Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
Heritage property: designated (Part IV)
Needs a closer lookOn the City's Heritage Register. Demolition and exterior changes need heritage review.
What it means. Renovations, additions and demolition can take longer, cost more or be refused.
How to confirm. Heritage Planning at the City confirms the status and what it covers. Details
City of Toronto Heritage RegisterBuilding permit open since 2011
Needs a closer lookStill open in the City's records: 11 317374 (Proposal to upgrade the fire alarm system in an existing office building. Convenience a..., 2011, status Inspection).
What it means. An open permit can mean work that was never finished or never passed final inspection. After closing, finishing it or closing the file can fall to you.
How to confirm. Ask the seller for the final inspection records. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016)2 by-law investigations closed in the last two years
Good to knowClosed files (Notice Issued Prop Standards, Property Standards): 25 243249 PRS 00 IV (Notice Issued Prop Standards, 2025); 25 225004 PRS 00 IR (Property Standards, 2025).
What it means. Someone raised an issue here and the City closed the file. Ask the seller what it was about.
City of Toronto, Toronto Building orders and Municipal Licensing and Standards investigationsWork or applications in progress
Good to knowRecent records on this lot: 19 186554 STE 10 SA (Site Plan Approval application for a 57-storey mixed-use building containing 482 reside..., 2019).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications24 development applications open within 300 m
Good to know24 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 80 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
19 records on file: more than at 100% of Toronto houses (median 0).
- By-law investigation25 243286 WST 00 IVClosed
Notice Issued Waste: Owner of land failed to clean and clear refuse that has been thrown, placed, dumped or deposited, including but not limited to
Oct 22, 2025 · 158 PEARL ST - By-law investigation25 243261 WST 00 IRClosed
Waste
Oct 22, 2025 · 158 PEARL ST - By-law investigation25 243249 PRS 00 IVClosed
Notice Issued Prop Standards
Sep 12, 2025 · 158 PEARL ST - By-law investigation25 225004 PRS 00 IRClosed
Property Standards
Sep 12, 2025 · 158 PEARL ST - Development application19 186554 STE 10 SANOAC Issued
Site Plan Approval application for a 57-storey mixed-use building containing 482 residential units and 3,975.3 sq. m of non-residential gross floor area, and 114 parking spaces in 4 levels of underground parking. The existing heritage buildings are being conserved and incorporated into the building podium.
Jul 10, 2019 · 150 PEARL ST · City file - Building permit18 200114Closed
Proposal for interior alterations to existing exit stair and lobby on ground floor.
Aug 2, 2018 · 158 PEARL ST - Development application16 269407 STE 20 OZClosed
Revised proposal for rezoning to allow a 58 storey mixed-use building containing 480 residential units (reduced from 610 units in initial proposal) and 3,915.9 sq. m of non-residential GFA, with 4 levels of underground parking. This application is the subject of an appeal to the LPAT (Case No. PL170831), on the basis of municipal non-decision.
Dec 21, 2016 · 150 PEARL ST · City file - Building permit15 191823Cancelled
Proposal for interior alterations to second floor office space, "RNAO"
Aug 5, 2015 · 158 PEARL ST
Show 11 older records
- Building permit15 171707Closed
Install one new Electromagnetic Locks
Jul 3, 2015 · 154 PEARL ST - Building permit11 317374Inspection
Proposal to upgrade the fire alarm system in an existing office building. Convenience address 154-158 Pearl St.
Dec 23, 2011 · 156 PEARL ST - Building permit10 263635Closed
Proposal to install one back flow prevention device. Building comprised of Office units. Convenience address 154 Pearl Street.
Oct 15, 2010 · 156 PEARL ST - Building permit10 229061Cancelled
Proposal to install one back flow prevention device to office building.
Jul 27, 2010 · 154 PEARL ST - Building permit09 121016Cancelled
Proposal to construct addition to front of building for new entrance to existing office building "Registered Nurses Association of Ontario" (2.32m2).
Mar 27, 2009 · 156 PEARL ST - Building permit07 257330Closed - Dormant
For the removal of 3 non-loadbearing partitions only. Convenience address 154-158 Pearl St.
Sep 10, 2007 · 156 PEARL ST - Building permit05 167688Closed
Revision to barrier-free elevator shaft plus alteration to washrooms at basement and ground floor.Interior alterations to convert ground floor & lower level to commercial (office)
Dec 19, 2005 · 156 PEARL ST - Building permit01 118698Closed
Removal of interior non-loadbearing partitions only to basement and ground floor. All lifesafety systems to remain in place and functional. No renovations or other interior alterations.
Mar 19, 2001 · 156 PEARL ST - Building permit00 121957Cancelled
make interior alterations to portion of ground floor existing office. also make structural alterations to 2nd and 3rd floor existing office. Tenant: Gee, Jeffery and Partners.
Jan 18, 2000 · 156 PEARL ST - Building permit99 012096Closed
156 PEARL ST: INSTALL NEW DOOR OPENING AND STAIR AT 3RD FLOOR LEVEL TO CONNECT TO 166 PEARL ST. 166 PEARL ST: MAKE INTERIOR ALTERATIONS ADD NEW DOOR OPENING AT 3RD FLOOR LEVEL TO CONNECT TO 156 PEARL ST. AND INSTALL 2 MAGLOCKS
Mar 9, 1999 · 156 PEARL ST - Building permit96 023044Closed
MAKE INTERIOR ALTERATIONS TO 2ND AND 3RD FLOORS FOR DESIGNER STUDIO SS
Nov 25, 1996 · 154 PEARL ST
Check before you build
Site-specific exception 900.12.10(28)
Needs a closer look16 site-specific rules apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
On 15 Duncan Street and 150 to 158 Pearl Street, if the requirements of By-law 1192-2022(OLT), including Section 6 and Schedule A are complied with, a building or structure may be constructed, used or enlarged in compliance with regulations
- Rule B
to (P) below. (B) The total gross floor area of all buildings and structures must not exceed 42,550 square metres of which a minimum non-residential gross floor area of 3,915 square metres is required
- Rule C
A minimum of ten percent of the total number of dwelling units must have three or more bedrooms
- Rule D
Despite Clauses 50.10.40.70, 50.10.40.71 and 50.10.40.80, and Article 600.10.10, the minimum required building setbacks and minimum above-ground distance between main walls are shown in metres on Diagram 3, Diagram 4, Diagram 5, Diagram 6, Diagram 7, Diagram 8, and Diagram 9 of By-law 1192-2022(OLT)
- Rule E
Regulation 50.10.40.1(1) with respect to the first floor elevation does not apply
- Rule F
Regulations 50.10.40.1(2) and (4) with respect to building orientation to a street do not apply
- Rule G
Despite Clause 50.10.40.60 and (D) above, the following building elements and structures are permitted to encroach into required building setbacks shown on Diagram 3, Diagram 4, Diagram 5, Diagram 6, Diagram 7, Diagram 8, and Diagram 9 of By-law 1192-2022(OLT): (i) Public art, landscape features, wheel chair ramps, light fixtures, stairs and stair enclosures, guardrails, bollards, awnings, canopies, railings, fences, vents, shafts, stacks, chimneys, roof drainage, roof ballast and thermal insulation, waterproofing, satellite dishes, retaining walls, underground garage ramp and its associated structures , and window washing equipment; (ii) Eaves, cornices and window sills to a maximum of 0.5 metres; (iii) Architectural elements to a maximum of 0.5 metres; (iv) Eaves, cornices, window sills and architectural elements to a maximum of 1.85 metres beyond the southerly main wall of the building , provided they are not located within areas that do not permit balconies as identified on Diagram 6, Diagram 7, Diagram 8, and Diagram 9; (v) Balconies to a maximum of 2.0 metres, provided such balconies are not located within areas that do not permit balconies as identified on Diagram 6, Diagram 7, Diagram 8, and Diagram 9; and (vi) Exterior building support columns that are located within the area identified as "HT 180.0" on Diagram 3, despite any requirements relating to the cantilevering of portions of the building
- Rule H
Clauses 50.10.40.30 and 50.10.40.31 with respect to building depth do not apply
- Rule I
Despite Regulations 50.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum elevation of 86.44 metres and the elevation of the highest point of the building or structure
- Rule J
Despite Regulations 50.10.40.10(1), (2) and (3), the permitted maximum height of a building or structure is the number in metres following the letters "HT" as shown on Diagram 3 of By-law 1192-2022(OLT)
- Rule K
Despite Regulations 50.5.40.10(3), (4), (5), (6) and (7), and (J) above, the following building elements and structures are permitted to project above the heights shown on Diagram 3 of By-law 1192-2022(OLT); (i) the structures , elements and enclosures permitted by (G) above; (ii) Parapet walls provided the maximum height of such elements is no higher than 2.0 metres above the height limits shown on Diagram 3; (iii) Privacy screens provided the maximum height of such elements is no higher than 3.0 metres above the height limits shown on Diagram 3; (iv) Structures used for outside or open air recreation, safety or wind protection purposes, provided the height of such elements is no higher than 3.4 metres above the height limits shown on Diagram 3; (v) Elements associated with a green roof , provided the height of such elements is no higher than 3.0 metres above the height limits shown on Diagram 3; (vi) Despite (G) or (K) (i), (ii), (iii), (iv) and (v) above, nothing is permitted to project above the area identified as "HT 180.0" on Diagram 3; (vii) Despite (K)(vi) above, within the area identified as "HT 180.0" on Diagram 3, chimneys, pipes and vents are permitted to project above a height of 180.0 metres, provided the maximum height of such elements is no higher than 3.0 metres; and (viii) Despite (K)(vi) above, for that portion of the building or structure identified as "Elevator Machine Room" on Diagram 3, elevator overruns and associated machine rooms for such elevator overruns, service rooms, and emergency exiting stairs, are permitted to project above a height of 180.0 metres, provided the height of these elements does not exceed the permitted maximum height by more than 7.0 metres, and that the total area of all such elements must not exceed an area of 150 square metres, measured horizontally
- Rule L
Despite Regulation 50.10.40.50(1) amenity space must be provided on the lands for the use of residents of the building in accordance with the following: (i) A minimum of 2.0 square metres of indoor amenity space per dwelling unit must be provided; and (ii) A minimum of 1.3 square metres of outdoor amenity space per dwelling unit must be provided
- Rule M
Despite Clause 200.5.10.1 and Article 200.20.10, parking spaces must be provided in accordance with the following: (i) a minimum of 0.2 residential occupant parking spaces for each dwelling unit ; (ii) a minimum of 0.25 parking spaces for each 100 square metres of non-residential gross floor area ; and (iii) Despite regulation 200.5.1.10(12)(C), the vehicle entrance or exit to the building must be at least 3.0 metres from the lot line abutting the street
- Rule N
Despite Regulation 200.5.10.1(1), and (M) above, "car-share parking spaces" may replace parking spaces otherwise required for residential occupants, subject to the following: (i) a reduction of 4 residential occupant parking spaces will be permitted for each "car-share parking space" provided, and that the maximum reduction permitted be 16 residential occupant parking spaces ; (ii) for the purpose of this exception, "car-share" means the practice whereby a number of people share the use of one or more motor vehicles and such "car-share" motor vehicles are made available to at least the occupants of the building for short-term rental, including hourly rental; and (iii) for the purpose of this exception, "car-share parking space" means a parking space exclusively reserved and signed for a vehicle used only for "car-share" purposes
- Rule O
Despite Clauses 220.5.10.1 and 50.10.90.40, a minimum of one loading space – Type "G" and one loading space – Type "C" must be provided on the lands in accordance with the requirements of Regulations 220.5.1.10(5), (6) and (8), and 220.5.20.1
- Rule P
Despite Regulations 230.5.1.10(10) and 230.50.1.20(1), "short term" bicycle parking spaces may be located in a stacked bicycle parking space .
Lot facts
- Area
- 1,111 m²
- Frontage
- 42.9 m
- Depth
- 26.1 m
- Street
- Pearl St
- Corner lot
- No
- Public lane
- None
- House footprint
- 771 m²roof up to 17.9 m
- Back yard
- 0 mhouse to rear lot line
- Side yards
- 0 m and 9 mhouse to side lot lines; 0 is a shared wall
- Buildings on the lot
- 1house, garage, sheds
- Max height
- 30 m
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
- Major Transit Station Area: Osgoode. The lot is inside the Osgoode Major Transit Station Area approved by the Province (Site and Area Specific Policy 609). Source
- King-Spadina Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
- Zone CRE (x28) (Commercial Residential Employment). Chapter 50, section 50.10 of the by-law. Source
Around this lot
- Minor variances approved
- 100%19 of 19 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 2
- Development applications
- 36
Within 300 m, last 10 years. 2 suite and multiplex permits: no more than at most Toronto houses (median 3). 19 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To alter the development standards, as approved under Site Specific Zoning By-law 135-2026 (OLT), for the 60-storey mixed-use building by converting the office spaces into residential units from floors 3 to 7, and to increase the number of storeys to 65-storeys; the building height from 202.5 m to 214 m (including the mechanical penthouse); and the maximum gross floor area. This is currently under the review of Site Plan Control (File No. 20 233433 STE 10 SA). There will be a total of 807 residential dwelling units on this lot.
277 WELLINGTON ST W · Apr 15, 2026 · 465 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 105-2022 (OLT)) for a 47-storey mixed-use building (containing 432 residential dwelling units, retail use on the ground level, and office use on second, third and fourth levels), by reducing the required number of vehicular parking spaces for the residents of this building.
263 ADELAIDE ST W · Jan 28, 2026 · 139 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 1219-2023(OLT) for a 61-storey mixed-use building, by increasing the building height to 67-storeys (223 m), the maximum gross floor area (residential and overall), a wind damper enclosure projection beyond the maximum building height, as well as to reduce the minimum non-residential gross floor area (remove the office uses), and reduce the number of loading spaces. There will be a total of 1,003 residential dwelling units on this lot (including 46 affordable units), subject to review under the related Site Plan Control Application (File 20 22 119164 STE 10 SA).
100 SIMCOE ST · Sep 10, 2025 · 97 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-laws 754-2021(OLT) and 757-2021(OLT)) for the 49-storey mixed-use building (currently under construction) by increasing the overall building height, and the total number of dwelling units from 612 to 630 units (by redesigning the penthouse units located on the 47, 48, and 49 floors into smaller units that will be accessed by the elevator overrun structure). Also, to reduce the number of parking spaces on-site.
400 KING ST W · Nov 27, 2024 · 471 m away - Minor varianceApproved
To alter the development standards, as approved under Site Specific Zoning By-law 851-2022, for the 34 and 41-storey mixed-use building, by increasing the residential gross floor area, and reducing the non-residential gross floor area as well as the easterly setback at levels 18 to 35. There will be a total of 479 residential dwelling units provided on this lot, currently under review through a Site Plan Control application (File Number 21 171254 STE 10 SA).
241 RICHMOND ST W · Oct 2, 2024 · 245 m away
Latest activity nearby
- Minor variancePending
To alter the existing 42-storey mixed-use building by constructing a side (west) one-storey addition (to enclose the existing patio with two new side (west) principal entrances for the existing eating establishment), abutting Wellington Street West.
155 WELLINGTON ST W · Nov 25, 2026 · 282 m away - Building permit
Proposed Interior build-out and alterations to an existing offices.
150 KING ST W · Nov 24, 2026 · 296 m away - Zoning review
Closed
136 SIMCOE ST · Nov 23, 2026 · 181 m away - Building permit
Proposal for interior alterations in existing vacant retail unit for new coffee shop.
154 UNIVERSITY AVE · Nov 23, 2026 · 185 m away - Building permit
Proposal for interior alterations on level 1 mezzanine of existing hotel. Work to include demolition of existing millwork, glass partitions of wine storage room, and indicated sections of the ceiling. Construction of new partitions, floor finishes, ceilings, millwork, and light fixtures.
181 WELLINGTON ST W · Nov 23, 2026 · 273 m away - Building permit
1 Ground Sign + 1 Overhanging Structure Sign ** MARIO FRESH FOOD/REXALL/HEALTHONE/FITLIFE**
200 WELLINGTON ST W · Nov 23, 2026 · 222 m away - Building permit
1 Ground Sign + 1 Overhanging Structure Sign ** MARIO FRESH FOOD/REXALL/HEALTHONE/FITLIFE **
200 WELLINGTON ST W · Nov 23, 2026 · 222 m away - Building permit
Proposal for localized loading dock slab concrete repairs and waterproofing replacement
180 WELLINGTON ST W · Nov 20, 2026 · 275 m away - Building permit
Proposed interior alterations to existing shower rooms.
200 WELLINGTON ST W · Nov 19, 2026 · 222 m away - Building permit
Install wall partitions, ceiling, plumbing & drainage connection to existing. Existing fire protection.
150 KING ST W · Nov 19, 2026 · 296 m away
Neighbourhood: Wellington Place
About the area around the lot, not the lot itself.
- Nearest station
- St. Andrew Station3 min walk
- Nearest TTC stop
- King St West at Simcoe St - St. Andrew Station3 min walk
- Nearest cycling route
- Adelaide St WCycle Track, 1 min walk
- Nearest traffic count
- 1,366 vehicles in 14 hPearl St / Duncan St / Ed Mirvish Way, 50 m away, Aug 11, 2026
- Serious collisions within 500 m
- 112021–2026, killed or seriously injured: 1 fatal, 5 with pedestrians, 4 with cyclists
- Parks
- Grasett Park4 min walk
- Simcoe Park5 min walk
- St. Patricks Square6 min walk
Schools within 1 km
- OCAD UNIVERSITY - INCLUSIVE DESIGN INSTITUTE University 7 min walk
- OCAD UNIVERSITY - STUDENT CENTRE University 8 min walk
- OCAD UNIVERSITY - ABOVEGROUND ART SUPPLIES University 9 min walk
- OCAD UNIVERSITY - MAIN BUILDING 416 977-6000 University 10 min walk
- OGDEN JR PUBLIC SCHOOL English Public 10 min walk
- OCAD UNIVERSITY - THE LEARNING ZONE University 11 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Wellington Place | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $90,000 | $84,500 |
| Households that own their home | 38% | 54% |
| Population (2021) | 25,570 | 16,813 |
| Homes built in 1960 or before | 2% | 29% |
| Homes needing major repairs | 1% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Wellington Place | City median |
|---|---|---|
| Assault | 1169.6 | 636.3 |
| Robbery | 82 | 69.5 |
| Homicide | 5.3 | 5.3 |
| Shootings | 10.6 | 10.5 |
| Auto theft | 97.9 | 192.6 |
| Theft over $5,000 | 87.3 | 46.1 |
| Break and enter | 293.7 | 172.8 |
| Theft from vehicles | 211.7 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.