250 Church StToronto · zoning, lot size and permit records

Also 252 Church St, 254 Church St, 258 Church St, 258 Church St, 260 Church St and 2 more

Commercial residential · CR 4.0 (c2.0; r4.0) SS1 (x311)35.8 × 39.0 m1,254 m²on Dundas St Ecorner, also on Church Stbacks onto Ln W Church S Dundas

Not a single house

A condominium parcel

The City's property boundaries show this parcel as a condominium: the homes on it are units of a condominium corporation, which owns the land and common elements. Build options for a house do not apply; the corporation's status certificate is the document to read before an offer.

Looking at a house nearby? What this means for you

  • A condominium on 0.1 haIts owners share the land and decide together on changes; expect more cars and visitors than a house.
  • Permits or applications open on this parcelRecent records on this lot: 25 261126 (Five illuminated overhanging structure signs, displaying static copy.***KFC***, 2025). Larger work can mean noise and trucks next door; read what each one is for.
  • 12 development applications open within 300 m, up to 71 storeysNew buildings may go up around here in the next years. More change nearby than at 100% of Toronto houses.
  • Major Transit Station Area: DundasThe City plans more homes around the station: good for transit, and more building over time.

Want to check this condo before you buy?

We are building checks for condominiums. Leave your email and we will tell you when it is ready.

N20 m
35.8 m frontage39.0 m deep

Before you offer

From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.

  • Heritage property: designated (Part IV)

    Needs a closer look

    On the City's Heritage Register. Demolition and exterior changes need heritage review.

    What it means. Renovations, additions and demolition can take longer, cost more or be refused.

    How to confirm. Heritage Planning at the City confirms the status and what it covers. Details

    City of Toronto Heritage Register
  • 1 by-law investigation closed in the last two years

    Good to know

    Closed files (Zoning): 25 189355 ZON 00 IR (Zoning, 2025).

    What it means. Someone raised an issue here and the City closed the file. Ask the seller what it was about.

    City of Toronto, Toronto Building orders and Municipal Licensing and Standards investigations
  • Work or applications in progress

    Good to know

    Recent records on this lot: 25 261126 (Five illuminated overhanging structure signs, displaying static copy.***KFC***, 2025).

    What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.

    How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details

    City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications
  • 12 development applications open within 300 m

    Good to know

    12 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 71 storeys. They are listed under Around this lot.

    What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.

    How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details

    City of Toronto, Development Applications

Not in these records

  • Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
  • Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.

History of this lot

42 records on file: more than at 100% of Toronto houses (median 0).

  • Building permit26 101658Closed

    Interior alterations - Unit 2 - Freshslice Pizza

    Jan 30, 2026 · 252 CHURCH ST
  • Building permit25 261126Permit Issued

    Five illuminated overhanging structure signs, displaying static copy.***KFC***

    Dec 12, 2025 · 260 CHURCH ST
  • Building permit25 222576Closed

    Proposal for interior alterations to existing vacant unit for new Restaurant

    Oct 14, 2025 · 252 CHURCH ST
  • By-law investigation25 189355 ZON 00 IRClosed

    Zoning

    Jul 7, 2025 · 252 CHURCH ST
  • Building permit21 246085Closednew building

    REV 01: Revised retail standpipe Proposal to construct a new 52 storey mixed-use building with 4 levels of below grade parking.

    Jun 4, 2025 · 250 CHURCH ST
  • Building permit24 200657Cancelled

    Alternative Solution to protect the diesel fuel line serving the emergency generator with CL4FIRE, Red Fire Protection Thermal Insulation wrap in lieu of locating the gas fuel pipe in a fire enclosure or a service room. The proposed assembly has been evaluated by Canadian Construction Materials Centre (CCMC) evaluation report no.14382-R and Ministry of Municipal Affairs and Housing ruling no. 21-04-367 (14382-R) as an alternative solution for protection of pipe in line with the OBC.

    Aug 19, 2024 · 250 CHURCH ST
  • Building permit24 143513Closed

    Adding 8 maglocks to mixed-use building.

    May 7, 2024 · 250 CHURCH ST
  • Building permit22 102054Closed

    DEMOLITION OF WEST ADDITION TO EXISTING 1 STOREY BUILDING AND ALTERATION TO INTERIOR.

    May 26, 2022 · 260 CHURCH ST
Show 34 older records
  • Building permit22 118372Cancelled

    Proposed alternative solution to address the requirements of Sentences 6.2.3.12(2) & (6)) of the OBC for the minimum separation between the air intake and exhaust openings of some of the residential suites.

    Mar 1, 2022 · 250 CHURCH ST
  • Building permit21 227647Closeddemolition

    Proposal to demolish the existing 3 storey mixed-use building.

    Feb 25, 2022 · 250 CHURCH ST
  • Building permit22 105457Approved

    Proposed alternative solution for a standpipe system.

    Jan 19, 2022 · 250 CHURCH ST
  • Development application21 234913 STE 13 CDClosed

    Draft plan of condo for 681 residential units and 3 commercial units at-grade in the proposed 52-storey mixed-use building.

    Nov 5, 2021 · 258 CHURCH ST · City file
  • Building permit21 228409Cancelleddemolition

    DEMOLITION OF WEST ADDITION TO EXISTING 1 STOREY BUILDING.

    Oct 20, 2021 · 260 CHURCH ST
  • Development application21 187552 STE 13 SAClosed

    Site Plan Approval for a 52-storey mixed-use building having a non-residential gross floor area of 315 square metres, and a residential gross floor area of 37800 square metres. A total of 681 residential dwelling units are proposed.

    Jul 21, 2021 · 260 CHURCH ST · City file
  • Development application20 124315 STE 13 OZClosed

    52-storey, 681 dwelling units, building with retail space at grade

    Mar 10, 2020 · 252 CHURCH ST · City file
  • Zoning review18 272524 ZBAClosed
    Dec 28, 2018 · 254 CHURCH ST
  • Zoning review18 136507 ZSVClosed
    Mar 29, 2018 · 260 CHURCH ST
  • Building permit17 234743Closed

    Proposal to install a back flow prevention device.

    Oct 4, 2017 · 260 CHURCH ST
  • Zoning review11 332177 ZSVClosed
    Dec 30, 2011 · 260 CHURCH ST
  • Zoning review11 276964 ZPUClosed
    Sep 19, 2011 · 250 CHURCH ST
  • Zoning review07 252751 ZSVCancelled
    Aug 14, 2007 · 260 CHURCH ST
  • Zoning review06 191077 ZPRClosed
    Nov 13, 2006 · 260 CHURCH ST
  • Zoning review06 121813 LTOClosed
    Mar 30, 2006 · 254 CHURCH ST
  • Building permit04 117408Closed

    make interior alterations on main floor for travel office, and 2nd floor for apartment

    Mar 18, 2004 · 250 CHURCH ST
  • Zoning review02 155956 LTOClosed
    Jul 19, 2002 · 250 CHURCH ST
  • Building permit01 120282Closed

    install grease interceptor, install fixtures: 1 3compt ks, 2 hand sinks, 1 janitor sink cost included in bp 120272 (( Pizza Pizza store #56)) plans

    Jul 9, 2001 · 260 CHURCH ST
  • Building permit01 120276Closed

    Alter plans as approved under original HP: 01-120276 by altering the equipment layout.

    Jun 19, 2001 · 260 CHURCH ST
  • Building permit01 120272Closed

    make interior alterations for restaurant purposes 18 seats

    Jun 19, 2001 · 260 CHURCH ST
  • Building permit99 110234Closed

    Repair Fire Damage

    Feb 14, 2000 · 250 CHURCH ST
  • Building permit98 023510Closed

    INSTALL KITCHEN EXHAUST SYSTEM. REFER TO APPLICATION NUMBER: 418039

    Nov 12, 1998 · 250 CHURCH ST
  • Building permit98 022436Closed

    INSTALL FIXTURES GROUND FLOOR 2 K.S., 1 CAP. MACH., 1 COFFEE MACH., 2ND FLOOR 1 B.T., 1 SH., 1 W.B., 1 W.C. IN CONNECTION WITH APPL.#418039 GREASE INTERCEPTOR REQUIRED IN RESTAURANT

    Nov 12, 1998 · 250 CHURCH ST
  • Building permit98 022435Closed

    MAKE INTERIOR ALTERATIONS 320SQ.METRESX$3.25=$1040.00 HEALTH DEPT APPROVAL REQUIRED SS

    Nov 9, 1998 · 250 CHURCH ST
  • Zoning review98 025704 LTOClosed
    Feb 18, 1998 · 254 CHURCH ST
  • Zoning review97 027077 LTOClosed
    Nov 24, 1997 · 254 CHURCH ST
  • Zoning review97 026988 LTOClosed
    Oct 30, 1997 · 254 CHURCH ST
  • Zoning review96 025155 LTOClosed
    Jun 21, 1996 · 95 DUNDAS ST E
  • Zoning review96 024379 LTOClosed
    Jan 3, 1996 · 95 DUNDAS ST E
  • Zoning review94 024778 LTOClosed
    Apr 19, 1994 · 95 DUNDAS ST E
  • Zoning review92 025714 LTOClosed
    Jul 6, 1992 · 254 CHURCH ST
  • Zoning review87 030381 LTOClosed
    Sep 4, 1987 · 260 CHURCH ST
  • Zoning review84 026214 LTOClosed
    Mar 5, 1984 · 260 CHURCH ST
  • Zoning review82 025621 LTOClosed
    Jan 14, 1982 · 260 CHURCH ST

Check before you build

  • Site-specific exception 900.11.10(311)

    Needs a closer look

    26 site-specific rules apply to this lot. They can override the standard rules on this page.

    Zoning By-law 569-2013, Chapter 900
Exception 900.11.10(311)Applies

These parts of the exception apply to this lot's address.

  1. Rule A

    On 244, 250, 254, 258, 260 and 262 Church Street, if the requirements of Section 6 and Schedule A of By-law 518-2021 are complied with, a mixed-use building may be constructed in compliance with

  2. Rule B

    to (Z) below; (B) The lot comprises the lands delineated by heavy lines on Diagram 1, attached to By-law 518-2021

  3. Rule C

    Despite regulations 40.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum elevation of 89.60 metres (CGVD1928:pre 1978) and the highest point of the building or structure

  4. Rule D

    Despite regulations 40.10.40.10(1) and 40.5.40.10(4) and (5), the height of the building or structure , including a mechanical penthouse containing equipment and structures used for the functional operation of the building , must not exceed the height as specified in metres by the numbers following the symbol "HT" on Diagram 3 and within the coordinates identified on Diagram 4 of By-law 518-2021 with the exception of the following: (i) lightning rods, window washing equipment, stair enclosures, elevator overruns, parapets, green roof and architectural features, may project above the height limits to a maximum of 2.9 metres; (a) Despite (i), in areas of the building beneath the Obstacle Limitation Surfaces as defined in By-law 1432-2017 and depicted in the hatched area in Diagram 4, lightning rods, window washing equipment, stair enclosures, elevator overruns, parapets, green roof and architectural features, may not project above the height limit of 166.10 metres; (ii) trellises, pergolas, railings, cornices, lighting fixtures, ornamental elements, planters, landscaping , partitions dividing outdoor amenity spaces , guard rails, wheelchair ramps, fences, screens, furniture, and elements or structures providing safety or wind protection to rooftop amenity space , may project above the height limits to a maximum of 2.9 metres; (a) Despite (ii), in areas of the building beneath the Obstacle Limitation Surfaces as defined in By-law 1432-2017 and depicted in the hatched area in Diagram 4, trellises, pergolas, railings, cornices, lighting fixtures, ornamental elements, planters, landscaping , partitions dividing outdoor amenity spaces , guard rails, wheelchair ramps, fences, screens, furniture, and elements or structures providing safety or wind protection to rooftop amenity space , may not project above the height limit of 166.10 metres

  5. Rule E

    Despite regulation 40.10.40.10(7), the permitted maximum number of storeys in a building is 52, excluding the mechanical penthouse

  6. Rule F

    Despite regulation 40.10.40.40 (1), the permitted maximum gross floor area on the lands must not exceed 37,800 square metres, of which: (i) A maximum of 37,485 square metres may be used for residential uses; and (ii) A minimum of 315 square metres may be used for retail uses

  7. Rule G

    Despite regulation 40.5.40.40(3) the gross floor area of a mixed-use building excludes areas used for: (i) alternative housing up to a maximum of 2,750 square metres; (ii) all open to below areas; (iii) hallways and elevator vestibules below ground; and (iv) electrical, utility, mechanical and ventilation rooms on any level of the building

  8. Rule H

    Despite regulations 40.10.40.50 (1) and (2), amenity must be provided in accordance with the following: (i) a minimum of 2.0 square metres of indoor amenity spaces per dwelling unit must be provided; (ii) a minimum of 1.2 square metres of outdoor amenity space per dwelling unit must be provided; (iii) amenity space may include guest suites that do not exceed an aggregate gross floor area of 100.0 square metres; (iv) guest suites and alternative housing do not constitute dwelling units for purposes of this exception; and (v) a minimum of 35 square metres of indoor amenity spaces must be provided for alternative housing use

  9. Rule I

    Despite regulation 40.10.40.70(1), the required minimum building setbacks are as shown on Diagram 3 of By-law 518-2021

  10. Rule J

    Despite regulation 40.5.40.60(1) and Clause 40.10.40.60, the following are permitted to encroach into the required building setbacks shown on Diagram 3 of By-law 518-2021: (i) Canopies, site servicing features, balconies, lighting fixtures, awnings, ornamental elements, architectural features, window sills, planters, guardrails, railings, stairs, wheel chair ramps, vents, screens, and landscape features, may encroach up to a maximum of 2 metres; (a) Despite (i) above, no encroachments are allowed above Canadian Geodetic Datum elevation of 250.0 metres (CGVD1928:pre 1978).

  11. Rule K

    Despite regulation (J) above, no encroachments into the building setbacks are allowed on the portion of the site that is directly adjacent to 91 Dundas Street East as of the date of passing of By-law 518-2021

  12. Rule L

    Despite regulation 200.5.10.1(1) and Table 200.5.10.1, parking spaces for the mixed-use building must be provided and maintained on the lands in accordance with the following: (i) a minimum of 0.10 parking spaces per dwelling unit must be provided and maintained for the use of residents; (ii) a minimum of 12 parking spaces must be provided for retail/visitors; (iii) the required parking spaces for retail/visitors may be provided within a public parking facility on the lot ; and (iv) no parking spaces are required for alternative housing uses

  13. Rule M

    Despite regulation 200.5.1.10(2)(A)(iv), a maximum of 11 parking spaces may be obstructed on one or two sides in accordance with 200.5.1.10(2)(D) without a requirement to increase the minimum width by 0.3 metres

  14. Rule N

    Despite regulations 200.15.1.5(1) and 200.15.1(4), the nearest point of an accessible parking space must be located no more than 10.0 metres, from the nearest point of a barrier-free elevator that provides access to the first storey of the building

  15. Rule O

    Despite regulation 220.5.10.1(2), one Type "G" loading space must be provided and maintained on the lands

  16. Rule P

    Despite regulations 230.5.1.10(4) and (10), bicycle parking spaces must be provided and maintained in accordance with the following: (i) both long-term and short-term bicycle parking spaces may be provided in a stacked bicycle parking space ; (ii) short-term bicycle parking spaces may be located indoors or outdoors in an enclosed or secured room or enclosure; (iii) if a stacked bicycle parking space located in a parking level down to and including parking level P2, is provided in a mechanical device where any portion of a bicycle is situated above or below any portion of an adjacent bicycle, the minimum required width of each such stacked bicycle parking space is 0.35 metres; and (iv) a stacked bicycle parking space may be located adjacent to and within 0.3 metres of a parking space in parking levels down to and including parking level P2 provided that the vertically-positioned bicycle parking space does not encroach into the parking space and such parking space is not considered to be obstructed in accordance with regulation 200.5.1.10(2)(D) provided that no portion of the adjacent stacked bicycle parking space exceeds a horizontal clearance from the wall of 1.2 metres

  17. Rule Q

    Regulation 230.5.1.10(9) with respect to the location of long term bicycle parking spaces does not apply

  18. Rule R

    Regulation 230.40.1.20(2) with respect to the location of short term bicycle parking spaces does not apply

  19. Rule S

    Section 600.10 with respect to Building Setback Overlay District "A", does not apply

  20. Rule T

    Despite clauses 40.5.40.70, 40.10.40.70, and 40.10.40.80, the required minimum building setbacks and minimum distance between main walls are shown in metres on Diagram 3 of By-law 518-2021

  21. Rule U

    Regulation 40.10.40.1(2) with respect to Commercial Uses – Location and First Floor Elevation shall not apply

  22. Rule V

    Regulation 40.10.40.10 with respect to Minimum height of first storey shall not apply

  23. Rule W

    Regulation 40.10.100.10(1) with respect to Vehicle Access shall not apply

  24. Rule X

    Despite 40.5.1.10(3)(A)(ii), for the purposes of this by-law, the following definition shall apply; (i) Alternative Housing means dwelling units and ancillary spaces operated by a non-profit organization providing living accommodation

  25. Rule Y

    Despite regulation (X), Alternative Housing shall be located on the ground floor, mezzanine and second floor of the new building authorized by this by-law and within the lands municipally known as 244 Church Street as of the date of passing of By-law 518-2021

  26. Rule Z

    The provisions of this By-law respecting the height of any building or structure , including permitted exceptions, are subject to any further limitations as may be set out in a by-law passed under an agreement pursuant to Section 5.81 of the Aeronautics Act, R.S.C. 1985, c A-2.

By-law 569-2013, Chapter 900

Lot facts

Area
1,254 m²
Frontage
35.8 m
Depth
39 m
Street
Dundas St E
Corner lot
Yes, also on Church St39 m along it
Public lane
Ln W Church S Dundas, 30.4 m along it
Max height
—
Max lot coverage
—
  • Major Transit Station Area: Dundas. The lot is inside the Dundas Major Transit Station Area approved by the Province (Site and Area Specific Policy 604). Source
  • Downtown Plan Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
  • Priority retail street: Church Street, Dundas Street East. The lot is on a priority retail street. In this zone at least 60% of the ground floor along that street must hold retail, restaurants, offices or similar uses, with entrances within 5 m of the lot line and 60% of the ground floor wall in windows or doors. Source
  • Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
  • Zone CR 4.0 (c2.0; r4.0) SS1 (x311) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source

Around this lot

Minor variances approved
95%21 of 22 decisions
Garden suite permits
0
Laneway suite permits
0
Multiplex permits
13
Development applications
40

Within 300 m, last 10 years. 13 suite and multiplex permits: more than at 80% of Toronto houses (median 3). 22 variance decisions: more than at 53% of Toronto houses (median 19).

Recent variance decisions in the same zone

  • Minor varianceApproved

    To permit a new eating establishment with karaoke rooms on the second storey (with an increased total floor area), and an eating establishment on the ground floor with washrooms and storage located in the basement, within the existing two-storey commercial building.

    332 YONGE ST · Oct 14, 2026 · 376 m away
  • Minor varianceApproved

    To alter the development standards (as approved under Site Specific Zoning By-law 1334-2023(OLT)) for the 44-storey mixed-use building, by increasing the overall height of the building (from 133.2 m to 134.75 m measured to the top of the mechanical penthouse) and height of the podium (from 30 m to 30.5 m), reducing the setbacks, and reducing the first storey building frontage abutting the priority retail street (Dundas Steet East). There will be a total of 542 residential dwelling units on this lot. A Site Plan Control application (File Number 21 218559 STE 13 SA) is currently under review.

    212 DUNDAS ST E · Jul 15, 2026 · 362 m away
  • Minor varianceApproved

    To construct a commercial parking lot (surface parking facility), which will contain 13 parking spaces (including one accessible parking space), with vehicular access from Harbour Light Lane. The existing two-storey non-residential building (located at 134 Jarvis Street) will be demolished.

    134 JARVIS ST · Nov 12, 2025 · 354 m away
  • Minor varianceApproved

    To alter the existing two-and-one-half-storey semi-detached building by increasing the non-residential floor space index.

    53 A MUTUAL ST · Oct 1, 2025 · 214 m away
  • Minor varianceApproved

    To alter the existing two-and-one-half-storey attached building by increasing the non-residential floor space index.

    53 MUTUAL ST · Oct 1, 2025 · 225 m away

Latest activity nearby

  • Building permit

    Proposal to install a maglock and access control system on the 8th-floor door.

    30 BOND ST · Nov 25, 2026 · 283 m away
  • Building permit

    Proposal to replace existing pre-action system fire control panel and associated initiating field devices.

    30 BOND ST · Nov 19, 2026 · 283 m away
  • Zoning review

    Not Started

    21 DUNDAS SQ · Nov 6, 2026 · 196 m away
  • Building permit

    Sprinklers related to 25-195702 BLD

    30 BOND ST · Nov 2, 2026 · 283 m away
  • Zoning review

    Closed

    78 MUTUAL ST · Oct 28, 2026 · 154 m away
  • Zoning review

    Closed

    1 DUNDAS ST E · Oct 26, 2026 · 248 m away
  • Zoning review

    Not Started

    207 JARVIS ST · Oct 21, 2026 · 292 m away
  • Building permit

    Proposal for replacement of existing 1-1/2" Watts 375XL reduced pressure (RP) backflow prevention device serving existing high-rise condominium building. Device located in PH mechanical room.

    181 DUNDAS ST E · Oct 8, 2026 · 276 m away
  • Building permit

    1 wall sign + 1 projecting sign**EGGSLUT**

    10 DUNDAS ST E · Oct 6, 2026 · 274 m away
  • Building permit

    Proposed project consists of security system upgrades including CCTV coverage throughout both exit stairwells and around the building perimeter, along with access control upgrades at stairwell and crossover floor doors.

    65 DUNDAS ST E · Oct 6, 2026 · 90 m away

Neighbourhood: Downtown Yonge East

About the area around the lot, not the lot itself.

Nearest station
TMU Station4 min walk
Nearest TTC stop
Dundas St East at Church St1 min walk
Nearest cycling route
Shuter StCycle Track, 3 min walk
Nearest traffic count
19,561 vehicles in 14 hDundas St E / Church St, 40 m away, Oct 15, 2025
Serious collisions within 500 m
192021–2026, killed or seriously injured: 1 fatal, 11 with pedestrians, 4 with cyclists
Parks
Arena Gardens2 min walk
Toronto Metropolitan University Square3 min walk
45 Dalhousie St Park4 min walk

Schools within 1 km

  • ST MICHAEL'S CHOIR SCHOOL - SECONDARY English Separate 1 min walk
  • ST MICHAEL'S CHOIR SCHOOL - ELEMENTARY English Separate 1 min walk
  • ST MICHAEL'S CHOIR SCHOOL - CHORAL BLDG English Separate 2 min walk
  • TORONTO METROPOLITAN UNIVERSITY - SCHOOL OF INTERIOR DESIGN University 2 min walk
  • ST MICHAEL'S CHOIR SCHOOL - GYMNASIUM BLDG English Separate 3 min walk
  • TMU - HEIDELBERG CENTRE SCHOOL OF GRAPHIC COMM'NS MGMT University 3 min walk

Being near a school does not mean the lot is in its catchment; check with the board.

2021 Census

FigureDowntown Yonge EastMedian neighbourhood
Median household income (2020)$69,500$84,500
Households that own their home36%54%
Population (2021)17,70016,813
Homes built in 1960 or before7%29%
Homes needing major repairs4%7%

Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.

Police-reported crime, 2025

Per 100,000 peopleDowntown Yonge EastCity median
Assault2360.8636.3
Robbery143.369.5
Shootings11.910.5
Auto theft75.6192.6
Theft over $5,00099.546.1
Break and enter274.7172.8
Theft from vehicles390.1188.1

Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.

Something here not right?

Sources

  • Building permits on this lot since 2000: Permits issued or applied for since about 2000, with status.
  • Committee of Adjustment files since 2001: Minor variances and consents (lot splits) on this lot and nearby, with decisions.
  • Development applications: Rezoning, site plan, subdivision and condominium applications.
  • Preliminary zoning reviews: Zoning reviews requested before a permit or variance application.
  • Zoning and overlays: Zoning By-law 569-2013 zone, height, coverage, policy area, parking, rooming house, priority retail street and downtown setback overlays.
  • Lot boundary, street and lane: Lot polygon, its addresses, the street it fronts, corner and public lane contact, with frontage and depth measured from the boundary; City of Toronto land in City use, which is not a home.
  • House and yards: Footprint and roof height of the house and other buildings, and the yard behind the house, from the City's 3D Massing (updated yearly, illustrative).
  • City trees in front of the lot: City-owned trees on the street allowance at this address, with species and trunk diameter. Private trees on the lot are not in open data.
  • Heritage: Heritage Register (listed and designated properties), Official Plan Amendment 720 properties and properties removed from the Register under the 2022 two-year limit.
  • TRCA regulated area: Valleys, floodplains, shorelines and wetlands regulated by the Toronto and Region Conservation Authority.
  • Ravines and natural features: Ravine and Natural Feature Protection area (Chapter 658, map last published 2019), Natural Heritage System and Environmentally Significant Areas.
  • Official Plan policies: Site and Area Specific Policies, Secondary Plans and Major Transit Station Areas covering the lot.
  • Rooming houses, short-term rentals and rental buildings: Multi-tenant house licences, short-term rental registrations and RentSafeTO evaluations at this address.
  • Neighbourhood context: Neighbourhood, 2021 Census figures, police-reported crime rates, schools, parks, TTC stops, cycling routes, serious collisions and traffic counts nearby. Area context only, not a finding about the lot.
  • Orders and by-law investigations: Outstanding Toronto Building orders, and by-law investigations open now or closed in the last two years. Fire and Public Health orders and older closed files are not published.
  • Address points: loaded Nov 29, 2026, published Nov 27, 2026
  • Toronto Building orders: loaded Nov 28, 2026, published Nov 27, 2026
  • Neighbourhood Profiles, 2021 Census: loaded Oct 14, 2026, published Oct 6, 2023
  • Street centrelines: loaded Nov 29, 2026, published Nov 27, 2026
  • City-owned land: loaded Nov 29, 2026, published Nov 23, 2026
  • Committee of Adjustment open applications: loaded Nov 29, 2026, published Nov 28, 2026
  • Committee of Adjustment decisions: loaded Nov 29, 2026, published Nov 28, 2026
  • Committee of Adjustment decisions 2001-2016: loaded Oct 14, 2026, published Feb 20, 2026
  • Collisions with people killed or seriously injured (Toronto Police Service): loaded Nov 29, 2026, published Nov 28, 2026
  • Neighbourhood crime rates (Toronto Police Service): loaded Oct 14, 2026, published Feb 20, 2026
  • Cycling network: loaded Nov 22, 2026, published Nov 16, 2026
  • Development applications: loaded Nov 29, 2026, published Nov 29, 2026
  • Environmentally Significant Areas: loaded Oct 14, 2026, published Mar 16, 2026
  • Green spaces: loaded Nov 29, 2026, published Nov 24, 2026
  • Heritage register: loaded Oct 14, 2026, published Sep 1, 2026
  • Former heritage listings: loaded Oct 14, 2026, published Jul 3, 2025
  • Official Plan Amendment 720 heritage list: loaded Nov 29, 2026, published Nov 23, 2026
  • 3D Massing building footprints: loaded Oct 14, 2026, published Dec 2, 2025
  • By-law investigation addresses: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigation deficiencies: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigations: loaded Nov 29, 2026, published Nov 28, 2026
  • Major Transit Station Areas: loaded Oct 14, 2026, published Feb 3, 2026
  • Natural Heritage System: loaded Oct 14, 2026, published Mar 16, 2026
  • Neighbourhoods: loaded Oct 14, 2026, published Feb 20, 2026
  • Property boundaries: loaded Nov 27, 2026, published Nov 27, 2026
  • Active building permits: loaded Nov 29, 2026, published Nov 28, 2026
  • Cleared building permits: loaded Nov 29, 2026, published Nov 28, 2026
  • Cleared building permits 2000-2016: loaded Oct 14, 2026, published Jul 8, 2025
  • Preliminary zoning reviews: loaded Nov 29, 2026, published Nov 28, 2026
  • Ravine and natural feature protection: loaded Oct 14, 2026, published Jul 23, 2019
  • RentSafeTO evaluations: loaded Nov 29, 2026, published Nov 28, 2026
  • Multi-tenant house licences: loaded Nov 29, 2026, published Nov 28, 2026
  • Site and Area Specific Policies: loaded Oct 14, 2026, published Mar 16, 2026
  • School locations: loaded Oct 14, 2026, published May 27, 2026
  • Secondary Plans: loaded Oct 14, 2026, published Mar 16, 2026
  • Street trees: loaded Nov 29, 2026, published Nov 23, 2026
  • Short-term rental registrations: loaded Nov 29, 2026, published Nov 28, 2026
  • Traffic counts at intersections: loaded Nov 29, 2026, published Nov 28, 2026
  • TRCA regulation limit: loaded Oct 14, 2026, published Apr 29, 2026
  • TTC stops (GTFS): loaded Nov 8, 2026, published Nov 5, 2026
  • Zoning by-law: loaded Nov 29, 2026, published Nov 23, 2026
  • Lot coverage overlay: loaded Nov 29, 2026, published Nov 23, 2026
  • Height overlay: loaded Nov 29, 2026, published Nov 23, 2026
  • Parking zone overlay: loaded Nov 29, 2026, published Nov 23, 2026
  • Policy area overlay: loaded Nov 29, 2026, published Nov 23, 2026
  • Priority retail streets: loaded Nov 29, 2026, published Nov 23, 2026
  • Rooming house overlay: loaded Nov 29, 2026, published Nov 23, 2026
  • Zoning setbacks: loaded Nov 29, 2026, published Nov 23, 2026

Contains information licensed under the Open Government Licence – Toronto. TRCA regulation limit © TRCA.

Screening tool based on City of Toronto and TRCA open data. Not a zoning review or legal opinion. Site-specific exceptions, amendments not yet in the open data, minor variances and other by-laws can change the answer. Confirm with a Preliminary Project Review or Zoning Certificate from Toronto Building before buying or designing.