Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
Work or applications in progress
Good to knowRecent records on this lot: 22 138885 STE 11 SA (Site Plan Approval for a 36-storey mixed-use building containing 431 residential dwelli..., 2022); 20 192411 STE 11 OZ (Zoning By-law Amendment application for a 35-storey mixed-use building, containing 422..., 2020).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications14 development applications open within 300 m
Good to know14 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 37 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
14 records on file: more than at 100% of Toronto houses (median 0).
- By-law investigation26 150039 GRA 00 IRClosed
Graffiti
Apr 25, 2026 · 350 BLOOR ST W - Development application22 138885 STE 11 SAUnder Review
Site Plan Approval for a 36-storey mixed-use building containing 431 residential dwelling units (including 24 rental dwelling replacement units), retail at-grade and in the concourse levels and 2 levels of office space. The site includes a TTC entrance to Spadina Station, as well as 470 square metres of office space and two kiosk areas on the ground floor to be conveyed to the City to be used by Indigenous non-profit organization(s).
Apr 27, 2022 · 340 BLOOR ST W · City file - Development application20 192411 STE 11 OZCouncil Approved
Zoning By-law Amendment application for a 35-storey mixed-use building, containing 422 dwelling units and 8,200 square metres of non-residential gross floor area. The site includes a TTC entrance to Spadina Station, as well as 470 square metres of office space and two kiosk areas on the ground floor to be conveyed to the City to be used by Indigenous non-profit organization(s).
Sep 11, 2020 · 340 BLOOR ST W · City file - Zoning review11 203169 ZPRClosedMay 26, 2011 · 350 BLOOR ST W
- Zoning review09 173094 LTOClosedSep 25, 2009 · 350 BLOOR ST W
- Building permit04 186361Closed
Repair roof structure (fire damage) of 'Retail Store' (fruit stand in parking lot of 350 Floor St. W.)
Oct 29, 2004 · 350 BLOOR ST W - Building permit00 168046Closed
install on 2nd floor office: 1 k.s., 1 v.f.d. see 00-158497 edc.
Jul 4, 2000 · 350 BLOOR ST W - Building permit00 158497Closed
Install partitions on portion of the 2nd floor office.
Jun 26, 2000 · 350 BLOOR ST W
Show 6 older records
- Zoning review98 025822 LTOClosedMar 13, 1998 · 350 BLOOR ST W
- Zoning review95 025418 LTOClosedJul 21, 1995 · 350 BLOOR ST W
- Zoning review95 024885 LTOClosedMar 29, 1995 · 350 BLOOR ST W
- Zoning review95 024621 LTOClosedFeb 8, 1995 · 350 BLOOR ST W
- Zoning review90 029096 LTOClosedDec 14, 1990 · 350 BLOOR ST W
- Zoning review90 028320 LTOClosedApr 9, 1990 · 350 BLOOR ST W
Check before you build
Site-specific exception 900.11.10(760)
Needs a closer look23 site-specific rules apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
On 334-350 Bloor Street West and 2-6 Spadina Road, if the requirements of Schedule A of By-law 904-2022 are complied with, nothing in this by-law shall prevent the erection or use of a building , structure , addition or enlargement if it is in compliance with Regulations
- Rule B
to (W) below; (B) The provision of dwelling units is subject to the following: (i) a minimum of 15 percent of the total number of dwelling units must have two or more bedrooms; (ii) a minimum of 10 percent of the total number of dwelling units must have three or more bedrooms; (iii) any dwelling units with three or more bedrooms provided to satisfy (ii) above are not included in the provision required by (i) above; (iv) if the calculation of the number of required dwelling units with two or three bedrooms results in a number with a fraction, the number shall be rounded down to the nearest whole number; and (v) (i) to (iv) above shall not apply to rental replacement dwelling units as required by By-law 904-2022
- Rule C
Despite Regulations 40.5.40.10(1) and (2) the height of a building or structure is measured as the vertical distance between the Canadian Geodetic Datum elevation of 114.90 metres and the highest point of the building or structure
- Rule D
Despite Regulation 40.10.40.10(2), the permitted maximum height of a building or structure is the number in metres following the letters "HT" as shown on Diagram 6 of By-law 904-2022
- Rule E
Despite Regulation 40.5.40.10(3), (4), (5), (6), (7) and (8) and (D) above, the following elements of a building may project above the permitted maximum height in Diagram 6 of By-law 904-2022: (i) wind screens, parapets, guard rails, railings and dividers, pergolas, trellises, balustrades, screens, stairs, roof drainage, window washing equipment, chimneys, vents, lightning rods, light fixtures, and elements of a green roof , up to a maximum height of 6.5 metres; and (ii) the elements and structures noted in (K) below to a maximum of 3.5 metres
- Rule F
Despite Regulation 40.10.40.40(1), the maximum permitted gross floor area of all buildings and structures on the lot must not exceed 37,500 square metres, of which: (i) residential uses must not exceed 29,300 square metres; and (ii) non-residential uses must not exceed 8,200 square metres, of which a minimum of 3,716 square metres shall be for office uses
- Rule G
Despite Regulation 40.10.40.50(1), a building with 20 or more dwelling units must provide amenity space at a minimum rate of 3.9 square metres per unit, of which: (i) at least 2.0 square metres for each dwelling unit as indoor amenity space ; (ii) at least 40.0 square metres of outdoor amenity space is in a location adjoining or directly accessible to the indoor amenity space ; and (iii) no more than 25 percent of the outdoor component may be a green roof
- Rule H
Despite Regulations 40.10.40.70(2), 40.10.40.80(2), and 600.10.10(1)(A) to (D), the required minimum building setbacks and main wall separation distances for all buildings or structures are shown on Diagram 6 of By-law 904-2022
- Rule I
Despite Clause 40.10.40.60, Regulation 600.10.10(1)(E) to (F),
- Rule J
above, the following elements may encroach into the required minimum building setbacks and main wall separation distances as follows: (i) cornices, ornamental and architectural features, vertical screen elements at balconies, projecting panel system at exterior walls, parapets, art and landscape features, patios, decks, pillars, pergolas, trellises, terraces, eaves, window sills, planters, ventilation shafts, balustrades, railings, stairs, stair enclosures, doors, wheelchair ramps, fences, covered walkways, screens, site servicing features, awnings and canopies including support structures , window washing equipment, bicycle parking facilities and underground garage ramps and associated structures to a maximum of 3 metres; and (ii) structures , elements and enclosures permitted by (E) above to a maximum of 3 metres; (J) Despite Regulation 200.5.1.10(2), a maximum of 10 percent of the parking spaces required by By-law 904-2022 may be small car parking spaces with a minimum width of 2.4 metres, length of 5.4 metres and vertical clearance of 1.8 metres
- Rule K
Despite Regulation 200.5.10.1(1) and Table 200.5.10.1 and Regulations 200.10.1(1) and (2), parking spaces must be provided and maintained, in accordance with the following minimum: (i) a minimum of 0 residential occupant parking spaces for each dwelling unit ; (ii) a maximum of 0.65 residential occupant parking spaces for each dwelling unit ; (iii) a minimum of 2.0 parking spaces for residential visitors, plus an additional 0.01 parking spaces for each dwelling unit for residential visitors; (iv) a minimum of 0 parking spaces for non-residential uses; (v) parking spaces for non-residential uses and for residential visitors to a dwelling unit may be provided on a non-exclusive basis and may be located in a public parking area
- Rule L
Despite Regulation 200.5.10.1(1), "car-share parking spaces" may replace parking spaces otherwise required for residential occupants
- Rule M
For the purpose of this exception, "car-share" means the practice whereby a number of people share the use of one or more motor vehicles and such "car-share" motor vehicles are made available to at least the occupants of the building for short-term rental, including hourly rental
- Rule N
For the purpose of this exception, "car-share parking space" means a parking space exclusively reserved and signed for a vehicle used only for "car-share" purposes
- Rule O
Despite Regulations 200.15.1(1) to (4), accessible parking spaces must be provided and maintained in accordance with the following: (i) an accessible parking space must have the following minimum dimensions: (a) length of 5.6 metres; (b) width of 3.4 metres; and (c) vertical clearance of 2.1 metres; (ii) the entire length of an accessible parking space must be adjacent to a 1.5 metre wide accessible barrier free aisle or path; (iii) accessible parking spaces must be located within 16 metres of a barrier free entrance to the building or passenger elevator that provides access to the first storey of the building
- Rule P
Despite Regulation 200.15.10(1) a total of 7 accessible parking spaces shall be provided
- Rule Q
Despite Clauses 220.5.10.1 and 40.10.90.1(1) and (2), a minimum of two type "B" loading spaces , two type "C" loading spaces , and one type "G" loading space must be provided and maintained on the lot
- Rule R
Despite Regulation 230.5.1.10(4), a stacked bicycle parking space , shall have a minimum length of 1.7 metres a minimum width of 0.30 metres and a minimum vertical clearance of 1.2 metres
- Rule S
Despite Regulation 230.5.1.10(9), "long-term" bicycle parking spaces may be located anywhere within the building below grade and above grade up to and including the second storey
- Rule T
Despite Regulation 230.5.1.10(10), "short-term" bicycle parking spaces may be located in a stacked bicycle parking space
- Rule U
Despite Regulation 230.40.1.20(2), "short-term" bicycle parking spaces may be located anywhere in a building , including within a secure room, or on the lands outlined in heavy black lines on Diagram 1
- Rule V
None of the provisions of By-law 569-2013 shall apply to prevent a temporary sales office with a maximum height of 1 storey for the purposes of marketing, rental, leasing and/or sale of dwelling units and non-residential uses
- Rule W
Despite Regulation 40.10.40.40(5), a mezzanine shall not be considered as a limiting factor in the determination of the minimum height of the first storey .
Lot facts
- Area
- 504 m²
- Frontage
- 11 m
- Depth
- 47.1 m
- Street
- Bloor St W
- Corner lot
- No
- Public lane
- None
- Max height
- 18 m
- Max lot coverage
- —
- Site and Area Specific Policy 334. The Official Plan has a policy for this site or area that varies the general rules. Read it before relying on zoning alone. Source
- Major Transit Station Area: Spadina. The lot is inside the Spadina Major Transit Station Area approved by the Province (Site and Area Specific Policy 597). Source
- Downtown Plan Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Priority retail street: Bloor Street West. The lot is on a priority retail street. In this zone at least 60% of the ground floor along that street must hold retail, restaurants, offices or similar uses, with entrances within 5 m of the lot line and 60% of the ground floor wall in windows or doors. Source
- Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
- Zone CR 3.0 (c2.0; r2.5) SS2 (x760) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
- 1 City tree in front of this lot. The City's street tree inventory lists 1 tree at this address: elm (8 cm). Diameter is the trunk at breast height. Source
Around this lot
- Minor variances approved
- 92%24 of 26 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 2
- Multiplex permits
- 14
- Development applications
- 24
Within 300 m, last 10 years. 16 suite and multiplex permits: more than at 84% of Toronto houses (median 3). 26 variance decisions: more than at 58% of Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To permit the existing partially covered outdoor patio (abutting Borden Street), for the use of the eating establishment within the existing two-and-one-half-storey mixed-use building.
511 BLOOR ST W · Jul 16, 2026 · 353 m away - Minor varianceApproved
To alter the existing two-storey mixed-use building by constructing a rear three-storey addition with a ground floor one-car garage (abutting the laneway). The side (east) second and third storey portions of the rear addition will be partially cantilevered above the exterior passageway. The existing office space on the ground floor, as well as the two residential dwelling units on the second and third levels will be maintained.
108 HARBORD ST · Aug 13, 2025 · 434 m away - Minor varianceApproved
To alter the existing two-storey non-residential building by constructing front and rear ground floor additions. The ground floor will be converted into one restaurant use space. The existing office space, and dental office space, located on the second floor, will be maintained.
537 BLOOR ST W · Jun 11, 2025 · 436 m away - Minor varianceApproved
To permit a restaurant use (occupying the basement and ground levels of the existing three-storey mixed-use building). The existing residential dwelling unit (occupying the second and third levels) will be maintained and unaltered.
492 BLOOR ST W · Apr 9, 2025 · 430 m away - Minor varianceApproved
To alter the existing two-storey commercial building by increasing the permitted non-residential gross floor area for the restaurant use (through interior alterations).
648 SPADINA AVE · Dec 11, 2024 · 438 m away
Latest activity nearby
- Zoning review
Not Started
700 SPADINA AVE · Nov 24, 2026 · 253 m away - Building permit
Proposal for HVAC upgrade, replacement of hydronic heating system, ameliorated ventilation
482 HURON ST · Nov 10, 2026 · 254 m away - Building permit
Proposal for HVAC upgrade, replacement of hydronic heating system, ameliorated ventilation
480 HURON ST · Nov 10, 2026 · 249 m away - Building permit
HVAC upgrade, replacement of hydronic heating system, ameliorated ventilation
492 HURON ST · Nov 5, 2026 · 268 m away - Building permit
REPAIRS TO EXISITING REAR SECOND FLOOR DECK
23 MADISON AVE · Nov 5, 2026 · 222 m away - Building permit
Repairs to existing rear second floor deck
27 MADISON AVE · Nov 4, 2026 · 230 m away - Minor variancePending
To alter the development standards (as approved under Site Specific Zoning By-law 410-2024), for the 14-storey (51 m) residential building by increasing the height, gross floor area and modified setbacks. There will be a total of 64 residential dwelling units on this lot. A related Site Plan Control application (File Number 25 241286 STE 11 SA) is currently under review.
171 LOWTHER AVE · Nov 2, 2026 · 239 m away - Building permit
Proposal for interior and exterior sanitary line replacement clay to PVC with backwater valve.
324 BRUNSWICK AVE · Oct 30, 2026 · 270 m away - Building permit
Proposal for installation of roof edge railings, roof mounted stair, fixed ladder and ladder port at TTC's Spadina Stn -Main Entrance
7 SPADINA RD · Oct 28, 2026 · 104 m away - Building permit
Proposal for installation of roof edge railings and ladder port at TTC's Spadina Stn. - Walmer Entrance
9 WALMER RD · Oct 28, 2026 · 73 m away
Neighbourhood: Annex
About the area around the lot, not the lot itself.
- Nearest station
- Spadina Station4 min walk
- Nearest TTC stop
- Spadina Rd at Bloor St West1 min walk
- Nearest cycling route
- Bloor St WCycle Track, 1 min walk
- Nearest traffic count
- 10,256 vehicles in 8 hBloor St W / Sussex Mews, 30 m away, Mar 2, 2004
- Serious collisions within 500 m
- 42021–2026, killed or seriously injured: 0 fatal, 0 with pedestrians, 2 with cyclists
- Parks
- Matt Cohen Park2 min walk
- Paul Martel Park2 min walk
- Joseph Burr Tyrrell Park3 min walk
Schools within 1 km
- PAUL PENNA DOWNTOWN JEWISH DAY SCHOOL & MILES NADAL JEWISH COMMUNITY CENTRE Private 1 min walk
- UNIVERSITY OF TORONTO SCHOOLS Private 3 min walk
- TADDLE CREEK MONTESSORI SCHOOL Private 3 min walk
- HOWLETT ACADEMY SCHOOL Private 3 min walk
- JACKMAN INSTITUTE OF CHILD STUDY ELEMENTARY SCHOOL University 5 min walk
- SCHOOL OF CONTINUING STUDIES - U OF T, BLDG 103 University 6 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Annex | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $85,000 | $84,500 |
| Households that own their home | 41% | 54% |
| Population (2021) | 29,300 | 16,813 |
| Homes built in 1960 or before | 40% | 29% |
| Homes needing major repairs | 6% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Annex | City median |
|---|---|---|
| Assault | 1080.9 | 636.3 |
| Robbery | 80.5 | 69.5 |
| Homicide | 5.2 | 5.3 |
| Shootings | 5.2 | 10.5 |
| Auto theft | 116.9 | 192.6 |
| Theft over $5,000 | 114.3 | 46.1 |
| Break and enter | 387.1 | 172.8 |
| Theft from vehicles | 220.9 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.