16 by-law investigations closed in the last two years
Good to knowClosed files (Adequate Heat, Notice Issued Adequate Heat, Order Issued Property Standards, Property Standards, Zoning): 26 262472 HEA 00 IR (Adequate Heat, 2026); 26 258913 ZON 00 IR (Zoning, 2026); 26 234882 HEA 00 IR (Adequate Heat, 2026); and 13 more.
What it means. Someone raised an issue here and the City closed the file. Ask the seller what it was about.
City of Toronto, Toronto Building orders and Municipal Licensing and Standards investigationsWork or applications in progress
Good to knowRecent records on this lot: 21 221001 STE 13 SB (Draft Plan of Subdivision to create 2 development blocks, 2021); 21 166615 STE 13 SA (Site Plan Approval for two mixed-use towers having heights of 54 and 59-storeys, 2021).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications2 Committee of Adjustment files on this lot
Good to know1 approved. A0053/26TEY (To alter the development standards, as approved under Site Specific Zoning By-law 596-2..., 2026); A0656/03TEY (The applicant is seeking relief from the provisions of the Zoning By-law in order to ma..., 2004).
What it means. Approved variances and consents stay with the property, including any conditions in the decision. They allow what was approved, not more.
How to confirm. Decisions are in the Application Information Centre; older files are available from the Committee of Adjustment office. Details
City of Toronto, Committee of Adjustment applications (2001 onwards)17 development applications open within 300 m
Good to know17 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 94 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development ApplicationsRental building evaluation: 96 out of 100
Good to knowThe City's RentSafeTO program evaluated this rental building in 2026 (25 storeys, 260 units, built 1965).
What it means. The score covers common areas, building systems and records. Read the evaluation details for the items that scored low.
How to confirm. The City's RentSafeTO page has the evaluation results and any open orders for the building. Details
City of Toronto, RentSafeTO Apartment Building Evaluations
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
34 records on file: more than at 100% of Toronto houses (median 0).
- By-law investigation26 262472 HEA 00 IRClosed
Adequate Heat
Oct 29, 2026 · 25 ST MARY ST - By-law investigation26 258913 ZON 00 IRClosed
Zoning
Oct 22, 2026 · 25 ST MARY ST - By-law investigation26 234882 HEA 00 IRClosed
Adequate Heat
Sep 9, 2026 · 25 ST MARY ST - By-law investigation26 172137 000 00 IRClosed
Adequate Heat
Jun 1, 2026 · 25 ST MARY ST - By-law investigation26 172136 000 00 IRClosed
Property Standards
Jun 1, 2026 · 25 ST MARY ST - By-law investigation26 114372 PRS 00 IVClosed
Order Issued Property Standards: The dwelling does not have a heating system capable of maintaining a room temperature of twenty-one degrees Celsius(21?C).; The heating units are not in good repair and maintained in good working condition, specifically, the radiator units within bedrooms are non-functional.
Feb 6, 2026 · 25 ST MARY ST - By-law investigation26 114356 PRS 00 IRClosed
Property Standards
Feb 6, 2026 · 25 ST MARY ST - By-law investigation26 113242 HEA 00 IVClosed
Notice Issued Adequate Heat: The heat supplied to the dwelling unit is below twenty-one (21) degrees Celsius.
Feb 2, 2026 · 25 ST MARY ST
Show 26 older records
- By-law investigation26 111666 HEA 00 IRClosed
Adequate Heat
Feb 2, 2026 · 25 ST MARY ST - Minor varianceA0053/26TEYPending
To alter the development standards, as approved under Site Specific Zoning By-law 596-2023, for the existing 24-storey mixed-use building to modify the building setbacks and to reduce the indoor amenity provisions. This is currently under the review of Site Plan Control (File No. 21 166615 STE 13 SA). There will be a total of 1,024 residential dwelling units on this lot with retail and a daycare facility on the ground floor.
Jan 20, 2026 · 25 ST MARY ST - By-law investigation25 263487 HEA 00 IRClosed
Adequate Heat
Dec 7, 2025 · 25 ST MARY ST - Building permit25 244565Closed
Proposed install additional smoke detectors in the corridor on all floors
Nov 17, 2025 · 25 ST MARY ST - Zoning review25 250867 ZAPNotice SentNov 7, 2025 · 25 ST MARY ST
- By-law investigation25 179718 PRS 00 IRClosed
Property Standards
Jun 18, 2025 · 25 ST MARY ST - By-law investigation25 173517 PRS 00 IRClosed
Property Standards
Jun 7, 2025 · 25 ST MARY ST - By-law investigation25 160378 PRS 00 IRClosed
Property Standards
May 15, 2025 · 25 ST MARY ST - By-law investigation25 137073 PRS 00 IRClosed
Property Standards
Mar 31, 2025 · 25 ST MARY ST - By-law investigation25 100727 PRS 00 IRClosed
Property Standards
Jan 3, 2025 · 25 ST MARY ST - By-law investigation24 252861 HEA 00 IRClosed
Adequate Heat
Dec 22, 2024 · 25 ST MARY ST - Zoning review22 160045 ZAPClosedJun 10, 2022 · 25 ST MARY ST
- Development application21 221001 STE 13 SBUnder Review
Draft Plan of Subdivision to create 2 development blocks.
Oct 3, 2021 · 25 ST MARY ST · City file - Zoning review21 166606 POZClosedJun 11, 2021 · 25 ST MARY ST
- Development application21 166615 STE 13 SAUnder Review
Site Plan Approval for two mixed-use towers having heights of 54 and 59-storeys.
Jun 7, 2021 · 25 ST MARY ST · City file - Development application21 166606 STE 13 OZClosed
Official Plan and Zoning By-law Amendment application for two mixed-use towers having heights of 54 and 59 storeys.
Jun 7, 2021 · 25 ST MARY ST · City file - Zoning review19 157098 LPRClosedMay 21, 2019 · 25 ST MARY ST
- Building permit18 114497Closed
Proposal to remove window frame and brick masonry and replace wit a new window and metal door
Feb 16, 2018 · 25 ST MARY ST - Building permit09 185849Closed
Proposal to install one backflow prevention device
Nov 9, 2009 · 25 ST MARY ST - Building permit08 183828Closed
Removal of a swimming pool and erection of a parking lot.
Aug 15, 2008 · 25 ST MARY ST - Building permit08 178359Closed
Proposal to repair and reclad exterior walls of existing apartment building (1920m2).
Jul 24, 2008 · 25 ST MARY ST - Building permit08 156832Closed
Proposal to install 2 electromagnetic locks in cnnection to existing fire alarm system on garage level 1, and garage level 2 (sub garage) to existing apartment building.
May 28, 2008 · 25 ST MARY ST - Minor varianceA0656/03TEYApproved
The applicant is seeking relief from the provisions of the Zoning By-law in order to make concrete repairs to the exterior walls and erect new metal enclosures approximately 2.5 metres in height over the three existing stairwells leading from the underground parking garage of the existing apartment building.
Jan 21, 2004 · 25 ST MARY ST - Building permit03 127724Cancelled
Make minor concrete repairs to wall and construct stairwell enclosures. Jan. 21/05 No response to notice, File Closed
Apr 29, 2003 · 25 ST MARY ST - Building permit02 137513Closed
Replace windows in front & rear elevation.
Jun 13, 2002 · 25 ST MARY ST - Building permit98 023359Closed
CARRY OUT REMEDIAL WORK TO COMPLY WITH THE RETROFIT PRIVISIONS OF THE FIRE CODE. (FIRE ALARM) EDC
Nov 3, 1998 · 25 ST MARY ST
Check before you build
Site-specific exception 900.11.10(857)
Needs a closer look27 site-specific rules and 27 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
On 25 St. Mary Street, if the requirements of By-law 596-2023 are complied with, a building or structure may be constructed, used or enlarged in compliance with Regulations
- Rule B
to (FF) below; (B) Despite Regulations 40.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum of 113.5 metres and the elevation of the highest point of the building or structure
- Rule C
In addition to the uses permitted in Regulation 40.10.20.10(1) a "geo-energy facility" is permitted
- Rule D
Despite Regulation 40.10.20.20(1)(A), an outdoor patio is not subject to Regulation 40.10.20.100(21)(A),(D), and (F)
- Rule E
Despite Regulation 40.10.20.100(33), 150.100.20.1(1)(A) there is no maximum interior floor area for the uses noted in 150.100.20.1(1)(A)(vi)
- Rule F
Despite Regulation 40.10.20.40(1), dwelling units are permitted in an apartment building or mixed - use building on the lot
- Rule G
Despite Regulation 40.10.40.1(1), residential use portions of the building are permitted to be located on the same storey or below non-residential use portions of the building
- Rule H
For the purposes of this exception, a mezzanine does not constitute a storey
- Rule I
Despite Regulation 40.10.40.10(1), the permitted maximum height of a building or structure is the number in metres following the letters "HT" as shown on Diagram 3 of By-law 596-2023
- Rule J
Despite Regulations 40.5.40.10 (3), (4), (5)(B), (6), (7) and (8) and (I) above, the following equipment and structures may project beyond the permitted maximum height shown on Diagram 3 of By-law 596-2023: (i) Elements on or above any roof used for elevator-related structural elements and elevator shafts, cooling towers, antennae, and building maintenance units by a maximum of 5.0 metres; (ii) Elements on or above any roof used for chimneys, pipes, flues, stacks, vents, enclosed stairwells, renewable energy facilities and devices, window washing equipment, and roof access by a maximum of 3.0 metres; (iii) Elements on or above any roof used for ornamental or architectural features, parapets and elements, by a maximum of 3.0 metres; (iv) structures that enclose, screen or cover the equipment, structures and parts of a building listed in (i) and (ii) above, by a maximum of 3.0 metres; (v) Elements on or above any roof used for lightning rods by a maximum of 5.0 metres; (vi) structures associated with a green roof by a maximum of 3.0 metres; (vii) trellises, pergolas, louvres associated with rooftop amenity space and day nursery outdoor space, and unenclosed structures providing safety or wind protection to rooftop amenity space and day nursery outdoor space by a maximum of 6.0 metres; and (viii) planters, landscaping features, guard rails, and divider screens on a balcony and/or terrace by a maximum of 3.0 metres
- Rule K
Despite (I) above, no part of a building , except for any structural elements and associated cladding, may be located between the Canadian Geodetic Datum elevation of 113.5 metres and: (i) a minimum vertical clearance of 3.0 metres in the shaded area on Diagram 3 of By-law 596-2023; and (ii) a minimum vertical clearance of 9.0 metres in the hatched area on Diagram 3 of By-law 596-2023
- Rule L
Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area of all buildings and structures on the lot is 85,600 square metres, subject to the following: (i) the required minimum gross floor area for non-residential uses is 1,010 square metres, of which: (a) the required minimum interior floor area for a day nursery is 710 square metres
- Rule M
Despite Regulation 150.45.40.1(1), a day nursery use may be located on the first or second storey of a building
- Rule N
In addition to the elements listed in Regulation 40.5.40.40(3), the gross floor area of a building may also be reduced by the following areas: (i) storage rooms, washrooms, electrical, utility, service corridors, mechanical and ventilation rooms, moving rooms, mail / parcel room, bicycle parking, firefighter central alarm control facilities (CACF), below-ground at, or above-ground; and (ii) indoor amenity space to a maximum of 2.25 square meters per dwelling unit
- Rule O
Despite Regulation 40.10.40.50(1) and (2), a building with 20 or more dwelling units must provide amenity space on the lot at the following rate: (i) at least 2.25 square metres for each dwelling unit as indoor amenity space ; (ii) at least 1.25 square metres of outdoor amenity space for each dwelling unit ; (iii) a maximum of 0.5 square metres per dwelling unit of indoor amenity space may be located below-ground; and (iv) no more than 25 percent of the outdoor component may be a green roof
- Rule P
Despite Regulation 40.5.40.70(1), 40.10.40.70(1), and Article 600.10.10 the required minimum building setbacks are as shown in metres on Diagram 3 of By-law 596-2023
- Rule Q
Despite Regulation 40.10.40.80(1), the required separation of main walls are as shown in metres on Diagram 3 of By-law 596-2023
- Rule R
Despite Clause 40.10.40.60, (P) and (Q) above, the following elements may encroach into the required minimum building setbacks and main wall separation distances as follows: (i) Balconies may encroach a maximum of 1.5 metres provided they: (a) are not located on main walls of the West Building that are within 2.5 metres of the intersection of two main walls , as shown on Diagram 3 of By-law 596-2023, at and above 35.0 metres in height; (b) do not occupy more than 50 percent of the length of any main wall of the West Building as shown on Diagram 3 of By-law 596-2023 at and above 35.0 metres in height; (c) are not located on main walls of the East Building that are within 2.5 metres of an area of the East Building where two main wall adjoin, as shown on Diagram 3 of By- law 596-2023 at and above 22.0 metres in height; and (d) do not occupy more than 50 percent of the length of any main wall of the East Building as shown on Diagram 3 of By- law 596-2023 at and above 22.0 metres in height; (ii) exterior stairs, access ramps and elevating devices, by a maximum of 1.0 metre; (iii) cladding added to the exterior surface of the main wall of a building , by a maximum of 1.0 metre; (iv) architectural features, such as a pilaster, decorative column, cornice, sill, belt course, or chimney breast, by a maximum of 1 metre; (v) window projections, including bay windows and box windows, by a maximum of 1.0 metre; (vi) eaves, by a maximum of 1.0 metre; (vii) a dormer, by a maximum of 1.0 metre; (viii) air conditioners, satellite dishes, antennae, vents, and pipes, by a maximum of 1.0 metre; and (ix) canopies and awnings with or without support, (a) to the same extent as the platform it is covering; and (b) if it is not covering a platform, the canopy or similar structure to a maximum of 2.5 metres if it is no closer than 0 metres from a lot line
- Rule S
Despite Regulation 200.5.1.10(2)(A)(iv), a maximum of 20 percent of the required parking spaces may be obstructed as described in Regulation 200.5.1.10(2)(D) without being required to provide additional width for the obstructed sides of the parking space
- Rule T
Despite Regulation 200.5.1.10(2), a maximum of 20 percent of the total number of parking spaces may have the following minimum dimensions: (i) minimum width of 2.4 metres; (ii) minimum length of 5.4 metres; and (iii) minimum vertical clearance of 1.8 metres
- Rule U
Despite Regulations 200.5.1.10(2)(A) and (D), Electric Vehicle Infrastructure, including electric vehicle supply equipment, does not constitute an obstruction to a parking space
- Rule V
Despite Regulation 200.5.10.1(1), (4), (5), and (6), and Table 200.5.10.1, parking spaces must be provided in accordance with the following: (i) a minimum of 0 residential occupant parking spaces for each dwelling unit ; (ii) a minimum 2.0 parking spaces plus 0.01 parking spaces per dwelling unit for residential visitors (iii) a minimum 2.0 "car-share parking spaces"; (iv) a minimum of 1 parking spaces for the day nursery use; and (v) a minimum of 0 parking spaces for non-residential uses; (vi) for the purpose of this exception, "car-share" or "car-sharing" means the practice where a number of people share the use of one or more motor vehicles that are owned by a profit or non profit car- sharing organization and where such organization may require that use of motor vehicles be reserved in advance, charge fees based on time and/or kilometres driven, and set membership requirements of the car sharing organization, including the payment of a membership fee that may or may not be refundable; and (vii) for the purpose of this exception, "car-share parking space" means a parking space that is reserved and actively used for "car-sharing"
- Rule W
Despite Regulation 200.5.10.1(1) and Regulation (V)(ii), "car share parking spaces" may replace parking spaces otherwise required for visitors
- Rule X
Despite Regulations 200.15.10(1) and (2), a minimum of 2 of the required parking spaces on the lot must be accessible parking spaces
- Rule Y
Despite Regulations 220.5.10.1 (1), (2), (3), loading spaces must be provided as follows: (i) A minimum of 1 Type "G" loading space ; and (ii) A minimum of 1 Type "C" loading space
- Rule Z
Despite regulation 230.5.1.10(4)(A), the required minimum dimensions of a bicycle parking space is: (i) length of 1.7 metres; (ii) width of 0.3 metres; and (iii) vertical clearance of 1.9 metres
- Rule AA
An area used to provide bicycle parking spaces must have a minimum vertical clearance of 2.4 metres if it is a stacked bicycle parking space and 1.9 metres in all other cases; (BB) A bicycle parking space if placed in a vertical position on a wall, structure or mechanical device must have a minimum length or vertical clearance of 1.9 metres, minimum width of 0.4 metres, and minimum horizontal clearance from the wall of 1.2 metres; (CC) Despite Regulation 230.5.1.10(10), "short-term" bicycle parking spaces may also be located in a stacked bicycle parking space ; (DD) Despite Regulation 230.5.1, "short-term" bicycle parking spaces may be located below-ground, and at and above-ground up to and including the second storey ; (EE) The provision of dwelling units is subject to the following: (i) A minimum of 15 percent of the total number of dwelling units must contain two bedrooms; (ii) A minimum of 10 percent of the total number of dwelling units must contain three or more bedrooms; (iii) An additional 15 percent of the total number of dwelling units will be any combination of two bedroom and three bedroom dwelling units , or dwelling units that can be converted into any combination of two and three bedroom dwelling units ; (iv) Convertible dwelling units as described in (EE)(iii) above, may be converted using accessible or adaptable design measures, such as knockout panels; and (v) None of the above apply to rental replacement dwelling units provided in accordance with Section 111 of the Municipal Code (FF) For the purpose of this exception, a "geo-energy facility" means premises containing devices to generate geo - energy for the exclusive use of the building . Prevailing By-laws and Prevailing Sections: (None Apply)
- Older by-law A
On 25 St. Mary Street, if the requirements of By-law 596-2023 are complied with, a building or structure may be constructed, used or enlarged in compliance with Regulations
- Older by-law B
to (FF) below; (B) Despite Regulations 40.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum of 113.5 metres and the elevation of the highest point of the building or structure
- Older by-law C
In addition to the uses permitted in Regulation 40.10.20.10(1) a "geo-energy facility" is permitted
- Older by-law D
Despite Regulation 40.10.20.20(1)(A), an outdoor patio is not subject to Regulation 40.10.20.100(21)(A),(D), and (F)
- Older by-law E
Despite Regulation 40.10.20.100(33), 150.100.20.1(1)(A) there is no maximum interior floor area for the uses noted in 150.100.20.1(1)(A)(vi)
- Older by-law F
Despite Regulation 40.10.20.40(1), dwelling units are permitted in an apartment building or mixed - use building on the lot
- Older by-law G
Despite Regulation 40.10.40.1(1), residential use portions of the building are permitted to be located on the same storey or below non-residential use portions of the building
- Older by-law H
For the purposes of this exception, a mezzanine does not constitute a storey
- Older by-law I
Despite Regulation 40.10.40.10(1), the permitted maximum height of a building or structure is the number in metres following the letters "HT" as shown on Diagram 3 of By-law 596-2023
- Older by-law J
Despite Regulations 40.5.40.10 (3), (4), (5)(B), (6), (7) and (8) and (I) above, the following equipment and structures may project beyond the permitted maximum height shown on Diagram 3 of By-law 596-2023: (i) Elements on or above any roof used for elevator-related structural elements and elevator shafts, cooling towers, antennae, and building maintenance units by a maximum of 5.0 metres; (ii) Elements on or above any roof used for chimneys, pipes, flues, stacks, vents, enclosed stairwells, renewable energy facilities and devices, window washing equipment, and roof access by a maximum of 3.0 metres; (iii) Elements on or above any roof used for ornamental or architectural features, parapets and elements, by a maximum of 3.0 metres; (iv) structures that enclose, screen or cover the equipment, structures and parts of a building listed in (i) and (ii) above, by a maximum of 3.0 metres; (v) Elements on or above any roof used for lightning rods by a maximum of 5.0 metres; (vi) structures associated with a green roof by a maximum of 3.0 metres; (vii) trellises, pergolas, louvres associated with rooftop amenity space and day nursery outdoor space, and unenclosed structures providing safety or wind protection to rooftop amenity space and day nursery outdoor space by a maximum of 6.0 metres; and (viii) planters, landscaping features, guard rails, and divider screens on a balcony and/or terrace by a maximum of 3.0 metres
- Older by-law K
Despite (I) above, no part of a building , except for any structural elements and associated cladding, may be located between the Canadian Geodetic Datum elevation of 113.5 metres and: (i) a minimum vertical clearance of 3.0 metres in the shaded area on Diagram 3 of By-law 596-2023; and (ii) a minimum vertical clearance of 9.0 metres in the hatched area on Diagram 3 of By-law 596-2023
- Older by-law L
Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area of all buildings and structures on the lot is 85,600 square metres, subject to the following: (i) the required minimum gross floor area for non-residential uses is 1,010 square metres, of which: (a) the required minimum interior floor area for a day nursery is 710 square metres
- Older by-law M
Despite Regulation 150.45.40.1(1), a day nursery use may be located on the first or second storey of a building
- Older by-law N
In addition to the elements listed in Regulation 40.5.40.40(3), the gross floor area of a building may also be reduced by the following areas: (i) storage rooms, washrooms, electrical, utility, service corridors, mechanical and ventilation rooms, moving rooms, mail / parcel room, bicycle parking, firefighter central alarm control facilities (CACF), below-ground at, or above-ground; and (ii) indoor amenity space to a maximum of 2.25 square meters per dwelling unit
- Older by-law O
Despite Regulation 40.10.40.50(1) and (2), a building with 20 or more dwelling units must provide amenity space on the lot at the following rate: (i) at least 2.25 square metres for each dwelling unit as indoor amenity space ; (ii) at least 1.25 square metres of outdoor amenity space for each dwelling unit ; (iii) a maximum of 0.5 square metres per dwelling unit of indoor amenity space may be located below-ground; and (iv) no more than 25 percent of the outdoor component may be a green roof
- Older by-law P
Despite Regulation 40.5.40.70(1), 40.10.40.70(1), and Article 600.10.10 the required minimum building setbacks are as shown in metres on Diagram 3 of By-law 596-2023
- Older by-law Q
Despite Regulation 40.10.40.80(1), the required separation of main walls are as shown in metres on Diagram 3 of By-law 596-2023
- Older by-law R
Despite Clause 40.10.40.60, (P) and (Q) above, the following elements may encroach into the required minimum building setbacks and main wall separation distances as follows: (i) Balconies may encroach a maximum of 1.5 metres provided they: (a) are not located on main walls of the West Building that are within 2.5 metres of the intersection of two main walls , as shown on Diagram 3 of By-law 596-2023, at and above 35.0 metres in height; (b) do not occupy more than 50 percent of the length of any main wall of the West Building as shown on Diagram 3 of By-law 596-2023 at and above 35.0 metres in height; (c) are not located on main walls of the East Building that are within 2.5 metres of an area of the East Building where two main wall adjoin, as shown on Diagram 3 of By- law 596-2023 at and above 22.0 metres in height; and (d) do not occupy more than 50 percent of the length of any main wall of the East Building as shown on Diagram 3 of By- law 596-2023 at and above 22.0 metres in height; (ii) exterior stairs, access ramps and elevating devices, by a maximum of 1.0 metre; (iii) cladding added to the exterior surface of the main wall of a building , by a maximum of 1.0 metre; (iv) architectural features, such as a pilaster, decorative column, cornice, sill, belt course, or chimney breast, by a maximum of 1 metre; (v) window projections, including bay windows and box windows, by a maximum of 1.0 metre; (vi) eaves, by a maximum of 1.0 metre; (vii) a dormer, by a maximum of 1.0 metre; (viii) air conditioners, satellite dishes, antennae, vents, and pipes, by a maximum of 1.0 metre; and (ix) canopies and awnings with or without support, (a) to the same extent as the platform it is covering; and (b) if it is not covering a platform, the canopy or similar structure to a maximum of 2.5 metres if it is no closer than 0 metres from a lot line
- Older by-law S
Despite Regulation 200.5.1.10(2)(A)(iv), a maximum of 20 percent of the required parking spaces may be obstructed as described in Regulation 200.5.1.10(2)(D) without being required to provide additional width for the obstructed sides of the parking space
- Older by-law T
Despite Regulation 200.5.1.10(2), a maximum of 20 percent of the total number of parking spaces may have the following minimum dimensions: (i) minimum width of 2.4 metres; (ii) minimum length of 5.4 metres; and (iii) minimum vertical clearance of 1.8 metres
- Older by-law U
Despite Regulations 200.5.1.10(2)(A) and (D), Electric Vehicle Infrastructure, including electric vehicle supply equipment, does not constitute an obstruction to a parking space
- Older by-law V
Despite Regulation 200.5.10.1(1), (4), (5), and (6), and Table 200.5.10.1, parking spaces must be provided in accordance with the following: (i) a minimum of 0 residential occupant parking spaces for each dwelling unit ; (ii) a minimum 2.0 parking spaces plus 0.01 parking spaces per dwelling unit for residential visitors (iii) a minimum 2.0 "car-share parking spaces"; (iv) a minimum of 1 parking spaces for the day nursery use; and (v) a minimum of 0 parking spaces for non-residential uses; (vi) for the purpose of this exception, "car-share" or "car-sharing" means the practice where a number of people share the use of one or more motor vehicles that are owned by a profit or non profit car- sharing organization and where such organization may require that use of motor vehicles be reserved in advance, charge fees based on time and/or kilometres driven, and set membership requirements of the car sharing organization, including the payment of a membership fee that may or may not be refundable; and (vii) for the purpose of this exception, "car-share parking space" means a parking space that is reserved and actively used for "car-sharing"
- Older by-law W
Despite Regulation 200.5.10.1(1) and Regulation (V)(ii), "car share parking spaces" may replace parking spaces otherwise required for visitors
- Older by-law X
Despite Regulations 200.15.10(1) and (2), a minimum of 2 of the required parking spaces on the lot must be accessible parking spaces
- Older by-law Y
Despite Regulations 220.5.10.1 (1), (2), (3), loading spaces must be provided as follows: (i) A minimum of 1 Type "G" loading space ; and (ii) A minimum of 1 Type "C" loading space
- Older by-law Z
Despite regulation 230.5.1.10(4)(A), the required minimum dimensions of a bicycle parking space is: (i) length of 1.7 metres; (ii) width of 0.3 metres; and (iii) vertical clearance of 1.9 metres
- Older by-law AA
An area used to provide bicycle parking spaces must have a minimum vertical clearance of 2.4 metres if it is a stacked bicycle parking space and 1.9 metres in all other cases; (BB) A bicycle parking space if placed in a vertical position on a wall, structure or mechanical device must have a minimum length or vertical clearance of 1.9 metres, minimum width of 0.4 metres, and minimum horizontal clearance from the wall of 1.2 metres; (CC) Despite Regulation 230.5.1.10(10), "short-term" bicycle parking spaces may also be located in a stacked bicycle parking space ; (DD) Despite Regulation 230.5.1, "short-term" bicycle parking spaces may be located below-ground, and at and above-ground up to and including the second storey ; (EE) The provision of dwelling units is subject to the following: (i) A minimum of 15 percent of the total number of dwelling units must contain two bedrooms; (ii) A minimum of 10 percent of the total number of dwelling units must contain three or more bedrooms; (iii) An additional 15 percent of the total number of dwelling units will be any combination of two bedroom and three bedroom dwelling units , or dwelling units that can be converted into any combination of two and three bedroom dwelling units ; (iv) Convertible dwelling units as described in (EE)(iii) above, may be converted using accessible or adaptable design measures, such as knockout panels; and (v) None of the above apply to rental replacement dwelling units provided in accordance with Section 111 of the Municipal Code (FF) For the purpose of this exception, a "geo-energy facility" means premises containing devices to generate geo - energy for the exclusive use of the building . Prevailing By-laws and Prevailing Sections: (None Apply)
Lot facts
- Area
- 5,204 m²
- Frontage
- 61.7 m
- Depth
- 93.6 m
- Street
- St Nicholas St
- Corner lot
- Yes, also on St Mary St93.6 m along it
- Public lane
- Ln E Bay N Inkerman, 53.8 m along it
- House footprint
- 993 m²roof up to 81.5 m
- Back yard
- 26 mhouse to rear lot line
- Side yards
- 15.6 m and 16.7 mhouse to side lot lines
- Buildings on the lot
- 2house, garage, sheds
- Max height
- 18 m
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
- Site and Area Specific Policy 382. The Official Plan has a policy for this site or area that varies the general rules. Read it before relying on zoning alone. Source
- Major Transit Station Area: Bloor-Yonge. The lot is inside the Bloor-Yonge Major Transit Station Area approved by the Province (Site and Area Specific Policy 600). Source
- Downtown Plan Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
- Zone CR 4.0 (c1.0; r4.0) SS1 (x857) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
- 6 City trees in front of this lot. The City's street tree inventory lists 6 trees at this address: maple, norway (40 cm), honey locust (36 cm), ash, green (22 cm). Diameter is the trunk at breast height. Source
Around this lot
- Minor variances approved
- 96%26 of 27 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 0
- Development applications
- 35
Within 300 m, last 10 years. 0 suite and multiplex permits: no more than at most Toronto houses (median 3). 27 variance decisions: more than at 59% of Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To alter the development standards for the mixed-use development (approved a northern building height of 35-storeys (124.5 m) under Site Specific Zoning By-law 302-2023), and increased to 39-storeys (135.5 m as approved under Minor Variance Decision A0018/24TEY), by further increasing the northern building height to 44-storeys (142.75 m, excluding the mechanical penthouse) inclusive of an 11-storey podium base building (38.65 m), increasing the maximum gross floor area, residential gross floor area, and reducing the outdoor amenity spaces. Also, the existing 10-storey office building (located at the southern limits of this subject site) will be maintained and unaltered. There will be a total of 329 residential dwelling units on this lot.
1235 BAY ST · Oct 14, 2026 · 437 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 1050-2015) for the 68-storey mixed-use building (north-east Tower) by increasing the building height from 215 m to 218.6 m (including the height of the mechanical penthouse). Also, to reduce the total number of commercial parking spaces (managed by the Toronto Parking Authority) from 800 to 795 within Parking Levels 1 to 6 (with five parking spaces located on the south-east portion of Parking Level 6 being converted into car wash bays). The existing 196 residential parking spaces on Parking Levels 3 and 4 will be maintained and unaltered.
27-29 YORKVILLE AVE · Jul 15, 2026 · 459 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 88-2023(OLT)) for the 40-storey mixed-use building (which is currently under construction), by increasing the residential gross floor area, building height (41-storeys; 123.5 m to 127.6 m and 129.2 m to 133.6 m), and the height of the elevator overrun projection. There will be a total of 516 residential dwelling units on this site.
20 MAITLAND ST · Apr 1, 2026 · 478 m away - Minor varianceApproved
To alter the development standards for the 40-storey mixed-use building (as approved under Site Specific Zoning By-law 88-2023) by increasing the total number of residential dwelling units, the overall and residential gross floor area, the building height, and the maximum projection height of an elevator overrun. Also, to reduce the total number of residential dwelling units with 3 or more bedrooms, the required amenity space, and the total number of residential visitor parking spaces. The new 45-storey mixed-use building (excluding the mechanical penthouse) will have a total of 572 residential dwelling units, 78 residential parking spaces, and 7 residential visitor parking spaces. This is currently undergoing Site Plan Control (Application Number 19 240163 STE 13 SA).
26 MAITLAND ST · Apr 23, 2025 · 485 m away - Minor varianceApproved
To alter the development standards for the site (as approved under Site Specific Zoning By-law 778-2016(OMB)), for the existing 44-storey mixed-use building, by constructing mezzanine space. Also, to convert the existing two-and-one-half-storey townhouses (located at the northeast corner on this lot, municipally known as 7 and 9 Gloucester Street) into mixed-use buildings, and to increase the non-residential gross floor areas.
593 YONGE ST · Nov 27, 2024 · 239 m away
Latest activity nearby
- Zoning review
Application Acceptable
95 ST JOSEPH ST · Nov 24, 2026 · 264 m away - Zoning review
Application On Hold
649 YONGE ST · Nov 23, 2026 · 160 m away - Building permit
One wall sign.***SIGNATURE HAIR STUDIO***
665 YONGE ST · Nov 18, 2026 · 166 m away - Building permit
Proposed Hydro Vault Repairs
1001 BAY ST · Nov 13, 2026 · 210 m away - Building permit
1 Wall Sign*****RUDSAK******
55 BLOOR ST W · Nov 10, 2026 · 279 m away - Building permit
Proposed interior alteration at second, third, fifth and sixth floor to convert the property from office building to mixed-use building; Proposed: 10 residential units, 1 wellness studio and 5 officesExisting: 1 wellness studio at first floor and 1 office at fourth floor
9 ST NICHOLAS ST · Nov 9, 2026 · 277 m away - Building permit
Proposal to convert the second floor of Da.Si.Mar Shawarma into a coffee shop with a maximum seating capacity of 30 people
673 YONGE ST · Nov 5, 2026 · 175 m away - Building permit
2 Wall Sign****AXIA STATION****
608 YONGE ST · Nov 5, 2026 · 248 m away - Building permit
Proposal for interior alterations to accommodate new office
22 ST JOSEPH ST · Nov 4, 2026 · 153 m away - Building permit
REV: Proposed revision for ventilation adjustments based on as-built conditionProposal to replace heating plant, domestic hot water heating, potable water distribution, ventilation and air conditioning systems.
2 GLOUCESTER ST · Nov 3, 2026 · 195 m away
Neighbourhood: Bay-Cloverhill
About the area around the lot, not the lot itself.
- Nearest station
- Wellesley Station6 min walk
- Nearest TTC stop
- Bay St at Charles St West2 min walk
- Nearest cycling route
- Bay StSharrows - Arterial - Connector, 2 min walk
- Nearest traffic count
- 1,550 vehicles in 8 hSt Nicholas St / St Mary St, 60 m away, Oct 11, 2000
- Serious collisions within 500 m
- 112021–2026, killed or seriously injured: 0 fatal, 5 with pedestrians, 3 with cyclists
- Parks
- St. Mary Street Parkette1 min walk
- Clover Hill Park2 min walk
- Norman Jewison Park3 min walk
Schools within 1 km
- ST JOSEPH'S COLLEGE SCHOOL English Separate 6 min walk
- HUMBER COLLEGE - INTERNATIONAL GRADUATE SCHOOL College 6 min walk
- TORONTO SCHOOL OF THEOLOGY - U OF T, BLDG 434 University 7 min walk
- ROSEDALE DAY SCHOOL Private 7 min walk
- THE YMCA ACADEMY SECONDARY SCHOOL Private 7 min walk
- THE ABELARD CENTRE FOR EDUCATION Private 8 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Bay-Cloverhill | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $58,400 | $84,500 |
| Households that own their home | 30% | 54% |
| Population (2021) | 16,670 | 16,813 |
| Homes built in 1960 or before | 4% | 29% |
| Homes needing major repairs | 3% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Bay-Cloverhill | City median |
|---|---|---|
| Assault | 601.9 | 636.3 |
| Robbery | 74.7 | 69.5 |
| Auto theft | 16.6 | 192.6 |
| Theft over $5,000 | 87.2 | 46.1 |
| Break and enter | 286.4 | 172.8 |
| Theft from vehicles | 145.3 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.