HousePrecheckCheck an address

315 Front St WToronto · zoning, lot size and permit records

Also 299 Front St W, 325 Front St W

90.5 × 200.3 m16,349 m²on Blue Jays Waycorner, also on Front St W

Not a home

Isabella Valancy Crawford Park

The City of Toronto's real estate inventory lists Isabella Valancy Crawford Park here, on City land in City use. It is not a home for sale, so the house checks and the pre-offer report do not apply.

Looking at a house nearby? What this means for you

  • Green space next doorShade, play and walks; busy parks also bring events and evening noise.
  • Permits or applications open on this parcelRecent records on this lot: 25 178538 (Interior alterations, 2025); 25 145118 (Proposal to construct partitions, construct a ramp and create new office space in a vac..., 2025); 25 158283 STE 10 SA (Site Plan Approval Application for Phase 1 of a three phase development at 315-325 Fron..., 2025); and 1 more. Larger work can mean noise and trucks next door; read what each one is for.
  • 10 development applications open within 300 m, up to 71 storeysNew buildings may go up around here in the next years. More change nearby than at 98% of Toronto houses.
N50 m
90.5 m frontage200.3 m deep

Before you offer

From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.

  • Building permit open since 2021

    Needs a closer look

    Still open in the City's records: 21 245875 (Interior demolition existing security desk make good existing surface, 2021, status Permit Issued).

    What it means. An open permit can mean work that was never finished or never passed final inspection. After closing, finishing it or closing the file can fall to you.

    How to confirm. Ask the seller for the final inspection records. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details

    City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016)
  • Work or applications in progress

    Good to know

    Recent records on this lot: 25 178538 (Interior alterations, 2025); 25 145118 (Proposal to construct partitions, construct a ramp and create new office space in a vac..., 2025); 25 158283 STE 10 SA (Site Plan Approval Application for Phase 1 of a three phase development at 315-325 Fron..., 2025); and 1 more.

    What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.

    How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details

    City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications
  • 7 Committee of Adjustment files on this lot

    Good to know

    3 approved. B0079/20TEY (To obtain consent to sever a portion of land for the purpose of lot additions with a lo..., 2020); B0078/20TEY (To obtain consent to sever a portion of land for the purpose of lot additions with a lo..., 2020); B0077/20TEY (To obtain consent to sever a portion of land for the purpose of a lot addition with a l..., 2020); and 4 more.

    What it means. Approved variances and consents stay with the property, including any conditions in the decision. They allow what was approved, not more.

    How to confirm. Decisions are in the Application Information Centre; older files are available from the Committee of Adjustment office. Details

    City of Toronto, Committee of Adjustment applications (2001 onwards)
  • 10 development applications open within 300 m

    Good to know

    10 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 71 storeys. They are listed under Around this lot.

    What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.

    How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details

    City of Toronto, Development Applications

Not in these records

  • Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
  • Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.

History of this lot

130 records on file: more than at 100% of Toronto houses (median 0).

  • Zoning review25 158283 PSPClosed
    Sep 4, 2025 · 315 FRONT ST W
  • Zoning review24 250793 PRZClosed
    Aug 14, 2025 · 315 FRONT ST W
  • Zoning review25 203596 ZPRClosed
    Jul 31, 2025 · 315 FRONT ST W
  • Building permit25 178538Inspection

    Interior alterations

    Jun 19, 2025 · 325 FRONT ST W
  • Building permit25 145118Permit Issued

    Proposal to construct partitions, construct a ramp and create new office space in a vacant space..

    May 22, 2025 · 325 FRONT ST W
  • Development application25 158283 STE 10 SAUnder Review

    Site Plan Approval Application for Phase 1 of a three phase development at 315-325 Front Street West. The Phase 1 site plan includes two primarily residential towers (50 storeys), containing 74,000 square metres of residentail floor area and 830 square metres of retail floor area. A total of 905 residential units are proposed including 32 affordable rental housing units, A childcare centre is also proposed.

    May 12, 2025 · 325 FRONT ST W · City file
  • Development application24 250793 STE 10 OZCouncil Approved

    Zoning By-law Amendment to previously approved ZBA 19 204347 STE 10 OZ for three residential towers (50 and 71 storeys) and one office tower (60 storeys). The application also includes a public childcare facility, affordable rental housing units, and 600 m2 of POPS fronting onto Front Street West.

    Dec 16, 2024 · 315 FRONT ST W · City file
  • Building permit24 103290Closed

    proposed replacement of fire alarm control panel and devices

    Feb 21, 2024 · 325 FRONT ST W
Show 122 older records
  • Building permit23 233245Closed

    Plumbing - Installation of new cooler and freezer on existing basement floor stockroom area.

    Dec 18, 2023 · 325 FRONT ST W
  • Building permit23 135174Closed

    MINOR INTERIOR ALTERATIONS WITH MECHANICAL AND ELECTRICAL WORK TO SUIT NEW LAYOUT.

    Apr 28, 2023 · 325 FRONT ST W
  • Building permit22 236215Closed

    To erect and display one non-illuminated wall sign**Spaces**

    Dec 19, 2022 · 315 FRONT ST W
  • Zoning review19 204347 POZClosed
    Jan 6, 2022 · 325 FRONT ST W
  • Zoning review19 204382 PRZClosed
    Jan 6, 2022 · 325 FRONT ST W
  • Building permit21 245875Permit Issued

    Interior demolition existing security desk make good existing surface

    Dec 15, 2021 · 315 FRONT ST W
  • Consent (lot split)B0079/20TEYApproved

    To obtain consent to sever a portion of land for the purpose of lot additions with a lower elevation starting at 88.7 m above mean sea level.

    Dec 21, 2020 · 325 FRONT ST W
  • Consent (lot split)B0078/20TEYApproved

    To obtain consent to sever a portion of land for the purpose of lot additions with a lower elevation starting at 88.3 m above mean sea level (air parcel).

    Dec 21, 2020 · 325 FRONT ST W
  • Consent (lot split)B0077/20TEYApproved

    To obtain consent to sever a portion of land for the purpose of a lot addition with a lower elevation starting at 87.5 m above mean sea level (air parcel).

    Dec 21, 2020 · 325 FRONT ST W
  • Consent (lot split)B0036/20TEYWithdrawn
    Jun 2, 2020 · 325 FRONT ST W
  • Consent (lot split)B0007/20TEYWithdrawn
    Jan 23, 2020 · 325 FRONT ST W
  • Consent (lot split)B0006/20TEYWithdrawn
    Jan 23, 2020 · 325 FRONT ST W
  • Consent (lot split)SYS 4699935Pending

    Proposal for a consent to sever the TTR owned lands between Blue Jays Way and Lower Simcoe from the reaminerder of the Railway Corridor.

    Dec 23, 2019 · 325 FRONT ST W
  • Building permit19 256602Closed

    Proposed interior alteration to remove part of wall for installation of a PC250 glazed wall insert

    Dec 16, 2019 · 315 FRONT ST W
  • Building permit19 183588Closed

    REV #1-REVISE LAYOUTProposal for interior alterations to ground floor suite in existing office building

    Nov 4, 2019 · 325 FRONT ST W
  • Development application19 204347 STE 10 OZClosed

    Official Plan and Zoning By-law Amendment application to permit a mixed-use development with office, retail, residential and daycare uses in four buildings, including two office buildings and two residential buildings, as well as to permit park and open space uses over the rail corridor between Blue Jays Way and John Street. The office buildings are proposed to have heights of 50 storeys (262 metres) and 60 storeys (303 metres). The residential buildings are proposed to have heights of 50 storeys (186 metres) and 52 storeys (192 metres). 832 rental dwelling units of which 32 are proposed as affordable rental units. 273,592 square metres of non-residential floor area is proposed. A four-level underground garage and 688 vehicle and 1,943 bicycle parking spaces are proposed.

    Aug 12, 2019 · 325 FRONT ST W · City file
  • Building permit18 157325Closed

    Rev 01: Revision for modifications on the fifth floor involving demolishing three rooms, expansion of one room, and new high density filing areaProposal for interior alterations to existing office space to floors 1, 2, 9, 10, 11, 12, 13, 14, 15, 16, 17. Tenant is Infrastructure Ontario.

    Feb 13, 2019 · 325 FRONT ST W
  • Building permit19 105261Closed

    315 Front Street West - 2nd Floor Mail Room To install maglock on double mail room door with card reader in and out.This Double door is a exterior door used for mail room delivery.

    Jan 21, 2019 · 315 FRONT ST W
  • Building permit18 267889Cancelled

    Proposal to install one maglock on the second floor.

    Dec 12, 2018 · 315 FRONT ST W
  • Building permit18 186850Closed

    Plumbing - Interior alterations to existing office space on the Lower Level. Tenant - "Kindred".

    Aug 2, 2018 · 325 FRONT ST W
  • Building permit18 176231Closed

    Proposal for interior alterations to 2nd floor of existing office building.

    Jul 20, 2018 · 325 FRONT ST W
  • Building permit17 266414Closed

    Revision 01 - updated sprinkler systemINTERIOR TENANT ALTERATIONS FOR LEVELS 01 TO 17 INCLUDINGCONSTRUCTION OF NON-LOADBEARING PARTITIONS, RE-ALIGNMENT, ANDRE-DISTRIBUTION OF ELECTRICAL, MECHANICAL, AND LIFE SAFETYSYSTEMS.

    May 9, 2018 · 325 FRONT ST W
  • Building permit18 136019Closed

    Proposed electromagnetic lock installation on floors 3, 7, 11, and 15.

    Apr 24, 2018 · 315 FRONT ST W
  • Building permit17 209324Closed

    Rev 01: Interior layout changesOrig: New demising wall and alteration to the PUBLIC CORRIDOR on the 3rd floor -existing multiple tenant storey

    Apr 24, 2018 · 325 FRONT ST W
  • Building permit18 112062Closed

    Proposal for interior alterations to existing office building. Scope of work is for alterations to cafeteria / kitchen on first level below grade off of Front St W.

    Feb 26, 2018 · 325 FRONT ST W
  • Building permit17 249772Closed

    Proposal for interior alterations for partial 3rd floor unit 301.

    Dec 18, 2017 · 325 FRONT ST W
  • Building permit17 183586Cancelled

    Proposed demising corridor on 2nd floor in existing office building. *OXFORD PROPERTIES GROUP*

    Jul 20, 2017 · 325 FRONT ST W
  • Building permit17 119805Closed

    Proposal for interior alterations to existing office space on the 3rd floor - "Ontario Centres of Excellence"

    Mar 23, 2017 · 325 FRONT ST W
  • Building permit17 124782Closed

    New demising corridor on the 3rd floor of the existing office building

    Mar 20, 2017 · 315 FRONT ST W
  • Building permit17 124831Closed

    Demolition of existing building security and access gates serving the floor and B1 level of the building

    Mar 10, 2017 · 315 FRONT ST W
  • Building permit16 257843Closed

    Proposal to install 5 maglocks on the 4th floor of the existing office building.

    Jan 6, 2017 · 325 FRONT ST W
  • Building permit16 236157Closed

    Proposed interior alterations to the existing office space on the 4th floor. tenant name " One Eleven"

    Nov 24, 2016 · 325 FRONT ST W
  • Building permit16 140447Closed

    Proposal for interior demolition - back to base build - ground-17th floors of existing office building.No other work included on this permit.

    May 20, 2016 · 325 FRONT ST W
  • Building permit16 130545Closed

    Proposal to install 1 maglock in the elevator lobby on the 3rd floor of an existing office building. Convenience address is 315 Front St W.

    Apr 19, 2016 · 325 FRONT ST W
  • Building permit16 111739Closed

    Proposal for interior alterations to unit 300 in existing office - "Oxford Properties"

    Feb 10, 2016 · 325 FRONT ST W
  • Zoning review15 222801 LPRClosed
    Sep 15, 2015 · 325 FRONT ST W
  • Zoning review15 182226 LPRClosed
    Jun 29, 2015 · 325 FRONT ST W
  • Building permit13 125256Closed

    Proposal to add an electromagnetic power supply and direct 2 electromagnetic locks to it on existing 2nd floor of existing office building.

    Mar 28, 2013 · 325 FRONT ST W
  • Building permit12 208446Closed

    This is for interior alterations to the 2nd floor for a new office layout for "SYMCOR". This will include HVAC.

    Jul 25, 2012 · 325 FRONT ST W
  • Zoning review12 181951 LPRClosed
    May 29, 2012 · 325 FRONT ST W
  • Building permit12 146637Closed

    Proposal for interior alterations to level 2 (below grade) to create a new wall opening in existing multi use commercial building.

    Apr 3, 2012 · 325 FRONT ST W
  • Zoning review12 134877 LPRClosed
    Mar 9, 2012 · 325 FRONT ST W
  • Building permit12 102015Closed

    Interior alterations to 5th floor to replace UPS (uninterupptable power supply) system and CRAC (compueter room air conditioner) unit equipment.

    Feb 2, 2012 · 325 FRONT ST W
  • Building permit11 246063Closed

    Minor interior alterations to existing washroom areas on 3rd and 4th floors.

    Aug 17, 2011 · 325 FRONT ST W
  • Building permit11 219340Closed

    This is for a new water softener within the mechanical penthouse.

    Jul 27, 2011 · 325 FRONT ST W
  • Building permit11 219321Closed

    This is for the replacement of the existing boiler within the mechanical penthouse.

    Jul 27, 2011 · 325 FRONT ST W
  • Building permit10 260293Closed

    permit for interior alterations to existing office space - floor 4 - RBC - CONVENIECNE ADDRESS 315 FRONT ST

    Sep 22, 2010 · 325 FRONT ST W
  • Building permit10 110350Closed

    Proposal for relocation of diffusers in existing cafeteria in RBC building. No construction, change of use, or plumbing alterations.

    Mar 26, 2010 · 325 FRONT ST W
  • Building permit10 109168Closed

    permit to install 2 maglocks on 4th floor of eixsting office space - interior alterations permit is 09 177831 BLD.

    Feb 17, 2010 · 325 FRONT ST W
  • Building permit10 101829Closed

    Permit for 4" backflow valve in existing office building - Backflow for 315 Front

    Feb 3, 2010 · 325 FRONT ST W
  • Building permit09 193747Cancelled

    FS - Sprinkler Shop Drawing - Proposal for interior alterations to 4th floor office space. (See revision cloud)(see permit 09-106268, 09-177813, 09-184622)

    Dec 11, 2009 · 325 FRONT ST W
  • Building permit09 194579Closed

    Proposal for interior alterations to existing 3rd floor office space. Tenant is "RBC Financial Group". Convenience address is 315 Front St. W.

    Dec 10, 2009 · 325 FRONT ST W
  • Building permit09 184622Closed

    Proposal for interior alterations to existing office space on the 4th floor, unit #400. Tenant is "RBC".

    Nov 16, 2009 · 325 FRONT ST W
  • Building permit09 168755Closed

    Installation of two(2) backflow prevention devices, one is a 6" backflow device and the other is a 4" backflow prevention device. The 6" device is to be installed on the lower level of 325 Front Street West and the 4" device is to be installed at 315 Front Street West (Convenience Address) in the meter room level B2.

    Nov 12, 2009 · 325 FRONT ST W
  • Building permit09 153452Closed

    Permit for interior alterations to add new take out restaurant on ground floor lobby of existing office building - On The Go

    Nov 12, 2009 · 325 FRONT ST W
  • Building permit09 177813Closed

    Interior alterations to existing office space - Floor 4 - RBC - PHASE 2 - ESD - North West Corner of Floor. Please see - 09 106268 BLD for Phase 1 - Building Matrix and Fire Life Safety, Please refer to Phase 1 permit.

    Oct 29, 2009 · 325 FRONT ST W
  • Building permit09 175158Closed

    fire alarm permit for existing office building - convenience address is 315 Front Street.

    Oct 29, 2009 · 325 FRONT ST W
  • Building permit09 172020Closed

    Interior alterations to office space, room 203 on the 2nd floor for tenant "SYMCOR". This proposal includes HVAC.

    Oct 7, 2009 · 325 FRONT ST W
  • Building permit09 106268Closed

    Interior alterations to existing office space - floors 3 and 4 - RBC office space

    Mar 3, 2009 · 325 FRONT ST W
  • Building permit08 220751Closed

    Building permit for structural support for new HVAC installation to cool LAN room floor - Floors 5 and 6. SEE HVAC PERMIT FOR ADDITIONAL INFORMATION

    Nov 26, 2008 · 325 FRONT ST W
  • Building permit08 218283Closed

    Proposal to add sheet metal plenum to existing computer room A/C units.

    Nov 24, 2008 · 325 FRONT ST W
  • Building permit08 217967Closed

    HVAC alterations by adding sheet metal plenum on top of computer room a/c unit

    Nov 24, 2008 · 325 FRONT ST W
  • Building permit08 209435Closed

    Interior alterations to expand computer room on 3rd floor. New FHC. ( Phase 1 on drawings only)Single tenant floor.

    Oct 15, 2008 · 325 FRONT ST W
  • Building permit08 185385Closed

    permit to add a kitchen sink to basement level - Royal Bank Building.

    Jul 23, 2008 · 325 FRONT ST W
  • Building permit08 183918Closed

    interior alterations to existing office space - ground floor - Royal Bank.

    Jul 22, 2008 · 325 FRONT ST W
  • Building permit08 172566Closed

    Interior alterations to existing office space - ground floor - security office

    Jun 23, 2008 · 325 FRONT ST W
  • Building permit08 151301Closed

    Interior alterations to offices at portions of the eleventh floor. **RBC Financial**

    Apr 30, 2008 · 325 FRONT ST W
  • Building permit08 110426Closed

    Interior alterations at the tenth floor **RBC Financial Group**

    Mar 14, 2008 · 325 FRONT ST W
  • Building permit08 112405Closed

    install new fluid cooler in existing mechanical room and install new acoustic surround to exisitng roof mounted chiller. SEE PERMIT NUMBERS 06 142564 BLD AND HVAC - 07 167586 BLD AND HVA. FOR REFERENCE

    Mar 4, 2008 · 325 FRONT ST W
  • Building permit08 106195Closed

    Interior alterations to existing offices on ninth floor. **RBC Financial Group**

    Feb 6, 2008 · 325 FRONT ST W
  • Building permit07 287123Closed

    Interior Alterations to existing office space on the third floor. **Royal Bank**

    Dec 19, 2007 · 325 FRONT ST W
  • Building permit07 246827Closed

    Interior altertions to existing offices on the fifth floor.

    Jul 30, 2007 · 325 FRONT ST W
  • Building permit07 164432Closed

    interior alterations to existing office space - floor 16 - RBC canada

    May 31, 2007 · 325 FRONT ST W
  • Building permit07 167586Closed

    Building permit for structural support for new mechanical equipment on roof - see HVAC permit for HVAC details

    May 31, 2007 · 325 FRONT ST W
  • Building permit07 130472Closed

    Interior Alterations to existing office space - interior alterations to floor 17 - Royal Bank

    Apr 16, 2007 · 325 FRONT ST W
  • Building permit06 182850Closed

    HVAC - Interior alterations to existing office on the lower level (Promenade Lower Level)

    Nov 20, 2006 · 325 FRONT ST W
  • Building permit06 176546Closed

    HVAC - Interior alterations to a portion of an existing office space on the lower level

    Oct 13, 2006 · 325 FRONT ST W
  • Building permit06 161728Closed

    Interior alterations to remove office to portion of exisitng Office on 2nd floor

    Aug 15, 2006 · 325 FRONT ST W
  • Building permit06 156196Closed

    Interior alterations to 14th floor. Single Tenant

    Jul 26, 2006 · 325 FRONT ST W
  • Building permit06 142564Closed

    Proposal to construct a 6th sty penthouse addition to house 4 new diesel emergency generators and associated equipment. Also construct a fuel oil storage for 15 000 gallaons of fuel oil and 5 000 gallons of urea below existing paved surface on exterior (south side of building). See PPR 06 124035

    Jul 7, 2006 · 325 FRONT ST W
  • Building permit06 139319Closed

    Make interior alterations to 13th floor office.

    Jul 5, 2006 · 325 FRONT ST W
  • Building permit06 128370Closed

    HVAC - Interior alterations to an existing office space on the ground floor - Interior Alterations

    May 23, 2006 · 325 FRONT ST W
  • Building permit06 128353Closed

    Interior alterations to an existing office space on the promenade floor level

    May 23, 2006 · 325 FRONT ST W
  • Building permit06 133596Closed

    Interior alterations/new office desk stations reconfiguring to existing office space on 7th floor. Full Tenant

    May 18, 2006 · 325 FRONT ST W
  • Zoning review06 124035 ZPRClosed
    Apr 7, 2006 · 325 FRONT ST W
  • Building permit06 113916Closed

    Make interior alterations to portions of 5th floor office.

    Mar 13, 2006 · 325 FRONT ST W
  • Building permit06 102407Closed

    Interior Alterations on part of 8th floor.

    Feb 7, 2006 · 325 FRONT ST W
  • Building permit06 102420Closed

    Interior Alterations to part of ground floor.

    Jan 25, 2006 · 325 FRONT ST W
  • Building permit05 116873Closed

    Make interior alterations to existing office space.

    May 18, 2005 · 325 FRONT ST W
  • Building permit04 183684Closed

    HVAC - Interior alterations of office space - 6th floor - Interior Alterations

    Dec 3, 2004 · 325 FRONT ST W
  • Building permit04 180080Closed

    Install 1 electro-magnetic locking device on the 2nd floor.

    Oct 7, 2004 · 325 FRONT ST W
  • Building permit04 172917Closed

    HVAC - Make interior alterations to portion of the 1st and 2nd floor. Tenant: Symcor. Existing and proposed: Office Building. - Interior Alterations

    Sep 29, 2004 · 325 FRONT ST W
  • Building permit04 149923Closed

    HVAC - Make interior alterations to portion of the 3rd floor. Tenant: Royal Bank of Canada. Existing and proposed: Office Building - Interior Alterations

    Jul 5, 2004 · 325 FRONT ST W
  • Building permit04 131000Closed

    Interior alterations to offices on 4th floor

    May 13, 2004 · 325 FRONT ST W
  • Building permit04 129148Closed

    Install one electro-magnetic locking device on the 2nd floor.

    Apr 29, 2004 · 325 FRONT ST W
  • Building permit03 201579Closed

    Revision to change location of maglock from 2nd floor to lower level (promenade)

    Feb 5, 2004 · 325 FRONT ST W
  • Building permit03 202005Closed

    To make interior alterations on a portion of ground floor and 2nd floor. Existing and Proposed use : Office

    Jan 13, 2004 · 325 FRONT ST W
  • Building permit03 181856Closed

    Make interior alterations to portion of the main and 4th floor. Tenant: Symcor Inc. Existing and proposed: Office Building

    Nov 12, 2003 · 325 FRONT ST W
  • Building permit03 175948Closed

    Install 2 mag locks on ground floor elevator lobby double doors

    Sep 18, 2003 · 325 FRONT ST W
  • Building permit03 140607Closed

    Make interior alterations to ground floor of existing office.

    Jun 27, 2003 · 325 FRONT ST W
  • Building permit03 130752Cancelled

    Relocate exhaust hood to existing kitchen exhaust system in basement in existing cafeteria.

    May 22, 2003 · 325 FRONT ST W
  • Building permit03 130689Closed

    install tim horton's shutter cart in existing basement cafeteria

    May 8, 2003 · 325 FRONT ST W
  • Building permit03 122732Closed

    make interioir alterations to 15th floor. (tenant: royal bank of canada)

    Apr 16, 2003 · 325 FRONT ST W
  • Building permit03 109260Closed

    make interior alterations to portion of 12th floor tenant: royal bank of canada

    Mar 6, 2003 · 325 FRONT ST W
  • Zoning review02 115434 LTOClosed
    Mar 4, 2002 · 325 FRONT ST W
  • Building permit01 190849Closed

    make interior alterations to portion of 9th floor tenant: royal bank (convenience address 315 front st w)

    Nov 1, 2001 · 325 FRONT ST W
  • Building permit01 144893Closed

    make interior alterations to sunken staff lounge area by install new interior stair. also relocate emergency exit door at same location. edc

    Jul 20, 2001 · 325 FRONT ST W
  • Building permit01 156652Closed

    make interior alterations on 1st floor for existing office. tenant: Royal Bank - Human Resources Dept.

    Jul 12, 2001 · 325 FRONT ST W
  • Building permit01 135658Closed

    Install 1 ks on portion of 3rd floor for office space.Tenant: Symcor Services cost included in 01 135650

    Jul 9, 2001 · 325 FRONT ST W
  • Building permit01 135653Closed

    Alterations to HVAC on portion of 3rd floor for office space. Tenant: Symcor Services cost included in 01 135650

    May 14, 2001 · 325 FRONT ST W
  • Building permit01 135650Closed

    Install partitions on portion of 3rd floor for office space. Tenant: Symcor Services

    May 10, 2001 · 325 FRONT ST W
  • Building permit01 119945Closed

    alter hvac system and related ductwork - 4th floor cost included in bp 01-119940

    Mar 26, 2001 · 325 FRONT ST W
  • Building permit01 119940Closed

    make interior alterations to portion of 4th floor,

    Mar 26, 2001 · 325 FRONT ST W
  • Building permit01 116075Closed

    install wheelchair platform lift unit from ground floor to basement

    Mar 20, 2001 · 325 FRONT ST W
  • Building permit00 348560Closed

    make alterations on 4th floor existing computer data centre. tenant: (royal bank) edc

    Mar 5, 2001 · 325 FRONT ST W
  • Building permit00 348461Closed

    install on ground flooor existing computer data centre: 1 w.c., 1 w.b., 1 k.s. tenant: (symcor services) cost included in 348440 edc

    Jan 30, 2001 · 325 FRONT ST W
  • Building permit00 348457Closed

    h.v.a.c. alter ductwork ground flooor existing computer data centre. tenant: (symcor services) cost included in 348440 edc

    Nov 20, 2000 · 325 FRONT ST W
  • Building permit00 348440Closed

    make alterations on ground flooor existing computer data centre. tenant: (symcor services) edc

    Oct 26, 2000 · 325 FRONT ST W
  • Building permit00 324787Closed

    make alterations by constructing non-load bearing wall on 4th floor of existing computer data centre. (one tenancy). (symcor services) edc

    Aug 3, 2000 · 325 FRONT ST W
  • Zoning review93 024638 LTOClosed
    Jan 18, 1993 · 315 FRONT ST W
  • Zoning review92 025223 LTOClosed
    Feb 26, 1992 · 315 FRONT ST W
  • Zoning review84 026697 LTOClosed
    Jul 20, 1984 · 325 FRONT ST W

Check before you build

  • Zoning not in By-law 569-2013

    Needs a closer look

    This lot is not covered by the citywide zoning by-law's map. It is probably still governed by a former municipal by-law, which this tool does not read yet.

    Zoning By-law 569-2013

Lot facts

Area
16,349 m²
Frontage
90.5 m
Depth
200.3 m
Street
Blue Jays Way
Corner lot
Yes, also on Front St W200.3 m along it
Public lane
None
House footprint
7,554 m²
Back yard
60.7 mhouse to rear lot line
Side yards
0.8 m and 3.9 mhouse to side lot lines
Buildings on the lot
2house, garage, sheds
Max height
—
Max lot coverage
—

House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.

  • 3 City trees in front of this lot. The City's street tree inventory lists 3 trees at this address: maple, red (10 cm), honey locust (7 cm), honey locust (6 cm). Diameter is the trunk at breast height. Source

Around this lot

Minor variances approved
89%8 of 9 decisions
Garden suite permits
0
Laneway suite permits
0
Multiplex permits
0
Development applications
15

Within 300 m, last 10 years. 0 suite and multiplex permits: no more than at most Toronto houses (median 3). 9 variance decisions: no more than at most Toronto houses (median 19).

Recent variance decisions in the same zone

  • Minor varianceApproved

    To alter the development standards, as approved under Site Specific Zoning By-law 135-2026 (OLT), for the 60-storey mixed-use building by converting the office spaces into residential units from floors 3 to 7, and to increase the number of storeys to 65-storeys; the building height from 202.5 m to 214 m (including the mechanical penthouse); and the maximum gross floor area. This is currently under the review of Site Plan Control (File No. 20 233433 STE 10 SA). There will be a total of 807 residential dwelling units on this lot.

    277 WELLINGTON ST W · Apr 15, 2026 · 197 m away
  • Minor varianceApproved

    To alter the development standards (as approved under Site Specific Zoning By-laws 1061-2014 and 1062-2014) for a 36-storey mixed-use building, to increase the maximum permitted residential gross floor area, and to reduce the rate of ¿short term¿ bicycle parking spaces on-site.

    57 SPADINA AVE · Jul 23, 2025 · 426 m away
  • Minor varianceApproved

    To alter the development standards (as approved under Site Specific Zoning By-law 1027-2014) for the 54-storey office building by enclosing the existing ground floor outdoor patio for a new ground floor eating establishment.

    156 FRONT ST W · Mar 19, 2025 · 492 m away
  • Minor varianceApproved

    To alter the development standards (as approved under Site Specific Zoning By-laws 754-2021(OLT) and 757-2021(OLT)) for the 49-storey mixed-use building (currently under construction) by increasing the overall building height, and the total number of dwelling units from 612 to 630 units (by redesigning the penthouse units located on the 47, 48, and 49 floors into smaller units that will be accessed by the elevator overrun structure). Also, to reduce the number of parking spaces on-site.

    400 KING ST W · Nov 27, 2024 · 422 m away
  • Minor varianceApproved

    To permit the reduction of residential parking spaces provided within the 48-storey mixed-use building.

    321 KING ST W · Aug 28, 2024 · 339 m away

Latest activity nearby

  • Zoning review

    Closed

    400 FRONT ST W · Nov 23, 2026 · 266 m away
  • Building permit

    Proposed interior alterations to an existing retail shell space.

    99 BLUE JAYS WAY · Nov 18, 2026 · 276 m away
  • Building permit

    1 projecting sign**PIZZA BAR**

    230 WELLINGTON ST W · Nov 18, 2026 · 234 m away
  • Building permit

    PROPOSED GAMING ARCADE AND SECONDARY CAFE USE

    365 FRONT ST W · Nov 17, 2026 · 178 m away
  • Building permit

    Proposal to undertake interior alterations to convert existing office space into a lounge area.

    250 FRONT ST W · Nov 17, 2026 · 213 m away
  • Zoning review

    Under Review

    15 MERCER ST · Nov 13, 2026 · 267 m away
  • Building permit

    Rev 01 - Renovation of existing club/suite spaces at level 400 - Phase 5Proposed renovation of existing club/suite spaces at level 400.

    1 BLUE JAYS WAY · Nov 12, 2026 · 120 m away
  • Building permit

    Proposal to construct a temporary shipping container structure. Set up - Oct 30, 2026; Tear down - Jan. 31, 2027

    400 FRONT ST W · Nov 10, 2026 · 266 m away
  • Building permit

    Proposal for existing offices to be converted into office and broadcasting studios.

    250 FRONT ST W · Nov 5, 2026 · 213 m away
  • Building permit

    Proposed modernaization and replacement of the existing Fire Alarm Control Panel (FACP) serving two existing residential condominium buildings,

    361 FRONT ST W · Oct 30, 2026 · 152 m away

Neighbourhood: Harbourfront-CityPlace

About the area around the lot, not the lot itself.

Nearest station
St. Andrew Station9 min walk
Nearest TTC stop
Spadina Ave at Front St West North Side6 min walk
Nearest cycling route
Blue Jays WayBike Lane, 2 min walk
Nearest traffic count
14,693 vehicles in 14 hJohn St / Front St W / Isabella Valancy Crawford Park Trl, 120 m away, Sep 11, 2025
Serious collisions within 500 m
92021–2026, killed or seriously injured: 1 fatal, 3 with pedestrians, 5 with cyclists
Parks
Isabella Valancy Crawford Park1 min walk
Northern Linear Park3 min walk
Bobbie Rosenfeld Park4 min walk

Schools within 1 km

  • JEAN LUMB PUBLIC SCHOOL English Public 9 min walk
  • BISHOP MACDONELL CATHOLIC ELEMENTARY English Separate 9 min walk
  • ALPHA ALTERNATIVE & OASIS ALTERNATIVE English Public 12 min walk
  • OGDEN JR PUBLIC SCHOOL English Public 14 min walk
  • OCAD UNIVERSITY - INCLUSIVE DESIGN INSTITUTE University 15 min walk
  • OCAD UNIVERSITY - STUDENT CENTRE University 16 min walk

Being near a school does not mean the lot is in its catchment; check with the board.

2021 Census

FigureHarbourfront-CityPlaceMedian neighbourhood
Median household income (2020)$90,000$84,500
Households that own their home40%54%
Population (2021)28,13516,813
Homes built in 1960 or before0%29%
Homes needing major repairs2%7%

Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.

Police-reported crime, 2025

Per 100,000 peopleHarbourfront-CityPlaceCity median
Assault883.3636.3
Robbery48.169.5
Homicide2.85.3
Shootings8.510.5
Auto theft56.6192.6
Theft over $5,00056.646.1
Break and enter141.6172.8
Theft from vehicles121.7188.1

Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.

Something here not right?

Sources

  • Building permits on this lot since 2000: Permits issued or applied for since about 2000, with status.
  • Committee of Adjustment files since 2001: Minor variances and consents (lot splits) on this lot and nearby, with decisions.
  • Development applications: Rezoning, site plan, subdivision and condominium applications.
  • Preliminary zoning reviews: Zoning reviews requested before a permit or variance application.
  • Zoning and overlays: Zoning By-law 569-2013 zone, height, coverage, policy area, parking, rooming house, priority retail street and downtown setback overlays.
  • Lot boundary, street and lane: Lot polygon, its addresses, the street it fronts, corner and public lane contact, with frontage and depth measured from the boundary; City of Toronto land in City use, which is not a home.
  • House and yards: Footprint and roof height of the house and other buildings, and the yard behind the house, from the City's 3D Massing (updated yearly, illustrative).
  • City trees in front of the lot: City-owned trees on the street allowance at this address, with species and trunk diameter. Private trees on the lot are not in open data.
  • Heritage: Heritage Register (listed and designated properties), Official Plan Amendment 720 properties and properties removed from the Register under the 2022 two-year limit.
  • TRCA regulated area: Valleys, floodplains, shorelines and wetlands regulated by the Toronto and Region Conservation Authority.
  • Ravines and natural features: Ravine and Natural Feature Protection area (Chapter 658, map last published 2019), Natural Heritage System and Environmentally Significant Areas.
  • Official Plan policies: Site and Area Specific Policies, Secondary Plans and Major Transit Station Areas covering the lot.
  • Rooming houses, short-term rentals and rental buildings: Multi-tenant house licences, short-term rental registrations and RentSafeTO evaluations at this address.
  • Neighbourhood context: Neighbourhood, 2021 Census figures, police-reported crime rates, schools, parks, TTC stops, cycling routes, serious collisions and traffic counts nearby. Area context only, not a finding about the lot.
  • Orders and by-law investigations: Outstanding Toronto Building orders, and by-law investigations open now or closed in the last two years. Fire and Public Health orders and older closed files are not published.
  • Address points: loaded Nov 22, 2026, published Nov 20, 2026
  • Toronto Building orders: loaded Nov 28, 2026, published Nov 27, 2026
  • Neighbourhood Profiles, 2021 Census: loaded Oct 14, 2026, published Oct 6, 2023
  • Street centrelines: loaded Nov 22, 2026, published Nov 20, 2026
  • City-owned land: loaded Nov 22, 2026, published Nov 16, 2026
  • Committee of Adjustment open applications: loaded Nov 28, 2026, published Nov 27, 2026
  • Committee of Adjustment decisions: loaded Nov 28, 2026, published Nov 27, 2026
  • Committee of Adjustment decisions 2001-2016: loaded Oct 14, 2026, published Feb 20, 2026
  • Collisions with people killed or seriously injured (Toronto Police Service): loaded Nov 22, 2026, published Nov 21, 2026
  • Neighbourhood crime rates (Toronto Police Service): loaded Oct 14, 2026, published Feb 20, 2026
  • Cycling network: loaded Nov 22, 2026, published Nov 16, 2026
  • Development applications: loaded Nov 28, 2026, published Nov 28, 2026
  • Environmentally Significant Areas: loaded Oct 14, 2026, published Mar 16, 2026
  • Green spaces: loaded Nov 15, 2026, published Nov 10, 2026
  • Heritage register: loaded Oct 14, 2026, published Sep 1, 2026
  • Former heritage listings: loaded Oct 14, 2026, published Jul 3, 2025
  • Official Plan Amendment 720 heritage list: loaded Oct 14, 2026, published Sep 1, 2026
  • 3D Massing building footprints: loaded Oct 14, 2026, published Dec 2, 2025
  • By-law investigation addresses: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigation deficiencies: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigations: loaded Nov 28, 2026, published Nov 27, 2026
  • Major Transit Station Areas: loaded Oct 14, 2026, published Feb 3, 2026
  • Natural Heritage System: loaded Oct 14, 2026, published Mar 16, 2026
  • Neighbourhoods: loaded Oct 14, 2026, published Feb 20, 2026
  • Property boundaries: loaded Nov 27, 2026, published Nov 27, 2026
  • Active building permits: loaded Nov 28, 2026, published Nov 27, 2026
  • Cleared building permits: loaded Nov 28, 2026, published Nov 27, 2026
  • Cleared building permits 2000-2016: loaded Oct 14, 2026, published Jul 8, 2025
  • Preliminary zoning reviews: loaded Nov 28, 2026, published Nov 27, 2026
  • Ravine and natural feature protection: loaded Oct 14, 2026, published Jul 23, 2019
  • RentSafeTO evaluations: loaded Nov 28, 2026, published Nov 27, 2026
  • Multi-tenant house licences: loaded Nov 28, 2026, published Nov 27, 2026
  • Site and Area Specific Policies: loaded Oct 14, 2026, published Mar 16, 2026
  • School locations: loaded Oct 14, 2026, published May 27, 2026
  • Secondary Plans: loaded Oct 14, 2026, published Mar 16, 2026
  • Street trees: loaded Oct 14, 2026, published Jun 4, 2026
  • Short-term rental registrations: loaded Nov 28, 2026, published Nov 27, 2026
  • Traffic counts at intersections: loaded Nov 22, 2026, published Nov 21, 2026
  • TRCA regulation limit: loaded Oct 14, 2026, published Apr 29, 2026
  • TTC stops (GTFS): loaded Nov 8, 2026, published Nov 5, 2026
  • Zoning by-law: loaded Oct 14, 2026, published Feb 20, 2026
  • Lot coverage overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Height overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Parking zone overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Policy area overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Priority retail streets: loaded Oct 14, 2026, published Feb 20, 2026
  • Rooming house overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Zoning setbacks: loaded Oct 14, 2026, published Feb 20, 2026

Contains information licensed under the Open Government Licence – Toronto. TRCA regulation limit © TRCA.

Screening tool based on City of Toronto and TRCA open data. Not a zoning review or legal opinion. Site-specific exceptions, amendments not yet in the open data, minor variances and other by-laws can change the answer. Confirm with a Preliminary Project Review or Zoning Certificate from Toronto Building before buying or designing.

Flag an error

What is not right?

The problem

The records come from the City's open data; we check each flag against them. Your email is used only to answer this.