Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
Cultural Heritage Evaluation Report required
Needs a closer lookThis property is listed under Official Plan Amendment 720: a heritage evaluation is needed before redevelopment.
What it means. Plans to tear down or rebuild will need a heritage evaluation first.
How to confirm. Heritage Planning at the City confirms the status. Details
Official Plan Amendment 7206 by-law investigations closed in the last two years
Good to knowClosed files (Order Issued Property Standards, Property Standards): 26 268364 PRS 00 IR (Property Standards, 2026); 26 241985 PRS 00 IR (Property Standards, 2026); 26 223478 PRS 00 IR (Property Standards, 2026); and 3 more.
What it means. Someone raised an issue here and the City closed the file. Ask the seller what it was about.
City of Toronto, Toronto Building orders and Municipal Licensing and Standards investigationsWork or applications in progress
Good to knowRecent records on this lot: 25 250769 (Proposed new handrails and guard for the existing stairs inside the front and rear of t..., 2025).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications1 Committee of Adjustment file on this lot
Good to know1 approved. A058/02M (This is an application under Section 45 of the Planning Act, for variance from the prov..., 2002).
What it means. Approved variances and consents stay with the property, including any conditions in the decision. They allow what was approved, not more.
How to confirm. Decisions are in the Application Information Centre; older files are available from the Committee of Adjustment office. Details
City of Toronto, Committee of Adjustment applications (2001 onwards)Rental building evaluation: 81 out of 100
Good to knowThe City's RentSafeTO program evaluated this rental building in 2025 (3 storeys, 31 units, built 1955).
What it means. The score covers common areas, building systems and records. Read the evaluation details for the items that scored low.
How to confirm. The City's RentSafeTO page has the evaluation results and any open orders for the building. Details
City of Toronto, RentSafeTO Apartment Building Evaluations
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
12 records on file: more than at 100% of Toronto houses (median 0).
- By-law investigation26 268364 PRS 00 IRClosed
Property Standards
Nov 10, 2026 · 211 EGLINTON AVE W - By-law investigation26 241985 PRS 00 IRClosed
Property Standards
Sep 22, 2026 · 211 EGLINTON AVE W - By-law investigation26 223478 PRS 00 IRClosed
Property Standards
Aug 20, 2026 · 211 EGLINTON AVE W - Building permit25 250769Permit Issued
Proposed new handrails and guard for the existing stairs inside the front and rear of the building
Dec 12, 2025 · 211 EGLINTON AVE W - By-law investigation25 217263 PRS 00 IVClosed
Order Issued Property Standards: Height of the guard for the exit stairs are less than 1,070 millimetres around landings.; Height of the guard for the exit stairs are less than 920 millimetres measured vertically to the top of the guard from a line drawn through the outside edges of; Required guard does not prevent the passage of a sphere having a diameter more than 100 millimetres.; The guard is designed that a member, attachment or opening located between 140 millimetres and 900 millimetres above the level being protected facilitates climb
Aug 27, 2025 · 211 EGLINTON AVE W - By-law investigation25 216844 PRS 00 IRClosed
Property Standards
Aug 27, 2025 · 211 EGLINTON AVE W - By-law investigation25 214273 PRS 00 IRClosed
Property Standards
Aug 21, 2025 · 211 EGLINTON AVE W - Building permit03 104049Closed
Plumbing- Install New Sanitary connection to the Existing Main drain to Hook up New plumbing Fixtures for the additional 2 Appt, units)
Jan 27, 2003 · 211 EGLINTON AVE W
Show 4 older records
- Building permit03 104027Closed
Plumbing- Install Fixtures-No Plans
Jan 23, 2003 · 211 EGLINTON AVE W - Building permit02 130365Closed
Make interior alterations to existing storage areas in basement for 2 additional dwelling units. Also install window openings in South elevation.
Nov 26, 2002 · 211 EGLINTON AVE W - Minor varianceA058/02MApproved
This is an application under Section 45 of the Planning Act, for variance from the provisions of the Toronto Zoning By-law 438-86, as amended, to permit interior alterations for the creation of two new residential units.
Feb 21, 2002 · 211 EGLINTON AVE W - Zoning review01 204207 ZPRClosedDec 19, 2001 · 211 EGLINTON AVE W
Check before you build
Site-specific exception 900.2.10(158)
Needs a closer look24 site-specific rules and 24 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
The lands must comply with exception 900.2.10(7)
- Rule B
Regulation 10.10.40.40(1) regarding the permitted maximum floor space index does not apply
- Rule C
The required minimum number of storeys for a building is 3 storeys
- Rule D
Despite regulation 10.10.20.40(1), only an apartment building or an apartment building containing ancillary non-residential uses, is permitted
- Rule E
Despite regulations 10.10.20.100(12), a retail store is permitted in an apartment building subject to the following: (i) it may not be above the first storey of the apartment building ; and (ii) the interior floor area of a retail store may not exceed 150 square metres
- Rule F
The required minimum height of the first storey , measured between the floor of the first storey and the ceiling of the first storey , is 4.0 metres
- Rule G
A floor level of the first storey in a building must: (i) be within 0.2 metres of the ground measured at the lot line abutting the street directly opposite each pedestrian entrance; and (ii) have a pedestrian access, other than service entrances, which, if not level with the public sidewalk closest to the entrance, is accessed by a ramp which rises no more than 0.04 metres vertically for every 1.0 metre horizontally
- Rule H
Despite regulation 10.10.40.30(1)(B), the maximum permitted building depth is 17.0 metres for an apartment building
- Rule I
Despite regulations 10.5.40.70(1) and 10.10.40.70(3), the minimum street yard setback for the portion of a lot abutting Eglinton Avenue West is the greater of: (i) the requirements in Regulation 10.5.40.70(1); or (ii) 4.5 metres for any portion of a building that contains ground floor dwelling units ; and (iii) 3.0 metres for any portion of a building that does not contain ground floor dwelling units
- Rule J
Despite regulation 10.10.40.70(2), a building or structure must be set back: (i) at least 7.5 metres from the rear lot line ; or (ii) where the rear lot line abuts a lane , at least 7.5 metres from the lot line of the lot abutting the lane on the opposite side of the lane
- Rule K
Despite regulation 5.10.40.70(2), building setback requirements in By-law 552-2023 apply to all portions of a building or structure above ground and below ground; except, (i) a below-ground parking garage may encroach within a required building setback , provided it is located a minimum depth of 1.5 metres
- Rule L
A minimum of 25 percent of the total number of dwelling units in a building containing between 5 and 79 dwelling units must contain a minimum of two or more bedrooms with a minimum interior floor area of 90 square metres for each dwelling unit ; and (i) where the calculation above results in a fraction, the number of required dwelling units may be rounded down to the next whole number
- Rule M
A building containing 80 dwelling units or greater must comply with the following: (i) a minimum of 15 percent of the total number of dwelling units on the lot must contain 2 bedrooms (ii) a minimum of 10 percent of the total number of dwelling units on the lot must contain 3 bedrooms; and (iii) in addition to the requirements of (i) and (ii) above, an additional 15 percent of the total number of dwelling units must include a minimum interior floor area of 90 square metres
- Rule N
Despite regulation 10.5.100.1(6), a lot in the Residential Zone category may have a driveway with a maximum of one vehicle access to a street
- Rule O
Despite regulations 10.5.80.40(1) and 10.10.80.40(1), a vehicle entrance through the front main wall of a residential building is not permitted
- Rule P
Despite regulation 10.5.80.40(3), vehicle access to a parking space on a lot must: (i) be from the lane, if the lot abuts a lane; and (ii) in all other cases, may only be from a driveway that provides access to a building containing two or more dwelling units
- Rule Q
Regulation 10.5.100.1(5) regarding driveway access to apartment buildings does not apply
- Rule R
If two or more residential buildings are located on the same lot , the required minimum above-ground separation distance between the main walls of the respective buildings is: (i) 5.5 metres if there are no openings to dwelling units in the main wall of one or more of the buildings ; and (ii) 11.0 metres if each main wall has an opening to a dwelling unit
- Rule S
The minimum required floor space index of all uses permitted in regulations 10.10.20.10(1) and 10.10.20.20(1) on a lot is 2.0
- Rule T
If the lawful gross floor area of lawfully existing buildings on a lot results in a floor space index less than the minimum floor space index required in Regulation 900.2.10(158)(S), the lawful floor space index resulting from those lawfully existing buildings on that lot is the minimum floor space index for those lawfully existing buildings on that lot
- Rule U
A lawfully existing office is permitted at 151 Eglinton Avenue West
- Rule V
A lawfully existing funeral home is permitted at 159, 170 Eglinton Avenue West
- Rule W
If the lawful number of storeys and building height of a lawfully existing building does not satisfy the requirements of Regulations 900.2.10(158)(C), that lawful number of storeys and lawful building height are the required minimum number of storeys and building height for that lawfully existing building or structure
- Rule X
Regulations 900.2.10(158)(N), (O), (P) and (Q) above do not apply to a lawfully existing residential building containing a lawfully existing vehicle entrance or vehicle access. Prevailing By-laws and Prevailing Sections: (None Apply)
- Older by-law A
The lands must comply with exception 900.2.10(7)
- Older by-law B
Regulation 10.10.40.40(1) regarding the permitted maximum floor space index does not apply
- Older by-law C
The required minimum number of storeys for a building is 3 storeys
- Older by-law D
Despite regulation 10.10.20.40(1), only an apartment building or an apartment building containing ancillary non-residential uses, is permitted
- Older by-law E
Despite regulations 10.10.20.100(12), a retail store is permitted in an apartment building subject to the following: (i) it may not be above the first storey of the apartment building ; and (ii) the interior floor area of a retail store may not exceed 150 square metres
- Older by-law F
The required minimum height of the first storey , measured between the floor of the first storey and the ceiling of the first storey , is 4.0 metres
- Older by-law G
A floor level of the first storey in a building must: (i) be within 0.2 metres of the ground measured at the lot line abutting the street directly opposite each pedestrian entrance; and (ii) have a pedestrian access, other than service entrances, which, if not level with the public sidewalk closest to the entrance, is accessed by a ramp which rises no more than 0.04 metres vertically for every 1.0 metre horizontally
- Older by-law H
Despite regulation 10.10.40.30(1)(B), the maximum permitted building depth is 17.0 metres for an apartment building
- Older by-law I
Despite regulations 10.5.40.70(1) and 10.10.40.70(3), the minimum street yard setback for the portion of a lot abutting Eglinton Avenue West is the greater of: (i) the requirements in Regulation 10.5.40.70(1); or (ii) 4.5 metres for any portion of a building that contains ground floor dwelling units ; and (iii) 3.0 metres for any portion of a building that does not contain ground floor dwelling units
- Older by-law J
Despite regulation 10.10.40.70(2), a building or structure must be set back: (i) at least 7.5 metres from the rear lot line ; or (ii) where the rear lot line abuts a lane , at least 7.5 metres from the lot line of the lot abutting the lane on the opposite side of the lane
- Older by-law K
Despite regulation 5.10.40.70(2), building setback requirements in By-law 552-2023 apply to all portions of a building or structure above ground and below ground; except, (i) a below-ground parking garage may encroach within a required building setback , provided it is located a minimum depth of 1.5 metres
- Older by-law L
A minimum of 25 percent of the total number of dwelling units in a building containing between 5 and 79 dwelling units must contain a minimum of two or more bedrooms with a minimum interior floor area of 90 square metres for each dwelling unit ; and (i) where the calculation above results in a fraction, the number of required dwelling units may be rounded down to the next whole number
- Older by-law M
A building containing 80 dwelling units or greater must comply with the following: (i) a minimum of 15 percent of the total number of dwelling units on the lot must contain 2 bedrooms (ii) a minimum of 10 percent of the total number of dwelling units on the lot must contain 3 bedrooms; and (iii) in addition to the requirements of (i) and (ii) above, an additional 15 percent of the total number of dwelling units must include a minimum interior floor area of 90 square metres
- Older by-law N
Despite regulation 10.5.100.1(6), a lot in the Residential Zone category may have a driveway with a maximum of one vehicle access to a street
- Older by-law O
Despite regulations 10.5.80.40(1) and 10.10.80.40(1), a vehicle entrance through the front main wall of a residential building is not permitted
- Older by-law P
Despite regulation 10.5.80.40(3), vehicle access to a parking space on a lot must: (i) be from the lane, if the lot abuts a lane; and (ii) in all other cases, may only be from a driveway that provides access to a building containing two or more dwelling units
- Older by-law Q
Regulation 10.5.100.1(5) regarding driveway access to apartment buildings does not apply
- Older by-law R
If two or more residential buildings are located on the same lot , the required minimum above-ground separation distance between the main walls of the respective buildings is: (i) 5.5 metres if there are no openings to dwelling units in the main wall of one or more of the buildings ; and (ii) 11.0 metres if each main wall has an opening to a dwelling unit
- Older by-law S
The minimum required floor space index of all uses permitted in regulations 10.10.20.10(1) and 10.10.20.20(1) on a lot is 2.0
- Older by-law T
If the lawful gross floor area of lawfully existing buildings on a lot results in a floor space index less than the minimum floor space index required in Regulation 900.2.10(158)(S), the lawful floor space index resulting from those lawfully existing buildings on that lot is the minimum floor space index for those lawfully existing buildings on that lot
- Older by-law U
A lawfully existing office is permitted at 151 Eglinton Avenue West
- Older by-law V
A lawfully existing funeral home is permitted at 159, 170 Eglinton Avenue West
- Older by-law W
If the lawful number of storeys and building height of a lawfully existing building does not satisfy the requirements of Regulations 900.2.10(158)(C), that lawful number of storeys and lawful building height are the required minimum number of storeys and building height for that lawfully existing building or structure
- Older by-law X
Regulations 900.2.10(158)(N), (O), (P) and (Q) above do not apply to a lawfully existing residential building containing a lawfully existing vehicle entrance or vehicle access. Prevailing By-laws and Prevailing Sections: (None Apply)
Lot facts
- Area
- 853 m²
- Frontage
- 27.4 m
- Depth
- 31.6 m
- Street
- Eglinton Ave W
- Corner lot
- No
- Public lane
- None
- House footprint
- 543 m²roof up to 21.2 m
- Back yard
- 4.1 mhouse to rear lot line
- Side yards
- 0.2 m and 2.3 mhouse to side lot lines; 0 is a shared wall
- Buildings on the lot
- 1house, garage, sheds
- Max height
- 13 m
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
- Yonge-Eglinton Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Zone R (x158) (Residential). Chapter 10, section 10.10 of the by-law. Source
- 2 City trees in front of this lot. The City's street tree inventory lists 2 trees at this address: maple, norway crimson king (19 cm), maple, norway crimson king (19 cm). Diameter is the trunk at breast height. Source
Around this lot
- Minor variances approved
- 97%31 of 32 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 8
- Development applications
- 0
Within 300 m, last 10 years. 8 suite and multiplex permits: more than at 70% of Toronto houses (median 3). 32 variance decisions: more than at 65% of Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To alter the existing two-storey detached dwelling by constructing a front covered porch with stairs, a front ground floor bay window, a rear two-storey addition (including a basement addition), with two decks and stairs. Also, there will be one side (north) yard parking space. The existing rear one-storey addition, rear deck, and rear one-storey ancillary building (garage) will be demolished.
59 EASTBOURNE AVE · Jul 8, 2026 · 465 m away - Minor varianceApproved
To alter the existing detached dwelling by constructing a third storey addition and converting into an apartment building with 5 dwelling units.
66 BURNABY BLVD · Jun 4, 2026 · 405 m away - Minor varianceApproved
To construct a new seven-storey detached residential building (multiplex), with a ground floor front entrance canopy, a rear ground floor terrace, rear balconies on the second to sixth levels, front and rear rooftop terraces, and a rear outdoor amenity area on the seventh level. There will be a total of 6 residential dwelling units on this lot. Also, there will be 1 surface visitor parking space in the rear yard, and a total of 12 parking spaces (of which 2 are accessible parking spaces), and 6 long-term bicycle parking spaces (to be provided within a two-level underground parking garage (with elevator access)). This application is necessitated to reflect the variances required for a seven-storey residential building, as well as the variances that were previously approved under Minor Variance Decision A0683/25TEY, but still apply.
996 AVENUE RD · Apr 29, 2026 · 297 m away - Minor varianceApproved
To alter the existing two-storey detached dwelling by constructing a rear two-storey addition (including a basement extension) with a rear ground level deck with stairs.
52 ANDERSON AVE · Feb 18, 2026 · 197 m away - Minor varianceApproved
To construct a 2 storey rear addition with deck.
701 ORIOLE PKWY · Jan 8, 2026 · 452 m away
Latest activity nearby
- Zoning review
Closed
191 HIGHBOURNE RD · Nov 23, 2026 · 153 m away - Building permit
Construct a carport canopy
648 ORIOLE PKWY · Nov 17, 2026 · 266 m away - Building permit
Proposal to remove the existing second floor guardrail and replace it with a parapet wall, and to create two roof penetrations in preparation for future HVAC installation
174 EGLINTON AVE W · Nov 9, 2026 · 169 m away - Building permit
Proposed basement underpinning and interior alterations
159 COLIN AVE · Nov 9, 2026 · 278 m away - Building permit
REV 01: RELOCATION OF SPRINKLERS IN LOBBY AREAProposal to add sprinkler system to lobby.
30 EDITH DR · Nov 6, 2026 · 228 m away - Zoning review
Closed
272 EGLINTON AVE W · Nov 5, 2026 · 154 m away - Building permit
Proposal to Replace and Relocate the Base Building Fire Alarm Control Panel and Relocate Fire Department Connections for the Sprinkler and Standpipe Systems.
118 EGLINTON AVE W · Nov 4, 2026 · 297 m away - Building permit
Proposed new carport canopy
648 ORIOLE PKWY · Oct 16, 2026 · 266 m away - Building permit
Install backwater valve
657 ORIOLE PKWY · Sep 23, 2026 · 287 m away - Building permit
To erect and display one illuminated wall sign.***CROCK A DOODLE***
294 EGLINTON AVE W · Sep 15, 2026 · 216 m away
Neighbourhood: Yonge-Eglinton
About the area around the lot, not the lot itself.
- Nearest station
- Avenue Station5 min walk
- Nearest TTC stop
- Eglinton Ave West at Oriole Pkwy East Side1 min walk
- Nearest cycling route
- Eglinton Ave WCycle Track, 1 min walk
- Nearest traffic count
- 16,512 vehicles in 14 hEglinton Ave W / Oriole Pkwy (East), 70 m away, May 29, 2024
- Serious collisions within 500 m
- 12021–2026, killed or seriously injured: 0 fatal, 1 with pedestrians, 0 with cyclists
- Parks
- Eglinton Park1 min walk
- 233 Duplex Ave Park7 min walk
- Montgomery Square Park11 min walk
Schools within 1 km
- BIRMINGHAM INTERNATIONAL COLLEGIATE OF CANADA Private 6 min walk
- ORIOLE PARK JR PUBLIC SCHOOL English Public 7 min walk
- MARSHALL MCLUHAN CATHOLIC SECONDARY SCHOOL English Separate 7 min walk
- CAESAR INTERNATIONAL ACADEMY Private 11 min walk
- THE STUDY ACADEMY Private 12 min walk
- ALLENBY JR PUBLIC SCHOOL English Public 13 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Yonge-Eglinton | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $94,000 | $84,500 |
| Households that own their home | 37% | 54% |
| Population (2021) | 12,410 | 16,813 |
| Homes built in 1960 or before | 47% | 29% |
| Homes needing major repairs | 6% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Yonge-Eglinton | City median |
|---|---|---|
| Assault | 713.8 | 636.3 |
| Robbery | 95.2 | 69.5 |
| Auto theft | 115.6 | 192.6 |
| Theft over $5,000 | 102 | 46.1 |
| Break and enter | 136 | 172.8 |
| Theft from vehicles | 54.4 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.