule Q

    Despite Regulations 40.5.40.60(1) and 40.10.40.60(2) and (P)(iii) above, a canopy, awning or similar structure , with or without structural support, may encroach by a maximum of 3.0 metres into a required minimum building setback that abuts a street , if no part of the canopy, awning or similar structure is located more than 8.0 metres above the elevation of the ground directly below it

  18. Rule R

    Despite Regulation 5.10.40.70(2): (i) buildings or structures below ground must be setback a minimum of 3.0 metres from a lot line abutting an ON zone; and (ii) buildings or structures below ground must be setback a minimum of 3.0 metres from the lot line abutting the "TTC Bloor Line" as shown on Diagram 1 of By-law 1187-2022(OLT)

  19. Rule S

    Of the total number of dwelling units provided on the lot : (i) a minimum of 10 percent of the total dwelling units must be 3-bedroom units or greater; and (ii) a minimum of 15 percent of the total dwelling units must be 2-bedrooms units

  20. Rule T

    Clause 40.10.50.10 regarding landscaping does not apply

  21. Rule U

    Despite Regulations 200.5.10.1(1) and Table 200.5.10.1, parking spaces must be provided in accordance with the following: (i) a minimum of 1.05 residential occupant parking spaces for each dwelling unit ; (ii) a minimum of 0.15 residential visitor parking spaces for each dwelling unit ; and (iii) a minimum of 1.0 parking space for each 100 square metres of non-residential gross floor area

  22. Rule V

    Despite Regulations 200.5.1.10(2)(A) and (D), equipment for the charging of one electric vehicle is permitted within a parking space , subject to the equipment being located in the same parking space as the vehicle to be charged and: (i) being within 0.25 metres of two adjoining sides of the parking space which are not adjacent and parallel to a drive aisle from which vehicle access is provided, measured at right angles; or (ii) being at least 5.35 metres from a drive aisle from which vehicle access is provided, measured at right angles, and at least 1.0 metre from the ground

  23. Rule W

    Despite Regulation 200.5.10.1(1) and (U)(i) above, "car-share parking spaces" may be provided and for each "car-share parking space" provided the number of required parking spaces for residential occupants may be reduced by four (4) parking spaces , exclusive of required accessible parking spaces , where for the purpose of this exception: (i) "car-share" means the practice whereby a number of people share the use of one or more motor vehicles and such car-share motor vehicles are made available to at least the occupants of the building for short term rental, including hourly rental; and (ii) a "car-share parking space" means a parking space exclusively used for "car-share" purposes

  24. Rule X

    Despite Regulations 200.15.1(1), (3) and (4) and 200.15.10(1) and (2), four parking spaces required pursuant to (U)(i) and (ii) above, must comply with all regulations below for an accessible parking space : (i) minimum length of 5.6 metres; (ii) minimum width of 3.4 metres; (iii) minimum vertical clearance of 2.1 metres; (iv) the entire length of one side of an accessible parking space must be adjacent to a 1.5 metre wide accessible barrier free aisle or path; and (v) an accessible parking space is not required to be the closest parking space to a barrier free entrance and/or main pedestrian access to a building or to a passenger elevator, or be the shortest route from such entrance or elevator, or be at the same level as the pedestrian entrance to the building

  25. Rule Y

    Despite Clauses 40.10.90.1 and 220.5.10.1, a minimum of one Type 'G' loading space must be provided and maintained on the lot

  26. Rule Z

    Despite Regulations 230.5.1.10(4)(A)(i) and (ii), 230.5.1.10(5)(A) and 230.5.1.10(4)(C), a stacked bicycle parking space must have the following minimum dimensions: (i) length of 1.6 metres; (ii) width of 0.3 metres; and (iii) vertical clearance of 1.1 metres; Prevailing By-laws and Prevailing Sections: (None Apply)

  27. Older by-law A · diagram area

    On the lands known municipally as part of 3100-3200 Bloor Street West and 4-8 Montgomery Road, shown as Part A and Part B on Diagram 1, if the requirements of Sections 13, 14 and Schedule A of By-law 1187-2022(OLT) are complied with, a building or structure may be constructed, used or enlarged in compliance with Regulations

  28. Older by-law B

    to (Z) below; (B) For the purpose of this exception, the lot is comprised of the lands shown as Part A and Part B on Diagram 1 of By-law 1187-2022(OLT)

  29. Older by-law C

    Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area of all buildings and structures on the lot is 38,140 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 37,700 square metres; and (ii) the required minimum gross floor area for non-residential uses is 440 square metres

  30. Older by-law D

    The permitted maximum "floor plate area" of each storey of a "tower" is 825 square metres, and for the purpose of this exception: (i) "floor plate area" means the total built area within a "tower", measured from the exterior of the main walls on each storey, excluding balconies; and (ii) despite Regulation 40.5.40.10(8)(C), "tower" means the portion of a building with a height equal to or greater than 36.0 metres

  31. Older by-law E

    In addition to the elements which reduce gross floor area in a mixed use building listed in Regulation 40.5.40.40(3), gross floor area is also reduced by the area in a building used for: (i) all bicycle parking provided at and above ground level; (ii) storage rooms and areas, waste collection and recycling areas, electrical, utility, mechanical, and ventilation rooms and areas, provided below, at or above ground level; (iii) ventilation ducts, utility shafts, and vehicular ramps; (iv) all indoor amenity space ; (v) the area of a void in a floor if there is a vertical clearance of more than 2.95 metres between the top of the floor below the void and the ceiling directly above it; and (vi) all inset balconies

  32. Older by-law F

    Despite Regulation 40.10.30.40(1), the permitted maximum lot coverage , as a percentage of the lot area is 75 percent

  33. Older by-law G

    Regulations 40.10.40.1(1) and (3), with respect to the location of residential and non-residential uses in a mixed use building and with respect to residential use orientation to a street and requirements for direct access to a street , do not apply

  34. Older by-law H

    A minimum of 50 percent of the length of the first storey of the exterior building main wall along Bloor Street West, commencing from the eastern-most point of the main wall , must be used for non-residential uses as listed in Regulations 40.10.20.10(1)(A) and 40.10.20.20(1)(A). For the purpose of this Regulation, the extent of the main wall along Bloor Street West is as shown on Diagram 6

  35. Older by-law I

    Despite Regulation 40.10.40.1(2), the floor level of the portion of a first storey that accommodates a non-residential use must be within 0.2 metres of the ground measured at 1.0 metres outside of each pedestrian entrance to such non-residential use

  36. Older by-law J

    Regulation 40.10.40.10(5), regarding the required minimum height of the first storey of non-residential uses, measured between the floor of the first storey and floor of the second storey , is 4.5 metres. The required minimum height of the first storey does not apply to residential uses

  37. Older by-law K

    For the purpose of this exception, Clause 150.100.30.1 does not apply

  38. Older by-law L

    Despite Regulations 40.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum elevation of 117.50 metres and the elevation of the highest point of the building or structure

  39. Older by-law M

    Despite Regulations 40.10.40.10(2) and (7), the permitted maximum height of a building or structure is the number in metres following the letters "HT" and the permitted maximum storeys of a building or structure is the number following the letters "ST" as shown on Diagram 6 of By-law 1187-2022(OLT) provided that for the purpose of this exception a mezzanine and a mechanical penthouse is not a storey

  40. Older by-law N

    Despite Regulations 40.5.40.10(3) to (8), 40.5.75.1(2) and (M) above, the following building elements, equipment and structures may project beyond the permitted maximum heights shown on Diagram 6 of By-law 1187-2022(OLT), and if located on a rooftop such building elements, equipment and structures are not subject to area, coverage, horizontal dimension or locational restrictions: (i) equipment used for the functional operation of the building including electrical, utility, mechanical and ventilation equipment, enclosed stairwells, roof access, maintenance equipment storage, elevator shafts, chimneys, and vents, by a maximum of 6.5 metres; (ii) structures that enclose, screen or cover the equipment, structures and parts of a building listed in (i) above, inclusive of a mechanical penthouse, by a maximum of 6.5 metres; (iii) architectural feature at the southwest corner of the "tower", by a maximum height of 6.5 metres; (iv) architectural features, parapets, and elements and structures associated with a green roof , by a maximum of 2.0 metres; (v) building maintenance units and window washing equipment, by a maximum of 3.5 metres; (vi) planters, landscaping features, guard rails, and divider screens on a balcony and/or terrace, by a maximum of 3.0 metres; (vii) trellises, pergolas, and unenclosed structures providing safety or wind protection to rooftop amenity space , and mitigation structures and features by a maximum of 4.0 metres; (viii) building elements and structures such as railings, balustrades, eaves, roof drainage, balcony and terrace guards, fences, skylights, cornices, seating areas, decorative screens, privacy screens, access ramps, and ramps to underground, by a maximum of 3.0 metres; (ix) building elements, structures and equipment used for outdoor amenity space or open-air recreation including pools and associated equipment, light monitors, light fixtures, by a maximum of 4.0 metres; (x) building elements and structures such as canopies, awnings, and related architectural elements by a maximum of 6.0 metres; (xi) heating/cooling, and building elements and devices, maintenance equipment storage, public art, by a maximum of 6.5 metres; and (xii) elevator overruns, lightning rods, stacks, flues, air intakes, antennas, satellite dishes, cellular arrays, flagpoles, solar panels and related equipment, by a maximum of 7.0 metres

  41. Older by-law O

    Despite Clause 40.10.40.80 and Regulations 40.10.40.70(2) and (4), the required minimum building setbacks , including any portion of a building with dwelling units located in the first storey of a building , are as shown in metres on Diagram 6 of By-law 1187-2022(OLT) and no angular planes or minimum distance between the main walls requirements apply

  42. Older by-law P

    Despite Clause 40.10.40.60, Regulation 5.10.40.70(1) and (O) above, the following elements may encroach into the required minimum building setbacks and main wall separation distances shown on Diagram 6 of By-law 1187-2022(OLT) as follows: (i) decks, porches, patios and balconies, by a maximum of 2.0 metres; (ii) despite (i) above, patios associated with dwelling units not facing a street, by a maximum of 3.0 metres; (iii) canopies and awnings, guardrails, balustrades, railings, and light fixtures by a maximum of 3.0 metres; (iv) exterior stairs, access ramps and elevating devices; (v) architectural features, such as a pilaster, decorative column, cornice, sill, belt course, or chimney breast, by a maximum of 0.6 metres; (vi) window projections, including bay windows and box windows, by a maximum of 1.0 metre; (vii) eaves, by a maximum of 0.6 metre; (viii) air conditioners, satellite dishes, antennae, vents, and pipes, lightning rods and flag poles, by a maximum of 1.0 metre; (ix) pergolas and cabanas, by a maximum of 3.0 metres, and 0.0 metres when facing the lot line abutting Montgomery Road and Bloor Street West; (x) landscaping , planters, public art, structures and equipment used for outdoor amenity space or open air recreation, patios, air vents, air shafts/intakes, site mechanical and servicing features, elements required for the functional operation of a building, fences, screens, safety and wind mitigation elements, and window washing equipment, including a Building Maintenance Unit and crane; and (xi) building elements and structures such as parapets, trellises, pillars, and damper equipment to reduce building movement, by a maximum of 2.5 metres

  43. Older by-law Q

    Despite Regulations 40.5.40.60(1) and 40.10.40.60(2) and (P)(iii) above, a canopy, awning or similar structure , with or without structural support, may encroach by a maximum of 3.0 metres into a required minimum building setback that abuts a street , if no part of the canopy, awning or similar structure is located more than 8.0 metres above the elevation of the ground directly below it

  44. Older by-law R

    Despite Regulation 5.10.40.70(2): (i) buildings or structures below ground must be setback a minimum of 3.0 metres from a lot line abutting an ON zone; and (ii) buildings or structures below ground must be setback a minimum of 3.0 metres from the lot line abutting the "TTC Bloor Line" as shown on Diagram 1 of By-law 1187-2022(OLT)

  45. Older by-law S

    Of the total number of dwelling units provided on the lot : (i) a minimum of 10 percent of the total dwelling units must be 3-bedroom units or greater; and (ii) a minimum of 15 percent of the total dwelling units must be 2-bedrooms units

  46. Older by-law T

    Clause 40.10.50.10 regarding landscaping does not apply

  47. Older by-law U

    Despite Regulations 200.5.10.1(1) and Table 200.5.10.1, parking spaces must be provided in accordance with the following: (i) a minimum of 1.05 residential occupant parking spaces for each dwelling unit ; (ii) a minimum of 0.15 residential visitor parking spaces for each dwelling unit ; and (iii) a minimum of 1.0 parking space for each 100 square metres of non-residential gross floor area

  48. Older by-law V

    Despite Regulations 200.5.1.10(2)(A) and (D), equipment for the charging of one electric vehicle is permitted within a parking space , subject to the equipment being located in the same parking space as the vehicle to be charged and: (i) being within 0.25 metres of two adjoining sides of the parking space which are not adjacent and parallel to a drive aisle from which vehicle access is provided, measured at right angles; or (ii) being at least 5.35 metres from a drive aisle from which vehicle access is provided, measured at right angles, and at least 1.0 metre from the ground

  49. Older by-law W

    Despite Regulation 200.5.10.1(1) and (U)(i) above, "car-share parking spaces" may be provided and for each "car-share parking space" provided the number of required parking spaces for residential occupants may be reduced by four (4) parking spaces , exclusive of required accessible parking spaces , where for the purpose of this exception: (i) "car-share" means the practice whereby a number of people share the use of one or more motor vehicles and such car-share motor vehicles are made available to at least the occupants of the building for short term rental, including hourly rental; and (ii) a "car-share parking space" means a parking space exclusively used for "car-share" purposes

  50. Older by-law X

    Despite Regulations 200.15.1(1), (3) and (4) and 200.15.10(1) and (2), four parking spaces required pursuant to (U)(i) and (ii) above, must comply with all regulations below for an accessible parking space : (i) minimum length of 5.6 metres; (ii) minimum width of 3.4 metres; (iii) minimum vertical clearance of 2.1 metres; (iv) the entire length of one side of an accessible parking space must be adjacent to a 1.5 metre wide accessible barrier free aisle or path; and (v) an accessible parking space is not required to be the closest parking space to a barrier free entrance and/or main pedestrian access to a building or to a passenger elevator, or be the shortest route from such entrance or elevator, or be at the same level as the pedestrian entrance to the building

  51. Older by-law Y

    Despite Clauses 40.10.90.1 and 220.5.10.1, a minimum of one Type 'G' loading space must be provided and maintained on the lot

  52. Older by-law Z

    Despite Regulations 230.5.1.10(4)(A)(i) and (ii), 230.5.1.10(5)(A) and 230.5.1.10(4)(C), a stacked bicycle parking space must have the following minimum dimensions: (i) length of 1.6 metres; (ii) width of 0.3 metres; and (iii) vertical clearance of 1.1 metres; Prevailing By-laws and Prevailing Sections: (None Apply)

By-law 569-2013, Chapter 900

Lot facts

Area
836 m²
Frontage
25.6 mestimated, irregular lot
Depth
49.1 mestimated, irregular lot
Street
Montgomery Rd
Corner lot
Yes, also on Birchview Blvd49.1 m along it
Public lane
None
House footprint
Not showna new house or demolition permit since the City's 3D survey
Max height
9.5 m
Max lot coverage
30%

House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.

  • Site and Area Specific Policy 810. The Official Plan has a policy for this site or area that varies the general rules. Read it before relying on zoning alone. Source
  • Major Transit Station Area: Islington. The lot is inside the Islington Major Transit Station Area approved by the Province (Site and Area Specific Policy 627). Source
  • Zone (H) CR 2.0 (c0.5; r2.0) SS2 (x781) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source

Around this lot

Minor variances approved
97%35 of 36 decisions
Garden suite permits
1
Laneway suite permits
0
Multiplex permits
0
Development applications
4

Within 300 m, last 10 years. 1 suite and multiplex permits: no more than at most Toronto houses (median 3). 36 variance decisions: more than at 70% of Toronto houses (median 19).

Latest activity nearby

  • Building permit

    Proposed front porch replacement

    30 BIRCHVIEW BLVD · Oct 6, 2026 · 108 m away
  • Building permit

    Revision 1: Permit revision to amend the following: building envelope and interior assembly types; extension of North Stair to the basement; adding the tenanted Grooming suite to scope; revised layout to ground & 2nd floors; various updates to doors, windows & screens.Proposal for a three storey addition to existing building and interior alterations.

    3265 BLOOR ST W · Sep 24, 2026 · 216 m away
  • Zoning review

    Closed

    3267-3273 BLOOR ST W · Sep 11, 2026 · 232 m away
  • Zoning review

    Closed

    3267 BLOOR ST W · Jul 29, 2026 · 232 m away
  • Building permit

    Proposal for interior alterations to convert retail space to a restaurant (30 seats).

    3076 BLOOR ST W · Jul 10, 2026 · 101 m away
  • Building permit

    Back Water Valve on Sewer Line

    29 WHITE OAK BLVD · Jun 30, 2026 · 204 m away
  • Building permit

    Proposal to replace existing stairs in rear yard with a new deck and stairs.

    52 THOMPSON AVE · Jun 5, 2026 · 225 m away
  • Building permit

    Proposal to erecting SL250 trailer sage in the middle of Bloor St W (in front of 3082 Bloor Street West - Royal LePage) for an ourdoor street festival - Taste of the Kingsway (Friday September 11 - Sunday September 13 2026)

    3082 BLOOR ST W · Jun 1, 2026 · 83 m away
  • Building permitdemolition

    Proposal for demolition permit to make way for a future mixed-use condominium development, which includes the lands at 3100 Bloor Street West, and 4-8 Montgomery Road.

    8 MONTGOMERY RD · May 5, 2026 · 43 m away
  • Building permitdemolition

    Proposal for demolition permit to make way for a future mixed-use condominium development, which includes the lands at 3100 Bloor Street West, and 4-8 Montgomery Road.

    6 MONTGOMERY RD · May 5, 2026 · 25 m away

Neighbourhood: Kingsway South

About the area around the lot, not the lot itself.

Nearest station
Royal York Station7 min walk
Nearest TTC stop
Bloor St West at Montgomery Rd West Side1 min walk
Nearest cycling route
Bloor St WCycle Track, 1 min walk
Nearest traffic count
16,916 vehicles in 8 hBloor St W / Cosmo Rd, 70 m away, Nov 14, 2005
Serious collisions within 500 m
22021–2026, killed or seriously injured: 1 fatal, 2 with pedestrians, 0 with cyclists
Parks
Birchview Boulevard Parkette1 min walk
Tom Riley Park2 min walk
Trca Lands ( 80)2 min walk

Schools within 1 km

  • OUR LADY OF SORROWS CATHOLIC ELEMENTARY SCHOOL English Separate 5 min walk
  • ETOBICOKE COLLEGIATE INSTITUTE English Public 11 min walk
  • THE LEARNING COMMON Private 11 min walk
  • SUNNYLEA JR SCHOOL English Public 14 min walk

Being near a school does not mean the lot is in its catchment; check with the board.

2021 Census

FigureKingsway SouthMedian neighbourhood
Median household income (2020)$184,000$84,500
Households that own their home81%54%
Population (2021)8,85516,813
Homes built in 1960 or before59%29%
Homes needing major repairs6%7%

Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.

Police-reported crime, 2025

Per 100,000 peopleKingsway SouthCity median
Assault513.1636.3
Robbery2969.5
Auto theft125.9192.6
Theft over $5,00058.146.1
Break and enter271.1172.8
Theft from vehicles48.4188.1

Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.

Something here not right?

Sources

  • Building permits on this lot since 2000: Permits issued or applied for since about 2000, with status.
  • Committee of Adjustment files since 2001: Minor variances and consents (lot splits) on this lot and nearby, with decisions.
  • Development applications: Rezoning, site plan, subdivision and condominium applications.
  • Preliminary zoning reviews: Zoning reviews requested before a permit or variance application.
  • Zoning and overlays: Zoning By-law 569-2013 zone, height, coverage, policy area, parking, rooming house, priority retail street and downtown setback overlays.
  • Lot boundary, street and lane: Lot polygon, its addresses, the street it fronts, corner and public lane contact, with frontage and depth measured from the boundary; City of Toronto land in City use, which is not a home.
  • House and yards: Footprint and roof height of the house and other buildings, and the yard behind the house, from the City's 3D Massing (updated yearly, illustrative).
  • City trees in front of the lot: City-owned trees on the street allowance at this address, with species and trunk diameter. Private trees on the lot are not in open data.
  • Heritage: Heritage Register (listed and designated properties), Official Plan Amendment 720 properties and properties removed from the Register under the 2022 two-year limit.
  • TRCA regulated area: Valleys, floodplains, shorelines and wetlands regulated by the Toronto and Region Conservation Authority.
  • Ravines and natural features: Ravine and Natural Feature Protection area (Chapter 658, map last published 2019), Natural Heritage System and Environmentally Significant Areas.
  • Official Plan policies: Site and Area Specific Policies, Secondary Plans and Major Transit Station Areas covering the lot.
  • Rooming houses, short-term rentals and rental buildings: Multi-tenant house licences, short-term rental registrations and RentSafeTO evaluations at this address.
  • Neighbourhood context: Neighbourhood, 2021 Census figures, police-reported crime rates, schools, parks, TTC stops, cycling routes, serious collisions and traffic counts nearby. Area context only, not a finding about the lot.
  • Orders and by-law investigations: Outstanding Toronto Building orders, and by-law investigations open now or closed in the last two years. Fire and Public Health orders and older closed files are not published.
  • Address points: loaded Nov 22, 2026, published Nov 20, 2026
  • Toronto Building orders: loaded Nov 28, 2026, published Nov 27, 2026
  • Neighbourhood Profiles, 2021 Census: loaded Oct 14, 2026, published Oct 6, 2023
  • Street centrelines: loaded Nov 22, 2026, published Nov 20, 2026
  • City-owned land: loaded Nov 22, 2026, published Nov 16, 2026
  • Committee of Adjustment open applications: loaded Nov 28, 2026, published Nov 27, 2026
  • Committee of Adjustment decisions: loaded Nov 28, 2026, published Nov 27, 2026
  • Committee of Adjustment decisions 2001-2016: loaded Oct 14, 2026, published Feb 20, 2026
  • Collisions with people killed or seriously injured (Toronto Police Service): loaded Nov 22, 2026, published Nov 21, 2026
  • Neighbourhood crime rates (Toronto Police Service): loaded Oct 14, 2026, published Feb 20, 2026
  • Cycling network: loaded Nov 22, 2026, published Nov 16, 2026
  • Development applications: loaded Nov 28, 2026, published Nov 28, 2026
  • Environmentally Significant Areas: loaded Oct 14, 2026, published Mar 16, 2026
  • Green spaces: loaded Nov 15, 2026, published Nov 10, 2026
  • Heritage register: loaded Oct 14, 2026, published Sep 1, 2026
  • Former heritage listings: loaded Oct 14, 2026, published Jul 3, 2025
  • Official Plan Amendment 720 heritage list: loaded Oct 14, 2026, published Sep 1, 2026
  • 3D Massing building footprints: loaded Oct 14, 2026, published Dec 2, 2025
  • By-law investigation addresses: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigation deficiencies: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigations: loaded Nov 28, 2026, published Nov 27, 2026
  • Major Transit Station Areas: loaded Oct 14, 2026, published Feb 3, 2026
  • Natural Heritage System: loaded Oct 14, 2026, published Mar 16, 2026
  • Neighbourhoods: loaded Oct 14, 2026, published Feb 20, 2026
  • Property boundaries: loaded Nov 27, 2026, published Nov 27, 2026
  • Active building permits: loaded Nov 28, 2026, published Nov 27, 2026
  • Cleared building permits: loaded Nov 28, 2026, published Nov 27, 2026
  • Cleared building permits 2000-2016: loaded Oct 14, 2026, published Jul 8, 2025
  • Preliminary zoning reviews: loaded Nov 28, 2026, published Nov 27, 2026
  • Ravine and natural feature protection: loaded Oct 14, 2026, published Jul 23, 2019
  • RentSafeTO evaluations: loaded Nov 28, 2026, published Nov 27, 2026
  • Multi-tenant house licences: loaded Nov 28, 2026, published Nov 27, 2026
  • Site and Area Specific Policies: loaded Oct 14, 2026, published Mar 16, 2026
  • School locations: loaded Oct 14, 2026, published May 27, 2026
  • Secondary Plans: loaded Oct 14, 2026, published Mar 16, 2026
  • Street trees: loaded Oct 14, 2026, published Jun 4, 2026
  • Short-term rental registrations: loaded Nov 28, 2026, published Nov 27, 2026
  • Traffic counts at intersections: loaded Nov 22, 2026, published Nov 21, 2026
  • TRCA regulation limit: loaded Oct 14, 2026, published Apr 29, 2026
  • TTC stops (GTFS): loaded Nov 8, 2026, published Nov 5, 2026
  • Zoning by-law: loaded Oct 14, 2026, published Feb 20, 2026
  • Lot coverage overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Height overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Parking zone overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Policy area overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Priority retail streets: loaded Oct 14, 2026, published Feb 20, 2026
  • Rooming house overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Zoning setbacks: loaded Oct 14, 2026, published Feb 20, 2026

Contains information licensed under the Open Government Licence – Toronto. TRCA regulation limit © TRCA.

Screening tool based on City of Toronto and TRCA open data. Not a zoning review or legal opinion. Site-specific exceptions, amendments not yet in the open data, minor variances and other by-laws can change the answer. Confirm with a Preliminary Project Review or Zoning Certificate from Toronto Building before buying or designing.

Flag an error

What is not right?

The problem

The records come from the City's open data; we check each flag against them. Your email is used only to answer this.