Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
4 by-law investigations closed in the last two years
Good to knowClosed files (Order Issued Property Standards, Property Standards): 26 169456 PRS 00 IV (Order Issued Property Standards: Exterior yard surface and/or similar areas not maintained, 2026); 26 169453 PRS 00 IR (Property Standards, 2026); 26 103802 PRS 00 IV (Order Issued Property Standards, 2026); and 1 more.
What it means. Someone raised an issue here and the City closed the file. Ask the seller what it was about.
City of Toronto, Toronto Building orders and Municipal Licensing and Standards investigationsWork or applications in progress
Good to knowRecent records on this lot: 25 150383 STE 19 OZ (Official Plan & Zoning By-law Amendment for a 10-storey mixed-use building with a heigh..., 2025); 21 235162 STE 19 SB (Draft Plan of Subdivision for 3 Block, 2021); 21 235161 STE 19 SA (Site Plan Approval for a 6-storey mixed-use building having a non-residential gross flo..., 2021).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications3 development applications open within 300 m
Good to know3 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 10 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
23 records on file: more than at 100% of Toronto houses (median 0).
- By-law investigation26 169466 LGW 00 IVClosed
Notice Issued Long Grass
May 28, 2026 · 1684 QUEEN ST E - By-law investigation26 169456 PRS 00 IVClosed
Order Issued Property Standards: Exterior yard surface and/or similar areas not maintained.
May 28, 2026 · 1684 QUEEN ST E - By-law investigation26 169453 PRS 00 IRClosed
Property Standards
May 28, 2026 · 1684 QUEEN ST E - By-law investigation26 169452 LGW 00 IRClosed
Long Grass and Weeds
May 28, 2026 · 1684 QUEEN ST E - By-law investigation26 169450 WST 00 IVClosed
Notice Issued Waste: Fail to drain water or other liquid and cause area to be filled with clean earth or levelled so as to prevent ponding pursuant to the opinion of the Medical Off; Owner of land failed to clean and clear refuse that has been thrown, placed, dumped or deposited, including but not limited to broken wood, skids, pylons, plast
May 21, 2026 · 1684 QUEEN ST E - By-law investigation26 164635 WST 00 IRClosed
Waste
May 21, 2026 · 1684 QUEEN ST E - By-law investigation26 103802 PRS 00 IVClosed
Order Issued Property Standards
Jan 12, 2026 · 1684 QUEEN ST E - By-law investigation26 103753 PRS 00 IRClosed
Property Standards
Jan 12, 2026 · 1684 QUEEN ST E
Show 15 older records
- Zoning review25 150383 POZClosedJun 10, 2025 · 1684 QUEEN ST E
- Development application25 150383 STE 19 OZCouncil Approved
Official Plan & Zoning By-law Amendment for a 10-storey mixed-use building with a height of 34.95 metres (plus a 5.5 metre mechanical penthouse). The proposed building will include approximately 1,184 square metres of non-residential space and 14,850 square metres of residential gross floor area, including 168 rental units including three affordable rental units. The proposal also seeks to permit one level of underground parking with 54 vehicular parking spaces and 186 bicycle parking spaces. A future realignment of Penny Lane providing access on the north end of the site from the underground level to Orchard Park Boulevard and closing the eastern portion of Penny Lane is also proposed.
Apr 28, 2025 · 1698 QUEEN ST E · City file - Zoning review19 242696 PRZClosedJun 15, 2022 · 1684 QUEEN ST E
- Building permit22 147688Closed
Demolition of 2 storey wood frame building (former Day Inn motel) The south, north, and west foundation walls of the single level basement to remain at this time, and will be removed at future date in conjunction with shoring and foundation work for proposed building development
Jun 14, 2022 · 1684 QUEEN ST E - Zoning review21 235161 PSPClosedDec 10, 2021 · 1684 QUEEN ST E
- Development application21 235162 STE 19 SBUnder Review
Draft Plan of Subdivision for 3 Block.
Nov 7, 2021 · 1698 QUEEN ST E · City file - Development application21 235161 STE 19 SAUnder Review
Site Plan Approval for a 6-storey mixed-use building having a non-residential gross floor area of 1120 square metres, and a residential gross floor area of 9201 square metres. 91 residential dwelling units are proposed.
Nov 7, 2021 · 1698 QUEEN ST E · City file - Development application19 242696 STE 19 OZClosed
Zoning by-law amendment application for a proposed 6-storey mixed-use building containing 91 residential dwelling units
Oct 29, 2019 · 1684 QUEEN ST E · City file - Building permit12 260575Closed
Proposal to install 1 backflow prevention device in existing multi use building.
Nov 5, 2012 · 1684 QUEEN ST E - Building permit02 140667Closed
alter h.v.a. c. system--in connection with bldg permit #307070 (1990)
Jun 18, 2002 · 1684 QUEEN ST E - Building permit02 140677Cancelled
alter sprinkler system--in connection with bldg permit #307070 (1990)
May 30, 2002 · 1684 QUEEN ST E - Building permit98 025434Closed
MAKE INTERIOR ALTERATIONS TO PORTION OF 1ST FLOOR FOR ADDITIONAL HOTEL ROOMS. FEE $905.00
Jan 25, 1999 · 1684 QUEEN ST E - Building permit90 018217Closed
MAKE INTERIOR ALTERATIONS TO CONVERT,ALTER FRONT, EAST & WEST ELEVATIONS AND DEMOLISH MECHANICAL AREA AT ROOF SF
Jul 13, 1990 · 1684 QUEEN ST E - Zoning review82 025862 LTOClosedMar 18, 1982 · 1684 QUEEN ST E
- Zoning review81 029986 LTOClosedFeb 20, 1981 · 1684 QUEEN ST E
Check before you build
Site-specific exception 900.11.10(762)
Needs a closer look27 site-specific rules and 27 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900Holding provision (H)
Needs a closer lookDevelopment is on hold until the conditions of the holding by-law are met.
Zoning By-law 569-2013
These parts of the exception apply to this lot's address.
- Rule A
On 1684, 1698, 1700 and 1702 Queen Street East, as shown on Diagram 1 of By-law 1018-2022, if the requirements of By-law 1018-2022 are complied with, a building or structure may be constructed, used or enlarged in compliance with Regulations
- Rule B
to (AA) below; (B) For the purposes of this exception, the front lot line is the lot line abutting Queen Street East
- Rule C
Despite Regulations 40.5.40.10(1) and 40.5.40.10(2), the height of a building or structure is the distance between the Canadian Geodetic Datum of 80.56 metres and the elevation of the highest point of the building or structure
- Rule D
Regulation 40.5.40.70(1)(B) with respect to the minimum distance to the original centreline of a lane does not apply
- Rule E
Despite Regulation 40.10.40.1(1), if a lot in the CR zone has a mixed use building , all residential use portions of the building must be located above non-residential use portions of a building , other than: (i) residential lobby access; and (ii) on a corner lot , dwelling units may be located in the first storey of a building if: (a) the dwelling units are located to the rear of the non-residential uses on the first storey ; and (b) the dwelling units do not have direct access to Queen Street East
- Rule F
Despite Regulations 40.10.20.100(1)(A) and 40.10.20.100(17), the permitted maximum interior floor area for each eating establishment , retail store and retail service is 400.0 square metres
- Rule G
Despite Regulation 40.10.20.100(21)(B), the permitted maximum area of an outdoor patio is 130.0 square metres
- Rule H
Despite Regulation 40.10.40.10(2), the permitted maximum height of a building or structure is the number following the HT symbol in metres as shown on Diagram 6 of By-law 1018-2022
- Rule I
Despite Regulation 40.10.40.10(5), in the CR zone, the required minimum height of the first storey , measured between the floor of the first storey and the ceiling of the first storey , is 4.5 metres
- Rule J
Despite Regulations 40.5.40.10(3), 40.5.40.10(4), 40.5.40.10(6), 40.5.40.10(7), 40.5.40.10(8) and (H) above, the following equipment and structures may project beyond the permitted maximum height of a building : (i) equipment used for the functional operation of the building including electrical, utility, mechanical and ventilation equipment, enclosed stairwells, roof access, maintenance equipment storage, elevator shafts, chimneys, and vents may project above the height limits to a maximum of 5.0 metres within the area labelled as "Mechanical Penthouse" on Diagram 6 of By-law 1018-2022; (ii) structures that enclose, screen or cover the equipment, structures and parts of a building listed in (i) above, inclusive of a mechanical penthouse, may project above the height limits to a maximum of 5.0 metres within the area labelled as "Mechanical Penthouse" on Diagram 6 of By-law 1018-2022; (iii) an architectural structure no greater than 0.7 metres in width may project 4.0 metres above the following portions of the building within the areas labelled as a "4m tall architectural frame" on Diagram 6 of By-law 1018-2022: (a) the second and third storey along the south main wall of the building ; (b) the third storey along the west main wall of the building ; and (c) the fourth storey along the east main wall of the building ; (iv) parapets, guard rails, planters, landscaping features and elements of a green roof may project above the height limits to a maximum of 1.5 metres; (v) notwithstanding (iv) above, parapets and elements of a green roof may project 1.0 metres above the elements listed in (i) and (ii) above; (vi) window washing equipment, antennae, and lightning rods may project above the height limits to a maximum of 6.0 metres; (vii) divider and privacy screens on a balcony and/or terrace may project above the height limits to a maximum of 2.5 metres; (viii) a roof access or enclosed stairwell may project above the height limits of the area labelled as "Existing Building" on Diagram 6 of By-law 1018-2022, to a maximum of 4.0 metres; and (ix) a trellis or pergola may project above the height limits of the area labelled as "Existing Building" on Diagram 6 of By-law 1018-2022, to a maximum of 3.3 metres
- Rule K
Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area is 10,450 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 9,250 square metres; and (ii) the required minimum gross floor area for non-residential uses is 1,130 square metres, to a maximum of 1,200 square metres
- Rule L
A maximum of 90 dwelling units are permitted, of which: (i) a minimum of 64 percent must contain two bedrooms; and (ii) a minimum of 11 percent must contain three or more bedrooms
- Rule M
Despite Regulation 40.10.40.50(1), a building with 20 or more dwelling units must provide a menity space at the following rate: (i) The greater of 258.0 square metres and 2.9 square metres for each dwelling unit as indoor amenity space ; (ii) The greater of 192.0 square metres and 2.1 square metres for each dwelling unit as outdoor amenity space , of which a minimum of 192.0 square metres must be in a location adjoining or directly accessible to the indoor amenity space ; and (iii) none of the outdoor component may be a green roof
- Rule N
Despite Regulation 40.10.40.70(2), the required minimum building setbacks for the second through sixth storeys are as shown in metres on Diagram 6 of By-law 1018-2022
- Rule O
Despite Regulation 40.10.40.70(2), the required minimum building setbacks for the first storey are as shown in metres on Diagram 7 of By-law 1018-2022
- Rule P
Despite Clause 40.10.40.60 and (N) and (O) above, the following elements may encroach into the required minimum building setbacks and separation distances as follows: (i) Balconies, to a maximum of 2.5 metres, from: (a) the south main wall at the fourth and fifth storeys , as shown on Diagram 6 of By-law 1018-2022; and (b) the east main wall at the sixth storey , as shown on Diagram 6 of By-law 1018-2022; (ii) canopies and awnings at the ground floor, to a maximum extent of 1.5 metres, if no part of the canopy, awning or similar structure is located more than 4.0 metres above the elevation of the ground directly below it; (iii) architectural features, such as a pilaster, decorative column, cornice, sill, belt course, or chimney breast, to a maximum of 0.7 metres, if they are no closer to a lot line than 0.3 metres; (iv) eaves, to a maximum extent of 0.6 metres, if they are no closer to a lot line than 0.3 metres; (v) air conditioners, antennae, vents, ducts and pipes within the building setbacks from the area identified as the "Existing Building" on Diagram 6 of By-law 1018-2022, to a maximum of 0.8 metres, if they are no closer to a lot line than 0.3 metres
- Rule Q
Despite Regulation 200.5.10.1(1) and Table 200.5.10.1, parking spaces must be provided in accordance with the following: (i) a minimum of 0.6 residential occupant parking spaces for each dwelling unit ; and (ii) a minimum of 0.06 residential visitor parking spaces for each dwelling unit
- Rule R
Despite Regulation 200.5.1.10(2)(E), equipment for the charging of one electric vehicle is permitted within a parking space , subject to the equipment being located in the same parking space as the vehicle to be charged and: (i) being within 0.25 metres of two adjoining sides of the parking space which are not adjacent and parallel to a drive aisle from which vehicle access is provided, measured at right angles; or (ii) being at least 5.20 metres from a drive aisle from which vehicle access is provided, measured at right angles, and at least 1.0 metre from the ground
- Rule S
A parking space required by this By-law for a use in the Commercial Residential Zone category must be available for the use for which it is required
- Rule T
A parking space must be on the same lot as the use for which the parking space is required
- Rule U
A surface parking space may not be located in the front yard
- Rule V
Despite Regulation 200.15.1(1), an accessible parking space must have the following minimum dimensions: (i) length of 5.6 metres; (ii) width of 3.4 metres; and (iii) vertical clearance of 2.1 metres
- Rule W
The entire length of an accessible parking space must be adjacent to a 1.5 metre wide accessible barrier-free aisle or path as shown on Diagram 1 and Diagram 2 of By-law 579-2017
- Rule X
Despite Regulation 200.15.1(4), an accessible parking space may be located within 15 metres of an entrance to the building or an elevator with access to the ground level
- Rule Y
Despite Regulations 220.5.10.1(2) and 220.5.10.1(3), one 1 Type "G" loading space must be provided for the residential uses and may be shared with non-residential uses
- Rule Z
Despite Regulations 230.5.1.10(4) and 230.5.1.10(10), bicycle parking space must be provided and maintained in accordance with the following: (i) both "long-term" and "short-term" bicycle parking spaces may be provided in a stacked bicycle parking space ; (ii) the minimum dimension of a bicycle parking space is: (a) minimum length of 1.8 metres; (b) minimum width of 0.6 metres; and (c) minimum vertical clearance from the ground of 1.9 metres; (iii) the minimum dimension of a bicycle parking space if placed in a vertical position on a wall, structure or mechanical device is: (a) minimum length or vertical clearance of 1.9 metres; (b) minimum width of 0.6 metres; and (c) minimum horizontal clearance from the wall of 1.2 metres; (iv) the minimum dimension of a stacked bicycle parking space is: (a) minimum length of 1.9 metres; (b) minimum vertical clearance of 1.2 metres; and (c) minimum width of 0.45 metres
- Rule AA
Despite regulation 230.40.1.20(1)(C), a bicycle parking space for a dwelling unit may be located in a stacked bicycle parking space in a secured room, enclosure or bicycle locker. Prevailing By-laws and Prevailing Sections: (None Apply)
- Older by-law A
On 1684, 1698, 1700 and 1702 Queen Street East, as shown on Diagram 1 of By-law 1018-2022, if the requirements of By-law 1018-2022 are complied with, a building or structure may be constructed, used or enlarged in compliance with Regulations
- Older by-law B
to (AA) below; (B) For the purposes of this exception, the front lot line is the lot line abutting Queen Street East
- Older by-law C
Despite Regulations 40.5.40.10(1) and 40.5.40.10(2), the height of a building or structure is the distance between the Canadian Geodetic Datum of 80.56 metres and the elevation of the highest point of the building or structure
- Older by-law D
Regulation 40.5.40.70(1)(B) with respect to the minimum distance to the original centreline of a lane does not apply
- Older by-law E
Despite Regulation 40.10.40.1(1), if a lot in the CR zone has a mixed use building , all residential use portions of the building must be located above non-residential use portions of a building , other than: (i) residential lobby access; and (ii) on a corner lot , dwelling units may be located in the first storey of a building if: (a) the dwelling units are located to the rear of the non-residential uses on the first storey ; and (b) the dwelling units do not have direct access to Queen Street East
- Older by-law F
Despite Regulations 40.10.20.100(1)(A) and 40.10.20.100(17), the permitted maximum interior floor area for each eating establishment , retail store and retail service is 400.0 square metres
- Older by-law G
Despite Regulation 40.10.20.100(21)(B), the permitted maximum area of an outdoor patio is 130.0 square metres
- Older by-law H
Despite Regulation 40.10.40.10(2), the permitted maximum height of a building or structure is the number following the HT symbol in metres as shown on Diagram 6 of By-law 1018-2022
- Older by-law I
Despite Regulation 40.10.40.10(5), in the CR zone, the required minimum height of the first storey , measured between the floor of the first storey and the ceiling of the first storey , is 4.5 metres
- Older by-law J
Despite Regulations 40.5.40.10(3), 40.5.40.10(4), 40.5.40.10(6), 40.5.40.10(7), 40.5.40.10(8) and (H) above, the following equipment and structures may project beyond the permitted maximum height of a building : (i) equipment used for the functional operation of the building including electrical, utility, mechanical and ventilation equipment, enclosed stairwells, roof access, maintenance equipment storage, elevator shafts, chimneys, and vents may project above the height limits to a maximum of 5.0 metres within the area labelled as "Mechanical Penthouse" on Diagram 6 of By-law 1018-2022; (ii) structures that enclose, screen or cover the equipment, structures and parts of a building listed in (i) above, inclusive of a mechanical penthouse, may project above the height limits to a maximum of 5.0 metres within the area labelled as "Mechanical Penthouse" on Diagram 6 of By-law 1018-2022; (iii) an architectural structure no greater than 0.7 metres in width may project 4.0 metres above the following portions of the building within the areas labelled as a "4m tall architectural frame" on Diagram 6 of By-law 1018-2022: (a) the second and third storey along the south main wall of the building ; (b) the third storey along the west main wall of the building ; and (c) the fourth storey along the east main wall of the building ; (iv) parapets, guard rails, planters, landscaping features and elements of a green roof may project above the height limits to a maximum of 1.5 metres; (v) notwithstanding (iv) above, parapets and elements of a green roof may project 1.0 metres above the elements listed in (i) and (ii) above; (vi) window washing equipment, antennae, and lightning rods may project above the height limits to a maximum of 6.0 metres; (vii) divider and privacy screens on a balcony and/or terrace may project above the height limits to a maximum of 2.5 metres; (viii) a roof access or enclosed stairwell may project above the height limits of the area labelled as "Existing Building" on Diagram 6 of By-law 1018-2022, to a maximum of 4.0 metres; and (ix) a trellis or pergola may project above the height limits of the area labelled as "Existing Building" on Diagram 6 of By-law 1018-2022, to a maximum of 3.3 metres
- Older by-law K
Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area is 10,450 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 9,250 square metres; and (ii) the required minimum gross floor area for non-residential uses is 1,130 square metres, to a maximum of 1,200 square metres
- Older by-law L
A maximum of 90 dwelling units are permitted, of which: (i) a minimum of 64 percent must contain two bedrooms; and (ii) a minimum of 11 percent must contain three or more bedrooms
- Older by-law M
Despite Regulation 40.10.40.50(1), a building with 20 or more dwelling units must provide a menity space at the following rate: (i) The greater of 258.0 square metres and 2.9 square metres for each dwelling unit as indoor amenity space ; (ii) The greater of 192.0 square metres and 2.1 square metres for each dwelling unit as outdoor amenity space , of which a minimum of 192.0 square metres must be in a location adjoining or directly accessible to the indoor amenity space ; and (iii) none of the outdoor component may be a green roof
- Older by-law N
Despite Regulation 40.10.40.70(2), the required minimum building setbacks for the second through sixth storeys are as shown in metres on Diagram 6 of By-law 1018-2022
- Older by-law O
Despite Regulation 40.10.40.70(2), the required minimum building setbacks for the first storey are as shown in metres on Diagram 7 of By-law 1018-2022
- Older by-law P
Despite Clause 40.10.40.60 and (N) and (O) above, the following elements may encroach into the required minimum building setbacks and separation distances as follows: (i) Balconies, to a maximum of 2.5 metres, from: (a) the south main wall at the fourth and fifth storeys , as shown on Diagram 6 of By-law 1018-2022; and (b) the east main wall at the sixth storey , as shown on Diagram 6 of By-law 1018-2022; (ii) canopies and awnings at the ground floor, to a maximum extent of 1.5 metres, if no part of the canopy, awning or similar structure is located more than 4.0 metres above the elevation of the ground directly below it; (iii) architectural features, such as a pilaster, decorative column, cornice, sill, belt course, or chimney breast, to a maximum of 0.7 metres, if they are no closer to a lot line than 0.3 metres; (iv) eaves, to a maximum extent of 0.6 metres, if they are no closer to a lot line than 0.3 metres; (v) air conditioners, antennae, vents, ducts and pipes within the building setbacks from the area identified as the "Existing Building" on Diagram 6 of By-law 1018-2022, to a maximum of 0.8 metres, if they are no closer to a lot line than 0.3 metres
- Older by-law Q
Despite Regulation 200.5.10.1(1) and Table 200.5.10.1, parking spaces must be provided in accordance with the following: (i) a minimum of 0.6 residential occupant parking spaces for each dwelling unit ; and (ii) a minimum of 0.06 residential visitor parking spaces for each dwelling unit
- Older by-law R
Despite Regulation 200.5.1.10(2)(E), equipment for the charging of one electric vehicle is permitted within a parking space , subject to the equipment being located in the same parking space as the vehicle to be charged and: (i) being within 0.25 metres of two adjoining sides of the parking space which are not adjacent and parallel to a drive aisle from which vehicle access is provided, measured at right angles; or (ii) being at least 5.20 metres from a drive aisle from which vehicle access is provided, measured at right angles, and at least 1.0 metre from the ground
- Older by-law S
A parking space required by this By-law for a use in the Commercial Residential Zone category must be available for the use for which it is required
- Older by-law T
A parking space must be on the same lot as the use for which the parking space is required
- Older by-law U
A surface parking space may not be located in the front yard
- Older by-law V
Despite Regulation 200.15.1(1), an accessible parking space must have the following minimum dimensions: (i) length of 5.6 metres; (ii) width of 3.4 metres; and (iii) vertical clearance of 2.1 metres
- Older by-law W
The entire length of an accessible parking space must be adjacent to a 1.5 metre wide accessible barrier-free aisle or path as shown on Diagram 1 and Diagram 2 of By-law 579-2017
- Older by-law X
Despite Regulation 200.15.1(4), an accessible parking space may be located within 15 metres of an entrance to the building or an elevator with access to the ground level
- Older by-law Y
Despite Regulations 220.5.10.1(2) and 220.5.10.1(3), one 1 Type "G" loading space must be provided for the residential uses and may be shared with non-residential uses
- Older by-law Z
Despite Regulations 230.5.1.10(4) and 230.5.1.10(10), bicycle parking space must be provided and maintained in accordance with the following: (i) both "long-term" and "short-term" bicycle parking spaces may be provided in a stacked bicycle parking space ; (ii) the minimum dimension of a bicycle parking space is: (a) minimum length of 1.8 metres; (b) minimum width of 0.6 metres; and (c) minimum vertical clearance from the ground of 1.9 metres; (iii) the minimum dimension of a bicycle parking space if placed in a vertical position on a wall, structure or mechanical device is: (a) minimum length or vertical clearance of 1.9 metres; (b) minimum width of 0.6 metres; and (c) minimum horizontal clearance from the wall of 1.2 metres; (iv) the minimum dimension of a stacked bicycle parking space is: (a) minimum length of 1.9 metres; (b) minimum vertical clearance of 1.2 metres; and (c) minimum width of 0.45 metres
- Older by-law AA
Despite regulation 230.40.1.20(1)(C), a bicycle parking space for a dwelling unit may be located in a stacked bicycle parking space in a secured room, enclosure or bicycle locker. Prevailing By-laws and Prevailing Sections: (None Apply)
Lot facts
- Area
- 1,893 m²
- Frontage
- 38.9 mestimated, irregular lot
- Depth
- 59.4 mestimated, irregular lot
- Street
- Queen St E
- Corner lot
- Yes, also on Orchard Park Blvd59.4 m along it
- Public lane
- Ln 1 N Queen W Penny Lane, 7.6 m along it
- House footprint
- 950 m²roof up to 16.2 m
- Back yard
- 2.4 mhouse to rear lot line
- Side yards
- 0.1 m and 12 mhouse to side lot lines; 0 is a shared wall
- Buildings on the lot
- 1house, garage, sheds
- Max height
- 12 m
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
Around this lot
- Minor variances approved
- 100%13 of 13 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 1
- Development applications
- 8
Within 300 m, last 10 years. 1 suite and multiplex permits: no more than at most Toronto houses (median 3). 13 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To alter the redevelopment standards (as approved under Site Specific Zoning By-laws 831-2020 and 832-2020) for a 16 and 17-storey mixed-use building, (which is currently under construction), by increasing the maximum interior floor area for a retail store (at-grade grocery store) as well as the vertical projections for solar equipment on the roof, and to reduce the minimum height of the first storey, the soft landscaping along the west lot line, and the minimum above ground separation distances.
1555 QUEEN ST E · Nov 27, 2024 · 474 m away - Minor varianceApproved
To facilitate the redevelopment of this site for 16 and 17-storey mixed-use buildings. The below-grade portion of this development is currently under construction. This application is necessitated to amend Section 11 (timing of municipal improvements) under Site Specific By-law 831-2020 (Appendix A) and Site Specific By-law 832-2020 (Schedule A).
1555 QUEEN ST E · Jan 18, 2023 · 474 m away - Minor varianceApproved
To alter the redevelopment plan for a 10-storey affordable rental building, approved under Site Specific Zoning By-law 831-2020 and 832-2020.
1555 QUEEN ST E · Nov 23, 2022 · 474 m away
Latest activity nearby
- Zoning review
Notice Sent
35 COXWELL AVE · Nov 6, 2026 · 285 m away - Zoning review
Notice Sent
35 COXWELL AVE · Nov 6, 2026 · 285 m away - Zoning review
Notice Sent
35 COXWELL AVE · Nov 6, 2026 · 285 m away - Zoning review
Not Started
35 COXWELL AVE · Nov 6, 2026 · 285 m away - Zoning review
Not Started
35 COXWELL AVE · Nov 6, 2026 · 285 m away - Zoning review
Notice Sent
35 COXWELL AVE · Nov 6, 2026 · 285 m away - Zoning review
Not Started
35 COXWELL AVE · Nov 6, 2026 · 285 m away - Zoning review
Not Started
35 COXWELL AVE · Nov 6, 2026 · 285 m away - Zoning review
Cancelled
35 COXWELL AVE · Nov 5, 2026 · 285 m away - Zoning review
Cancelled
35 COXWELL AVE · Nov 5, 2026 · 285 m away
Neighbourhood: Woodbine Corridor
About the area around the lot, not the lot itself.
- Nearest station
- Coxwell Station33 min walk
- Nearest TTC stop
- Queen St East at Kingston Rd1 min walk
- Nearest cycling route
- Woodbine Park TrlMulti-Use Trail, 2 min walk
- Nearest traffic count
- 13,431 vehicles in 14 hKingston Rd / Queen St E / Eastern Ave, 60 m away, Oct 20, 2024
- Serious collisions within 500 m
- 12021–2026, killed or seriously injured: 0 fatal, 1 with pedestrians, 0 with cyclists
- Parks
- Woodbine Park1 min walk
- Orchard Park1 min walk
- Measurement Park2 min walk
Schools within 1 km
- ACADEMY OF THOUGHT AND INDUSTRY TORONTO Private 5 min walk
- DUKE OF CONNAUGHT JR & SR PUBLIC SCHOOL English Public 12 min walk
- KEW PARK MONTESSORI SCHOOL - HIAWATHA Private 13 min walk
- KEW BEACH JR PUBLIC SCHOOL English Public 14 min walk
- BOWMORE ROAD JR & SR PUBLIC SCHOOL English Public 16 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Woodbine Corridor | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $97,000 | $84,500 |
| Households that own their home | 60% | 54% |
| Population (2021) | 12,205 | 16,813 |
| Homes built in 1960 or before | 66% | 29% |
| Homes needing major repairs | 8% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Woodbine Corridor | City median |
|---|---|---|
| Assault | 728.8 | 636.3 |
| Robbery | 21.9 | 69.5 |
| Auto theft | 65.6 | 192.6 |
| Theft over $5,000 | 43.7 | 46.1 |
| Break and enter | 123.9 | 172.8 |
| Theft from vehicles | 131.2 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.