Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
Heritage property: designated (Part IV)
Needs a closer lookOn the City's Heritage Register. Demolition and exterior changes need heritage review.
What it means. Renovations, additions and demolition can take longer, cost more or be refused.
How to confirm. Heritage Planning at the City confirms the status and what it covers. Details
City of Toronto Heritage Register2 building permits open, the oldest since 2018
Needs a closer lookStill open in the City's records: 24 102850 (ELECTROMAGNETIC LOCK INSTALLATION, 2024, status Permit Issued); 18 212196 (Proposal to install two maglocks in parking level of existing mixed-use building, Goode..., 2018, status Permit Issued).
What it means. An open permit can mean work that was never finished or never passed final inspection. After closing, finishing it or closing the file can fall to you.
How to confirm. Ask the seller for the final inspection records. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016)7 by-law investigations closed in the last two years
Good to knowClosed files (Order Issued Property Standards, Property Standards, Zoning): 26 239874 PRS 00 IV (Order Issued Property Standards: The plumbing system is not kept in good working order...., 2026); 26 229145 PRS 00 IR (Property Standards, 2026); 26 213465 PRS 00 IR (Property Standards, 2026); and 4 more.
What it means. Someone raised an issue here and the City closed the file. Ask the seller what it was about.
City of Toronto, Toronto Building orders and Municipal Licensing and Standards investigationsWork or applications in progress
Good to knowRecent records on this lot: 16 209440 (Proposal to use stainless steel for domestic water system in the proposed new multiple..., 2016).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications1 Committee of Adjustment file on this lot
Good to know1 approved. A0098/18TEY (To alter the redevelopment plan approved under Site-specific By-law 276-2015 for a 50-s..., 2018).
What it means. Approved variances and consents stay with the property, including any conditions in the decision. They allow what was approved, not more.
How to confirm. Decisions are in the Application Information Centre; older files are available from the Committee of Adjustment office. Details
City of Toronto, Committee of Adjustment applications (2001 onwards)13 development applications open within 300 m
Good to know13 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 69 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications1 short-term rental registrations here
Good to know1 active short-term rental registration at this address (Condominium).
What it means. Short-term rentals are allowed only in the operator's own principal residence, so a buyer cannot count on the same rental income. In a condo, check the building's rules too.
How to confirm. The City's short-term rental page explains registration and the principal residence rule. Details
City of Toronto, Short-term Rental RegistrationsRental building evaluation: 100 out of 100
Good to knowThe City's RentSafeTO program evaluated this rental building in 2025 (51 storeys, 503 units, built 2018).
What it means. The score covers common areas, building systems and records. Read the evaluation details for the items that scored low.
How to confirm. The City's RentSafeTO page has the evaluation results and any open orders for the building. Details
City of Toronto, RentSafeTO Apartment Building Evaluations
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
40 records on file: more than at 100% of Toronto houses (median 0).
- By-law investigation26 239874 PRS 00 IVClosed
Order Issued Property Standards: The plumbing system is not kept in good working order.Namely, the pipe under the kitchen sink is leaking and taped.; The supplied facility in or on the property is not kept in a satisfactory working condition.Namely, the dishwaher has an error code and is not functioning prope
Aug 31, 2026 · 592 SHERBOURNE ST - By-law investigation26 229145 PRS 00 IRClosed
Property Standards
Aug 31, 2026 · 592 SHERBOURNE ST - By-law investigation26 213465 PRS 00 IRClosed
Property Standards
Aug 4, 2026 · 25 SELBY ST - By-law investigation26 134502 PRS 00 IRClosed
Property Standards
Mar 25, 2026 · 25 SELBY ST - By-law investigation25 248458 ZON 00 IRClosed
Zoning
Nov 3, 2025 · 25 SELBY ST - By-law investigation25 238669 LGW 00 IRClosed
Long Grass and Weeds
Oct 11, 2025 · 592 SHERBOURNE ST - By-law investigation25 224372 PRS 00 IRClosed
Property Standards
Sep 11, 2025 · 25 SELBY ST - By-law investigation25 181842 PRS 00 IRClosed
Property Standards
Jun 23, 2025 · 25 SELBY ST
Show 32 older records
- Building permit24 102850Permit Issued
ELECTROMAGNETIC LOCK INSTALLATION
Feb 1, 2024 · 25 SELBY ST - Zoning review22 151993 LPRClosedMay 26, 2022 · 592 SHERBOURNE ST
- Zoning review19 220620 ZMPClosedSep 13, 2019 · 592 SHERBOURNE ST
- Building permit18 269188Cancelled
To erect and display one non-illuminated wall sign.****THE SELBY****
Dec 18, 2018 · 592 SHERBOURNE ST - Building permit18 249117Approved
Alterative Solution: where gas lines serving the emergency power supply for the building rise vertically through floors, or transfer horizontally from one location to another, it is proposed that protection using Morgan advanced materials duct wrap be permitted to maintain the construction assembly rating. As such, it is proposed to protect selected vertical and horizontal portions of gas lines with two layers of a fire rated wrap assembly having a 2H fire - resistance rating (tested and rated in accordance with ULC requirements for fire resistant ducts) to provide the required 2H fire separation, where they are not located in a construction assembly that has a fire-resistance rating of not less than 2H
Oct 29, 2018 · 592 SHERBOURNE ST - Zoning review18 225697 LPRClosedSep 14, 2018 · 592 SHERBOURNE ST
- Building permit18 222863Approved
Alternative Solution: Where standpipe risers rise vertically through floors, or transfer horizontally from one location to another, its is proposed that protection using morgan advanced materials duct wrap be permitted to maintain the service shaft rating. As such it is proposed to protect selected horizontal portions of standpipe risers with a fire-rated wrap assembly having a 2 H fire-resistance rating (tested and rated in accordance with ULC requirements for fire resistant ducts) to Provide the required 1 H fire separation, where they are not located within a stair shaft or fire rated service space.
Sep 10, 2018 · 592 SHERBOURNE ST - Building permit18 195278Closed
Interior alterations to basement and ground floor of Gooderham Mansion to convert from retail area to restaurant. New occupant load = 140 patrons + 5 staff.
Aug 30, 2018 · 592 SHERBOURNE ST - Building permit15 151323Closed
Revision to construct 2 additional exterior stairs at south side of Gooderham Mansion, interior alterations to ground & basement at Gooderham Mansion to revise exit stairs, relocation of fire house connections at exit stair, and alterations to level P1.
Aug 30, 2018 · 592 SHERBOURNE ST - Building permit18 212196Permit Issued
Proposal to install two maglocks in parking level of existing mixed-use building, Gooderham Mansion.
Aug 22, 2018 · 592 SHERBOURNE ST - Minor varianceA0098/18TEYApproved
To alter the redevelopment plan approved under Site-specific By-law 276-2015 for a 50-storey mixed-use building by increasing the maximum permitted non-residential gross floor area.
Apr 11, 2018 · 592 SHERBOURNE ST - Zoning review17 200128 ZSVClosedJul 17, 2017 · 592 SHERBOURNE ST
- Building permit16 209440Application Received
Proposal to use stainless steel for domestic water system in the proposed new multiple use building.
Aug 18, 2016 · 592 SHERBOURNE ST - Zoning review16 178106 PSPClosedJun 24, 2016 · 592 SHERBOURNE ST
- Development application16 178106 STE 27 SAClosed
Application to amend existing Site Plan Approval (14 190053 STE 27 SA) for a 50-storey residential tower with a 3-storey base and grade-related townhouse units. The existing Gooderham Mansion heritage building has been relocated east to Sherbourne Street and will connect to the proposed residential tower. 502 residential rental units and 225 m2 of retail space are proposed.
Jun 21, 2016 · 592 SHERBOURNE ST - Building permit15 144554Closed
Proposal to demolish a 3 storey motel.
Jun 30, 2015 · 592 SHERBOURNE ST - Building permit15 151343Approved
Proposal for alternative solution related to the 65 mm hose connections in lieu of fire hose stations for standpipe system that will be installed in proposed residential building
May 4, 2015 · 592 SHERBOURNE ST - Zoning review15 146268 ZZCClosedApr 24, 2015 · 592 SHERBOURNE ST
- Zoning review15 133066 LPRClosedMar 27, 2015 · 592 SHERBOURNE ST
- Zoning review14 215844 PSPClosedSep 3, 2014 · 592 SHERBOURNE ST
- Development application14 190053 STE 27 SAClosed
Site Plan approval application for a 50-storey residential tower including a 3-storey base building with grade-related townhhouse units. The existing Gooderham Mansion heritage building is to be located closer to Sherbourne Street and connect with the proposed residential tower.
Jul 14, 2014 · 592 SHERBOURNE ST - Development application13 264878 STE 27 OZClosed
Official Plan Amendment in connection with rezoning application 12-193918 STE 27 OZ to seek and permit the adaptive reuse of the 15 Selby Street site for both small scale office use and multiple residential dwelling units as well as potential servicing, mechanical and access in conjunction with the proposed redevelopment of 592 Sherbourne Street. REFER TO FILE 12-193918 STE 27 OZ.
Nov 13, 2013 · 592 SHERBOURNE ST - Zoning review12 204832 PRZClosedAug 21, 2012 · 592 SHERBOURNE ST
- Development application12 193918 STE 27 OZClosed
Rezoning application to permit a 50-storey tall residential tower including a 3-storey podium with grade related units for a total of 557 dwelling units. The Gooderham mansion heritage building on the site would be relocated closer to Sherbourne Street with the residential tower to be located behind the building. The application now inlcudes the property at 15 Selby Street with the existing building on the site being conserved,
Jun 15, 2012 · 17 SELBY ST - Building permit00 140585Closed
Revision: Proposal to remove existing exterior heating and cooling unit and replace with interior electric heater. h.v.a.c. alter ductwork on ground floor for existing hotel purposes. cost included in 00 140583 edc
Jun 10, 2011 · 592 SHERBOURNE ST - Building permit00 175272Closed
Install fixtures on first floor: 16 w.b., 16 w.c., 16 b.t. cost incl. 00 - 140583
Jul 26, 2000 · 592 SHERBOURNE ST - Building permit00 140583Closed
make interior alterations to ground floor for existing hotel purposes. edc HOLD FOR HISTORICAL BOARD APPROVAL, CURB CUT APPROVAL
Jul 5, 2000 · 592 SHERBOURNE ST - Zoning review99 118034 000ClosedDec 23, 1999 · 592 SHERBOURNE ST
- Zoning review99 109696 000ClosedNov 15, 1999 · 592 SHERBOURNE ST
- Building permit99 018014Closed
ERECT CANOPY AT FRONT JNB
Jun 22, 1999 · 592 SHERBOURNE ST - Zoning review84 026377 LTOClosedApr 26, 1984 · 592 SHERBOURNE ST
- Zoning review82 025768 LTOClosedFeb 24, 1982 · 592 SHERBOURNE ST
Check before you build
Zoning not in By-law 569-2013
Needs a closer lookThis lot is not covered by the citywide zoning by-law's map. It is probably still governed by a former municipal by-law, which this tool does not read yet.
Zoning By-law 569-2013
Lot facts
- Area
- 2,235 m²
- Frontage
- 33.1 m
- Depth
- 78.5 m
- Street
- Sherbourne St
- Corner lot
- Yes, also on Selby St78.5 m along it
- Public lane
- None
- House footprint
- 942 m²
- Back yard
- 11.1 mhouse to rear lot line
- Side yards
- 0 m and 14.1 mhouse to side lot lines; 0 is a shared wall
- Buildings on the lot
- 4house, garage, sheds
- Max height
- —
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
Around this lot
- Minor variances approved
- 100%14 of 14 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 5
- Development applications
- 25
Within 300 m, last 10 years. 5 suite and multiplex permits: more than at 59% of Toronto houses (median 3). 14 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceRefused
To alter the development standards, as approved under Site Specific Zoning By-laws 22769 and 325-82, for the existing 27-storey mixed-use building by reducing the building setbacks, increasing the residential dwelling units from 479 to 495 units, increasing the total gross floor area, and reducing the total amenity space. This application is subject to a Site Plan Control application, which has not yet been submitted by the applicant.
235 BLOOR ST E · Nov 4, 2026 · 302 m away - Minor varianceApproved
To alter the existing rear one-storey detached ancillary building (containing a three-car garage) by constructing a new roof (to increase the roof height).
20 ELM AVE · Sep 23, 2026 · 483 m away - Minor varianceApproved
To permit 30 undersized/partially obstructed vehicular parking spaces within the existing underground parking garage (Parking Levels 1 to 5) of the 53-storey mixed-use building, which is currently under construction.
603 SHERBOURNE ST · Nov 26, 2025 · 90 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 1529-2019), for a new 56-storey mixed-use building (which is currently under construction), by increasing the gross floor area, the total number of dwelling units, and the building height(s) for Building E (145.5 m to 159 m). There will be a total of 600 residential dwelling units on this lot.
591 SHERBOURNE ST · Sep 3, 2025 · 94 m away - Minor varianceApproved
To facilitate the redevelopment of this site for a 51-storey mixed-use building, including the Parkland dedication requirement. This application is necessitated to modify Sections 4, 7, 16, and 24 under Appendix 1, Site Specific Zoning By-law 1528-2019, and Sections 4, 7, 15, and 23 under Schedule A, Site Specific Zoning By-law 1529-2019, which relates to the timing of conveyance and lease of the parklands and the construction for park improvements.
601 SHERBOURNE ST · Jun 11, 2025 · 87 m away
Latest activity nearby
- Zoning review
Not Started
421 BLOOR ST E · Nov 23, 2026 · 123 m away - Building permit
Proposal for interior alterations to replace existing indoor diesel life-safety generator with new rooftop natural gas life safety generator.
77 HUNTLEY ST · Nov 18, 2026 · 143 m away - Building permit
Revision 01 - fire alarm upgrade to P1, P2, P3, P4, P5 and first and second floorFire Alarm Upgrade: to add strobes in the required area to address accessibility requirement, the rest existing fire alarm to remain.
1 MOUNT PLEASANT RD · Nov 18, 2026 · 197 m away - Building permit
Three wall sign.***NO FRILLS***
345 BLOOR ST E · Nov 10, 2026 · 88 m away - Building permit
Proposal for interior alteration to fit the nails salon
4 HOWARD ST · Oct 30, 2026 · 123 m away - Building permit
Replacement of existing fire damaged balcony railings and repair of existing balconies for unit 2307 & 2407.
375 BLEECKER ST · Oct 30, 2026 · 195 m away - Building permit
Interior alterations for a new nail salon in unit 4
6 HOWARD ST · Oct 27, 2026 · 135 m away - Building permit
REV 01: Revision to permit to include two risers Proposal to replace heating riser.
110 CHARLES ST E · Oct 20, 2026 · 291 m away - Building permit
Scope: to alter Designated Heritage houses in accordance with building design and Heritage Conservation Plan for integration with main tower.Construct a 61 storey market rental tower, with 4 levels of below grade parking. Proposed rental unit count is 716 units.
37 LINDEN ST · Oct 9, 2026 · 79 m away - Building permit
Scope: to alter Designated Heritage houses in accordance with building design and Heritage Conservation Plan for integration with main tower.Construct a 61 storey market rental tower, with 4 levels of below grade parking. Proposed rental unit count is 716 units
29 LINDEN ST · Oct 9, 2026 · 69 m away
Neighbourhood: North St.James Town
About the area around the lot, not the lot itself.
- Nearest station
- Sherbourne Station2 min walk
- Nearest TTC stop
- Sherbourne St at Bloor St East South Side - Sherbourne Station2 min walk
- Nearest cycling route
- Sherbourne StCycle Track, 1 min walk
- Nearest traffic count
- 9,684 vehicles in 14 hHoward St / Sherbourne St, 70 m away, Sep 11, 2025
- Serious collisions within 500 m
- 62021–2026, killed or seriously injured: 1 fatal, 3 with pedestrians, 2 with cyclists
- Parks
- St. James Town West Park1 min walk
- Rosedale Ravine Lands3 min walk
- Dr. Gordon Chong Park5 min walk
Schools within 1 km
- MONSIGNOR FRASER COLLEGE - ISABELLA NORTH English Separate 1 min walk
- MONSIGNOR FRASER COLLEGE - ISABELLA CAMPUS English Separate 2 min walk
- ROSE AVENUE JR PUBLIC SCHOOL English Public 6 min walk
- BRANKSOME HALL GIRLS SCHOOL Private 8 min walk
- THE ABELARD CENTRE FOR EDUCATION Private 9 min walk
- JARVIS COLLEGIATE INSTITUTE English Public 9 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | North St.James Town | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $59,200 | $84,500 |
| Households that own their home | 11% | 54% |
| Population (2021) | 18,535 | 16,813 |
| Homes built in 1960 or before | 19% | 29% |
| Homes needing major repairs | 10% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | North St.James Town | City median |
|---|---|---|
| Assault | 1281.6 | 636.3 |
| Robbery | 76.9 | 69.5 |
| Shootings | 4.3 | 10.5 |
| Auto theft | 85.4 | 192.6 |
| Theft over $5,000 | 38.4 | 46.1 |
| Break and enter | 153.8 | 172.8 |
| Theft from vehicles | 136.7 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.