Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
2 building permits open, the oldest since 2019
Needs a closer lookStill open in the City's records: 21 191607 (Proposal to construct an 8 storey, 25 unit, residential condo apartment building with t..., 2022, status Inspection); 19 178527 (Proposal to renovate existing suites for the purpose of creating a temporary sales offi..., 2019, status Inspection).
What it means. An open permit can mean work that was never finished or never passed final inspection. After closing, finishing it or closing the file can fall to you.
How to confirm. Ask the seller for the final inspection records. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016)Work or applications in progress
Good to knowRecent records on this lot: 26 125986 (Proposed interior alteration of vacant commercial to create dental clinic on ground flo..., 2026); 21 191566 (REV: 8 storey residential apartment building with 3 levels of U/G parking, this is an a..., 2025).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications2 Committee of Adjustment files on this lot
Good to know2 approved. A0602/25TEY (To alter the development standards for an 8-storey mixed-use building (approved under S..., 2025); A0069/08TEY (To legalize and to maintain the dental office use on the ground floor of the existing m..., 2008).
What it means. Approved variances and consents stay with the property, including any conditions in the decision. They allow what was approved, not more.
How to confirm. Decisions are in the Application Information Centre; older files are available from the Committee of Adjustment office. Details
City of Toronto, Committee of Adjustment applications (2001 onwards)
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
21 records on file: more than at 100% of Toronto houses (median 0).
- Building permit26 125986Inspection
Proposed interior alteration of vacant commercial to create dental clinic on ground floor unit
Jun 17, 2026 · 2010 BATHURST ST - Minor varianceA0602/25TEYApproved
To alter the development standards for an 8-storey mixed-use building (approved under Site Specific Zoning By-Law 1543-2019) by constructing a vestibule, for the elevator on the mechanical penthouse level, which will lead to the rooftop amenity space.
Oct 22, 2025 · 2010 BATHURST ST - Building permit21 191566Revision Issued
REV: 8 storey residential apartment building with 3 levels of U/G parking, this is an amendment to existing permit #21-191566 BLD 00 NB. interior alterations at 2 and 6. Proposed 9th storey vestibule addition no longer proposed through this revision. 06 revision expected following CoA approval. Proposal to construct a nine storey, 25 unit, residential condo apartment building with three levels of underground parking.
Oct 7, 2025 · 2010-2012 BATHURST ST - Building permit24 229258Closed
Installation of six (6) maglocks at P3, P2 & P1 levels
Oct 29, 2024 · 2010 BATHURST ST - Development application24 166605 STE 12 CDClosed
Draft Plan of Condominium for a nine storey residential building with 25 dwelling units.
Jun 18, 2024 · 2010-2012 BATHURST ST · City file - Building permit21 191607Inspection
Proposal to construct an 8 storey, 25 unit, residential condo apartment building with three levels of underground parking.
Nov 21, 2022 · 2010-2012 BATHURST ST - Building permit22 192320Closed
CONSTRUCTION OF 8 STOREY, 25 UNIT RESIDENTIAL CONDO APARTMENT BLDG. WITH THREE LEVELS U/G PARKING (Part of 21 191566 BLD 00 NB)
Sep 15, 2022 · 2014 BATHURST ST - Building permit21 191625Closed
Proposal to demolish existing two buildings ( located at 2010 -2012 Bathurst and 2014-2016 Bathurst) and construct an 8 storey, 25 unit, residential condo apartment building with three levels of underground parking.
Sep 15, 2022 · 2010-2012 BATHURST ST
Show 13 older records
- Building permit21 191648Approved
Proposed alternative solution for providing 65 mm diameter standpipe hose connections within the exit stairs (and as required on the floor areas for coverage purposes) in lieu of traditional fire hose cabinets (containing 38 mm and 30 m of fire hose) for the proposed residential building.
Jul 29, 2021 · 2010-2012 BATHURST ST - Building permit21 159056Cancelled
To erect and display three non-illuminated wall signs.*****THE RHODES*****
May 26, 2021 · 2014 BATHURST ST - Zoning review20 163848 ZZCClosedJul 6, 2020 · 2010-2012 BATHURST ST
- Zoning review19 194144 PSPClosedJun 24, 2020 · 2010-2012 BATHURST ST
- Building permit19 246254Closed
To erect and display one non-illuminated wall sign at the first storey of the east elevation of the building.****RHODES****
Dec 20, 2019 · 2014 BATHURST ST - Zoning review18 246984 PRZClosedSep 26, 2019 · 2010-2012 BATHURST ST
- Building permit19 178527Inspection
Proposal to renovate existing suites for the purpose of creating a temporary sales office for new condominium project to replace this building.
Sep 16, 2019 · 2014 BATHURST ST - Development application19 194144 STE 12 SAClosed
Site Plan Approval for proposed 8-storey building containing 4,630 square metres of residential gross floor area comprised of 26 residential units, 40 below grade parking spaces, and 26 bicycle parking spaces.
Jul 23, 2019 · 2014 BATHURST ST · City file - Development application18 246984 STE 21 OZClosed
Zoning By-law and Official Plan Amendment application to facilitate redevelopment of the site with an eight-storey mixed use development. 4.356 sq. m. residential gross floor area and 276 square metres of retail space on the ground floor.
Oct 23, 2018 · 2010-2012 BATHURST ST · City file - Minor varianceA0069/08TEYApproved
To legalize and to maintain the dental office use on the ground floor of the existing mixed-use building that was converted prior to the passing of the Zoning by-law. Further, to convert the existing ground floor residential unit into an additional office use. The two dwelling units in the basement and the dwelling unit on the second floor will be maintained. REQUESTED PERMISSION: The property has lawful-nonconforming status under the Planning Act, as the office/business use existed prior to the passing of the Zoning By-law, which does not permit the said use in an R3 zone. Any change of use, alterations or additions to the building requires the permission of the Committee of Adjustment.
Feb 6, 2008 · 2010 BATHURST ST - Zoning review07 251493 ZPRClosedAug 9, 2007 · 2010-2012 BATHURST ST
- Zoning review07 137294 LTOClosedApr 3, 2007 · 2014 BATHURST ST
- Building permit01 183236Closed
DEMISING WALL AND INTERIOR ALTERATIONS
Mar 14, 2002 · 2014 BATHURST ST
Check before you build
Site-specific exception 900.11.10(217)
Needs a closer look17 site-specific rules and 17 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
Despite regulation 40.10.40.10(2) the permitted maximum height of a building or structure , is specified by the numbers following the symbol HT, as shown on Diagram 4 attached to By-law 1543-2019
- Rule B
Despite regulation 40.10.40.40(1), the maximum permitted gross floor area of all buildings and structures on the lot must not exceed 4,800 square metres, of which: (i) Residential uses must not exceed 4,680 square metres; and (ii) Non-residential uses must not exceed 120 square metres
- Rule C
Despite regulation 40.5.40.10(1), the height of the building is the distance between Canadian Geodetic Datum elevation of 171.11 metres and the elevation of highest point of the building
- Rule D
Despite regulation 40.5.40.10(4) the following may project above the permitted maximum height: (i) elevator overruns, mechanical penthouses, mechanical equipment, and stair enclosures a maximum of 6.1 metres to top of parapet; (ii) terraces and balcony guards, elements of a green roof and insulation and roof surface materials, planters, railings, parapets, and ornamental architectural features, a maximum of 3.0 metres
- Rule E
Regulation 40.10.40.1(1) does not apply, except that non-residential uses must be located on the first storey of the mixed use building and must be fronting on Bathurst Street, and a maximum of two dwelling units are permitted to front onto Bathurst Street.
- Rule F
Despite regulations 40.10.40.70(2), the required minimum building setbacks are as shown on Diagram 5 of By-law 1543-2019
- Rule G
Despite regulations 40.10.40.70(2)(E) and 40.10.40.70(2)(G) a building or structure complying with the heights and setbacks as shown on Diagram 4 and Diagram 5 of By-law 1543-2019 is permitted to penetrate the required 45 degree angular plane.
- Rule H
Regulation 40.10.50.10(2) with respect to fencing along the lot line between the Residential Zone category and the subject lands, does not apply
- Rule I
Regulation 40.10.50.10(3) with respect to a minimum of 1.5 metres wide strip of soft landscaping along the lot line between the Residential Zone category and the subject lands, does not apply
- Rule J
Despite Clause 200.5.1.10(12)(A) the vehicle entrance and exit for a two-way driveway into and out of the building will have a minimum width of 4.5 metres at the garage door and 4.7 metres along the ramp
- Rule K
Despite Clause 200.15.1.5(1) accessible parking spaces must be provided below ground on the lot , and be located closest to an accessible elevator connected to the main pedestrian entrance to the building
- Rule L
Despite regulation 230.5.10.1(4) and (5) a minimum of 23 long-term bicycle parking spaces and zero short-term bicycle parking spaces must be provided and maintained within the building
- Rule M
The provision of dwelling units is subject to the following: (i) a minimum of 25 percent of all dwelling units on the lot must be 2- or more bedroom dwelling units; (ii) a minimum of 10 percent of all dwelling units on the lot must be 3- or more bedroom dwelling units; and (iii) if the calculation of the number of required dwelling units pursuant to (i) and (ii) above results in a number with a fraction, the number is rounded down to the nearest whole number
- Rule N
Regulation 40.10.40.50 (1)(B) with respect to a minimum of 40 square metres of outdoor amenity space required to be in a location adjoining or directly accessible to the indoor amenity space , does not apply.
- Rule O
Despite regulations 40.10.40.70(1)(A), 40.10.40.70(2)(A) and 40.10.40.70(4)(A) residential uses on the first storey shall be setback a minimum of 2.2 metres from the front lot line .
- Rule P
Despite regulations (F) above, 40.10.40.70(2), 40.10.40.60(1), and Diagram 5 of By-law 1543-2019, platforms, guards, parapets and landscape planters are permitted beyond the building setbacks in Diagram 5 of By-law 1543-2019 provided they do not project beyond the main walls located at the storey below.
- Rule Q
Despite regulation 40.10.40.10(5), the minimum required height of the first storey shall be 3.8 metres. Prevailing By-laws and Prevailing Sections: (None Apply)
- Older by-law A
Despite regulation 40.10.40.10(2) the permitted maximum height of a building or structure , is specified by the numbers following the symbol HT, as shown on Diagram 4 attached to By-law 1543-2019
- Older by-law B
Despite regulation 40.10.40.40(1), the maximum permitted gross floor area of all buildings and structures on the lot must not exceed 4,800 square metres, of which: (i) Residential uses must not exceed 4,680 square metres; and (ii) Non-residential uses must not exceed 120 square metres
- Older by-law C
Despite regulation 40.5.40.10(1), the height of the building is the distance between Canadian Geodetic Datum elevation of 171.11 metres and the elevation of highest point of the building
- Older by-law D
Despite regulation 40.5.40.10(4) the following may project above the permitted maximum height: (i) elevator overruns, mechanical penthouses, mechanical equipment, and stair enclosures a maximum of 6.1 metres to top of parapet; (ii) terraces and balcony guards, elements of a green roof and insulation and roof surface materials, planters, railings, parapets, and ornamental architectural features, a maximum of 3.0 metres
- Older by-law E
Regulation 40.10.40.1(1) does not apply, except that non-residential uses must be located on the first storey of the mixed use building and must be fronting on Bathurst Street, and a maximum of two dwelling units are permitted to front onto Bathurst Street.
- Older by-law F
Despite regulations 40.10.40.70(2), the required minimum building setbacks are as shown on Diagram 5 of By-law 1543-2019
- Older by-law G
Despite regulations 40.10.40.70(2)(E) and 40.10.40.70(2)(G) a building or structure complying with the heights and setbacks as shown on Diagram 4 and Diagram 5 of By-law 1543-2019 is permitted to penetrate the required 45 degree angular plane.
- Older by-law H
Regulation 40.10.50.10(2) with respect to fencing along the lot line between the Residential Zone category and the subject lands, does not apply
- Older by-law I
Regulation 40.10.50.10(3) with respect to a minimum of 1.5 metres wide strip of soft landscaping along the lot line between the Residential Zone category and the subject lands, does not apply
- Older by-law J
Despite Clause 200.5.1.10(12)(A) the vehicle entrance and exit for a two-way driveway into and out of the building will have a minimum width of 4.5 metres at the garage door and 4.7 metres along the ramp
- Older by-law K
Despite Clause 200.15.1.5(1) accessible parking spaces must be provided below ground on the lot , and be located closest to an accessible elevator connected to the main pedestrian entrance to the building
- Older by-law L
Despite regulation 230.5.10.1(4) and (5) a minimum of 23 long-term bicycle parking spaces and zero short-term bicycle parking spaces must be provided and maintained within the building
- Older by-law M
The provision of dwelling units is subject to the following: (i) a minimum of 25 percent of all dwelling units on the lot must be 2- or more bedroom dwelling units; (ii) a minimum of 10 percent of all dwelling units on the lot must be 3- or more bedroom dwelling units; and (iii) if the calculation of the number of required dwelling units pursuant to (i) and (ii) above results in a number with a fraction, the number is rounded down to the nearest whole number
- Older by-law N
Regulation 40.10.40.50 (1)(B) with respect to a minimum of 40 square metres of outdoor amenity space required to be in a location adjoining or directly accessible to the indoor amenity space , does not apply.
- Older by-law O
Despite regulations 40.10.40.70(1)(A), 40.10.40.70(2)(A) and 40.10.40.70(4)(A) residential uses on the first storey shall be setback a minimum of 2.2 metres from the front lot line .
- Older by-law P
Despite regulations (F) above, 40.10.40.70(2), 40.10.40.60(1), and Diagram 5 of By-law 1543-2019, platforms, guards, parapets and landscape planters are permitted beyond the building setbacks in Diagram 5 of By-law 1543-2019 provided they do not project beyond the main walls located at the storey below.
- Older by-law Q
Despite regulation 40.10.40.10(5), the minimum required height of the first storey shall be 3.8 metres. Prevailing By-laws and Prevailing Sections: (None Apply)
Lot facts
- Area
- 914 m²
- Frontage
- 30.5 m
- Depth
- 30.8 m
- Street
- Rosemary Lane
- Corner lot
- Yes, also on Bathurst St30.8 m along it
- Public lane
- Ln W Bathurst N Dewbourne, 23.5 m along it
- Max height
- 24 m
- Max lot coverage
- —
Around this lot
- Minor variances approved
- 90%43 of 48 decisions
- Garden suite permits
- 1
- Laneway suite permits
- 2
- Multiplex permits
- 4
- Development applications
- 7
Within 300 m, last 10 years. 7 suite and multiplex permits: more than at 67% of Toronto houses (median 3). 48 variance decisions: more than at 83% of Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To alter the development standards for an 8-storey mixed-use building (approved under Site Specific Zoning By-Law 1543-2019) by constructing a vestibule, for the elevator on the mechanical penthouse level, which will lead to the rooftop amenity space.
2010 BATHURST ST · Oct 22, 2025 · 9 m away - Minor varianceRefused
To alter the redevelopment plan for a 17-storey mixed-use building, as approved under Site Specific Zoning By-law 555-2019 (LPAT - Local Planning Appeal Tribunal).
875 EGLINTON AVE W · Jan 11, 2023 · 48 m away - Minor varianceApproved
To amend the site-specific Zoning By-law(s) by increasing the total gross floor area and height of the proposed mixed-use building, and reducing the associated number of parking.
859 EGLINTON AVE W · Oct 20, 2021 · 53 m away - Minor varianceApproved
To alter the existing two-storey mixed-use building by constructing a third storey addition and a rear three-storey addition. The altered building will have commercial on the ground floor and four residential dwelling units above.
999 EGLINTON AVE W · Nov 6, 2019 · 470 m away
Latest activity nearby
- Minor variancePending
To alter the existing three-storey detached dwelling by constructing a basement addition at the southeast corner with a ground floor terrace above, a side (west) ground floor addition (mudroom) with a new second storey balcony above, and a rear third storey balcony with a dormer addition. A portion of the roof will be reconstructed.
7 ROSEMARY LANE · Nov 25, 2026 · 255 m away - Building permit
REV 01: Revision to permit. Structural Changes to ground floor design. NEW 2 STOREY SFD
133 CHILTERN HILL RD · Oct 23, 2026 · 170 m away - Building permit
Steel beam, retaining wall and garage roof deck waterproofing repairs. Major work items include: Steel beam reinforcement; Removal of existing retaining walls and installing new retaining walls; Overburden and waterproofing removal and disposal; Completing localized concrete repairs; and Installing new waterproofing and overburden materials.
630 VESTA DR · Oct 16, 2026 · 300 m away - Building permit
Rooftop Residential Solar PV Installation
27 DEWBOURNE AVE · Oct 15, 2026 · 199 m away - Building permit
proposal for demolition of existing 164.45m² dwelling and construction of a new single detached dwelling
414 RICHVIEW AVE · Oct 5, 2026 · 277 m away - Building permit
Demolition of existing dwelling and construction of a new single detached dwelling. 3 storey house.
414 RICHVIEW AVE · Oct 5, 2026 · 277 m away - Zoning review
Closed
821 EGLINTON AVE W · Sep 30, 2026 · 103 m away - Building permit
NEW 2 STOREY SFD
133 CHILTERN HILL RD · Sep 11, 2026 · 170 m away - Building permit
Interior alterations to existing single detached swelling, including removal and construction of interior partitions and structural modifications
146 CHILTERN HILL RD · Aug 26, 2026 · 190 m away - Building permit
Drain - Proposed interior alterations.
17 ROSTREVOR RD · Aug 24, 2026 · 227 m away
Neighbourhood: Humewood-Cedarvale
About the area around the lot, not the lot itself.
- Nearest station
- Forest Hill Station2 min walk
- Nearest TTC stop
- Eglinton Ave West at Bathurst St1 min walk
- Nearest cycling route
- Old Forest Hill RdSigned Route (No Pavement Markings), 4 min walk
- Nearest traffic count
- 44,750 vehicles in 14 hBathurst St / Eglinton Ave W, 80 m away, Oct 21, 2026
- Serious collisions within 500 m
- 72021–2026, killed or seriously injured: 1 fatal, 5 with pedestrians, 1 with cyclists
- Parks
- Shallmar Parkette6 min walk
- Wembley Parkette7 min walk
- Forest Hill Memorial Cenotaph7 min walk
Schools within 1 km
- ALIVE MONTESSORI AND PRIVATE SCHOOL Private 3 min walk
- FOREST HILL COLLEGIATE INSTITUTE English Public 8 min walk
- THE VILLAGE SHUL SYNAGOGUE & SUPPLMENTARY SCHOOL Private 8 min walk
- ROBBINS HEBREW ACADEMY Private 9 min walk
- CEDARVALE COMMUNITY SCHOOL English Public 10 min walk
- WEST PREPARATORY JR PUBLIC SCHOOL English Public 10 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Humewood-Cedarvale | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $83,000 | $84,500 |
| Households that own their home | 37% | 54% |
| Population (2021) | 13,845 | 16,813 |
| Homes built in 1960 or before | 60% | 29% |
| Homes needing major repairs | 8% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Humewood-Cedarvale | City median |
|---|---|---|
| Assault | 471.6 | 636.3 |
| Robbery | 42.3 | 69.5 |
| Shootings | 12.1 | 10.5 |
| Auto theft | 133 | 192.6 |
| Theft over $5,000 | 18.1 | 46.1 |
| Break and enter | 211.6 | 172.8 |
| Theft from vehicles | 108.8 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.