Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
Work or applications in progress
Good to knowRecent records on this lot: 25 214388 (Deferred Fees from folder 24 214388 (RSN-5514027) ZoningProcess RSN 76588344, 2025).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications1 development application open within 300 m
Good to know1 rezoning, site plan, subdivision or condominium application within 300 m, submitted in the last 10 years, is not closed yet. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
22 records on file: more than at 100% of Toronto houses (median 0).
- Building permit26 139795Approved
The alternative solution is for the proposed standpipe system within this building to be a Class I type system with 65 mm hose connections installed in the exit stairs.
Apr 7, 2026 · 17 ST ANDREW ST - Building permit26 131441Cancelled
The alternative solution is for the proposed standpipe system within this building to be a Class I type system with 65 mm hose connections installed in the exit stairs. Main permit 24 214388See attached letter, "260220 CodeNext Alternative Solution Report 26P0064" dated February 20, 2026 for full details.
Mar 18, 2026 · 17 ST ANDREW ST - Building permit24 214388Closed
Conditional Permit - Part Permit - Proposal for a five-storey mixed-use building having 72 residential units and retail space.
Feb 5, 2026 · 17 ST ANDREW ST - Building permit24 247582Closed
Proposal to demolish exsting mixed use building and construct a new five-storey mixed-use building having 72 residential units and retail space
Jun 26, 2025 · 17 ST ANDREW ST - Building permit25 214388Open
Deferred Fees from folder 24 214388 (RSN-5514027) ZoningProcess RSN 76588344
May 15, 2025 · 17 ST ANDREW ST - Zoning review22 236341 PSPClosedDec 12, 2022 · 17 ST ANDREW ST
- Development application22 236341 STE 11 SAClosed
Site Plan application for a 5-storey mixed-use building (with mechanical penthouse) having an overall height of 21 metres. A total of 72 residential units and 291 square metres of non-residential floor area will be provided.
Dec 5, 2022 · 17 ST ANDREW ST · City file - Zoning review19 232278 PRZClosedNov 29, 2021 · 17 ST ANDREW ST
Show 14 older records
- Development application19 232278 STE 11 OZClosed
Zoning By-law Amendment to facilitate the development of a 5-storey mixed-use building (with mechanical penthouse) having an overall height of 21 metres. A total of 77 residential units and 171.5 square metres of non-residential floor area will be provided.
Oct 4, 2019 · 17 ST ANDREW ST · City file - Zoning review15 199903 LPRClosedJul 31, 2015 · 17 ST ANDREW ST
- Zoning review14 188255 LTOClosedJul 10, 2014 · 17 ST ANDREW ST
- Building permit14 144228Closed
St. Andrew Poultry: Interior alterations to convert portion of existing retail area for accessory take-out restaurant counter sales
May 16, 2014 · 17 ST ANDREW ST - Zoning review12 275181 ZPRCancelledNov 7, 2012 · 17 ST ANDREW ST
- Zoning review09 197116 ZPRClosedDec 16, 2009 · 17 ST ANDREW ST
- Building permit09 179098Closed
INSTALLATION OF A GREASE INTERCEPTOR IN THE BASEMENT FOR THE MEAT SHOP LOCATED ON THE GROUND FLOOR AND THE INSTALLATION OF A 3/4" BACKFLOW PREVENTION DEVICE.
Nov 12, 2009 · 17 ST ANDREW ST - Building permit00 348212Revision Issued
Revision to alter approved plans to change the layout of one of the dwelling units and block off window.
Oct 26, 2005 · 17 ST ANDREW ST - Building permit05 109750Closed
Demolish detached warehouse building. Existing Use: Warehouse Bldg. Proposed Use: Vacant Land
Jun 8, 2005 · 17 ST ANDREW ST - Zoning review05 132677 PSPCancelledMay 16, 2005 · 17 ST ANDREW ST
- Zoning review05 108799 ZPRClosedFeb 14, 2005 · 17 ST ANDREW ST
- Zoning review02 177936 LTOClosedOct 2, 2002 · 17 ST ANDREW ST
- Building permit02 128845Closed
make alterations to existing poultry packing plant by adding 4 new window openings on east elevation and 2 new window openings on west elevation. tenant: kensington packing corporation.
Apr 25, 2002 · 17 ST ANDREW ST - Building permit00 356177Closed
Install h.v.a.c. system for proposed addition at rear. cost incl. 00 - 348212
Dec 18, 2000 · 17 ST ANDREW ST
Check before you build
Site-specific exception 900.11.10(824)
Needs a closer look16 site-specific rules apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
On 17 St. Andrew Street, if the requirements of by-law 447-2023 are complied with, none of the provisions of By-law 569-2013 shall apply to prevent the erection or use of a mixed use building in compliance with
- Rule B
through (P) below; (B) Despite Regulation 40.5.40.10 (1) and (2), the height of the building is the distance between a Canadian Geodetic Datum elevation of 99.0 metres and the elevation of the highest point of the building or structure
- Rule C
Despite Clause 40.10.40.10(2), the permitted maximum height of a building or structure is the number in metres following the "HT" symbol as shown on Diagram 3 of by-law 447-2023
- Rule D
Despite Regulation 40.5.40.10(3) to (8), and (C) above, the following equipment and structures may project beyond the permitted maximum height shown on Diagram 3 of By-law 447-2023: (i) fences, guard rails, railings and dividers, balustrades, screens, roof drainage, chimneys, vents, lightning rods, light fixtures, architectural features, and elements of a green roof , to a maximum of 1 metres; (ii) parapets, to a maximum of 2 metres; (iii) window washing equipment, trellises, pergolas and wind screens, to a maximum height of 3 metres; and (iv) elevator overruns, elevator vestibules, stair enclosures, mechanical equipment and any associated enclosure structures to a maximum height of 5 metres
- Rule E
Despite Regulation 40.10.40.70(2), the required minimum building setbacks are as shown on Diagram 3
- Rule F
Despite (E) above, the mechanical equipment and any associated enclosure structures , stair enclosures, elevator overruns and elevator vestibules shall be setback a minimum of 7.6 metres from the front lot line
- Rule G
Despite Regulations 40.10.40.60(1) to (9), 40.10.40.70 (4), and (E) above, the following elements may encroach into the required minimum building setbacks as follows: (i) cornices, light fixtures, ornamental elements, parapets, art and landscape features, architectural features, pillars, trellises, eaves, window sills, balconies, planters, ventilation shafts, guardrails, balustrades, railings, stairs, stair enclosures, doors, wheelchair ramps, fences, landscaping , screens, awnings and canopies to a maximum of 1.5 metres; (ii) patios to a maximum of 2 metres; (iii) canopies to a maximum of 3 metres; (iv) pet amenity and relief elements to a maximum of 3.5 metres; (v) floor drainage and associated structures or elements and site servicing features, to a maximum of 5 metres; and vi. decks and terraces, to a maximum of 7.5 metres; (vi) decks and terraces, to a maximum of 7.5 metres
- Rule H
Despite Regulation 40.10.40.40(1), the total gross floor area of all buildings and structures must not exceed 3,530 square metres, comprised as follows: (i) residential uses must not exceed 3,200 square metres; and (ii) non-residential uses must not exceed 330 square metres
- Rule I
The permitted maximum number of dwelling units is 72
- Rule J
Of the total number of dwelling units to be provided: (i) a minimum of 13 dwelling units will 2 or more-bedroom units; (ii) in addition to (J)(i) above, a minimum of 8 units of the total number of dwelling units will be any combination of studios and one-bedroom dwelling units , that can be converted into any combination of larger two or three-bedroom dwelling units ; and (iii) convertible dwelling units , as described in J(ii) above, may be converted using accessible or adaptable design measures such as knock-out panels
- Rule K
A minimum of three (3) non-residential units must be provided at the ground level, which are subject to the following requirements: (i) entrances must be directly accessible from St. Andrew Street; and (ii) units must not exceed a maximum width of 9.5 metres
- Rule L
Despite Regulation 40.10.40.1(1), residential uses may be located below non-residential use portions.
- Rule M
Despite Regulation 200.5.10.1, Table 200.5.10.1 and 200.15.10(1) a minimum of 0 parking spaces may be provided and maintained on the lot
- Rule N
Despite Regulation 220.5.10.1 (1), (2) and (3), 1 loading space Type "G" shall be provided and maintained on the lot and may be shared between the residential and non-residential uses
- Rule O
Despite Regulation 230.5.10.1(5) (A), bicycle parking spaces shall be provided and maintained on the lot for the residents of, and visitors to, the building in accordance with the following: (i) a minimum of 0.9 "long-term" bicycle parking spaces for each dwelling unit ; and (ii) a minimum of 0.1 "short-term" bicycle parking spaces for each dwelling unit
- Rule P
Despite Regulations 230.5.1.10(9)(A), (10) and 230.40.1.20(1), "long-term" bicycle parking spaces may be provided in any combination of vertical, horizontal or stacked positions, may be located within a secured room or in an area on the ground floor or below grade.
Lot facts
- Area
- 1,202 m²
- Frontage
- 32.6 m
- Depth
- 39.7 m
- Street
- St Andrew St
- Corner lot
- No
- Public lane
- Ln W Spadina N Glen Baillie, 2.4 m along it
- House footprint
- Not showna new house or demolition permit since the City's 3D survey
- Max height
- 12 m
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
- Site and Area Specific Policy 197. The Official Plan has a policy for this site or area that varies the general rules. Read it before relying on zoning alone. Source
- Downtown Plan Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
- Zone CR 2.0 (c2.0; r1.5) SS2 (x824) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
Around this lot
- Minor variances approved
- 84%36 of 43 decisions
- Garden suite permits
- 1
- Laneway suite permits
- 7
- Multiplex permits
- 13
- Development applications
- 17
Within 300 m, last 10 years. 21 suite and multiplex permits: more than at 89% of Toronto houses (median 3). 43 variance decisions: more than at 78% of Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To permit the partial conversion of the ground floor garages into amenity and storage space, which will reduce the number of on-site parking spaces from 8 spaces to 3 spaces.
280 AUGUSTA AVE · May 27, 2026 · 441 m away - Minor varianceApproved
To alter the existing three-storey mixed-use building by converting the office unit (occupying the rear portion of the ground level) into one additional residential dwelling unit. The exising retail unit (occupying the front portion of the ground level), and two residential units (occupying the second and third levels) will be maintained.
281 COLLEGE ST · Feb 18, 2026 · 420 m away - Minor varianceApproved
To permit a café and art studio use (with 20 seats) within the basement level of the existing three-storey mixed-use building. The ground floor restaurant, and eight residential dwelling units (located on the second and third floors) will be maintained and unaltered.
198 AUGUSTA AVE · Nov 26, 2025 · 209 m away - Minor varianceApproved
To alter the existing two-storey mixed-use building by converting two of the existing commercial units (municipally known as 265 and 267 Augusta Avenue) into eating establishments on the ground floor with storage within the basement. The existing residential dwelling units and eating establishment (municipally known as 269 Augusta Avenue) will be maintained and unaltered. There will be a total of three eating establishments on this lot.
265 AUGUSTA AVE · Apr 30, 2025 · 279 m away - Minor varianceApproved
To convert the existing one-storey non-residential building into a two-storey mixed-use building by constructing a complete second storey addition, and a rear two-storey addition. The existing eating establishment will be maintained on the ground level. There will be one residential dwelling unit on the second level (with access from the ground level).
224 AUGUSTA AVE · Mar 5, 2025 · 252 m away
Latest activity nearby
- Minor variancePending
To permit and to maintain the conversion of two three-bedroom dwelling units into two-bedroom dwelling units by removing one bedroom from the ground floor of each unit within the existing mixed-use residential development.
115 DENISON AVE · Dec 16, 2026 · 295 m away - Consent (lot split)Pending
To obtain consent for the technical severance of the property for the purpose of re-establishing two lots which merged on title.
130 D'ARCY ST · Dec 9, 2026 · 201 m away - Building permit
2 wall signs + 1 projecting sign**CHERUBIN**
315 SPADINA AVE · Nov 25, 2026 · 129 m away - Building permit
Instalation of a BFP on the main water line after meter
58 KENSINGTON AVE · Nov 24, 2026 · 94 m away - Building permit
Proposed washroom related to permit 24 211441
204 AUGUSTA AVE · Nov 20, 2026 · 219 m away - Building permit
REV 01: REVISION TO LAYOUT as bubbledProposal for interior alterations to relocate kitchens from the Basement and 2nd Floor to the Ground Floor and 3rd Floor, and to add additional plumbing fixtures.
5 KENSINGTON AVE · Nov 13, 2026 · 122 m away - Zoning review
Application On Hold
77 GRANGE AVE · Nov 6, 2026 · 279 m away - Building permit
HVAC permit for as built heating and cooling system, relocation of existing heat pump.
160 BALDWIN ST · Nov 5, 2026 · 140 m away - Building permit
HVAC permit for as built heating and cooling system, relocation of existing heat pump.
3 NASSAU ST · Oct 19, 2026 · 185 m away - Building permit
Proposed additional dwelling unit within the basement (originally stoarge and laundry rooms).
21 OXFORD ST · Oct 19, 2026 · 282 m away
Neighbourhood: Kensington-Chinatown
About the area around the lot, not the lot itself.
- Nearest station
- St Patrick Station16 min walk
- Nearest TTC stop
- Spadina Ave at Dundas St West North Side2 min walk
- Nearest cycling route
- Wales AveSharrows, 4 min walk
- Nearest traffic count
- 472 vehicles in 8 hKensington Ave / St Andrew St, 60 m away, May 10, 2023
- Serious collisions within 500 m
- 72021–2026, killed or seriously injured: 1 fatal, 4 with pedestrians, 2 with cyclists
- Parks
- Bellevue Square Park3 min walk
- Sonya's Park4 min walk
- Glasgow Street Parkette5 min walk
Schools within 1 km
- RYERSON COMMUNITY SCHOOL & DOWNTOWN VOCAL MUSIC ACADEMY English Public 6 min walk
- BEVERLEY & SUBWAY ACADEMY TWO English Public 6 min walk
- HEYDON PARK SECONDARY SCHOOL English Public 7 min walk
- WESTSIDE MONTESSORI ELEMENTARY SCHOOL Private 7 min walk
- CORNERSTONE PREPARATORY SCHOOL - MAIN CAMPUS Private 8 min walk
- BRAEMAR COLLEGE PRIVATE SECONDARY SCHOOL Private 8 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Kensington-Chinatown | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $62,000 | $84,500 |
| Households that own their home | 32% | 54% |
| Population (2021) | 18,120 | 16,813 |
| Homes built in 1960 or before | 26% | 29% |
| Homes needing major repairs | 8% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Kensington-Chinatown | City median |
|---|---|---|
| Assault | 2017.5 | 636.3 |
| Robbery | 193 | 69.5 |
| Shootings | 21.9 | 10.5 |
| Auto theft | 118.4 | 192.6 |
| Theft over $5,000 | 219.3 | 46.1 |
| Break and enter | 443 | 172.8 |
| Theft from vehicles | 850.8 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.