Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
Heritage property: designated (Part IV)
Needs a closer lookOn the City's Heritage Register. Demolition and exterior changes need heritage review.
What it means. Renovations, additions and demolition can take longer, cost more or be refused.
How to confirm. Heritage Planning at the City confirms the status and what it covers. Details
City of Toronto Heritage Register2 building permits open, the oldest since 2022
Needs a closer lookStill open in the City's records: 22 157388 (Alternate Solution to address openings within floor assemblies of the automated parking..., 2022, status Deficiency Notice Issued); 21 115462 (Proposal for alterations to the existing place of worship including interior and exteri..., 2022, status Inspection).
What it means. An open permit can mean work that was never finished or never passed final inspection. After closing, finishing it or closing the file can fall to you.
How to confirm. Ask the seller for the final inspection records. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016)Work or applications in progress
Good to knowRecent records on this lot: 26 233351 (Deferred Fees from folder 21 233351 (RSN-5018804) ZoningProcess RSN 79967909, 2026); 26 130612 STE 11 CD (Draft Plan of Standard Condominium to create 339 residential units and 1 retail unit wi..., 2026).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications1 Committee of Adjustment file on this lot
Good to know1 approved. B0100/21TEY (To obtain consent to sever the property into three lots and to create various easements..., 2022).
What it means. Approved variances and consents stay with the property, including any conditions in the decision. They allow what was approved, not more.
How to confirm. Decisions are in the Application Information Centre; older files are available from the Committee of Adjustment office. Details
City of Toronto, Committee of Adjustment applications (2001 onwards)10 development applications open within 300 m
Good to know10 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 37 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
21 records on file: more than at 100% of Toronto houses (median 0).
- Building permit26 233351Open
Deferred Fees from folder 21 233351 (RSN-5018804) ZoningProcess RSN 79967909
Jun 26, 2026 · 300 BLOOR ST W - Development application26 130612 STE 11 CDDraft Plan Approved
Draft Plan of Standard Condominium to create 339 residential units and 1 retail unit within a 34-storey building.
Mar 17, 2026 · 300 BLOOR ST W · City file - Building permit21 233351Closed
Part Permit - Proposal for the construction of a 29 storey tower containing 20,055 square metres of residential space and 6,509 square metres of non-residential space. Application is in conjunction with Facade Retention permit 21 115462 BLD 00 BA (300 BLOOR ST W).
Sep 5, 2025 · 300 BLOOR ST W - Zoning review23 173075 ZAPCancelledJul 12, 2023 · 300 BLOOR ST W
- Building permit22 157412Approved
Alternate Solution - The 65 mm hose connections will be provided in lieu of hose stations (38 mm and 65 mm hose valves, 38 mm hose and nozzle) required by the 2012 Ontario Building Code. The standpipe system and hose connections will be located within exit stair enclosures. Additional fire hose valves will be located throughout the floor area to achieve fire hose coverage.
Jun 6, 2022 · 300 BLOOR ST W - Building permit22 157388Deficiency Notice Issued
Alternate Solution to address openings within floor assemblies of the automated parking system levels located at the 300 Bloor St. W. building
Jun 6, 2022 · 300 BLOOR ST W - Zoning review20 122085 PSPClosedApr 6, 2022 · 300 BLOOR ST W
- Consent (lot split)B0100/21TEYApproved
To obtain consent to sever the property into three lots and to create various easements/rights-of-way.
Mar 2, 2022 · 300 BLOOR ST W
Show 13 older records
- Building permit21 115462Inspection
Proposal for alterations to the existing place of worship including interior and exterior demolition to the place of worship and ancillary structure - pigeon house.
Mar 1, 2022 · 300 BLOOR ST W - Building permit21 180534Cancelled
To erect and display two non-illuminated ground signs.*****CIELO*****
Oct 4, 2021 · 300 BLOOR ST W - Development application20 122085 STE 11 SAClosed
Application to permit the redevelopment of the site for a 34-storey (TLAB approved) mixed-use building containing office, retail/café, worship and community, and residential uses (349 dwelling units). The majority of the existing church and the entirety of Pidgeon House would be retained.
Mar 4, 2020 · 300 BLOOR ST W · City file - Zoning review17 279303 PRZClosedJan 12, 2018 · 300 BLOOR ST W
- Development application17 279303 STE 20 OZClosed
Zoning By-law Amendment Application to permit the redevelopment of the site for a 29-storey mixed-use building containing office, retail/café, worship and community, and residential uses (249 dwelling units). The majority of the existing church and the entirety of Pidgeon House would be retained.
Dec 27, 2017 · 300 BLOOR ST W · City file - Zoning review06 121853 LTOClosedMar 30, 2006 · 300 BLOOR ST W
- Zoning review05 115580 ZPUClosedMar 15, 2005 · 300 BLOOR ST W
- Zoning review03 175442 LTOClosedSep 17, 2003 · 300 BLOOR ST W
- Zoning review99 022670 LTOClosedJul 22, 1999 · 300 BLOOR ST W
- Zoning review98 026262 LTOClosedJun 11, 1998 · 300 BLOOR ST W
- Building permit95 020672Closed - Dormant
INSTALL FIXTURES: BASEMENT: 2 W.C., 2 W.B. COST INCL. 377698 /LM
Oct 30, 1995 · 300 BLOOR ST W - Building permit95 021639Closed - Dormant
INSTALL FIXTURES: 1ST FL: 2 W.C. 2 W.B. SEE 377698 /LM
Oct 4, 1995 · 300 BLOOR ST W - Zoning review93 024894 LTOClosedMar 22, 1993 · 300 BLOOR ST W
Check before you build
Site-specific exception 900.11.10(289)
Needs a closer look21 site-specific rules apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
On 300 Bloor Street West and 478 Huron Street, if the requirements of Section 7 of this By-law and Schedule A of By-law 73-2021 are complied with a building , structure , addition or enlargement maybe erected or constructed in compliance with
- Rule B
to (U) below; (B) Despite regulation 40.10.40.40(1), the maximum permitted gross floor area of all buildings and structures on the lands must not exceed 27,000 square metres, of which: (i) residential uses must not exceed 20,475 square metres; and (ii) non-residential uses must not exceed 6,525 square metres
- Rule C
Despite regulations 40.5.40.10(1) and 40.5.40.10(2) the height of a building or structure is measured from the Canadian Geodetic Datum elevation of 115.00 metres to the elevation of the highest point of the building
- Rule D
Despite regulations 40.10.40.70(2), 40.10.40.80(2), clauses 40.5.40.60, 40.10.40.60 and 40.10.40.71 and article 600.10.10, the minimum required building setbacks and minimum distance between main walls for each level of the building are as shown in metres on Diagram 3 of By-law 73-2021.
- Rule E
Despite clauses 40.5.40.60, 40.10.40.60 and (D) above, the following are permitted to encroach into a required building setback or distance between main walls : (i) a maximum of 0.50 metres for; cornices, light fixtures, ornamental and architectural features, vertical screen elements at balconies, projecting panel system at exterior walls, parapets, art and landscape features, patios, decks, pillars, pergolas, trellises, terraces, eaves, window sills, planters, ventilation shafts, guardrails, balustrades, railings, stairs, stair enclosures, doors, wheelchair ramps, fences, covered walkways, screens, site servicing features, awnings and canopies including support structures, window washing equipment, bicycle parking facilities and underground garage ramps and associated structures ; window washing equipment, bicycle parking facilities and underground garage ramps and associated structures
- Rule F
Despite regulations 40.5.40.10(4)(C), (5), (6) and (7) and 40.10.40.10(2), (4) and (5), no portion of a building or structure , including the mechanical penthouse, may exceed the height in metres specified by the numbers following the symbol HT on Diagram 3 of By-law 73-2021, with the exception of the following: (i) the portions of the existing buildings on the lands shown in shading on Diagram 3 to a maximum height of 38.0 metres; (ii) the erection or use of structures on any roof used for outdoor amenity space or open air recreation, maintenance, safety, wind protection purposes, pergolas, cabanas, vestibules providing access to outdoor amenity space or recreation space, partitions dividing outdoor recreation areas, provided such projections are limited to a maximum vertical projection of 4.5 metres above the permitted building heights shown on Diagram 3; (iii) the erection or use of structures on the roof used for green roof purposes, roof assembly, air intakes, vents and ventilating equipment, chimney stacks, exhaust flues, parapets, elevator overruns and garbage chute overruns and elements associated with green energy and renewable energy facilities, provided such projections are limited to a maximum of 2.0 metres above the permitted building heights shown on Diagram 3; and (iv) lightning rods and window washing equipment provided such projections are limited to a maximum of 6.0 metres above the permitted building heights shown on Diagram 3.
- Rule G
Despite regulation 40.10.40.50(1) and 40.10.40.50(2), a minimum of 3.88 square metres of amenity space for each dwelling unit must be provided, of which: (i) a minimum of 1.88 square metres for each dwelling unit must be indoor amenity space ; and (ii) a minimum 40 square metres is outdoor amenity space in a location adjoining or directly accessible to a portion of the indoor amenity space .
- Rule H
Section 150.50, with regards to Places of Worship , does not apply.
- Rule I
Despite clause 200.5.10.1, Table 200.5.10.1 and regulations 200.10.1(1) and (2) parking spaces, must be provided and maintained on the lands, in accordance with the following minimum requirements: (i) 0.31 parking spaces per dwelling unit for residents; (ii) 20 parking spaces for the place of worship ; (iii) 25 parking spaces for residential visitor and non-residential uses; and (iv) 3 'car-share' parking spaces ; (v) Parking spaces may be provided within an 'automated parking system' as defined in 5 (ii) of By-law 73-2021; and (vi) If parking spaces are provided in an 'automated parking system' as defined in 5 (ii) of By-law 73-2021, the 3 'car-share' parking spaces referenced in (I)(iv) above are not required.
- Rule J
Section 200.5 and Article 200.10.1 do not apply to parking spaces within an 'automated parking system'.
- Rule K
Section 200.15 does not apply to accessible parking spaces located within an 'automated parking system.'
- Rule L
A 'parking cabin' contained within an 'automated parking system' will be provided on the lands in accordance with the following dimensions: (i) A minimum length of 6.0 metres; (ii) A minimum width of 6.0 metres; and (iii) A minimum vertical clearance of 2.1 metres.
- Rule M
Despite regulation 230.5.1.10(4) "short-term" bicycle parking spaces may have minimum dimensions of: (i) 1.7 metres in length; (ii) 0.264 metres in width; and (iii) a vertical clearance of 1.9 metres.
- Rule N
Despite regulations 230.5.10.1(1), and 230.5.10.1(5) and Table 230.5.10.1(1), bicycle parking spaces must be provided and maintained on the lands, in accordance with the following; (i) A minimum of 225 long term bicycle parking spaces for the exclusive use of dwellings units ; (ii) A minimum of 25 short-term bicycle parking spaces for the exclusive use of dwelling units ; (iii) A minimum of 9 long-term bicycle parking spaces for the exclusive use of non-residential uses; and (iv) A minimum of 15 short-term bicycle parking spaces for the exclusive use of non-residential uses.
- Rule O
Despite regulation 230.5.1.10(7), shower and change facilities are not required
- Rule P
Despite clauses 40.10.90.1 and 220.5.10.1(5), a minimum of one type "G" loading space and two type "C" loading space must be provided and maintained on the lands
- Rule Q
Despite regulation 40.10.40.1(1) residential use portions of the mixed use building may be located at the same level or below non-residential uses portions of the building
- Rule R
At least 10 percent of all dwelling units must have three or more bedrooms
- Rule S
For the purposes of this exception, amenity space may include a maximum of 1 guest suite provided: (i) The guest suite does not exceed 55 square metres; and (ii) The guest suite does not include food preparation facilities.
- Rule T
'Privately-owned publicly accessible open space' having a minimum area of 368 square metres must be provided on the ground level generally as shown within the shaded areas on Diagram 4 of By-law 73-2021
- Rule U
Parking pallets will not conform to the parking space and accessible parking space dimensions set out in City of Toronto Zoning By-law 569-2013 and above in By-law 73-2021.
Lot facts
- Area
- 1,632 m²
- Frontage
- 44.2 mestimated, irregular lot
- Depth
- 46.7 mestimated, irregular lot
- Street
- Bloor St W
- Corner lot
- Yes, also on Huron St46.7 m along it
- Public lane
- None
- House footprint
- 1,279 m²
- Back yard
- 0 mhouse to rear lot line
- Side yards
- 0 m and 1.2 mhouse to side lot lines; 0 is a shared wall
- Buildings on the lot
- 5house, garage, sheds
- Max height
- 18 m
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
- Site and Area Specific Policy 334. The Official Plan has a policy for this site or area that varies the general rules. Read it before relying on zoning alone. Source
- Major Transit Station Area: Spadina. The lot is inside the Spadina Major Transit Station Area approved by the Province (Site and Area Specific Policy 597). Source
- Downtown Plan Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Priority retail street: Bloor Street West. The lot is on a priority retail street. In this zone at least 60% of the ground floor along that street must hold retail, restaurants, offices or similar uses, with entrances within 5 m of the lot line and 60% of the ground floor wall in windows or doors. Source
- Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
- Zone CR 3.0 (c2.0; r2.5) SS2 (x289) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
Around this lot
- Minor variances approved
- 89%17 of 19 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 16
- Development applications
- 27
Within 300 m, last 10 years. 16 suite and multiplex permits: more than at 84% of Toronto houses (median 3). 19 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To convert the existing two-and-one-half-storey commercial building (eating establishment) into a mixed-use building by constructing a rear five-storey addition. This altered building will contain one non-residential unit (including one bar/pub, and five office spaces), one residential dwelling unit (to be located on the fifth storey), side (west) third and fourth storey terraces, a side (east) fifth storey terraces, a rear parking pad (for one visitor parking space and one accessible parking space), and a rear yard ancillary building (waste and recyclable material storage shed). This existing building is a heritage building.
36 PRINCE ARTHUR AVE · Jul 23, 2025 · 460 m away - Minor varianceApproved
To alter the existing two-storey commercial building by increasing the permitted non-residential gross floor area for the restaurant use (through interior alterations).
648 SPADINA AVE · Dec 11, 2024 · 477 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 595-2021(OLT), as amended by City Wide By-law 569-2013), for a new mixed-use building.
316 BLOOR ST W · Dec 13, 2023 · 90 m away - Minor varianceRefused
To alter the development standards, as approved within Site Specific Zoning By-law 73-2021, which include changes to the overall tower height (29-storeys to 34-storeys) and a reduction of indoor amenity space.
478 HURON ST · Nov 8, 2023 · 62 m away - Minor varianceApproved
To alter the existing three-storey building containing office and residential uses, by removing the existing covered parking area between the east and west wing of the building and constructing a ground floor addition for new infilled office space with a new lobby entrance. One parking space will be provided on-site.
23 BEDFORD RD · Jun 21, 2023 · 447 m away
Latest activity nearby
- Building permit
Proposed modification to existing standpipe system related to permit application # 26-15221 BLD 00 BA.
252 BLOOR ST W · Nov 17, 2026 · 294 m away - Building permit
Proposal for HVAC upgrade, replacement of hydronic heating system, ameliorated ventilation
482 HURON ST · Nov 10, 2026 · 81 m away - Building permit
Proposal for HVAC upgrade, replacement of hydronic heating system, ameliorated ventilation
480 HURON ST · Nov 10, 2026 · 72 m away - Building permit
HVAC upgrade, replacement of hydronic heating system, ameliorated ventilation
492 HURON ST · Nov 5, 2026 · 119 m away - Building permit
REPAIRS TO EXISITING REAR SECOND FLOOR DECK
23 MADISON AVE · Nov 5, 2026 · 119 m away - Building permit
Proposal to replace existing roof mounted life-safety natural gas emergency generator with a new outdoor life-safety natural gas generator.
341 BLOOR ST W · Nov 4, 2026 · 99 m away - Building permit
Repairs to existing rear second floor deck
27 MADISON AVE · Nov 4, 2026 · 133 m away - Building permit
Proposal for Installation of roof edge railings, roof mounted stair and ladder ports at TTC's St. George Station -St. George Entrance
139 ST GEORGE ST · Oct 29, 2026 · 204 m away - Building permit
Proposal for installation of roof edge railings, roof mounted stair, fixed ladder and ladder port at TTC's Spadina Stn -Main Entrance
7 SPADINA RD · Oct 28, 2026 · 141 m away - Building permit
Proposal for installation of roof edge railings and ladder port at TTC's Spadina Stn. - Walmer Entrance
9 WALMER RD · Oct 28, 2026 · 292 m away
Neighbourhood: Annex
About the area around the lot, not the lot itself.
- Nearest station
- St George Station3 min walk
- Nearest TTC stop
- Spadina Station2 min walk
- Nearest cycling route
- Bloor St WCycle Track, 1 min walk
- Nearest traffic count
- 10,170 vehicles in 8 hBloor St W / Huron St, 50 m away, Jan 11, 2018
- Serious collisions within 500 m
- 32021–2026, killed or seriously injured: 0 fatal, 0 with pedestrians, 2 with cyclists
- Parks
- Paul Martel Park1 min walk
- Huron - Washington Parkette2 min walk
- Matt Cohen Park2 min walk
Schools within 1 km
- HOWLETT ACADEMY SCHOOL Private 1 min walk
- UNIVERSITY OF TORONTO SCHOOLS Private 2 min walk
- SCHOOL OF CONTINUING STUDIES - U OF T, BLDG 103 University 3 min walk
- PAUL PENNA DOWNTOWN JEWISH DAY SCHOOL & MILES NADAL JEWISH COMMUNITY CENTRE Private 3 min walk
- TADDLE CREEK MONTESSORI SCHOOL Private 4 min walk
- MUNK SCHOOL OF GLOBAL AFFAIRS AT THE OBSERVATORY - U OF T, BLDG 89 University 5 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Annex | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $85,000 | $84,500 |
| Households that own their home | 41% | 54% |
| Population (2021) | 29,300 | 16,813 |
| Homes built in 1960 or before | 40% | 29% |
| Homes needing major repairs | 6% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Annex | City median |
|---|---|---|
| Assault | 1080.9 | 636.3 |
| Robbery | 80.5 | 69.5 |
| Homicide | 5.2 | 5.3 |
| Shootings | 5.2 | 10.5 |
| Auto theft | 116.9 | 192.6 |
| Theft over $5,000 | 114.3 | 46.1 |
| Break and enter | 387.1 | 172.8 |
| Theft from vehicles | 220.9 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.