Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
Heritage property: designated (Part IV)
Needs a closer lookOn the City's Heritage Register. Demolition and exterior changes need heritage review.
What it means. Renovations, additions and demolition can take longer, cost more or be refused.
How to confirm. Heritage Planning at the City confirms the status and what it covers. Details
City of Toronto Heritage Register10 development applications open within 300 m
Good to know10 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 46 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
32 records on file: more than at 100% of Toronto houses (median 0).
- Building permit26 125617Closed
1 WALL SIGN and 1PROJECTING SIGN**TIM HORTONS**
Apr 29, 2026 · 33 SHERBOURNE ST - Building permit25 130812Closed
Interior alterations of an existing suite - including Architectural, HVAC, plumbing, and electrical work. (Tim Hortons)
Apr 30, 2025 · 33 SHERBOURNE ST - Building permit23 187718Approved
To use Ontario Building Code Part 7 7.4.10.8.(2) for sizing of the sanitary drainage pipes instead of Table 7.4.10.8. at the building discharge to suit the servicing connections to the building. Table 7.4.10.8 of the OBC allows for 4500 fixture units to be drained in at 250mm pipe at 2.0% and the building load is ±6200 fixture units. The proposal is to use OBC 7.4.10.8.(2) for the sizing of the building discharge pipe only. In addition, the 250mm pipe complies with all municipal sanitary sewer sizing guidelines.The 250mm pipe complies with OBC 7.4.10.8.(2) as per the attached calculations. (see Appendix A)
Aug 11, 2023 · 33 SHERBOURNE ST - Building permit21 249006Closed
Drain - Proposal to construct a new 39 storey mixed used building, with 3 levels of underground parking garage, 2 levels of office/retail and 484 dwelling units. Included is the retention of heritage facades of 33 SHERBOURNE AND 176-178 STREET EAST. (180 FRON ST. E. Pending address). See also 21 224585 DEM, 21-237066-BA, 21-237094-BA and 19 215419 STE 13 SA.
Mar 16, 2023 · 33 SHERBOURNE ST - Building permit21 224612Closed
Revision 01. Installation of staging slab for future developmentProposal for a standalone shoring permit for Soil Remediation ONLYSee also 21 224585 DEM, 21-237066-BA, 21-237094-BA and 19 215419 STE 13 SA.
Oct 17, 2022 · 33 SHERBOURNE ST - Building permit21 196560Closed
To erect and display one non illuminated ground sign.***THE WHITEFILED RESIDENCES ON FRONT***
Mar 7, 2022 · 33 SHERBOURNE ST - Building permit21 237094Closed
Proposal for the retention of the existing facade of the retail building located on 33 Sherbourne Street. See also 21 224585 DEM and 19 215419 STE 13 SA.
Mar 3, 2022 · 33 SHERBOURNE ST - Building permit21 224585Closed
Proposal to demolish the gas station at convenience address 176 Front St E. See related 21-237094 at 33 Sherbourne St & 21-237066 at 178 Front St E.
Feb 14, 2022 · 33 SHERBOURNE ST
Show 24 older records
- Building permit22 109947Approved
Alternative Solution for providing 65mm diameter standpipe hose connections within the exit stairs (and as required on the floor areas for coverage purposes) in lieu of traditional fire hose cabinets (containing 38mm and 65mm diameter hose connections as well as 30m of fire hose) for the proposed mixed use building located at 176-178 Front St. E.
Feb 2, 2022 · 33 SHERBOURNE ST - Zoning review19 215419 PSPClosedDec 9, 2021 · 33 SHERBOURNE ST
- Development application21 215592 STE 13 CDClosed
Draft Plan of Condominium for 484 units.
Sep 21, 2021 · 176 FRONT ST E · City file - Zoning review19 124407 PRZClosedNov 14, 2020 · 33 SHERBOURNE ST
- Zoning review20 210861 ZPRClosedOct 26, 2020 · 33 SHERBOURNE ST
- Development application19 215419 STE 13 SAClosed
Site Plan Approval Application to permit a 39-storey building consisting of a 2-storey base building and a 39-storey tower with an overall height of 130 m (including mechanical penthouse). The application proposes 484 residential units.
Sep 3, 2019 · 33 SHERBOURNE ST · City file - Development application19 124407 STE 13 OZClosed
Revised Zoning By-law Amendment to permit a 38-storey building consisting of a 2-storey base building and a 35-storey tower with an overall height of 126.4 m (including mechanical penthouse). The application proposes 484 residential units and 1494q.m. of retail uses. A total of 98 vehicle parking spaces will be provided in 3 levels of underground parking.
Mar 12, 2019 · 176 FRONT ST E · City file - Building permit17 231683Closed
Tie-in to existing 4" Fire Line with a 4 x 2 mechanical tee, in order to provide a 2" water service to the new, doughnut shop. 176 FRONT ST ETalk to Peter P
Oct 3, 2017 · 33 SHERBOURNE ST - Building permit17 202190Closed
In conjunction with a two storey building on the premises, proposal to erect and display three wall signs, two of which are illuminated and the other non-illuminated, all displaying static copy, located on the first storey of the south and west elevations. The two illuminated wall signs are 0.61 metres vertically by 2.97 metres horizontally. The non-illuminated wall sign is 0.31 metres vertically by 2.91 metres horizontally.**TIM HORTONS**
Aug 23, 2017 · 33 SHERBOURNE ST - Building permit16 135547Closed
Revision 01: Revision for the addition of a washroom with a mop sink.Proposal for interior alterations to the ground floor retail space and 2nd floor office and storage space. Also for alterations to the exterior of the building - TS
Apr 19, 2017 · 33 SHERBOURNE ST - Building permit16 140515Closed
Interior alterations to Tim Hortons within the existing Esso Gas station
Jul 13, 2016 · 176 FRONT ST E - Zoning review16 123801 ZSVClosedMar 4, 2016 · 33 SHERBOURNE ST
- Building permit14 169026Cancelled
To modify an existing illuminated ground sign, original permit # 07-233202**Esso**
Jun 5, 2014 · 33 SHERBOURNE ST - Zoning review14 154621 ZSVCancelledMay 10, 2014 · 33 SHERBOURNE ST
- Zoning review07 223604 LTOClosedMay 29, 2007 · 33 SHERBOURNE ST
- Zoning review07 191092 ZPRClosedMay 3, 2007 · 33 SHERBOURNE ST
- Zoning review06 162104 PSPClosedJul 31, 2006 · 33 SHERBOURNE ST
- Zoning review04 100850 LTOClosedJan 7, 2004 · 33 SHERBOURNE ST
- Zoning review03 147011 LTOClosedJun 19, 2003 · 33 SHERBOURNE ST
- Building permit03 100018Closed
alter plans approved under B.P.#03-100018. Modified opening at the front of the building.
May 15, 2003 · 33 SHERBOURNE ST - Zoning review94 025508 LTOClosedOct 21, 1994 · 33 SHERBOURNE ST
- Building permit90 013766Closed
MAKE INTERIOR ALTERATIONS & BLOCK THE DUSTING WINDOWS ON THE SOUTH ELEVATION. /PS
Mar 5, 1990 · 33 SHERBOURNE ST - Zoning review88 030222 LTOClosedMar 17, 1988 · 176 FRONT ST E
- Zoning review83 026375 LTOClosedOct 28, 1983 · 176 FRONT ST E
Check before you build
Site-specific exception 900.12.10(29)
Needs a closer look22 site-specific rules apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
On 176 and 178 Front Street, and 33 and 35 Sherbourne Street, if the requirements in Section 6 and Schedule A of By-law 1094-2021 are complied with a building or structure may be constructed in compliance with regulations
- Rule B
to (V) below; (B) In addition to the uses permitted in regulation 50.10.20.10(1), public parking is also a permitted use
- Rule C
The permitted maximum gross floor area of all buildings and structures will be 30,500 square metres
- Rule D
The required minimum gross floor area for non-residential uses is 1,300 square metres
- Rule E
A minimum of twenty-five percent of the total number of dwelling units must contain two or more bedrooms, and a minimum of ten percent of the total number of dwelling units must contain three or more bedrooms
- Rule F
Despite regulation 50.5.40.10(1), the height of a building or structure is measured from the Canadian Geodetic Datum elevation of 79.47 metres to the highest point of a building or structure
- Rule G
Despite regulations 50.10.40.10(1), (2) and (4), the height of any building or structure may not exceed the height limit of the numbers following the symbol HT on Diagram 3 of By-law 1094-2021
- Rule H
Despite (G) above, and regulations 50.5.40.10(4), (5), (6), (7), and (8) the following elements or portion of any building or structure may project above the height indicated by the numbers following the symbol HT on Diagram 3 of By-law 1094-2021 as follows: (i) Elevator shafts, elevator overrun, elevator machine room, enclosed stairwells, and access ladders to 8.5 metres; (ii) Equipment used for the functional operation of the building , such as electrical, utility, mechanical and ventilation equipment; window washing equipment, structures used for the functional operation of the building , such as, maintenance equipment storage, mechanical rooms, chimneys, vents, and water supply facilities, and structures that enclose, screen or cover the elements listed above, by a maximum of 5.0 metres; (iii) Parapets, railings, architectural features ornamental elements, canopies, guard rails, mechanical and privacy screens, insulation and roof surface materials, building equipment and noise and wind mitigation structures, by a maximum of 2.5 metres; and (iv) Landscaping features and structures on the area labelled "HT 9.0 m" and "HT 31.5 m" on Diagram 3 used for outside or open air recreation, noise and wind mitigation structures , and planting and other landscaping structures and elements of a green roof, by a maximum of 3.0 metres.
- Rule I
Despite clauses 50.5.40.70, 50.10.40.80, and 50.10.40.70, the required minimum building setbacks and minimum distance between main walls are shown in metres on Diagram 3 of By-law 1094-2021
- Rule J
Despite (I) above, and regulation 5.10.40.70(1), and clauses 50.5.40.60 and 50.10.40.60, the following are permitted to encroach into the required minimum building setbacks , on Diagram 3 of By-law 1094-2021 as follows: (i) Ornamental elements, window projections, window washing equipment, mechanical and privacy screens, mechanical equipment, fences, trellises, railings, landscape features and awnings, to a maximum of 3.0 metres; (ii) Canopies to a maximum of 3.0 metres; (iii) Lighting fixtures, window sills, eaves, vents and stacks, to a maximum of 1.0 metre; (iv) Balconies and architectural features located on the 4th to 10th storeys to a maximum of 2.75 metres, and a maximum of 5.0 metres for the portion measured from the east side lot line by a length of 17.5 metres; (v) Balconies and architectural features located on the 11th storey and above , to a maximum of 2.75 metres; and (vi) Balconies and private terraces located on the 10th storey may encroach to the limit of the east side lot line .
- Rule K
Regulation 50.10.40.30(1), with respect to maximum building depth, does not apply
- Rule L
Despite clauses 50.10.40.50(1)(A), amenity space must be provided and maintained in accordance with the following: (i) A minimum rate of 2.0 square metres per dwelling unit is indoor amenity space ; (ii) A minimum rate of 1.4 square metres per dwelling unit is outdoor amenity space , of which a minimum of 40 square metres is to be provided in a location adjoining or directly accessible from an area that comprises indoor amenity space ; and (iii) The indoor amenity space may be provided in multipurpose rooms which are not contiguous, where a minimum of one multipurpose room is to have a kitchen and washroom and a minimum area of 100 square metres.
- Rule M
Despite regulations 200.5.10.1(1) and Table 200.5.10.1, parking spaces must be provided and maintained in accordance with the following: (i) A minimum of 0.15 parking spaces per dwelling unit for residents of the building ; and (ii) A minimum of 26 parking spaces must be provided as public parking within the building for the use of residential visitors, the non-residential uses of the building and the general public, with or without a fee, of which, a minimum of 2 parking spaces must be used for car share purposes.
- Rule N
Despite article 200.15.1(1) and regulation 200.15.10(1), a minimum of 4 accessible parking spaces must be provided and maintained in accordance with the following dimensions: (i) A minimum length of 5.6 metres; (ii) A minimum width of 3.4 metres; (iii) A minimum vertical clearance of 2.1 metres; and (iv) The entire length must be adjacent to a minimum 1.5 metres wide accessible barrier free aisle or path
- Rule O
Regulation 200.15.1 (4) with respect to location of accessible parking spaces , shall not apply
- Rule P
Regulation 200.10.1(1) with respect to marking drive aisles accessing visitor parking spaces , shall not apply
- Rule Q
Despite regulation 230.5.1.10(4), a bicycle parking space must comply with the following: (i) For a stacked bicycle parking space , a minimum length of 1.8 metres, a minimum width of 0.45 metres and a minimum vertical clearance of 1.0 metre; and (ii) For a bicycle parking space that is not a stacked bicycle parking space , a minimum length of 1.8 metres, a minimum width of 0.45 metres and a minimum vertical clearance of 1.9 metres.
- Rule R
Despite regulations 230.5.1.10(10) and 230.50.1.20, a "long-term" and "short-term" bicycle parking space may be located in a stacked bicycle parking space , which may be located within the building or outside, including within a secured room, enclosure or unenclosed space or any combination thereof, or bicycle locker
- Rule S
Despite regulations 220.5.10.1(2), (3), (4), (5), (6), (8), and article 220.20.1, a minimum of one Type "G" loading space and one Type "C" loading space must be provided and maintained
- Rule T
Clause 150.100.30.1 does not apply
- Rule U
Section 600.10 with respect to building setbacks for buildings in the downtown, does not apply
- Rule V
Section 600.20 with respect to Priority Retail Streets does not apply.
Lot facts
- Area
- 1,239 m²
- Frontage
- 33.1 m
- Depth
- 38.2 m
- Street
- Front St E
- Corner lot
- Yes, also on Sherbourne St38.2 m along it
- Public lane
- Abbey Lane, 39.6 m along it
- Max height
- 90 m
- Max lot coverage
- —
- Major Transit Station Area: Corktown. The lot is inside the Corktown Major Transit Station Area approved by the Province (Site and Area Specific Policy 764). Source
- King-Parliament Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Priority retail street: Front Street East, Sherbourne Street. The lot is on a priority retail street. In this zone at least 60% of the ground floor along that street must hold retail, restaurants, offices or similar uses, with entrances within 5 m of the lot line and 60% of the ground floor wall in windows or doors. Source
- Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
- Zone CRE (x29) (Commercial Residential Employment). Chapter 50, section 50.10 of the by-law. Source
Around this lot
- Minor variances approved
- 100%9 of 9 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 0
- Development applications
- 27
Within 300 m, last 10 years. 0 suite and multiplex permits: no more than at most Toronto houses (median 3). 9 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To legalize and to maintain the interior ground floor staircase, leading to the mezzanine, which was constructed without an authorized building permit. It should be noted that access to the mezzanine was only from the exterior of the building.
53 ONTARIO ST · Sep 23, 2026 · 327 m away - Minor varianceApproved
To alter the existing mixed-use building by designating 37 of the 43 non-residential parking spaces (located on the B-1 level) as a "Public Parking" use with the intent of permitting 20 of the 37 parking spaces to be leased as valet parking to a proposed hotel (municipally known as 197 King Street East) and the remaining 17 parking spaces to be rented to members of the public on a monthly basis.
120 FRONT ST E · May 10, 2023 · 198 m away - Minor varianceApproved
To alter the existing four-storey detached office building by constructing a partial fifth floor sunroom addition.
164 PRINCESS ST · Aug 17, 2022 · 142 m away - Minor varianceApproved
To convert the existing two-and-one-half-storey office building into a three-storey live-work unit by constructing a rear third storey addition.
63 BERKELEY ST · Dec 8, 2021 · 337 m away - Minor varianceApproved
To convert the existing two-storey townhouse into a two-storey office building by performing interior alterations.
133 GEORGE ST · Sep 15, 2021 · 407 m away
Latest activity nearby
- Building permit
Demolition and decommissioning of an existing pedestrian tunnel access structure, including removal of the existing stair and elevator access components and construction of a new reinforced concrete roof slab and associated site restoration
235 THE ESPLANADE · Nov 24, 2026 · 253 m away - Building permit
Building Alterations permit to accomodate the heritage retention and restoration of 234-236, 240 and 242 King Street East in line with the approved heritage conservation plan (related to permit No.21 248807 NB, 22 136259 DM)
250 KING ST E · Nov 23, 2026 · 117 m away - Building permit
Interior alterations to units 101 & 102 for building 204 King St E.
214 KING ST E · Nov 19, 2026 · 127 m away - Building permit
Full building demolition front retention and backfill to grade
242 KING ST E · Nov 19, 2026 · 113 m away - Building permit
Full building demolition front retention and backfill to grade
240 KING ST E · Nov 19, 2026 · 102 m away - Building permit
Full building demolition front retention and backfill to grade
234 KING ST E · Nov 19, 2026 · 105 m away - Building permit
Proposal for mag lock installations on lobby doors Level 2 to Level 8.
25 ONTARIO ST · Nov 17, 2026 · 231 m away - Zoning review
Cancelled
180 FRONT ST E · Nov 5, 2026 · 21 m away - Zoning review
Closed
178 FRONT ST E · Nov 5, 2026 · 21 m away - Zoning review
Cancelled
201 FREDERICK ST · Nov 3, 2026 · 181 m away
Neighbourhood: Moss Park
About the area around the lot, not the lot itself.
- Nearest station
- King Station14 min walk
- Nearest TTC stop
- Sherbourne St at Front St East1 min walk
- Nearest cycling route
- Sherbourne StCycle Track, 1 min walk
- Nearest traffic count
- 18,182 vehicles in 14 hFront St E / Sherbourne St / Lower Sherbourne St, 40 m away, Nov 19, 2025
- Serious collisions within 500 m
- 62021–2026, killed or seriously injured: 0 fatal, 4 with pedestrians, 1 with cyclists
- Parks
- David Crombie Park3 min walk
- Princess Street Park4 min walk
- Parliament Square Park5 min walk
Schools within 1 km
- GEORGE BROWN COLLEGE - ST JAMES CAMPUS College 3 min walk
- MARKET LANE JR & SR PUBLIC SCHOOL English Public 4 min walk
- ST MICHAEL CATHOLIC ELEMENTARY SCHOOL - BLDG 1 English Separate 6 min walk
- DOWNTOWN ALTERNATIVE SCHOOL English Public 6 min walk
- LIBERTY PREP SCHOOL Private 9 min walk
- VOICE INTEGRATIVE PRIVATE SCHOOL Private 10 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Moss Park | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $65,000 | $84,500 |
| Households that own their home | 35% | 54% |
| Population (2021) | 21,490 | 16,813 |
| Homes built in 1960 or before | 17% | 29% |
| Homes needing major repairs | 8% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Moss Park | City median |
|---|---|---|
| Assault | 2226.8 | 636.3 |
| Robbery | 166.6 | 69.5 |
| Homicide | 3.4 | 5.3 |
| Shootings | 3.4 | 10.5 |
| Auto theft | 81.6 | 192.6 |
| Theft over $5,000 | 64.6 | 46.1 |
| Break and enter | 350.2 | 172.8 |
| Theft from vehicles | 275.4 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.