HousePrecheckCheck an address

2 Carlton StToronto · zoning, lot size and permit records

Also 1 Wood St, 451 Yonge St, 455 Yonge St, 457 Yonge St, 463 Yonge St and 4 more

Commercial residential · CR 7.8 (c4.5; r7.8) SS1 (x398)39.7 × 67.7 m2,424 m²on Carlton Stcorner, also on Yonge Stbacks onto Reverend Porter Lane

Not a home

A commercial or mixed-use building

10 different civic addresses share this parcel, in a commercial zone: shops, offices or a mixed-use building rather than one house. It is not a home for sale, so the house checks and the pre-offer report do not apply.

Looking at a house nearby? What this means for you

  • Shops, offices or a mixed buildingCustomers, deliveries and evening activity; errands within a short walk.
  • Permits or applications open on this parcelRecent records on this lot: 25 179288 STE 13 SA (Site Plan application for an 80-storey tower containing 69,448 square metres of residen..., 2025); 21 216098 STE 13 SB (Draft Plan of Subdivision to create 6 development blocks, 2021). Larger work can mean noise and trucks next door; read what each one is for.
  • 17 development applications open within 300 m, up to 80 storeysNew buildings may go up around here in the next years. More change nearby than at 100% of Toronto houses.
  • Major Transit Station Area: WellesleyThe City plans more homes around the station: good for transit, and more building over time.
N20 m
39.7 m frontage67.7 m deep

Before you offer

From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.

  • 4 building permits open, the oldest since 2007

    Needs a closer look

    Still open in the City's records: 16 158387 (Proposal for interior alterations to existing retail store - "Shoppers Drug Mart" - Con..., 2016, status Inspection); 11 282765 (Permit for exterior repairs to existing mixed use building, 2011, status Inspection); 07 106136 (Plumbing - Interior alterations to existng Unit 103 on ground floor for new retail/offi..., 2007, status Inspection); and 1 more.

    What it means. An open permit can mean work that was never finished or never passed final inspection. After closing, finishing it or closing the file can fall to you.

    How to confirm. Ask the seller for the final inspection records. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details

    City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016)
  • 1 by-law investigation closed in the last two years

    Good to know

    Closed files (Property Standards): 25 181297 PRS 00 IR (Property Standards, 2025).

    What it means. Someone raised an issue here and the City closed the file. Ask the seller what it was about.

    City of Toronto, Toronto Building orders and Municipal Licensing and Standards investigations
  • Work or applications in progress

    Good to know

    Recent records on this lot: 25 179288 STE 13 SA (Site Plan application for an 80-storey tower containing 69,448 square metres of residen..., 2025); 21 216098 STE 13 SB (Draft Plan of Subdivision to create 6 development blocks, 2021).

    What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.

    How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details

    City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications
  • 17 development applications open within 300 m

    Good to know

    17 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 80 storeys. They are listed under Around this lot.

    What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.

    How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details

    City of Toronto, Development Applications

Not in these records

  • Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
  • Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.

History of this lot

93 records on file: more than at 100% of Toronto houses (median 0).

  • Zoning review25 179288 PSPClosed
    Oct 2, 2025 · 2 CARLTON ST
  • By-law investigation25 181297 PRS 00 IRClosed

    Property Standards

    Jun 21, 2025 · 2 CARLTON ST
  • Development application25 179288 STE 13 SAUnder Review

    Site Plan application for an 80-storey tower containing 69,448 square metres of residential GFA and 10,037 square metres of non-residential GFA (Non-res GFA includes 2 levels of retail and 5 levels of office space). The proposal consists of 1,014 residential units, 162 parking spaces, and 1,191 bicycle parking spaces.

    Jun 18, 2025 · 2 CARLTON ST · City file
  • Building permit23 169371Closed

    Proposal for Installation of new electromagnetic locking device on an existing door.

    Jul 6, 2023 · 465 YONGE ST
  • Building permit23 106669Closed

    PROPOSED: INSTALL OF NEW TURNSTILE GATE AND RAILINGS, AND ALTERATIONS TO EXISTING STORAGE AREA DOORS - SHOPPERS DRUG MART

    Feb 24, 2023 · 465 YONGE ST
  • Development application21 216098 STE 13 SBUnder Review

    Draft Plan of Subdivision to create 6 development blocks.

    Sep 22, 2021 · 2 CARLTON ST · City file
  • Building permit20 226652Closed

    To erect and display two illuminated wall signs.****BULKBARN****

    Mar 31, 2021 · 2 CARLTON ST
  • Building permit20 122562Closed

    Proposal for localized waterproofong and concrete repairs to parking garage of existing commercial building.

    Apr 15, 2020 · 2 CARLTON ST
Show 85 older records
  • Building permit19 189829Closed

    Proposed addition of two Electromagnetic Locks on 14th floor of the existing office space

    Jul 22, 2019 · 2 CARLTON ST
  • Building permit19 163596Closed

    Proposal for interior alterations to the 14th floor of existing office "World Education Services"

    Jun 28, 2019 · 2 CARLTON ST
  • Building permit19 164718Closed

    Proposed localized conrete repairs to a ramp for an existing parking garage.

    Jun 4, 2019 · 2 CARLTON ST
  • Building permit19 121326Closed

    Proposed interior alterations for removal of demountable interior partitions (u/s of existing T-bar ceiling) to creat open-layout office, flooring finish replacement, furniture removal and replacement, to existing office space.

    Mar 18, 2019 · 2 CARLTON ST
  • Building permit19 120019Closed

    install mag lock on 11th floor

    Feb 28, 2019 · 2 CARLTON ST
  • Building permit18 213600Closed

    To erect and display three wall signs, to replace existing ones.***VARIOUS TENANTS***

    Sep 26, 2018 · 2 CARLTON ST
  • Zoning review18 158500 ZSVClosed
    May 14, 2018 · 2 CARLTON ST
  • Zoning review18 131624 ZPRClosed
    Mar 20, 2018 · 2 CARLTON ST
  • Building permit17 235845Closed

    REV 01: Revision to expansion tank details and funnel drain connectionProposed backflow prevention device installation for an existing commerical building.

    Nov 27, 2017 · 2 CARLTON ST
  • Zoning review16 232828 PRZClosed
    Nov 7, 2017 · 2 CARLTON ST
  • Building permit17 175497Closed

    Proposed alterations (298m2) to existing retail space on ground floor - Shoppers Drug Mart

    Jun 21, 2017 · 2 CARLTON ST
  • Zoning review17 131518 LTOClosed
    Mar 21, 2017 · 465 YONGE ST
  • Building permit16 229680Closed

    Proposal for waterproofing and localized concrete repair to an underground parking garage in an existing office building.

    Oct 17, 2016 · 2 CARLTON ST
  • Development application16 232828 STE 27 OZClosed

    A revised submission was received on November 6, 2017. The proposal is to develop a 73-storey mixed-use building tower with a 6-storey base building. The base building includes retail uses on the first and second floors, office uses on the third and fourth floors and residential units above. A total of 942 residential units are proposed with a total gross floor area of approximately 76,000 square metres. A total of 162 vehicle and 976 bicycle parking spaces are proposed.

    Oct 4, 2016 · 2 CARLTON ST · City file
  • Building permit16 191724Closed

    Porposed interior alterations to the office space in suite 710 on the 7th floor for the "Ministry of Education"

    Aug 9, 2016 · 2 CARLTON ST
  • Building permit16 147649Closed

    In conjunction with a multistorey building with retail on the first storey on the premises, proposal to erect and display one non-illuminated wall sign on the first storey west elevation. The proposed sign is 1.74 metres vertically by 1.74 metres horizontally at a height of 3.47 meres above grade. **SHOPPERS DRUG MART**

    Jun 11, 2016 · 2 CARLTON ST
  • Building permit16 158387Inspection

    Proposal for interior alterations to existing retail store - "Shoppers Drug Mart" - Convenience Address is 465 Yonge St.

    Jun 3, 2016 · 2 CARLTON ST
  • Building permit14 254346Closed

    Proposal for interior alterations to existing office space on the 6th floor, Unit 600 - Top Hat

    Dec 12, 2014 · 2 CARLTON ST
  • Building permit13 141322Closed

    Proposal for interior alterations to mezzine level of existing office building (38.8m2).

    Apr 30, 2013 · 2 CARLTON ST
  • Building permit13 131484Closed

    Proposal for interior alterations to existing 5th floor of existing office building. "Womens Health In Womens Hands" (45m2)

    Mar 27, 2013 · 2 CARLTON ST
  • Building permit12 153679Closed

    Proposal for interior alterations to existing office space on the 13th floor (suite 1317).

    Apr 30, 2012 · 2 CARLTON ST
  • Building permit12 149325Closed

    Proposal for interior alterations to existing office space on the 1st floor. Work to be done on existing mezzanine level. - Historica Dominion Institute

    Apr 17, 2012 · 2 CARLTON ST
  • Building permit12 121416Closed

    permit for interior alterations to existing office space on floor 15. suite 1517. Dr Chou. - Dentist Office.

    Feb 23, 2012 · 2 CARLTON ST
  • Building permit11 313284Cancelled

    To erect and display eight static copy, non-illuminated projecting signs, five at the easterly and three at the southerly elevation of the building.**Northam Realty Advisors Ltd**

    Dec 16, 2011 · 2 CARLTON ST
  • Building permit11 318697Closed

    Proposal for parking garage concrete repairs in existing mixed-use building (100m2).

    Dec 8, 2011 · 2 CARLTON ST
  • Zoning review11 315642 LTOClosed
    Nov 24, 2011 · 2 CARLTON ST
  • Building permit11 282685Closed

    Permit to convert existing condo sales centre into retail store - BULK BARN. - Unit R3.

    Nov 3, 2011 · 2 CARLTON ST
  • Building permit11 280946Closed

    Revision to existing building permit - Revision to remove stairs from basement level to ground floor. - In fill with concrete deck. Proposal for interior alterations to existing ground floor retail unit, "Bulk Barn". Scope of work includes creating an opening in the floor space for future freight elevator.

    Nov 3, 2011 · 2 CARLTON ST
  • Building permit11 293894Closed

    Proposal for interior alterations to existing office space on the 14th floor - Simply Good Tech.

    Oct 25, 2011 · 2 CARLTON ST
  • Building permit11 282765Inspection

    Permit for exterior repairs to existing mixed use building.

    Oct 14, 2011 · 2 CARLTON ST
  • Building permit11 181402Closed

    This is for interior alterations for "SIGNAL HILL" on the 17th floor. This is for a new office layout.

    May 10, 2011 · 2 CARLTON ST
  • Building permit11 177098Closed

    Proposal for interior alterations to existing office space on the 14th floor.

    Apr 29, 2011 · 2 CARLTON ST
  • Building permit11 148635Closed - Dormant

    Plumbing - Proposal for interior alterations to existing office space on the mezzanine level.

    Mar 29, 2011 · 2 CARLTON ST
  • Building permit11 132235Closed

    permit for interior alterations to existing office space - floor 16 - Pink Triangle Press.

    Mar 23, 2011 · 2 CARLTON ST
  • Building permit10 317247Closed

    Proposal for interior alterations to existing office space on the 15th floor. "Ministry of Education".

    Dec 29, 2010 · 2 CARLTON ST
  • Building permit09 148078Closed

    Proposal to replace 2 boilers in the basement with 3 new water boilers and 2 new steam boilers that are to be installed on the lower penthouse level(18th floor) mechanical room.

    Jun 15, 2009 · 2 CARLTON ST
  • Building permit09 118671Closed

    Proposal to install telecommunication equipment enclosure on rooftop for wireless communication. Bell.

    Apr 1, 2009 · 2 CARLTON ST
  • Building permit09 103773Closed

    Interior alterations to existing office space on the 7th floor. Suite 710.

    Feb 16, 2009 · 2 CARLTON ST
  • Building permit08 212604Closed

    Proposal to conduct repairs to level P4 of parking garage.

    Oct 29, 2008 · 2 CARLTON ST
  • Building permit08 189818Closed

    interior alterations to convert existing vacant office space to dental office - floor 18 - suite 1813 - Dr.Ko

    Aug 12, 2008 · 2 CARLTON ST
  • Building permit08 163056Closed

    Interior Alteration to the Suite 1800A

    Jun 9, 2008 · 2 CARLTON ST
  • Building permit08 161244Closed

    HVAC - Interior alterations to portions to existing Ground Floor sales office . Tridel Sales Office

    May 28, 2008 · 2 CARLTON ST
  • Building permit07 256224Closed

    entrance lobby heat/cool unit replacement

    Aug 30, 2007 · 2 CARLTON ST
  • Building permit07 238812Closed

    Interior alterations to existing office on the 6th floor. Suite 600.

    Jul 23, 2007 · 2 CARLTON ST
  • Zoning review07 117097 ZPRClosed
    Mar 20, 2007 · 2 CARLTON ST
  • Building permit07 110311Closed

    Install 2 maglocks on ground floor.

    Feb 21, 2007 · 2 CARLTON ST
  • Building permit07 106136Inspection

    Plumbing - Interior alterations to existng Unit 103 on ground floor for new retail/office. Tenant - "Flight Centre".

    Feb 19, 2007 · 2 CARLTON ST
  • Building permit06 196671Inspection

    HVAC - Interior alterations to ground floor to convert existing multiple retail units into 1 retail unit (New Shoppers Drug Mart). Convenience address - 425 Yonge St.

    Jan 19, 2007 · 2 CARLTON ST
  • Zoning review07 102829 ZSVClosed
    Jan 16, 2007 · 2 CARLTON ST
  • Zoning review06 198324 ZPRClosed
    Dec 15, 2006 · 2 CARLTON ST
  • Building permit05 169638Closed

    HVAC - Interior alterations on 15th floor (approx. 195sq. m). Ministry of Education offices. - Interior Alterations

    Sep 7, 2005 · 2 CARLTON ST
  • Building permit05 107981Closed

    Make interior alterations to existing restaurant for condominium sales office.

    Mar 17, 2005 · 2 CARLTON ST
  • Zoning review05 102766 ZSVClosed
    Jan 17, 2005 · 2 CARLTON ST
  • Building permit04 125430Closed

    garage rehabilitation - p2 and p3

    Jun 9, 2004 · 2 CARLTON ST
  • Zoning review03 186985 ZPRClosed
    Oct 20, 2003 · 2 CARLTON ST
  • Zoning review03 177412 LTOClosed
    Sep 22, 2003 · 2 CARLTON ST
  • Building permit03 132414Closed

    interior alterations/partitions and change of use

    Jul 7, 2003 · 2 CARLTON ST
  • Building permit03 103619Closed

    MAKE INTERIOR ALTERATIONS TO 11TH & 12TH FLOORS TENANT: MINISTRY OF EDUCATION

    Feb 6, 2003 · 2 CARLTON ST
  • Building permit02 194145Closed

    make interior alterations to portions of 7th, 13, 15th, floors tenant: ministry of education

    Dec 13, 2002 · 2 CARLTON ST
  • Building permit02 155179Closed

    install 2 maglocks on 6th floor; 2 maglocks on 10th floor; and 2 maglocks on 15th floor existing office.

    Jul 18, 2002 · 2 CARLTON ST
  • Zoning review02 035015 ZSVClosed
    Jan 25, 2002 · 2 CARLTON ST
  • Zoning review02 100316 ZPRClosed
    Jan 3, 2002 · 2 CARLTON ST
  • Zoning review01 203365 LTOClosed
    Dec 17, 2001 · 2 CARLTON ST
  • Building permit01 164380Closed

    install telecommunication systems with associates mechanical shelter on roof.

    Aug 2, 2001 · 2 CARLTON ST
  • Zoning review01 035522 ZSVClosed
    May 16, 2001 · 2 CARLTON ST
  • Zoning review01 112935 000Closed
    Feb 23, 2001 · 2 CARLTON ST
  • Building permit00 159780Closed

    INSTALL CELLULAR ANTENNAS ON ROOF. EXISTING- RETAIL STORE, RESTAURANT, RESTAURANT AND CLINIC BUILIDNG PROPOSED- SAME

    Jun 14, 2000 · 2 CARLTON ST
  • Building permit00 141027Closed

    h.v.a.c. install new h.v.a.c. system on ground floor for new restaurant (under 30 seats). tenant: baroli cafe. cost included in 141019 edc

    May 9, 2000 · 2 CARLTON ST
  • Building permit00 141019Closed

    make interior alterations to ground floor for new restaurant (under 30 seats). tenant: baroli cafe. hold for health dept. approval. edc

    May 9, 2000 · 2 CARLTON ST
  • Zoning review00 012425 LTOClosed
    Apr 20, 2000 · 2 CARLTON ST
  • Zoning review99 022672 LTOClosed
    Jul 22, 1999 · 2 CARLTON ST
  • Building permit98 024578Closed

    MAKE REPAIRS TO BUILDING EXTERIOR WALL, COLUMNS AND SLABS. EDC (FEES CHARGED RE: $60 ADMIN., $60 1 HOUR MINIUMUM.

    Dec 23, 1998 · 2 CARLTON ST
  • Building permit98 017641Closed

    INSTALL H.V.A.C SYSTEM ON PORTION OF 1ST FLOOR 'SHOPPERS' DRUG MART' COST INCL. UNDER FILE #413006(B LG

    Jun 25, 1998 · 2 CARLTON ST
  • Zoning review98 026264 LTOClosed
    Jun 11, 1998 · 2 CARLTON ST
  • Zoning review96 025044 LTOClosed
    Jun 4, 1996 · 2 CARLTON ST
  • Zoning review96 024464 LTOClosed
    Jan 18, 1996 · 463 YONGE ST
  • Zoning review93 025416 LTOClosed
    Aug 4, 1993 · 7 WOOD ST
  • Zoning review92 025084 LTOClosed
    Jan 16, 1992 · 2 CARLTON ST
  • Zoning review91 027139 LTOClosed
    Dec 9, 1991 · 465 YONGE ST
  • Zoning review90 028521 LTOClosed
    Jun 4, 1990 · 471 YONGE ST
  • Zoning review90 028199 LTOClosed
    Feb 26, 1990 · 457 YONGE ST
  • Zoning review90 028123 LTOClosed
    Feb 2, 1990 · 2 CARLTON ST
  • Zoning review87 030207 LTOClosed
    Jun 23, 1987 · 2 CARLTON ST
  • Zoning review83 026224 LTOClosed
    Aug 30, 1983 · 2 CARLTON ST
  • Zoning review81 030654 LTOClosed
    Sep 8, 1981 · 2 CARLTON ST

Check before you build

  • Site-specific exception 900.11.10(398)

    Needs a closer look

    21 site-specific rules apply to this lot. They can override the standard rules on this page.

    Zoning By-law 569-2013, Chapter 900
Exception 900.11.10(398)Applies

These parts of the exception apply to this lot's address.

  1. Rule A

    On the lands municipally known as 2 Carlton Street if the requirements of Section 8 and Schedule A of By-law 758-2021(OLT) are complied with, then a mixed use building or structure may be constructed in compliance with regulations

  2. Rule B

    to (U) below: (B) Despite Regulations 40.5.1.10(3) and 40.10.40.40(1),the maximum permitted gross floor area of the mixed use building erected on the lands shown on Diagram 3 must not exceed 81,000 square metres, of which: (i) The minimum gross floor area devoted to office uses shall be 8,282 square metres and the maximum gross floor area devoted to office uses shall be 14,554 square metres; (ii) The maximum gross floor area devoted to residential uses shall be 72,000 square metres; (iii) No residential gross floor area may be permitted above the Canadian Geodetic Datum elevation of 344.2 metres; and (iv) The minimum gross floor area devoted to retail uses shall be 800 square metres and the maximum gross floor area devoted to retail uses shall be 1800 square metres

  3. Rule C

    A minimum of 10 percent of the total number of dwelling units shall have three bedrooms and an additional 30 percent of the total number of dwelling units shall have two or more bedrooms

  4. Rule D

    Despite Regulation 40.5.40.10(1) and (2), for the purposes of By-law 758-2021(OLT), the height of a building or structure is measured as the vertical distance between the Canadian Geodetic Datum elevation of 102.2 metres and the highest point of the building or structure , except for those elements otherwise expressly permitted in By-law 758-2021(OLT)

  5. Rule E

    Despite Regulations 40.10.40.10(1), no portion of the mixed use building may exceed the maximum height in metres specified by the number following the letters "HT" on Diagram 3 of By-law 758-2021(OLT)

  6. Rule F

    Despite (E) above, Clause 40.5.40.10 and Regulation 40.10.40.10(1), the following building elements and structures are permitted to project above the permitted maximum heights shown on Diagram 3 of By-law 758-2021(OLT), as follows: (i) Architectural features, air intake and air handling units, communication equipment, cooling tower, elevator overruns, exit stairs, stairs, stair enclosures, fences, flues, landscape and public art features, noise attenuation walls, pipes, window washing equipment, and elevator machine room may project up to a maximum of 5.0 metres above the permitted maximum heights; (ii) Awnings, chimneys, bicycle racks, bollards, guardrails, lighting fixtures, Planters, ornamental elements, cornices, platforms, railings, retaining walls, parapets, railings, balustrades, roof drainage systems, screens, stacks, terraces, green roof , trellises, insulation and roof surface materials, vents, wind mitigation screens, and window sills, may project up to a maximum of 2.5 metres above the permitted maximum heights; (iii) Elements or structures on any portion of a roof used for outside or open air recreation, including required residential amenity space may project up to a maximum of 3.0 metres above the permitted maximum heights. (iv) Despite subsections F (i), (ii) and (iii) above, Clause 40.5.40.10 and Regulation 40.10.40.10(1), no building elements and structures shall be located above the Canadian Geodetic Datum elevation of 349.2 metres within the area denoted as HT 247.0 on Diagram 3, above the Canadian Geodetic Datum elevation of 344.2 metres within the area denoted as HT 242.0 on Diagram 3, above the Canadian Geodetic Datum elevation of 341.4 metres within the area denoted as HT 239.2 on Diagram 3, above the Canadian Geodetic Datum elevation of 338.6 metres within the area denoted as HT 236.4 on Diagram 3, above the Canadian Geodetic Datum elevation of 335.8 metres within the area denoted as HT 233.6 on Diagram 3, above the Canadian Geodetic Datum elevation of 333.0 metres within the area denoted as HT 230.8 on Diagram 3, and above the Canadian Geodetic Datum elevation of 330.2 metres within the area denoted as HT 228 on Diagram 3, except for the following: (a) Architectural features, air intake and air handling units, chimneys, lighting fixtures, communication equipment, flues, window washing equipment, up to a maximum height of 5 metres; and (b) Guardrails, roof drainage, terraces, green roof , trellises, screens, cornices, railings, insulation and roof surface materials up to a maximum of 2.5 metres; (v) Despite subsections F (i), (ii), (iii) and (iv) above, Clause 40.5.40.10 and Regulation 40.10.40.10(1), no building elements and structures shall be located above the Canadian Geodetic Datum elevation of 353.3 metres within the area denoted as HT 251.1 on Diagram 3 except for the following: (a) Air intake and air handling units, lighting fixtures, communication equipment, and flues up to a maximum height of 2.5 metres; and (b) Window washing equipment up to a maximum of 5 metres

  7. Rule G

    Despite Regulations 40.5.40.70, 40.10.40.70(1) and Section 600.10, the minimum required building setbacks and are shown on Diagram 3 of By-law 758-2021(OLT)

  8. Rule H

    Despite Regulations 5.10.40.70(1), 40.10.40.60, 600.10 and (G) above, the following building elements and structures are permitted to encroach into required building setbacks shown on Diagram 3 of By-law 758-2021(OLT), as follows: (i) Awnings and canopies may encroach up to a maximum of 1.5 metres; (ii) Chimneys, landscape and public art features, planters, trellises, screens, wind mitigation screens, and wheel chair ramps, and their associated structures , may encroach up to a maximum of 2.5 metres; (iii) Architectural features, eaves, fences, finials, guardrails, lighting fixtures, ornamental elements, parapets, railings, window sills, may encroach up to a maximum of 1.0 metres; (iv) Stairs and stair enclosures may encroach up to a maximum of 5.5 metres; (v) Window washing and building maintenance equipment, may encroach into the required building setbacks for all buildings and structures up to a maximum of 5.5 metres when in use; and (vi) Bay windows may encroach into the required building setbacks within the areas specified on Diagram 3 as "Bay Window Zone" to a maximum of 1.5 metres

  9. Rule I

    Despite Clause 40.10.40.50, amenity space must be provided and maintained on the lot as follows: (i) 1.6 square metres of indoor amenity space shall be provided for each dwelling unit ; and (ii) 0.6 square metres of outdoor amenity space shall be provided for each dwelling unit , of which: (a) at least 40.0 square metres is outdoor amenity space in a location adjoining or directly accessible to the indoor amenity space ; and (b) no more than 25 percent of the outdoor component may be a green roof

  10. Rule J

    Despite Regulations 40.10.100.10(1) (A) and (C) with respect to vehicle access, one vehicular access is permitted from Wood Street and one vehicular access is permitted from Reverend Porter Lane and regulation 200.5.1.10(12)(c) shall not apply

  11. Rule K

    Despite Regulations 200.5.10.1(1) and Table 200.5.10.1, parking spaces must be provided on the lot as follows: (i) A minimum of 0.125 parking spaces per dwelling unit for residents of the mixed use building ; (ii) 16 Car Share parking spaces are required for use by occupants of the mixed use building ; (iii) A minimum of 0.03 parking spaces per 100 square metres of non-residential gross floor area are required for non-residential uses and residential vistors in the mixed use building ; (iv) The parking spaces may be located in an "automated parking system"; (v) parking spaces provided within an "automated parking system" will not be subject to clause 200.5.1.10. and must have minimum dimensions as follows: (a) Length - 5.4 metres; (b) Width - 2.4 metres; and (c) Vertical clearance - 2 metres; (vi) Parking spaces required in (i) through (iii) above may be provided in a stacked parking space ; and (vii) For the purposes of this exception, "automated parking system" means a mechanical system for the purpose of parking and retrieving cars without drivers in the vehicle during parking and without the use of ramping or driveway aisles, and which may include but is not limited to, a vertical lift and the storage of cars on parking pallets. Automated manoeuvring of other vehicles may be required in order for cars to be parked or to be retrieved. Parking pallets and parking elevators will not conform to the parking space and accessible parking space dimensions set out in City of Toronto Zoning By-law 569-2013 and above in By-law 758-2021(OLT). For clarity, parking pallets will be considered as a parking space or as an accessible parking space for the purpose of determining compliance with the requirements in City of Toronto Zoning By-law 569-2013 and relevant clauses in By-law 758-2021(OLT).

  12. Rule L

    Despite Regulations 200.5.1.10(2)(A) and (D), electric vehicle infrastructure, including electrical vehicle supply equipment may encroach up to a maximum of 0.5 metres, and does not constitute an obstruction to a parking space

  13. Rule M

    Accessible parking spaces shall be provided on the lot in accordance with the following requirements: (i) minimum length of 5.6 metres; (ii) minimum width of 3.4 metres; (iii) minimum vertical clearance of 2.1 metres; and (iv) the entire length of accessible parking spaces must be adjacent to a 1.5 metres wide accessible barrier free aisle or path

  14. Rule N

    Despite sections 200.15.1(4) and 200.15.10(1) a minimum of five (5) accessible parking spaces must be located closest to a barrier free pedestrian entrance within the parking garage providing access to an elevator serving the ground floor

  15. Rule O

    "Car-share" parking spaces are permitted on the lot in accordance with the following: For the purposes of this exception, "car share" means the practice where a number of people share the use of one or more cars that are owned by a profit or nonprofit car sharing organization and where the organization may require that use of cars to be reserved in advance, charge fees based on time and/or kilometres driven, and set membership requirements of the car sharing organization, including the payment of a membership fee which may or may not be refundable, and "car share parking space" means a parking space exclusively reserved and used for car share purposes where the vehicle is accessible to at least the occupants of the building

  16. Rule P

    Despite Clause 220.5.10.1 loading spaces shall be provided on the lot , as follows: (i) One – loading space – Type 'G' (ii) One – loading space – Type 'B'; and (iii) One – loading space – Type 'C'

  17. Rule Q

    Despite Regulation 230.5.1.10(9), (10) and 230.40.1.20 (1), bicycle parking spaces must be provided and maintained on the lot in accordance with the following: (i) Long-term and short-term bicycle parking spaces may be provided in horizontal, vertical and/or stacked bicycle parking spaces , or any combination thereof; (ii) Long-term bicycle parking spaces and short-term bicycle parking spaces may be located any floor of a building below grade and may be located more than 30 metres from a pedestrian entrance; (iii) Despite subsection P(ii) above, a minimum of 400 long-term bicycle parking spaces will be located on the first level below grade, inclusive of a mezzanine level; (iv) Short-term and long-term bicycle parking spaces and/or stacked bicycle parking spaces may be located within a secured room, enclosure or any combination thereof; and (v) Short-term bicycle parking spaces and/or stacked bicycle parking spaces may be located indoors or outdoors

  18. Rule R

    Despite Regulation 230.5.1.10(4) and (5) stacked bicycle parking spaces must have minimum dimensions as follows: (i) minimum length of 1.8 metres; (ii) minimum width of 0.6 metres, and (iii) minimum vertical clearance for each bicycle parking space of 1.0 metres

  19. Rule S

    Regulation 40.10.40.1(1) with respect to location of commercial uses in a mixed use building , does not apply

  20. Rule T

    Despite regulation 40.10.40.10(5) related to the minimum height of first storey , the first storey , measured between the floor of the first storey and the ceiling of the first storey shall be 4.0 metres

  21. Rule U

    None of the provisions of this By-law or By-law 569-2013, as amended, shall apply to prevent a Construction Office/Sales Office on the lands identified on Diagram 1 of By-law 758-2021(OLT), where a Construction Office/Sales Office means buildings , structures , facilities or trailers, or portions thereof, used for the purpose of the administration and management of construction activity and/or for selling or leasing dwelling units and non-residential gross floor area on the lands identified on Diagram 1 of By-law 758-2021(OLT)

By-law 569-2013, Chapter 900

Lot facts

Area
2,424 m²
Frontage
39.7 m
Depth
67.7 m
Street
Carlton St
Corner lot
Yes, also on Yonge St67.7 m along it
Public lane
Reverend Porter Lane, 80.9 m along it
House footprint
2,330 m²roof up to 77 m
Back yard
0 mhouse to rear lot line
Side yards
0.1 m and 0.8 mhouse to side lot lines; 0 is a shared wall
Buildings on the lot
6house, garage, sheds
Max height
61 m
Max lot coverage
—

House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.

  • Site and Area Specific Policy 382. The Official Plan has a policy for this site or area that varies the general rules. Read it before relying on zoning alone. Source
  • Major Transit Station Area: Wellesley. The lot is inside the Wellesley Major Transit Station Area approved by the Province (Site and Area Specific Policy 602). Source
  • Downtown Plan Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
  • Priority retail street: Carlton Street, Yonge Street. The lot is on a priority retail street. In this zone at least 60% of the ground floor along that street must hold retail, restaurants, offices or similar uses, with entrances within 5 m of the lot line and 60% of the ground floor wall in windows or doors. Source
  • Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
  • Zone CR 7.8 (c4.5; r7.8) SS1 (x398) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source

Around this lot

Minor variances approved
94%17 of 18 decisions
Garden suite permits
0
Laneway suite permits
0
Multiplex permits
1
Development applications
35

Within 300 m, last 10 years. 1 suite and multiplex permits: no more than at most Toronto houses (median 3). 18 variance decisions: no more than at most Toronto houses (median 19).

Recent variance decisions in the same zone

  • Minor varianceApproved

    To permit the existing entertainment place of assembly (nightclub) use within the two-storey commercial building.

    508 CHURCH ST · Sep 9, 2026 · 327 m away
  • Minor varianceApproved

    To alter the development standards (as approved under Site Specific Zoning By-law 88-2023(OLT)) for the 40-storey mixed-use building (which is currently under construction), by increasing the residential gross floor area, building height (41-storeys; 123.5 m to 127.6 m and 129.2 m to 133.6 m), and the height of the elevator overrun projection. There will be a total of 516 residential dwelling units on this site.

    20 MAITLAND ST · Apr 1, 2026 · 282 m away
  • Minor varianceApproved

    To alter the development standards for the previously approved 32-storey and 46-storey, two-tower mixed-use, purpose built rental development with 30 Percent affordable dwelling units and a child care center (approved under Site Specific Zoning By-law 1096-2021), by redistributing the building heights to 33 and 41storeys, increasing podium setbacks, reducing street wall heights, reducing the size of podium to create two separate buildings connected only below grade, decreasing the amount of indoor amenity space, reducing the number of two or more bedroom units, eliminating the resident and non-residential parking requirements, and decreasing the amount of residential visitor spaces. Site plan control application 19 127591 STE 13 SA is under review.

    27 GROSVENOR ST · Jul 30, 2025 · 206 m away
  • Minor varianceApproved

    To alter the development standards for the 40-storey mixed-use building (as approved under Site Specific Zoning By-law 88-2023) by increasing the total number of residential dwelling units, the overall and residential gross floor area, the building height, and the maximum projection height of an elevator overrun. Also, to reduce the total number of residential dwelling units with 3 or more bedrooms, the required amenity space, and the total number of residential visitor parking spaces. The new 45-storey mixed-use building (excluding the mechanical penthouse) will have a total of 572 residential dwelling units, 78 residential parking spaces, and 7 residential visitor parking spaces. This is currently undergoing Site Plan Control (Application Number 19 240163 STE 13 SA).

    26 MAITLAND ST · Apr 23, 2025 · 289 m away
  • Minor varianceApproved

    To alter the development standards (as approved under Site Specific Zoning By-law 193-2024(OLT)), for a new 59-storey mixed-use building, by permitting a private student residence use on this lot. There will be a total of 587 residential dwelling units within this building.

    510 YONGE ST · Mar 19, 2025 · 209 m away

Latest activity nearby

  • Minor variancePending

    To alter the development standards for the previously approved two-tower mixed-use development (approved under Site Specific Zoning By-law 1096-2021), by reducing the height of a portion of the first storey (to include a mezzanine level located between the first and second storeys). There will be a total of 767 rental dwelling units (of which 30.4% (233 units) will be affordable rental units), as well as a childcare center on this lot. A related Site Plan Control application (under File Number 19 127591 STE 13 SA) has received Notice of Approval conditions.

    27 GROSVENOR ST · Nov 25, 2026 · 206 m away
  • Zoning review

    Closed

    450 YONGE ST · Nov 23, 2026 · 49 m away
  • Building permit

    Proposal for interior alterations to lobby, main corridor, bar & restaurant at ground floor.

    475 YONGE ST · Nov 17, 2026 · 83 m away
  • Building permit

    INTERIOR ALTERATIONS TO GROUND FLOOR VACANT COMMERCIAL UNIT 3 FOR PROPOSED COFFEE SHOP: 'DARKHORSE ESPRESSO'

    484 YONGE ST · Nov 16, 2026 · 124 m away
  • Building permit

    Interior alteration to combine an existing gym room and adjacent pool room into one fitness room.

    475 YONGE ST · Nov 10, 2026 · 83 m away
  • Building permit

    1 projecting sign**SHIRIN JAAN**

    508 YONGE ST · Nov 5, 2026 · 203 m away
  • Zoning review

    Closed

    879 BAY ST · Nov 4, 2026 · 291 m away
  • Building permit

    1 Wall Sign

    522 YONGE ST · Nov 2, 2026 · 234 m away
  • Building permit

    Proposal for interior alterations to install 5 phone booths, sprinkler connections and new strobe lights

    777 BAY ST · Nov 2, 2026 · 239 m away
  • Building permit

    1 Wall Sign*****XI NOODLE HOUSE*****

    510 YONGE ST · Nov 2, 2026 · 209 m away

Neighbourhood: Church-Wellesley

About the area around the lot, not the lot itself.

Nearest station
College Station3 min walk
Nearest TTC stop
Yonge St at Carlton St North Side - College Station1 min walk
Nearest cycling route
Bay StSharrows - Arterial - Connector, 4 min walk
Nearest traffic count
11,095 vehicles in 8 hCollege St / Yonge St / Carlton St, 50 m away, Aug 1, 2023
Serious collisions within 500 m
122021–2026, killed or seriously injured: 2 fatal, 8 with pedestrians, 3 with cyclists
Parks
Alexander Street Parkette3 min walk
Joseph Sheard Parkette3 min walk
College Park3 min walk

Schools within 1 km

  • THE YMCA ACADEMY SECONDARY SCHOOL Private 4 min walk
  • TAIE INTERNATIONAL INSTITUTE SCHOOL Private 5 min walk
  • TORONTO METROPOLITAN UNIVERSITY - THEATRE SCHOOL University 5 min walk
  • CHURCH ST JR & NATIVE LEARNING CTR English Public 6 min walk
  • LE COLLEGE FRANCAIS - CARLTON CAMPUS Private 7 min walk
  • NATIONAL BALLET SCHOOL - MAISON STAINES HOUSE & SALLE CURRIE HALL Private 7 min walk

Being near a school does not mean the lot is in its catchment; check with the board.

2021 Census

FigureChurch-WellesleyMedian neighbourhood
Median household income (2020)$60,400$84,500
Households that own their home24%54%
Population (2021)22,32016,813
Homes built in 1960 or before15%29%
Homes needing major repairs5%7%

Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.

Police-reported crime, 2025

Per 100,000 peopleChurch-WellesleyCity median
Assault1264.6636.3
Robbery93.269.5
Homicide3.35.3
Auto theft46.6192.6
Theft over $5,000106.546.1
Break and enter146.4172.8
Theft from vehicles206.3188.1

Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.

Something here not right?

Sources

  • Building permits on this lot since 2000: Permits issued or applied for since about 2000, with status.
  • Committee of Adjustment files since 2001: Minor variances and consents (lot splits) on this lot and nearby, with decisions.
  • Development applications: Rezoning, site plan, subdivision and condominium applications.
  • Preliminary zoning reviews: Zoning reviews requested before a permit or variance application.
  • Zoning and overlays: Zoning By-law 569-2013 zone, height, coverage, policy area, parking, rooming house, priority retail street and downtown setback overlays.
  • Lot boundary, street and lane: Lot polygon, its addresses, the street it fronts, corner and public lane contact, with frontage and depth measured from the boundary; City of Toronto land in City use, which is not a home.
  • House and yards: Footprint and roof height of the house and other buildings, and the yard behind the house, from the City's 3D Massing (updated yearly, illustrative).
  • City trees in front of the lot: City-owned trees on the street allowance at this address, with species and trunk diameter. Private trees on the lot are not in open data.
  • Heritage: Heritage Register (listed and designated properties), Official Plan Amendment 720 properties and properties removed from the Register under the 2022 two-year limit.
  • TRCA regulated area: Valleys, floodplains, shorelines and wetlands regulated by the Toronto and Region Conservation Authority.
  • Ravines and natural features: Ravine and Natural Feature Protection area (Chapter 658, map last published 2019), Natural Heritage System and Environmentally Significant Areas.
  • Official Plan policies: Site and Area Specific Policies, Secondary Plans and Major Transit Station Areas covering the lot.
  • Rooming houses, short-term rentals and rental buildings: Multi-tenant house licences, short-term rental registrations and RentSafeTO evaluations at this address.
  • Neighbourhood context: Neighbourhood, 2021 Census figures, police-reported crime rates, schools, parks, TTC stops, cycling routes, serious collisions and traffic counts nearby. Area context only, not a finding about the lot.
  • Orders and by-law investigations: Outstanding Toronto Building orders, and by-law investigations open now or closed in the last two years. Fire and Public Health orders and older closed files are not published.
  • Address points: loaded Nov 22, 2026, published Nov 20, 2026
  • Toronto Building orders: loaded Nov 28, 2026, published Nov 27, 2026
  • Neighbourhood Profiles, 2021 Census: loaded Oct 14, 2026, published Oct 6, 2023
  • Street centrelines: loaded Nov 22, 2026, published Nov 20, 2026
  • City-owned land: loaded Nov 22, 2026, published Nov 16, 2026
  • Committee of Adjustment open applications: loaded Nov 28, 2026, published Nov 27, 2026
  • Committee of Adjustment decisions: loaded Nov 28, 2026, published Nov 27, 2026
  • Committee of Adjustment decisions 2001-2016: loaded Oct 14, 2026, published Feb 20, 2026
  • Collisions with people killed or seriously injured (Toronto Police Service): loaded Nov 22, 2026, published Nov 21, 2026
  • Neighbourhood crime rates (Toronto Police Service): loaded Oct 14, 2026, published Feb 20, 2026
  • Cycling network: loaded Nov 22, 2026, published Nov 16, 2026
  • Development applications: loaded Nov 28, 2026, published Nov 28, 2026
  • Environmentally Significant Areas: loaded Oct 14, 2026, published Mar 16, 2026
  • Green spaces: loaded Nov 15, 2026, published Nov 10, 2026
  • Heritage register: loaded Oct 14, 2026, published Sep 1, 2026
  • Former heritage listings: loaded Oct 14, 2026, published Jul 3, 2025
  • Official Plan Amendment 720 heritage list: loaded Oct 14, 2026, published Sep 1, 2026
  • 3D Massing building footprints: loaded Oct 14, 2026, published Dec 2, 2025
  • By-law investigation addresses: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigation deficiencies: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigations: loaded Nov 28, 2026, published Nov 27, 2026
  • Major Transit Station Areas: loaded Oct 14, 2026, published Feb 3, 2026
  • Natural Heritage System: loaded Oct 14, 2026, published Mar 16, 2026
  • Neighbourhoods: loaded Oct 14, 2026, published Feb 20, 2026
  • Property boundaries: loaded Nov 27, 2026, published Nov 27, 2026
  • Active building permits: loaded Nov 28, 2026, published Nov 27, 2026
  • Cleared building permits: loaded Nov 28, 2026, published Nov 27, 2026
  • Cleared building permits 2000-2016: loaded Oct 14, 2026, published Jul 8, 2025
  • Preliminary zoning reviews: loaded Nov 28, 2026, published Nov 27, 2026
  • Ravine and natural feature protection: loaded Oct 14, 2026, published Jul 23, 2019
  • RentSafeTO evaluations: loaded Nov 28, 2026, published Nov 27, 2026
  • Multi-tenant house licences: loaded Nov 28, 2026, published Nov 27, 2026
  • Site and Area Specific Policies: loaded Oct 14, 2026, published Mar 16, 2026
  • School locations: loaded Oct 14, 2026, published May 27, 2026
  • Secondary Plans: loaded Oct 14, 2026, published Mar 16, 2026
  • Street trees: loaded Oct 14, 2026, published Jun 4, 2026
  • Short-term rental registrations: loaded Nov 28, 2026, published Nov 27, 2026
  • Traffic counts at intersections: loaded Nov 22, 2026, published Nov 21, 2026
  • TRCA regulation limit: loaded Oct 14, 2026, published Apr 29, 2026
  • TTC stops (GTFS): loaded Nov 8, 2026, published Nov 5, 2026
  • Zoning by-law: loaded Oct 14, 2026, published Feb 20, 2026
  • Lot coverage overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Height overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Parking zone overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Policy area overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Priority retail streets: loaded Oct 14, 2026, published Feb 20, 2026
  • Rooming house overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Zoning setbacks: loaded Oct 14, 2026, published Feb 20, 2026

Contains information licensed under the Open Government Licence – Toronto. TRCA regulation limit © TRCA.

Screening tool based on City of Toronto and TRCA open data. Not a zoning review or legal opinion. Site-specific exceptions, amendments not yet in the open data, minor variances and other by-laws can change the answer. Confirm with a Preliminary Project Review or Zoning Certificate from Toronto Building before buying or designing.

Flag an error

What is not right?

The problem

The records come from the City's open data; we check each flag against them. Your email is used only to answer this.