Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
TRCA regulated area (48% of lot)
Needs a closer lookPart of the lot is near a valley, floodplain, shoreline or wetland. Work there needs a TRCA permit and may be restricted.
What it means. Additions, pools and new buildings in the regulated part need a TRCA permit and may be refused. Ask your insurer about flood coverage.
How to confirm. A TRCA property inquiry letter says which policies apply ($385, at least two weeks). Details
Ontario Regulation 41/24, TRCA Regulation LimitRavine and natural feature protection (37% of lot)
Needs a closer lookPart of the lot is in the area covered by the City's Ravine and Natural Feature Protection By-law. The City's map of the area was last published in 2019.
What it means. In that part, injuring or removing a tree of any size, grading, filling or dumping needs a City permit. Plans for a pool, addition or garden suite there may be refused.
How to confirm. Urban Forestry confirms where the protected area runs and whether work needs a permit. Details
Toronto Municipal Code, Chapter 658Building permit open since 2015
Needs a closer lookStill open in the City's records: 15 134141 (install one backflow preventer, 2015, status Inspection).
What it means. An open permit can mean work that was never finished or never passed final inspection. After closing, finishing it or closing the file can fall to you.
How to confirm. Ask the seller for the final inspection records. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016)Natural Heritage System (36% of lot)
Good to knowPart of the lot is in the Natural Heritage System shown on Official Plan Map 9.
What it means. New buildings or additions in that part need a natural heritage impact study.
How to confirm. City Planning confirms the policies that apply. Details
City of Toronto Official Plan, Map 93 by-law investigations closed in the last two years
Good to knowClosed files (Adequate Heat, Order Issued Property Standards, Property Standards): 26 248422 HEA 00 IR (Adequate Heat, 2026); 25 243708 PRS 00 IV (Order Issued Property Standards: Height of the guard for the exit stairs are less than..., 2025); 25 243707 PRS 00 IR (Property Standards, 2025).
What it means. Someone raised an issue here and the City closed the file. Ask the seller what it was about.
City of Toronto, Toronto Building orders and Municipal Licensing and Standards investigationsWork or applications in progress
Good to knowRecent records on this lot: 19 211934 STE 12 OZ (April 2024 Resubmission: Official Plan and Zoning By-law Amendment application to permi..., 2019); 19 211943 STE 12 SA (Site Plan Approval Application to facilitate the construction of an 8-storey rental apa..., 2019).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications2 development applications open within 300 m
Good to know2 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 8 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development ApplicationsRental building evaluation: 84 out of 100
Good to knowThe City's RentSafeTO program evaluated this rental building in 2025 (6 storeys, 73 units, built 1954).
What it means. The score covers common areas, building systems and records. Read the evaluation details for the items that scored low.
How to confirm. The City's RentSafeTO page has the evaluation results and any open orders for the building. Details
City of Toronto, RentSafeTO Apartment Building Evaluations
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
13 records on file: more than at 100% of Toronto houses (median 0).
- By-law investigation26 248422 HEA 00 IRClosed
Adequate Heat
Oct 2, 2026 · 1603 BATHURST ST - Building permit26 113439Cancelled
Proposal for stairwell railing replacement.
Feb 5, 2026 · 1603 BATHURST ST - By-law investigation25 243708 PRS 00 IVClosed
Order Issued Property Standards: Height of the guard for the exit stairs are less than 1,070 millimetres around landings.; Height of the guard for the exit stairs are less than 920 millimetres measured vertically to the top of the guard from a line drawn through the outside edges of; Required guard does not prevent the passage of a sphere having a diameter more than 100 millimetres.; Required handrails on stairs or ramps are less than 865mm or more than 965mm high; The guard is designed that a member, attachment or opening located between 140 millimetres and 900 millimetres above the level being protected facilitates climb
Oct 22, 2025 · 1603 BATHURST ST - By-law investigation25 243707 PRS 00 IRClosed
Property Standards
Oct 22, 2025 · 1603 BATHURST ST - Development application19 211934 STE 12 OZOMB Approved
April 2024 Resubmission: Official Plan and Zoning By-law Amendment application to permit a 7-storey residential building with 74 residential units including 9 rental replacement units
Aug 26, 2019 · 1603 BATHURST ST · City file - Development application19 211943 STE 12 SAAppeal Received
Site Plan Approval Application to facilitate the construction of an 8-storey rental apartment building containing 79 new residential units. 1601 Bathurst consists of an existing 4-storey apartment building to be demolished.
Aug 26, 2019 · 1603 BATHURST ST · City file - Zoning review18 155055 LPRClosedMay 8, 2018 · 1603 BATHURST ST
- Building permit15 143850Closed
Porposal for underground parking garage repairs in existing apartment building.
May 14, 2015 · 1603 BATHURST ST
Show 5 older records
- Building permit15 134141Inspection
install one backflow preventer
Apr 22, 2015 · 1603 BATHURST ST - Zoning review12 117904 LPRClosedFeb 6, 2012 · 1603 BATHURST ST
- Zoning review09 115608 LPRCancelledMar 10, 2009 · 1603 BATHURST ST
- Zoning review06 123851 LTOClosedApr 6, 2006 · 1603 BATHURST ST
- Building permit02 136724Closed
replacement of 75 balcony railings and concrete repair to balcony slab
Jun 26, 2002 · 1603 BATHURST ST
Check before you build
Site-specific exception 900.2.10(546)
Needs a closer look2 site-specific rules apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
On the lands, the replacement of any building existing as of February 28, 1977 having a height exceeding the height prescribed by this By-law is permitted, if the height of the new building does not exceed the height of the building being replaced; [TO: 438-86; 12 (1) 320]
- Rule B
On the lands, an office of a physician or dentist is permitted, subject to the conditions that: (i) it is located in the basement or on the first floor of a detached dwelling that such physician or dentist uses as their private residence; and (ii) the principal entrance is from Bathurst St. [TO: 438-86; 12(2) 274]
Lot facts
- Area
- 7,328 m²
- Frontage
- 86.4 mestimated, irregular lot
- Depth
- 197.2 mestimated, irregular lot
- Street
- Heathdale Rd
- Corner lot
- Yes, also on Bathurst St197.2 m along it
- Public lane
- None
- House footprint
- 1,369 m²roof up to 25.1 m
- Back yard
- 40.2 mhouse to rear lot line
- Side yards
- 9.8 m and 38.4 mhouse to side lot lines
- Buildings on the lot
- 4house, garage, sheds
- Max height
- 11 m
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
Around this lot
- Minor variances approved
- 93%27 of 29 decisions
- Garden suite permits
- 1
- Laneway suite permits
- 0
- Multiplex permits
- 4
- Development applications
- 4
Within 300 m, last 10 years. 5 suite and multiplex permits: more than at 59% of Toronto houses (median 3). 29 variance decisions: more than at 62% of Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To alter the existing two-storey detached dwelling by constructing a rear two-storey addition with a rear second storey juliet balcony, a rear basement extension at the northwest corner of the dwelling, and a new rear ground floor deck and stairs.
140 KENWOOD AVE · Aug 19, 2026 · 434 m away - Minor varianceApproved
To construct a new two-storey detached U-shaped dwelling with an integral four-car garage at the basement level, a horseshoe driveway, a front basement foyer (terrace on ground floor above foyer), a rear ground floor one-storey conservatory (connected internally with main ground level) with stairs, a rear courtyard (between dwelling and conservatory structure), a rear second floor balcony and an in-ground swimming pool in the rear yard. Also, to construct two new one-storey detached ancillary buildings (cabanas) on the east and west sides of the in-ground swimming pool.
4 RIDGEWOOD RD · Jan 14, 2026 · 293 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 1050-2022), for a new 30-storey mixed-use building, by increasing building height, non-residential and residential gross floor areas, and decreasing outdoor amenity space, Site Plan Control Application File 20 21 213475 STE 12 SA, which is currently under review. There will be a total of 305 residential dwelling units on this lot.
91 RAGLAN AVE · Jul 9, 2025 · 387 m away - Minor varianceApproved
To construct a new three-storey detached dwelling with a covered front porch, an integral garage with a widened driveway, a rear basement walkout, and a rear first level deck. There will be one secondary suite within the basement.
35 VESTA DR · Jun 18, 2025 · 465 m away - Minor varianceApproved
To construct a new three-storey detached dwelling (duplex) with an integral garage, a front covered porch with stairs, a rear basement walkout with terrace, a rear ground floor terrace, a rear second storey balcony, a rear third storey juliet balcony, and a rear in-ground swimming pool. There will be a total of two residential dwelling units on this lot (one unit in the basement, and one unit occupying the first, second and third levels).
37 HEATHDALE RD · Jun 18, 2025 · 372 m away
Latest activity nearby
- Building permit
Proposed installation of rooftop safety gaurd rail.
4 GLENAYR RD · Nov 16, 2026 · 149 m away - Building permit
PROPOSED DEMOLITION OF AN EXISTING HOUSE AND CONSTRUCTION OF A NEW DUPLEX DWELLING WITH AN ATTACHED GARAGE.
617 LONSDALE RD · Nov 4, 2026 · 233 m away - Building permit
PROPOSED DEMOLITION OF AN EXITING HOUSE AND CONSTRUCTION OF A NEW DUPLEX DWELLING WITH AN ATTACHED GARAGE.
617 LONSDALE RD · Nov 4, 2026 · 233 m away - Zoning review
Notice Sent
229 LONSMOUNT DR · Oct 16, 2026 · 95 m away - Building permit
Proposal for replacement of pit hatches and ladder in train way pump room 3S128 at TTC's Glenayr Emergency Exit Building (ESB).
4 GLENAYR RD · Oct 15, 2026 · 149 m away - Building permit
Rev-02 : Removal of two W12 windows on the third floor, removal of the fire shutter on A2.04 (skylights have been omitted from the calculations per discussions with the inspector)Rev 01 - sink added to garage and bathroom added to third floor.Proposal for interior alterations, 2nd and 3rd floor addition, new roof for entire dwelling and new covered patio.
27 GLENAYR RD · Sep 1, 2026 · 237 m away - Zoning review
Closed
182 MONTCLAIR AVE · Aug 27, 2026 · 283 m away - Zoning review
Closed
42 GLENAYR RD · Jun 15, 2026 · 290 m away - Building permit
Installation of Main Drain Pipe Backwater Valve.
201 LONSMOUNT DR · Jun 1, 2026 · 287 m away - Building permit
Installation of Main Drain Pipe Backwater Valve.
201 LONSMOUNT DR · May 6, 2026 · 287 m away
Neighbourhood: Forest Hill South
About the area around the lot, not the lot itself.
- Nearest station
- St Clair West Station9 min walk
- Nearest TTC stop
- Bathurst St at Lonsdale Rd4 min walk
- Nearest cycling route
- Cedarvale Ravine TrlMulti-Use Trail, 1 min walk
- Nearest traffic count
- 30,717 vehicles in 14 hBathurst St / Heathdale Rd, 90 m away, Jun 4, 2025
- Serious collisions within 500 m
- 22021–2026, killed or seriously injured: 1 fatal, 2 with pedestrians, 0 with cyclists
- Parks
- Cedarvale Ravine1 min walk
- Cedarvale Park2 min walk
- Ridgewood Parkette5 min walk
Schools within 1 km
- ST MICHAEL'S COLLEGE SCHOOL Private 8 min walk
- FOREST HILL TUTORING Private 9 min walk
- HOLY ROSARY CATHOLIC ELEMENTARY SCHOOL English Separate 11 min walk
- HUMEWOOD COMMUNITY SCHOOL English Public 12 min walk
- ROBBINS HEBREW ACADEMY Private 13 min walk
- FOREST HILL JR & SR PUBLIC SCHOOL English Public 13 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Forest Hill South | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $109,000 | $84,500 |
| Households that own their home | 49% | 54% |
| Population (2021) | 10,860 | 16,813 |
| Homes built in 1960 or before | 45% | 29% |
| Homes needing major repairs | 7% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Forest Hill South | City median |
|---|---|---|
| Assault | 196.5 | 636.3 |
| Robbery | 73.7 | 69.5 |
| Auto theft | 106.4 | 192.6 |
| Theft over $5,000 | 73.7 | 46.1 |
| Break and enter | 327.4 | 172.8 |
| Theft from vehicles | 131 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.