HousePrecheckCheck an address

319 Spadina AveToronto · zoning, lot size and permit records

Also 321 Spadina Ave, 321 Spadina Ave, 323 Spadina Ave, 323 Spadina Ave, 325 Spadina Ave and 1 more

Commercial residential · CR 2.5 (c2.0; r2.0) SS2 (x351)20.9 × 42.9 m891 m²on Spadina Avecorner, also on St Andrew Stbacks onto Ln E Spadina N D Arcy

Not a home

A commercial or mixed-use building

4 different civic addresses share this parcel, in a commercial zone: shops, offices or a mixed-use building rather than one house. It is not a home for sale, so the house checks and the pre-offer report do not apply.

Looking at a house nearby? What this means for you

  • Shops, offices or a mixed buildingCustomers, deliveries and evening activity; errands within a short walk.
  • 1 development application open within 300 mNew buildings may go up around here in the next years. More change nearby than at 97% of Toronto houses.
  • Major Transit Station Area: St PatrickThe City plans more homes around the station: good for transit, and more building over time.
N10 m
20.9 m frontage42.9 m deep

Before you offer

From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.

  • 1 development application open within 300 m

    Good to know

    1 rezoning, site plan, subdivision or condominium application within 300 m, submitted in the last 10 years, is not closed yet. They are listed under Around this lot.

    What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.

    How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details

    City of Toronto, Development Applications

Not in these records

  • Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
  • Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.

History of this lot

21 records on file: more than at 100% of Toronto houses (median 0).

  • Building permit22 242116Closeddemolition

    Proposed demolition of existing 2-storey retail space. No existing dwelling units.

    Feb 13, 2023 · 325 SPADINA AVE
  • Building permit22 242112Closeddemolition

    Proposed demolition of existing 2-storey retail space. No existing dwelling units.

    Feb 13, 2023 · 323 SPADINA AVE
  • Building permit22 242105Closeddemolition

    Proposed demolition of existing 2-storey retail building. No existing dwelling units.

    Feb 13, 2023 · 321 SPADINA AVE
  • Development application20 214271 STE 11 SAClosed

    Proposal for a 13-storey mixed-use building with 219 residential dwelling units and a non-residential gross floor area of approximately 893 square metres.

    Nov 3, 2020 · 323 SPADINA AVE · City file
  • Development application19 195542 STE 11 OZClosed

    Proposed Rezoning for a new 13-storey mixed-use building containing 239 rental dwelling units and 893 m² of non-residential floor area. Total Floor area on the lot is 15,294 m².

    Jul 25, 2019 · 319 SPADINA AVE · City file
  • Building permit19 121654Closed

    Install 2" DCVA backflor preventer

    Apr 2, 2019 · 319 SPADINA AVE
  • Zoning review19 125073 ZZUClosed
    Mar 13, 2019 · 319 SPADINA AVE
  • Zoning review18 204864 LTOClosed
    Aug 6, 2018 · 321 SPADINA AVE
Show 13 older records
  • Zoning review18 105044 ZZUClosed
    Jan 15, 2018 · 321 SPADINA AVE
  • Building permit17 265498Cancelled

    Proposal to activate new HVAC application as per inspectors request related to 1994 HVAC permit (94 016353 - REF # 360965) in order close original deficiencies for retail space on ground floor.

    Nov 21, 2017 · 319 SPADINA AVE
  • Building permit17 146981Closed

    Revision 1: Revision to sprinkler headsProposal for interior alterations for Rol San Restaurant.

    Aug 10, 2017 · 323 SPADINA AVE
  • Building permit17 114498Closed

    To install new Fire Alarm Panel.

    Mar 2, 2017 · 323 SPADINA AVE
  • Zoning review15 133061 LTOClosed
    Mar 27, 2015 · 319 SPADINA AVE
  • Zoning review06 179624 LTOClosed
    Sep 28, 2006 · 319 SPADINA AVE
  • Zoning review06 176908 LTOClosed
    Sep 19, 2006 · 319 SPADINA AVE
  • Zoning review06 156946 LTOCancelled
    Jul 17, 2006 · 319 SPADINA AVE
  • Building permit06 122013Closed

    REVISION to relocate washroom - Proposed interior alteration to fit out from retail shop to new bakery take-out.

    Jun 15, 2006 · 319 SPADINA AVE
  • Building permit99 019547Closed

    MAKE INTERIOR ALTERATIONS TO EXPAND EXISTING RESTAURANT AND ALTER REAR ELEVATION FOR DOOR OPENING SS HEALTH DEPT APPROVAL REQUIRED

    Oct 4, 1999 · 323 SPADINA AVE
  • Zoning review91 026507 LTOClosed
    May 17, 1991 · 319 SPADINA AVE
  • Zoning review91 026088 LTOClosed
    Feb 7, 1991 · 323 SPADINA AVE
  • Zoning review89 030472 LTOClosed
    Nov 2, 1989 · 319 SPADINA AVE

Check before you build

  • Site-specific exception 900.11.10(351)

    Needs a closer look

    24 site-specific rules and 24 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.

    Zoning By-law 569-2013, Chapter 900
Exception 900.11.10(351)Applies

These parts of the exception apply to this lot's address.

  1. Rule A

    On 315-325 Spadina Avenue, if the requirements of Section 5 and Schedule A of By-law 917-2021 are complied with, none of the provisions of By-law 569-2013 apply to prevent the use or erection of a mixed use building that complies with Sections

  2. Rule B

    to (X); (B) The lot comprises the lands delineated by heavy lines on Diagram 1 attached to By-law 917-2021

  3. Rule C

    Despite Regulation 40.10.40.40(1), the gross floor area of the mixed use building must not exceed 16,400 square metres, of which a maximum of 1,100 square metres may be used for non-residential uses

  4. Rule D

    The permitted maximum number of dwelling units is 219

  5. Rule E

    Of the total number of dwelling units provided: (i) A minimum of 1 unit must be a four-bedroom dwelling units or larger; (ii) A minimum of 21 of the units must be three-bedroom dwelling units or larger; (iii) A minimum of 41 of the units must be two-bedroom dwelling units or larger; and (iv) A minimum of 39 of the units must be one-bedroom dwelling units or larger

  6. Rule F

    A minimum of seven (7) non-residential units must be provided at the ground level, which are subject to the following requirements: (i) A minimum of 6 must have frontage on Spadina Avenue; (ii) entrances must be directly accessible from Spadina Avenue or D'Arcy Street; (iii) units must not exceed a maximum permitted size of 150 square metres of gross floor area , with the exception of one unit which may have a maximum size of 250 square metres; and (iv) units must not exceed a maximum width of 8.5 metres along Spadina Avenue, with the exception of one unit which may have a maximum width of 12 metres

  7. Rule G

    Despite Regulation 40.5.40.10(1), the height of a building or structure is the vertical distance between the Canadian Geodetic Datum elevation of 98.56 metres and the highest point of the building or structure

  8. Rule H

    Despite Regulation 40.10.40.10(2), the permitted maximum height of a building or structure is the height in metres specified by the numbers following the symbol "HT" as shown on Diagram 3 of By-law 917-2021

  9. Rule I

    Despite Regulations 40.5.40.10(3) to (7) and (H) above, the following elements and structures may project beyond the maximum height in metres specified by the numbers following the symbol "HT" as shown on Diagram 3 of By-law 917-2021, equal to the sum of the maximum permitted height plus the maximum permitted height of the projection: (i) within the ‘Mechanical Zone’ as shown on Diagram 3, mechanical and electrical room elements and structures , elevator overrun, elevator lobby and vestibule, emergency generators, heating and cooling vents, covered stairs and uses that support the adjoining outdoor amenity space , including vestibule, storage areas and a washroom may project a maximum of 6.0 metres; (ii) structures on any roof used for maintenance or wind protection purposes may project a maximum of 3.0 metres; (iii) elements on the roof of the building or structure used for green roof technology and related roofing material may project a maximum of 2.0 metres; (iv) window washing equipment, safety anchors, lightning rods, safety railings, guard rails, railings, terraces, patios, landscape features, balustrades, bollards, ornamental or architectural features may project a maximum of 2.0 metres; (v) satellite dishes, antennae, acoustical barriers, cabanas and trellises may project a maximum of 4.0 metres; (vi) parapets, terrace guards/landscape planters and, vents, stacks, ladders, garbage chute vents and privacy fences between units may project a maximum of 2.0 metres; and (vii) screening for mechanical and electrical equipment may project a maximum of 4.0 metres

  10. Rule J

    Despite Regulations 5.10.40.70(1) and (4), 40.5.40.70 and 40.10.40.70(2), the required minimum building setbacks for a building or structure are shown on Diagram 3 of By-law 917-2021

  11. Rule K

    Despite Regulation 40.10.40.60 and (J) above, the following may encroach into the required minimum building setbacks on Diagram 3 of By-law 917-2021: (i) cornices, lighting fixtures, awnings, ornamental elements, commercial signage, parapets, trellises, eaves, window sills, guardrails, balustrades, railings, wheel chair ramps, stairs, stair enclosures, balconies, vents, underground garage ramps and their associated structures , fences, screens, landscaping, planter boxes, intake and exhaust vents may encroach up to a maximum of 1.5 metres; and (ii) wind mitigation features including canopies and awnings may encroach no more than 3.0 metres into the minimum building setbacks

  12. Rule L

    Despite Regulation 40.10.40.1(1), residential amenity space , mail room, and lobby are permitted on the same storey as non-residential uses

  13. Rule M

    Despite Regulation 40.10.40.50(1)(A) and (B), amenity space must be provided at a minimum rate of: (i) 2.0 square metres per dwelling unit of indoor amenity space ; and (ii) 2.0 square metres per dwelling unit of outdoor amenity space

  14. Rule N

    Despite Regulation 200.5.10.1, Table 200.5.10.1 and 200.15.10(1), parking spaces for the mixed use building shall be provided and maintained on the lot in accordance with the following: (i) a minimum of 34 parking spaces shall be provided, of which: (a) a minimum of 24 parking spaces shall be provided for residents; and (b) a minimum of 10 parking spaces are required to be provided and shared between visitors and non-residential uses

  15. Rule O

    Despite Regulation 200.5.1.10(2)(A) with respect to the required dimensions for parking spaces , a maximum of five (5) parking spaces are permitted with the following minimum dimensions: (i) Length – 4.88 metres; (ii) Width – 2.44 metres; and (iii) Vertical clearance – 2.0 metres

  16. Rule P

    Despite Regulation 200.5.1.10(2)(A)(iv) parking spaces may be obstructed on one or two sides and may have the following minimum dimensions: (i) Length – 5.6 metres; (ii) Width – 2.6 metres; and (iii) Vertical clearance – 2.0 metres

  17. Rule Q

    Despite Regulation 220.5.10.1(3), 1 loading space Type "G" shall be provided and maintained on the lot and may be shared between the residential and non-residential uses

  18. Rule R

    Despite Regulation 40.10.100.10(1)(C), more than one vehicle access is permitted

  19. Rule S

    Despite Regulation 40.10.90.10(1) and (2), a loading space is permitted in a rear yard abutting a Residential Zone category and may be accessed via the adjacent lane

  20. Rule T

    Despite Regulation 40.5.40.60(1), a canopy, awning or similar structure for wind mitigation purposes, with or without structural support, may encroach into a required minimum building setback that abuts a street , if no part of the canopy, awning or similar structure is located more than 8.0 metres above the elevation of the ground directly below it

  21. Rule U

    Despite Regulation 40.40.40.1(6), the entrance of a retail store may be located within 12.0 metres of the Residential Zone category

  22. Rule V

    Despite 40.10.50.10(1) and (3), no landscaping is required abutting the Residential Zone category

  23. Rule W

    Despite Regulations 230.5.1.10(7), change and shower facilities are not required

  24. Rule X

    Despite Regulations 230.5.10.1(1) and Table 230.5.10.1(1), bicycle parking spaces for the mixed-use building must be provided and maintained on the lot in accordance with the following: (i) a minimum of 0.9 "long term" bicycle parking spaces for each dwelling unit ; (ii) a minimum of 0.1 "short term" bicycle parking spaces for each dwelling unit ; (iii) a minimum of 3 plus 0.3 spaces "short term" bicycle parking spaces per 100 square metres of gross floor area for retail stores ; and (iv) a minimum of 0.2 "long term" bicycle parking spaces per 100 square metres of gross floor area for retail stores. Prevailing By-laws and Prevailing Sections:

  25. Older by-law A

    On 315-325 Spadina Avenue, if the requirements of Section 5 and Schedule A of By-law 917-2021 are complied with, none of the provisions of By-law 569-2013 apply to prevent the use or erection of a mixed use building that complies with Sections

  26. Older by-law B

    to (X); (B) The lot comprises the lands delineated by heavy lines on Diagram 1 attached to By-law 917-2021

  27. Older by-law C

    Despite Regulation 40.10.40.40(1), the gross floor area of the mixed use building must not exceed 16,400 square metres, of which a maximum of 1,100 square metres may be used for non-residential uses

  28. Older by-law D

    The permitted maximum number of dwelling units is 219

  29. Older by-law E

    Of the total number of dwelling units provided: (i) A minimum of 1 unit must be a four-bedroom dwelling units or larger; (ii) A minimum of 21 of the units must be three-bedroom dwelling units or larger; (iii) A minimum of 41 of the units must be two-bedroom dwelling units or larger; and (iv) A minimum of 39 of the units must be one-bedroom dwelling units or larger

  30. Older by-law F

    A minimum of seven (7) non-residential units must be provided at the ground level, which are subject to the following requirements: (i) A minimum of 6 must have frontage on Spadina Avenue; (ii) entrances must be directly accessible from Spadina Avenue or D'Arcy Street; (iii) units must not exceed a maximum permitted size of 150 square metres of gross floor area , with the exception of one unit which may have a maximum size of 250 square metres; and (iv) units must not exceed a maximum width of 8.5 metres along Spadina Avenue, with the exception of one unit which may have a maximum width of 12 metres

  31. Older by-law G

    Despite Regulation 40.5.40.10(1), the height of a building or structure is the vertical distance between the Canadian Geodetic Datum elevation of 98.56 metres and the highest point of the building or structure

  32. Older by-law H

    Despite Regulation 40.10.40.10(2), the permitted maximum height of a building or structure is the height in metres specified by the numbers following the symbol "HT" as shown on Diagram 3 of By-law 917-2021

  33. Older by-law I

    Despite Regulations 40.5.40.10(3) to (7) and (H) above, the following elements and structures may project beyond the maximum height in metres specified by the numbers following the symbol "HT" as shown on Diagram 3 of By-law 917-2021, equal to the sum of the maximum permitted height plus the maximum permitted height of the projection: (i) within the ‘Mechanical Zone’ as shown on Diagram 3, mechanical and electrical room elements and structures , elevator overrun, elevator lobby and vestibule, emergency generators, heating and cooling vents, covered stairs and uses that support the adjoining outdoor amenity space , including vestibule, storage areas and a washroom may project a maximum of 6.0 metres; (ii) structures on any roof used for maintenance or wind protection purposes may project a maximum of 3.0 metres; (iii) elements on the roof of the building or structure used for green roof technology and related roofing material may project a maximum of 2.0 metres; (iv) window washing equipment, safety anchors, lightning rods, safety railings, guard rails, railings, terraces, patios, landscape features, balustrades, bollards, ornamental or architectural features may project a maximum of 2.0 metres; (v) satellite dishes, antennae, acoustical barriers, cabanas and trellises may project a maximum of 4.0 metres; (vi) parapets, terrace guards/landscape planters and, vents, stacks, ladders, garbage chute vents and privacy fences between units may project a maximum of 2.0 metres; and (vii) screening for mechanical and electrical equipment may project a maximum of 4.0 metres

  34. Older by-law J

    Despite Regulations 5.10.40.70(1) and (4), 40.5.40.70 and 40.10.40.70(2), the required minimum building setbacks for a building or structure are shown on Diagram 3 of By-law 917-2021

  35. Older by-law K

    Despite Regulation 40.10.40.60 and (J) above, the following may encroach into the required minimum building setbacks on Diagram 3 of By-law 917-2021: (i) cornices, lighting fixtures, awnings, ornamental elements, commercial signage, parapets, trellises, eaves, window sills, guardrails, balustrades, railings, wheel chair ramps, stairs, stair enclosures, balconies, vents, underground garage ramps and their associated structures , fences, screens, landscaping, planter boxes, intake and exhaust vents may encroach up to a maximum of 1.5 metres; and (ii) wind mitigation features including canopies and awnings may encroach no more than 3.0 metres into the minimum building setbacks

  36. Older by-law L

    Despite Regulation 40.10.40.1(1), residential amenity space , mail room, and lobby are permitted on the same storey as non-residential uses

  37. Older by-law M

    Despite Regulation 40.10.40.50(1)(A) and (B), amenity space must be provided at a minimum rate of: (i) 2.0 square metres per dwelling unit of indoor amenity space ; and (ii) 2.0 square metres per dwelling unit of outdoor amenity space

  38. Older by-law N

    Despite Regulation 200.5.10.1, Table 200.5.10.1 and 200.15.10(1), parking spaces for the mixed use building shall be provided and maintained on the lot in accordance with the following: (i) a minimum of 34 parking spaces shall be provided, of which: (a) a minimum of 24 parking spaces shall be provided for residents; and (b) a minimum of 10 parking spaces are required to be provided and shared between visitors and non-residential uses

  39. Older by-law O

    Despite Regulation 200.5.1.10(2)(A) with respect to the required dimensions for parking spaces , a maximum of five (5) parking spaces are permitted with the following minimum dimensions: (i) Length – 4.88 metres; (ii) Width – 2.44 metres; and (iii) Vertical clearance – 2.0 metres

  40. Older by-law P

    Despite Regulation 200.5.1.10(2)(A)(iv) parking spaces may be obstructed on one or two sides and may have the following minimum dimensions: (i) Length – 5.6 metres; (ii) Width – 2.6 metres; and (iii) Vertical clearance – 2.0 metres

  41. Older by-law Q

    Despite Regulation 220.5.10.1(3), 1 loading space Type "G" shall be provided and maintained on the lot and may be shared between the residential and non-residential uses

  42. Older by-law R

    Despite Regulation 40.10.100.10(1)(C), more than one vehicle access is permitted

  43. Older by-law S

    Despite Regulation 40.10.90.10(1) and (2), a loading space is permitted in a rear yard abutting a Residential Zone category and may be accessed via the adjacent lane

  44. Older by-law T

    Despite Regulation 40.5.40.60(1), a canopy, awning or similar structure for wind mitigation purposes, with or without structural support, may encroach into a required minimum building setback that abuts a street , if no part of the canopy, awning or similar structure is located more than 8.0 metres above the elevation of the ground directly below it

  45. Older by-law U

    Despite Regulation 40.40.40.1(6), the entrance of a retail store may be located within 12.0 metres of the Residential Zone category

  46. Older by-law V

    Despite 40.10.50.10(1) and (3), no landscaping is required abutting the Residential Zone category

  47. Older by-law W

    Despite Regulations 230.5.1.10(7), change and shower facilities are not required

  48. Older by-law X

    Despite Regulations 230.5.10.1(1) and Table 230.5.10.1(1), bicycle parking spaces for the mixed-use building must be provided and maintained on the lot in accordance with the following: (i) a minimum of 0.9 "long term" bicycle parking spaces for each dwelling unit ; (ii) a minimum of 0.1 "short term" bicycle parking spaces for each dwelling unit ; (iii) a minimum of 3 plus 0.3 spaces "short term" bicycle parking spaces per 100 square metres of gross floor area for retail stores ; and (iv) a minimum of 0.2 "long term" bicycle parking spaces per 100 square metres of gross floor area for retail stores. Prevailing By-laws and Prevailing Sections:

By-law 569-2013, Chapter 900

Lot facts

Area
891 m²
Frontage
20.9 m
Depth
42.9 m
Street
Spadina Ave
Corner lot
Yes, also on St Andrew St42.9 m along it
Public lane
Ln E Spadina N D Arcy, 20.9 m along it
House footprint
Not showna new house or demolition permit since the City's 3D survey
Max height
18 m
Max lot coverage
—

House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.

  • Site and Area Specific Policy 202. The Official Plan has a policy for this site or area that varies the general rules. Read it before relying on zoning alone. Source
  • Major Transit Station Area: St Patrick. The lot is inside the St Patrick Major Transit Station Area approved by the Province (Site and Area Specific Policy 610). Source
  • Downtown Plan Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
  • Priority retail street: Spadina Avenue. The lot is on a priority retail street. In this zone at least 60% of the ground floor along that street must hold retail, restaurants, offices or similar uses, with entrances within 5 m of the lot line and 60% of the ground floor wall in windows or doors. Source
  • Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
  • Zone CR 2.5 (c2.0; r2.0) SS2 (x351) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
  • 2 City trees in front of this lot. The City's street tree inventory lists 2 trees at this address: ash, green (24 cm), elm (12 cm). Diameter is the trunk at breast height. Source

Around this lot

Minor variances approved
82%28 of 34 decisions
Garden suite permits
2
Laneway suite permits
9
Multiplex permits
17
Development applications
14

Within 300 m, last 10 years. 28 suite and multiplex permits: more than at 93% of Toronto houses (median 3). 34 variance decisions: more than at 68% of Toronto houses (median 19).

Recent variance decisions in the same zone

  • Minor varianceApproved

    To alter the existing three-storey mixed-use building by converting the office unit (occupying the rear portion of the ground level) into one additional residential dwelling unit. The exising retail unit (occupying the front portion of the ground level), and two residential units (occupying the second and third levels) will be maintained.

    281 COLLEGE ST · Feb 18, 2026 · 410 m away
  • Minor varianceApproved

    To permit a café and art studio use (with 20 seats) within the basement level of the existing three-storey mixed-use building. The ground floor restaurant, and eight residential dwelling units (located on the second and third floors) will be maintained and unaltered.

    198 AUGUSTA AVE · Nov 26, 2025 · 331 m away
  • Minor varianceApproved

    To alter the existing two-storey mixed-use building by converting two of the existing commercial units (municipally known as 265 and 267 Augusta Avenue) into eating establishments on the ground floor with storage within the basement. The existing residential dwelling units and eating establishment (municipally known as 269 Augusta Avenue) will be maintained and unaltered. There will be a total of three eating establishments on this lot.

    265 AUGUSTA AVE · Apr 30, 2025 · 358 m away
  • Minor varianceApproved

    To convert the existing one-storey non-residential building into a two-storey mixed-use building by constructing a complete second storey addition, and a rear two-storey addition. The existing eating establishment will be maintained on the ground level. There will be one residential dwelling unit on the second level (with access from the ground level).

    224 AUGUSTA AVE · Mar 5, 2025 · 356 m away
  • Minor varianceApproved

    To alter the development standards (as approved under Site Specific Zoning By-law 90-2020), for the existing two-storey building, by increasing the eating establishment area.

    204 AUGUSTA AVE · Jan 29, 2025 · 337 m away

Latest activity nearby

  • Consent (lot split)Pending

    To obtain consent for the technical severance of the property for the purpose of re-establishing two lots which merged on title.

    130 D'ARCY ST · Dec 9, 2026 · 68 m away
  • Zoning review

    Application Acceptable

    405 DUNDAS ST W · Nov 26, 2026 · 297 m away
  • Building permit

    2 wall signs + 1 projecting sign**CHERUBIN**

    315 SPADINA AVE · Nov 25, 2026 · 25 m away
  • Building permit

    Instalation of a BFP on the main water line after meter

    58 KENSINGTON AVE · Nov 24, 2026 · 217 m away
  • Minor variancePending

    Accepted

    77 BALDWIN ST · Nov 17, 2026 · 221 m away
  • Building permitsecondary suite

    REV 01: REVISION TO LAYOUT as bubbledProposal for interior alterations to relocate kitchens from the Basement and 2nd Floor to the Ground Floor and 3rd Floor, and to add additional plumbing fixtures.

    5 KENSINGTON AVE · Nov 13, 2026 · 225 m away
  • Building permit

    Interior alterations, HVAC & plumbing. Conversion of existing Heydon Park Secondary School to elementary school.

    70 D'ARCY ST · Nov 10, 2026 · 293 m away
  • Building permit

    HVAC permit for as built heating and cooling system, relocation of existing heat pump.

    160 BALDWIN ST · Nov 5, 2026 · 173 m away
  • Building permit

    Proposal for interior alterations for a wellness centre in basement

    434 DUNDAS ST W · Oct 30, 2026 · 220 m away
  • Building permitsecondary suite

    Proposed interior alterations, 3rd floor addition, and basement walk-out in front yard.

    77 BALDWIN ST · Oct 28, 2026 · 221 m away

Neighbourhood: Kensington-Chinatown

About the area around the lot, not the lot itself.

Nearest station
St Patrick Station14 min walk
Nearest TTC stop
Spadina Ave at Dundas St West North Side2 min walk
Nearest cycling route
Beverley StBike Lane, 5 min walk
Nearest traffic count
7,951 vehicles in 8 hSpadina Ave / St Andrew St, 40 m away, May 10, 2023
Serious collisions within 500 m
102021–2026, killed or seriously injured: 1 fatal, 5 with pedestrians, 4 with cyclists
Parks
Glasgow Street Parkette4 min walk
Julius Deutsch Park4 min walk
Bellevue Square Park5 min walk

Schools within 1 km

  • BEVERLEY & SUBWAY ACADEMY TWO English Public 4 min walk
  • HEYDON PARK SECONDARY SCHOOL English Public 5 min walk
  • CORNERSTONE PREPARATORY SCHOOL - MAIN CAMPUS Private 5 min walk
  • BRAEMAR COLLEGE PRIVATE SECONDARY SCHOOL Private 7 min walk
  • RYERSON COMMUNITY SCHOOL & DOWNTOWN VOCAL MUSIC ACADEMY English Public 8 min walk
  • WESTSIDE MONTESSORI ELEMENTARY SCHOOL Private 8 min walk

Being near a school does not mean the lot is in its catchment; check with the board.

2021 Census

FigureKensington-ChinatownMedian neighbourhood
Median household income (2020)$62,000$84,500
Households that own their home32%54%
Population (2021)18,12016,813
Homes built in 1960 or before26%29%
Homes needing major repairs8%7%

Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.

Police-reported crime, 2025

Per 100,000 peopleKensington-ChinatownCity median
Assault2017.5636.3
Robbery19369.5
Shootings21.910.5
Auto theft118.4192.6
Theft over $5,000219.346.1
Break and enter443172.8
Theft from vehicles850.8188.1

Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.

Something here not right?

Sources

  • Building permits on this lot since 2000: Permits issued or applied for since about 2000, with status.
  • Committee of Adjustment files since 2001: Minor variances and consents (lot splits) on this lot and nearby, with decisions.
  • Development applications: Rezoning, site plan, subdivision and condominium applications.
  • Preliminary zoning reviews: Zoning reviews requested before a permit or variance application.
  • Zoning and overlays: Zoning By-law 569-2013 zone, height, coverage, policy area, parking, rooming house, priority retail street and downtown setback overlays.
  • Lot boundary, street and lane: Lot polygon, its addresses, the street it fronts, corner and public lane contact, with frontage and depth measured from the boundary; City of Toronto land in City use, which is not a home.
  • House and yards: Footprint and roof height of the house and other buildings, and the yard behind the house, from the City's 3D Massing (updated yearly, illustrative).
  • City trees in front of the lot: City-owned trees on the street allowance at this address, with species and trunk diameter. Private trees on the lot are not in open data.
  • Heritage: Heritage Register (listed and designated properties), Official Plan Amendment 720 properties and properties removed from the Register under the 2022 two-year limit.
  • TRCA regulated area: Valleys, floodplains, shorelines and wetlands regulated by the Toronto and Region Conservation Authority.
  • Ravines and natural features: Ravine and Natural Feature Protection area (Chapter 658, map last published 2019), Natural Heritage System and Environmentally Significant Areas.
  • Official Plan policies: Site and Area Specific Policies, Secondary Plans and Major Transit Station Areas covering the lot.
  • Rooming houses, short-term rentals and rental buildings: Multi-tenant house licences, short-term rental registrations and RentSafeTO evaluations at this address.
  • Neighbourhood context: Neighbourhood, 2021 Census figures, police-reported crime rates, schools, parks, TTC stops, cycling routes, serious collisions and traffic counts nearby. Area context only, not a finding about the lot.
  • Orders and by-law investigations: Outstanding Toronto Building orders, and by-law investigations open now or closed in the last two years. Fire and Public Health orders and older closed files are not published.
  • Address points: loaded Nov 22, 2026, published Nov 20, 2026
  • Toronto Building orders: loaded Nov 28, 2026, published Nov 27, 2026
  • Neighbourhood Profiles, 2021 Census: loaded Oct 14, 2026, published Oct 6, 2023
  • Street centrelines: loaded Nov 22, 2026, published Nov 20, 2026
  • City-owned land: loaded Nov 22, 2026, published Nov 16, 2026
  • Committee of Adjustment open applications: loaded Nov 28, 2026, published Nov 27, 2026
  • Committee of Adjustment decisions: loaded Nov 28, 2026, published Nov 27, 2026
  • Committee of Adjustment decisions 2001-2016: loaded Oct 14, 2026, published Feb 20, 2026
  • Collisions with people killed or seriously injured (Toronto Police Service): loaded Nov 22, 2026, published Nov 21, 2026
  • Neighbourhood crime rates (Toronto Police Service): loaded Oct 14, 2026, published Feb 20, 2026
  • Cycling network: loaded Nov 22, 2026, published Nov 16, 2026
  • Development applications: loaded Nov 28, 2026, published Nov 28, 2026
  • Environmentally Significant Areas: loaded Oct 14, 2026, published Mar 16, 2026
  • Green spaces: loaded Nov 15, 2026, published Nov 10, 2026
  • Heritage register: loaded Oct 14, 2026, published Sep 1, 2026
  • Former heritage listings: loaded Oct 14, 2026, published Jul 3, 2025
  • Official Plan Amendment 720 heritage list: loaded Oct 14, 2026, published Sep 1, 2026
  • 3D Massing building footprints: loaded Oct 14, 2026, published Dec 2, 2025
  • By-law investigation addresses: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigation deficiencies: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigations: loaded Nov 28, 2026, published Nov 27, 2026
  • Major Transit Station Areas: loaded Oct 14, 2026, published Feb 3, 2026
  • Natural Heritage System: loaded Oct 14, 2026, published Mar 16, 2026
  • Neighbourhoods: loaded Oct 14, 2026, published Feb 20, 2026
  • Property boundaries: loaded Nov 27, 2026, published Nov 27, 2026
  • Active building permits: loaded Nov 28, 2026, published Nov 27, 2026
  • Cleared building permits: loaded Nov 28, 2026, published Nov 27, 2026
  • Cleared building permits 2000-2016: loaded Oct 14, 2026, published Jul 8, 2025
  • Preliminary zoning reviews: loaded Nov 28, 2026, published Nov 27, 2026
  • Ravine and natural feature protection: loaded Oct 14, 2026, published Jul 23, 2019
  • RentSafeTO evaluations: loaded Nov 28, 2026, published Nov 27, 2026
  • Multi-tenant house licences: loaded Nov 28, 2026, published Nov 27, 2026
  • Site and Area Specific Policies: loaded Oct 14, 2026, published Mar 16, 2026
  • School locations: loaded Oct 14, 2026, published May 27, 2026
  • Secondary Plans: loaded Oct 14, 2026, published Mar 16, 2026
  • Street trees: loaded Oct 14, 2026, published Jun 4, 2026
  • Short-term rental registrations: loaded Nov 28, 2026, published Nov 27, 2026
  • Traffic counts at intersections: loaded Nov 22, 2026, published Nov 21, 2026
  • TRCA regulation limit: loaded Oct 14, 2026, published Apr 29, 2026
  • TTC stops (GTFS): loaded Nov 8, 2026, published Nov 5, 2026
  • Zoning by-law: loaded Oct 14, 2026, published Feb 20, 2026
  • Lot coverage overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Height overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Parking zone overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Policy area overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Priority retail streets: loaded Oct 14, 2026, published Feb 20, 2026
  • Rooming house overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Zoning setbacks: loaded Oct 14, 2026, published Feb 20, 2026

Contains information licensed under the Open Government Licence – Toronto. TRCA regulation limit © TRCA.

Screening tool based on City of Toronto and TRCA open data. Not a zoning review or legal opinion. Site-specific exceptions, amendments not yet in the open data, minor variances and other by-laws can change the answer. Confirm with a Preliminary Project Review or Zoning Certificate from Toronto Building before buying or designing.

Flag an error

What is not right?

The problem

The records come from the City's open data; we check each flag against them. Your email is used only to answer this.