Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
1 development application open within 300 m
Good to know1 rezoning, site plan, subdivision or condominium application within 300 m, submitted in the last 10 years, is not closed yet, including buildings of up to 4 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
1 records on file: more than at 53% of Toronto houses (median 0).
- Building permit14 174027Closed
Revision to alter layout and change door to a window.
Aug 25, 2014 · 2047 AVENUE RD
Check before you build
Site-specific exception 900.11.10(1543)
Needs a closer look16 site-specific rules and 16 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
If the maximum height permitted as per regulation 40.10.40.10(2) is 5 storeys or 16.5 metres, whichever is the lesser height applies: (i) a mechanical penthouse or other rooftop structures is not included in the permitted maximum height; and (ii) The mechanical penthouse or other rooftop structures must not exceed this height limit by more than 2 metres
- Rule B
If the maximum height permitted as per regulation 40.10.40.10(2) is 7 storeys or 22.5 metres, a mechanical penthouse or other rooftop structures are not included in the permitted maximum height
- Rule C
The height of any part of a building or structure , including the mechanical penthouse, must be contained within a 45 degree angular plane projected over the entire lot from grade level at a rear lot line that is also the boundary of an RD, RS, O, or OR zone
- Rule D
The height of any part of a building or structure , including the mechanical penthouse, must be contained within a 45 degree angular plane projected over the entire lot from the surface of the centre-point of the Avenue Rd. right-of-way
- Rule E
The minimum height of any part of a building or structure , exclusive of the mechanical penthouse or other rooftop structures , must not be less than 2 storeys or 7.5 metres, whichever is greater, for at least 50% of the total depth of the building or structure
- Rule F
The first storey of any building or structure will have a minimum floor to floor height of 4.5 metres. For the purposes of this provision, the first storey is deemed to be the storey with a floor level closest to the average elevation of the public sidewalk abutting Avenue Rd.
- Rule G
The maximum gross floor area must not exceed a maximum floor space index of 3.0, of which a maximum floor space index of 2.0 must be used for commercial purposes
- Rule H
If no laneway exists on the rear portion of the lot , no part of any building or structure may be located within a setback of 7.5 metres from the rear lot line
- Rule I
If a laneway exists on the rear portion of the lot , no part of any building or structure may be located within a setback of 9 metres from the rear lot line
- Rule J
The setback required by (I) above, must include a minimum 1.5 metre-wide landscaping strip along the rear lot line
- Rule K
If a lot fronts onto Avenue Rd. between the Melrose Avenue and Joicey Boulevard rights of way, no part of a building or structure is to be located within a setback from the front lot line that is the average of the shortest distance by which the front wall(s) of the adjacent building(s) or structure(s) are set back from their front lot line
- Rule L
A building or structure must be no less than 10.0 metres from the top of bank of a valley or ravine
- Rule M
Any building or structure 3 storeys or greater in height must have a minimum 2.0 metre step-back at the top of the second storey from all main walls facing a lot line which abuts a street , measured from the exterior of the main wall .
- Rule N
Any building or structure abutting Avenue Rd. must be built to a minimum height of two storeys at the lot line or the front yard setback provided for in paragraph (K) above and occupying at least 80% of the length of the portion of the lot abutting Avenue Rd.
- Rule O
The finished floor level of the first storey of any building or structure fronting on to Avenue Rd. must be within 0.2 metres of grade measured at the street line directly opposite each pedestrian opening
- Rule P
At least 60% of the floor area of the first storey of any building or structure fronting on to Avenue Rd. must be used for non-residential purposes. Prevailing By-laws and Prevailing Sections: (None Apply)
- Older by-law A
If the maximum height permitted as per regulation 40.10.40.10(2) is 5 storeys or 16.5 metres, whichever is the lesser height applies: (i) a mechanical penthouse or other rooftop structures is not included in the permitted maximum height; and (ii) The mechanical penthouse or other rooftop structures must not exceed this height limit by more than 2 metres
- Older by-law B
If the maximum height permitted as per regulation 40.10.40.10(2) is 7 storeys or 22.5 metres, a mechanical penthouse or other rooftop structures are not included in the permitted maximum height
- Older by-law C
The height of any part of a building or structure , including the mechanical penthouse, must be contained within a 45 degree angular plane projected over the entire lot from grade level at a rear lot line that is also the boundary of an RD, RS, O, or OR zone
- Older by-law D
The height of any part of a building or structure , including the mechanical penthouse, must be contained within a 45 degree angular plane projected over the entire lot from the surface of the centre-point of the Avenue Rd. right-of-way
- Older by-law E
The minimum height of any part of a building or structure , exclusive of the mechanical penthouse or other rooftop structures , must not be less than 2 storeys or 7.5 metres, whichever is greater, for at least 50% of the total depth of the building or structure
- Older by-law F
The first storey of any building or structure will have a minimum floor to floor height of 4.5 metres. For the purposes of this provision, the first storey is deemed to be the storey with a floor level closest to the average elevation of the public sidewalk abutting Avenue Rd.
- Older by-law G
The maximum gross floor area must not exceed a maximum floor space index of 3.0, of which a maximum floor space index of 2.0 must be used for commercial purposes
- Older by-law H
If no laneway exists on the rear portion of the lot , no part of any building or structure may be located within a setback of 7.5 metres from the rear lot line
- Older by-law I
If a laneway exists on the rear portion of the lot , no part of any building or structure may be located within a setback of 9 metres from the rear lot line
- Older by-law J
The setback required by (I) above, must include a minimum 1.5 metre-wide landscaping strip along the rear lot line
- Older by-law K
If a lot fronts onto Avenue Rd. between the Melrose Avenue and Joicey Boulevard rights of way, no part of a building or structure is to be located within a setback from the front lot line that is the average of the shortest distance by which the front wall(s) of the adjacent building(s) or structure(s) are set back from their front lot line
- Older by-law L
A building or structure must be no less than 10.0 metres from the top of bank of a valley or ravine
- Older by-law M
Any building or structure 3 storeys or greater in height must have a minimum 2.0 metre step-back at the top of the second storey from all main walls facing a lot line which abuts a street , measured from the exterior of the main wall .
- Older by-law N
Any building or structure abutting Avenue Rd. must be built to a minimum height of two storeys at the lot line or the front yard setback provided for in paragraph (K) above and occupying at least 80% of the length of the portion of the lot abutting Avenue Rd.
- Older by-law O
The finished floor level of the first storey of any building or structure fronting on to Avenue Rd. must be within 0.2 metres of grade measured at the street line directly opposite each pedestrian opening
- Older by-law P
At least 60% of the floor area of the first storey of any building or structure fronting on to Avenue Rd. must be used for non-residential purposes. Prevailing By-laws and Prevailing Sections: (None Apply)
Lot facts
- Area
- 1,373 m²
- Frontage
- 33 m
- Depth
- 44.8 m
- Street
- Avenue Rd
- Corner lot
- No
- Public lane
- None
- House footprint
- 683 m²roof up to 9.6 m
- Back yard
- 5.5 mhouse to rear lot line
- Side yards
- 0 m and 13.2 mhouse to side lot lines; 0 is a shared wall
- Buildings on the lot
- 1house, garage, sheds
- Max height
- 22.5 m
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
Around this lot
- Minor variances approved
- 91%29 of 32 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 0
- Development applications
- 1
Within 300 m, last 10 years. 0 suite and multiplex permits: no more than at most Toronto houses (median 3). 32 variance decisions: more than at 65% of Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To convert the existing one-storey detached dwelling into a restaurant (coffee shop) through interior alterations. The existing front yard is proposed to be altered by adding an outdoor seating area and removing the front parking pad.
194 ROE AVE · Oct 29, 2026 · 407 m away - Minor varianceApproved
The proposal is to obtain a variance for reduced parking. The application was previously deferred January 28, 2021, to allow the applicant to meet with Transportation Services.
1973 AVENUE RD · Oct 7, 2021 · 176 m away - Minor varianceApproved
To permit interior alterations to the existing building, which would facilitate in the conversion of the existing beauty salon, to a proposed medical clinic.
1896 AVENUE RD · Feb 20, 2020 · 398 m away - Minor varianceApproved
To construct a two-storey rear addition to the existing two-storey building (clinic/spa) to be used for a medical office.
1940 AVENUE RD · Jul 6, 2017 · 270 m away - Minor varianceApproved
To construct a one-storey rear addition to the existing one-storey building.
1952 AVENUE RD · Dec 10, 2015 · 248 m away
Latest activity nearby
- Building permit
Proposal to demolish existing building and construct a new 2 storey SFD with front porch and rear deck.
11 CARMICHAEL AVE · Nov 4, 2026 · 179 m away - Building permit
Proposal for a new 2 storey SFD with front porch and rear deck.
11 CARMICHAEL AVE · Nov 4, 2026 · 179 m away - Building permit
Proposal to replace rear deck with new deck. Same size and location.
125 FELBRIGG AVE · Oct 20, 2026 · 259 m away - Zoning review
Closed
1982 AVENUE RD · Oct 7, 2026 · 138 m away - Building permit
Proposal to demo existing building to construct a new 2 storey SFD.
177 JOICEY BLVD · Sep 25, 2026 · 73 m away - Building permit
Proposal to demo existing house to construct new 2 Storey detached SFD.
177 JOICEY BLVD · Sep 25, 2026 · 73 m away - Building permit
Install sanitary line backwater valve
38 HADDINGTON AVE · Sep 23, 2026 · 288 m away - Zoning review
Closed
2043 C AVENUE RD · Sep 9, 2026 · 25 m away - Building permit
Revision: Stucco cladding installed on the side exterior walls that encroaches into the appoved setbacks
178 JOICEY BLVD · Aug 26, 2026 · 109 m away - Minor varianceApproved
To construct a new detached dwelling with a rear deck.
11 CARMICHAEL AVE · Aug 20, 2026 · 179 m away
Neighbourhood: Bedford Park-Nortown
About the area around the lot, not the lot itself.
- Nearest station
- York Mills Station23 min walk
- Nearest TTC stop
- Avenue Rd at Dunblaine Ave1 min walk
- Nearest cycling route
- Ridley BlvdSigned Route (No Pavement Markings), 14 min walk
- Nearest traffic count
- 17,658 vehicles in 8 hAvenue Rd / Dunblaine Ave, 50 m away, Apr 7, 2022
- Serious collisions within 500 m
- 12021–2026, killed or seriously injured: 1 fatal, 1 with pedestrians, 0 with cyclists
- Parks
- Grey Parkette10 min walk
- Old Orchard Park10 min walk
- Stewart A. McGregor Parkette14 min walk
Schools within 1 km
- ARMOUR HEIGHTS PUBLIC SCHOOL English Public 8 min walk
- ST MARGARET CATHOLIC ELEMENTARY SCHOOL - CARMICHAEL SITE English Separate 9 min walk
- GLEN BRIAR ACADEMY ELEMENTARY SCHOOL Private 10 min walk
- LORETTO ABBEY CATHOLIC SECONDARY SCHOOL English Separate 14 min walk
- MAGNIFICENT MINDS SCHOOL Private 16 min walk
- SUMMIT HEIGHTS PUBLIC SCHOOL English Public 16 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Bedford Park-Nortown | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $135,000 | $84,500 |
| Households that own their home | 68% | 54% |
| Population (2021) | 22,145 | 16,813 |
| Homes built in 1960 or before | 33% | 29% |
| Homes needing major repairs | 5% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Bedford Park-Nortown | City median |
|---|---|---|
| Assault | 230.1 | 636.3 |
| Robbery | 59.5 | 69.5 |
| Auto theft | 150.8 | 192.6 |
| Theft over $5,000 | 67.4 | 46.1 |
| Break and enter | 250 | 172.8 |
| Theft from vehicles | 198.4 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.