Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
5 building permits open, the oldest since 1999
Needs a closer lookStill open in the City's records: 22 188134 (Proposal to convert the existing office (Group D) to learning centre(A2), 2023, status Permit Issued); 20 224018 (Proposal for interior alteration to demolish existing walls, ceilings, mechanical HVAC,..., 2021, status Inspection); 20 230017 (Facade Permit- Demolish Existing cladding- Readapt existing structural system and insta..., 2021, status Permit Issued); and 2 more.
What it means. An open permit can mean work that was never finished or never passed final inspection. After closing, finishing it or closing the file can fall to you.
How to confirm. Ask the seller for the final inspection records. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016)Work or applications in progress
Good to knowRecent records on this lot: 26 268391 (Interior alternations to existing group D suite, 2026); 22 132905 STE 12 SA (Site Plan application to permit a 61-storey multi-tower mixed use building with a maxim..., 2022); 21 213552 STE 12 SB (Draft Plan of Subdivision for the creation of 5 lots, 2021); and 1 more.
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications23 development applications open within 300 m
Good to know23 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 70 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
64 records on file: more than at 100% of Toronto houses (median 0).
- Building permit26 268391Permit Issued
Interior alternations to existing group D suite
Nov 12, 2026 · 150 EGLINTON AVE E - Building permit26 144339Closed
Proposed addition of Maglock door on level 3 between suites 300 and 308.
Apr 17, 2026 · 150 EGLINTON AVE E - By-law investigation26 145325 GRA 00 IRClosed
Graffiti
Apr 16, 2026 · 150 EGLINTON AVE E - Zoning review26 125425 ZZUClosedMar 5, 2026 · 150 EGLINTON AVE E
- Zoning review25 175704 PRZClosedJul 15, 2025 · 150 EGLINTON AVE E
- Development application25 175704 STE 12 OZClosed
Lift the H
Jun 11, 2025 · 150 EGLINTON AVE E · City file - Building permit25 135211Closed
1 projecting sign**Cleveland Clinic Canada**
Apr 2, 2025 · 150 EGLINTON AVE E - Building permit25 128999Cancelled
1 Projecting sign
Mar 14, 2025 · 150 EGLINTON AVE E
Show 56 older records
- Building permit22 188134Permit Issued
Proposal to convert the existing office (Group D) to learning centre(A2)
Aug 28, 2023 · 150 EGLINTON AVE E - Zoning review22 132905 PSPClosedApr 29, 2022 · 150 EGLINTON AVE E
- Development application22 132905 STE 12 SAUnder Review
Site Plan application to permit a 61-storey multi-tower mixed use building with a maximum gross floor area of 90,000 square metres, 201 parking spaces, 1,329 bicycle parking spaces, and a north-south midblock connection.
Apr 11, 2022 · 160 EGLINTON AVE E · City file - Building permit21 210192Closed
Application for a permit to erect and display three illuminated wall signs.*****MADISON*****
Feb 7, 2022 · 150 EGLINTON AVE E - Development application21 213552 STE 12 SBUnder Review
Draft Plan of Subdivision for the creation of 5 lots.
Sep 16, 2021 · 150 EGLINTON AVE E · City file - Zoning review21 184231 POZClosedAug 1, 2021 · 150 EGLINTON AVE E
- Development application21 184231 STE 12 OZCouncil Approved
Official Plan and Zoning By-law Amendment application to permit a 61-storey multi-tower mixed use building with1,329 residential units. Official Plan Amendment requested for relief from office replacement policies of the Yonge-Eglinton Secondary Plan.
Jul 14, 2021 · 160 EGLINTON AVE E · City file - Building permit20 224018Inspection
Proposal for interior alteration to demolish existing walls, ceilings, mechanical HVAC, Plumbing, electrical to build new showroom for condominium sales office.
Mar 19, 2021 · 150 EGLINTON AVE E - Building permit20 230017Permit Issued
Facade Permit- Demolish Existing cladding- Readapt existing structural system and install new facade cladding.
Feb 12, 2021 · 150 EGLINTON AVE E - Building permit20 104851Closed
Proposal for interior alterations of an existing Office into a Medical Office, at the 3rd Floor of an Existing Commercial Building.
Feb 12, 2020 · 150 EGLINTON AVE E - Zoning review19 221562 LPRClosedSep 16, 2019 · 150 EGLINTON AVE E
- Building permit19 140824Closed
Proposal to install new kitchen exhaust system in restaurant "CopaCabana".
Jun 7, 2019 · 150 EGLINTON AVE E - Building permit19 109806Closed
Proposal for interior alterations to the 5th Floor of existing office building - "Cleveland Clinic"
Mar 27, 2019 · 150 EGLINTON AVE E - Zoning review18 193672 LPRClosedJul 13, 2018 · 150 EGLINTON AVE E
- Building permit18 138583Closed
Proposal for interior alterations to the 5th Floor Communications Room in existing office. "Cleveland Clinic", in an Existing Commercial Building.
Apr 30, 2018 · 150 EGLINTON AVE E - Building permit17 278791Closed
Proposal for an enlarged bar a related plumbing work. Scope of work also includes replacing water closets and fixtures in bathrooms / kitchen area.
Jan 31, 2018 · 150 EGLINTON AVE E - Zoning review17 127043 LPRClosedMar 9, 2017 · 150 EGLINTON AVE E
- Zoning review16 262922 ZPRClosedDec 11, 2016 · 150 EGLINTON AVE E
- Building permit16 192711Closed
Interior alterations to existing office space on the 10th floor. Tenant - "CITY OF TORONTO EMPLOYMENT AND SOCIAL SERVICES".
Aug 12, 2016 · 150 EGLINTON AVE E - Building permit16 150978Inspection
Proposed electromagnetic locks on 9th floor.
May 31, 2016 · 150 EGLINTON AVE E - Building permit15 225022Closed
In conjunction with a multi-storey building on the premises, proposal to erect and display one third party illuminated wall sign displaying static copy, located on the westerly facing building wall. The proposed sign is 4.878 metres vertically by 3.658 metres horizontally at a height of 14.02 metres.**ASTRAL**
Nov 27, 2015 · 150 EGLINTON AVE E - Building permit15 176584Closed
Proposal for interior alterations to the 9th floor of existing office - tenant is "Toronto Employment and Social Services"
Jul 20, 2015 · 150 EGLINTON AVE E - Zoning review15 139305 PRZClosedApr 23, 2015 · 150 EGLINTON AVE E
- Development application15 139305 STE 22 OZClosed
Proposal for site plan approval for a 46 storey mixed use building.
Apr 10, 2015 · 150 EGLINTON AVE E · City file - Zoning review15 125685 ZPRClosedMar 10, 2015 · 150 EGLINTON AVE E
- Building permit15 109179Closed
Proposal for interior alterations to existing office space on the 6th floor - Unit 601
Feb 24, 2015 · 150 EGLINTON AVE E - Zoning review15 113546 LPRClosedFeb 9, 2015 · 150 EGLINTON AVE E
- Building permit13 204334Closed
Proposal for interior alterations to the ground floor lobby of existing office building.
Jul 29, 2013 · 150 EGLINTON AVE E - Building permit10 280962Closed
Proposal for interior alterations on the 9th floor, unit 900, for existing office tenant "City of Toronto Employment & Social Services" (110m2).
Nov 3, 2010 · 150 EGLINTON AVE E - Building permit10 200164Closed
Proposal to install 2 back flow prevention device to existing mixed use building.
Jul 12, 2010 · 150 EGLINTON AVE E - Building permit10 116096Closed
Proposal to install 2 new canopies, make up air, and ecology unit in ezxisting restaurant (greater than 30) on the ground floor.
Jun 16, 2010 · 150 EGLINTON AVE E - Zoning review10 120196 ZSVClosedFeb 18, 2010 · 150 EGLINTON AVE E
- Building permit08 160159Closed
Revision to 2nd floor hallway doors. Interior alterations to exisitng office space - floor 2 - Tenant: King George Internation College. KGIC
Aug 11, 2008 · 150 EGLINTON AVE E - Building permit08 163125Closed
Minor interior alteration to increase size of classrooms on the 7th floor. tenant - "King George International College".
Jun 11, 2008 · 150 EGLINTON AVE E - Building permit04 201171Closed
RELOCATE OFFICE PARTION ON 9TH FLOOR
Dec 16, 2004 · 150 EGLINTON AVE E - Building permit04 157064Closed
Interior alterations to 6th floor
Jul 15, 2004 · 150 EGLINTON AVE E - Zoning review03 177744 LTOClosedSep 23, 2003 · 150 EGLINTON AVE E
- Zoning review02 190779 LTOClosedNov 21, 2002 · 150 EGLINTON AVE E
- Zoning review02 190636 LTOClosedNov 20, 2002 · 150 EGLINTON AVE E
- Building permit02 134401Closed
Interior renovation to 5th floor existing sport medicine clinic.
May 9, 2002 · 150 EGLINTON AVE E - Building permit01 202395Closed
Install partition within unit #604 of the existing office building
Dec 13, 2001 · 150 EGLINTON AVE E - Zoning review00 335458 000ClosedSep 8, 2000 · 150 EGLINTON AVE E
- Building permit99 013363Closed
INSTALL PLUMBING FIXTURES 2ND FLOOR: 1 W.B., 3 CUSPITORS, 5 DENTAL SINKS, 3 KITCHEN SINKS REFER TO APPLICATION NUMBER: 422458
Mar 19, 1999 · 150 EGLINTON AVE E - Building permit99 012271Inspection
REMOVE NON LOAD BEARING PARTITIONS ON 8TH FLOOR, PUBLIC CORRIDOR AND ALL LIFE SAFETY SYSTEM COMPONENTS TO BE MAINTAINED SS
Mar 17, 1999 · 150 EGLINTON AVE E - Building permit98 025154Cancelled
ALTER PLANS AS APPROVED UNDER FILE 393454 BY MAKING FURTHER INTERIOR ALTERATION TO WASHROOMS IN EXISTING RESTAURANT (390 SEATS) ON FIRST FLOOR. /LM "SWEET WATER RESTAURANT"
Feb 18, 1999 · 150 EGLINTON AVE E - Building permit98 023280Closed
REMOVE SKYLIGHT AND MAKE SOFFIT ALTERATIONS.
Oct 28, 1998 · 150 EGLINTON AVE E - Building permit96 024022Cancelled
MAKE INTERIOR ALTERATIONS TO INCREASE OCCUPANT LOAD (390 SEATS MAX). HOLD FOR HEALTH DEPT APPR. BP
Mar 24, 1997 · 150 EGLINTON AVE E - Zoning review96 025269 LTOClosedJul 17, 1996 · 150 EGLINTON AVE E
- Zoning review92 026286 LTOClosedDec 9, 1992 · 150 EGLINTON AVE E
- Zoning review92 025961 LTOClosedSep 18, 1992 · 150 EGLINTON AVE E
- Zoning review91 026631 LTOClosedJun 21, 1991 · 150 EGLINTON AVE E
- Zoning review91 026372 LTOClosedApr 24, 1991 · 150 EGLINTON AVE E
- Building permit91 012544Closed
CONSTRUCT ACCESS RAMP AT FRONT.
Feb 11, 1991 · 150 EGLINTON AVE E - Zoning review86 028158 LTOClosedJun 2, 1986 · 150 EGLINTON AVE E
- Zoning review85 026962 LTOClosedSep 25, 1985 · 150 EGLINTON AVE E
- Zoning review82 026754 LTOClosedDec 29, 1982 · 150 EGLINTON AVE E
Check before you build
Site-specific exception 900.11.10(148)
Needs a closer look26 site-specific rules and 3 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
On 150 Eglinton Avenue East, if the requirements of Section 5 and Schedule A of By-law 1216-2018 are complied with, none of the provisions of regulations 40.10.40.10(2) and 40.10.40.40(1) apply to prevent the use or erection of a mixed-use building if it complies with
- Rule B
to (T) below; (B) Prevailing Sections 12(2)118, 12(2)119 and 12(2)270(a) of former City of Toronto By-law 438-86 do not apply
- Rule C
Despite regulations 5.10.40.70(1) and 40.10.40.70(2), the above grade portion of a building or structure must be located entirely within the area delineated by heavy lines shown on Diagram 3 of By-law 1216-2018
- Rule D
Despite regulations 40.10.40.60 and (C) above, the following elements are permitted to encroach beyond the heavy lines shown on Diagram 3 of By-law 1216-2018 to a maximum of 2.6 metres: (i) balconies, cornices, lighting fixtures, window washing equipment, awnings, canopies, finials, parapets, terraces, terrace guards, platforms ornamental or architectural elements, trellises, eaves, window sills, bay windows, canopies, guardrails, balustrades, railings, wind mitigation screens and features, planters, monuments, arbours, patios, decorative features, stairs, stair enclosures, stair landings, supportive columns, wheel chair ramps, vents, stacks, wind screens and features, acoustic screens and features, underground garage ramps and their associated structures , underground garage stair enclosures, retaining walls, fences, screens, weather protection canopies, and landscape and public art features
- Rule E
Despite regulation 40.5.40.10(1) the height of the building or structure is the distance between Canadian Geodetic Datum elevation of 162.13 metres and the elevation of the highest point of the building or structure
- Rule F
Despite regulation 40.10.40.10(2), the permitted maximum height of a building or structure is the height in metres specified by the numbers following the symbol HT on Diagram 3 of By-law 1216-2018
- Rule G
Despite regulation 40.10.40.10(7), the permitted maximum number of storeys of a building or structure on the lot is the numerical value following the letters ST on Diagram 3 of By-law 1216-2018
- Rule H
Despite 40.5.40.10(3)-(7) and (F) above, the following elements may project above the heights specified by the numbers following the symbol HT on Diagram 3 of By-law 1216-2018; (i) a parapet, roof drainage, thermal insulation or roof ballast, to a maximum of 1.8 metres; (ii) safety railings and fences to a maximum of 1.8 metres, and having a maximum combined vertical dimension with (i) above of 2.75 metres; and (iii) structures on the roof of any part of the building used for outside or open air recreation, green roof elements, wind mitigation elements, landscape features, architectural elements, elevator overruns, public art features, telecommunications equipment and antennae, window washing equipment, stair towers, partitions dividing outdoor recreation areas, trellises or a fence, planters, landscape features, walls or structures enclosing such elements, lightning rods and exhaust flues, swimming pools (elevated or otherwise), structures housing pool or spa maintenance or operational equipment, to a maximum of 4.0 metres
- Rule I
Within the portion of the building labelled ST= 7 on Diagram 3 of By-law 1216-2018; one storey must be provided exclusively for bicycle parking spaces
- Rule J
Despite regulation 40.5.40.40(3) any area used for public parking may be reduced from the area used for the calculation of gross floor area for a mixed use building
- Rule K
Despite regulation 40.10.40.40(1) the permitted maximum building gross floor area is 45,910 square metres
- Rule L
A minimum of 8,500 square metres of the gross floor area permitted in (K) above, must be for office use
- Rule M
A maximum of 429 dwelling units are permitted, of which: (i) a minimum 30 percent of dwelling units must contain at least two-bedrooms; and (ii) a minimum 10 percent of dwelling units must contain at least three-bedrooms
- Rule N
Despite regulation 40.10.40.50(1) a minimum of 950 square metres of indoor amenity space and 970 square metres of outdoor amenity space must be provided
- Rule O
Despite clause 220.5.10.1, 1 Type "G", 1 Type "B", and 2 Type "C" loading spaces must be provided
- Rule P
Despite clause 200.5.10.1 the minimum number of required parking spaces is: (i) A minimum of 130 parking spaces for the dwelling units ; (ii) A minimum of 103 parking spaces to be shared by the residential visitors and non-residential uses; and (iii) For each car-share parking space provided, the minimum number of parking spaces required by (i) above shall be reduced by 4 parking spaces up to a maximum of 10 car-share parking spaces
- Rule Q
Despite regulation 40.5.80.1(1) parking spaces required in (P)(ii) above may be located within a public parking garage and may be available on a first-come-first-serve basis
- Rule R
Despite regulation 200.5.1.10(2), a maximum of 10 parking spaces may have a minimum width of 2.4 m, a minimum length of 5.4 m, and a minimum height of 1.7 metres with or without obstructions
- Rule S
Despite regulation 200.5.1.10(12)(A) the vehicle entrance and exit for a two-way driveway into and out of the building must have a minimum width of 5.0 metres
- Rule T
Despite regulation 230.5.1.10(4) the platform of a stacked bicycle parking space may have minimum dimensions of 0.5 metres by 1.6 metres, and a minimum vertical clearance for each space of 1.2 metres
- Rule U
Regulation 40.10.20.100(8), relating to the access condition for public parking, does not apply
- Rule V
Regulation 40.10.50.10(3), relating to landscaping requirement if abutting a lot in the Residential or Residential Apartment Zone Category, does not apply
- Rule W
Regulation 40.10.90.40(2), relating loading restrictions if adjacent to a lot in a Residential Zone Category or Residential Apartment Zone Category, does not apply
- Rule X
Regulation 40.10.100.10.(2), relating access to parking areas if adjacent to a Lot in a Residential Zone Category or Residential Apartment Zone Category, does not apply
- Rule Y
Regulation 230.5.1.10.(9), relating to the long term location, does not apply
- Rule Z
Despite the provisions of By-law 569-2013, as amended, and By-law 1216-2018 a temporary sales office shall be permitted on the lot .
- Older by-law A
Sections 12(2)118 of former City of Toronto By-law 438-86
- Older by-law B
12(2)119 of former City of Toronto By-law 438-86
- Older by-law C
12(2)270(a) of former City of Toronto By-law 438-86
Lot facts
- Area
- 3,005 m²
- Frontage
- 53.3 m
- Depth
- 56.4 m
- Street
- Eglinton Ave E
- Corner lot
- Yes, also on Lillian St56.4 m along it
- Public lane
- None
- House footprint
- 1,317 m²roof up to 47 m
- Back yard
- 29 mhouse to rear lot line
- Side yards
- 0.9 m and 3.4 mhouse to side lot lines
- Buildings on the lot
- 3house, garage, sheds
- Max height
- 48 m
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
- Major Transit Station Area: Eglinton. The lot is inside the Eglinton Major Transit Station Area approved by the Province (Site and Area Specific Policy 723). Source
- Yonge-Eglinton Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Zone CR 5.0 (c3.0; r3.0) SS2 (x148) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
Around this lot
- Minor variances approved
- 100%10 of 10 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 0
- Development applications
- 51
Within 300 m, last 10 years. 0 suite and multiplex permits: no more than at most Toronto houses (median 3). 10 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To alter the development standards for the 38-storey mixed-use building (approved under Site Specific Zoning By-Law 153-2022(OLT)), to permit six obstructed parking spaces with a reduced width (located on parking levels P1 to P5).
2161 YONGE ST · Aug 19, 2026 · 465 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 153-2022(OLT)) for a 38-storey mixed-use building by increasing the residential gross floor area (for a total of 380 residential dwelling units), reducing the commercial (office) gross floor area, and reducing the number of required parking spaces. Also, to permit a home occupation use (personal service shop) within the building, and to reduce the required width of 4 obstructed parking spaces.
2161 YONGE ST · Aug 14, 2024 · 465 m away - Minor varianceRefused
To permit the addition of 4 storeys above the approved 23 storey building, as well as squaring off the curvature nature of the west façade by reducing the north, south and west tower setbacks. Please note this application was previously deferred Thursday, July 27, 2023.
717 MOUNT PLEASANT RD · Dec 7, 2023 · 412 m away - Minor varianceApproved
To alter Site Specific Zoning By-law 153-2022 (Ontario Land Tribunal (OLT)) to increase the mixed-use building height, increase the total maximum gross floor area, increase the total residential gross floor area, and reduce the minimum length of 26 parking spaces.
2161 YONGE ST · Aug 9, 2023 · 465 m away - Minor varianceApproved
To alter the existing two-storey commercial building by converting the second-floor into recreational space.
2295 YONGE ST · Mar 3, 2021 · 332 m away
Latest activity nearby
- Building permit
Interior alternations to existing group D suite
150 EGLINTON AVE E · Nov 12, 2026 · 13 m away - Building permit
Designing and installing a sprinkler modification system
110 EGLINTON AVE E · Nov 10, 2026 · 100 m away - Building permit
REVISION-01: ON THE 3RD FLOOR REDUCES THE AREA OF SUITE #302 TO CREATE A SECOND SUITE FOR FUTURE LEASEPROPOSED INTERIOR ALTERATIONS ON 3RD FLOOR FOR OFFICE SUITE FITOUT.
240 EGLINTON AVE E · Nov 10, 2026 · 248 m away - Building permit
Backflow Device Replacement
244 EGLINTON AVE E · Nov 5, 2026 · 264 m away - Building permit
Proposal for interior alterations to an office for a tenant fit up.
90 EGLINTON AVE E · Nov 4, 2026 · 152 m away - Zoning review
Closed
20 EGLINTON AVE E · Nov 3, 2026 · 298 m away - Building permit
Proposal for interior alterations to expand existing laundry room and install a universal washroom.
130 EGLINTON AVE E · Oct 23, 2026 · 39 m away - Building permit
Wholesale replacement of exterior sealants. Wholesale replacement off vent grills. Localized masonry repairs including brick replacement and mortar joint repointing. Localized concrete balcony slab surface and slab edge repairs. Localized surface repairs at deteriorated EIFS cladding.
123 EGLINTON AVE E · Oct 21, 2026 · 77 m away - Building permit
Proposal to install two Maglocks - doors P100b and P00b at the level P1.
170 ROEHAMPTON AVE · Oct 14, 2026 · 144 m away - Zoning review
Closed
20 EGLINTON AVE E · Oct 13, 2026 · 298 m away
Neighbourhood: North Toronto
About the area around the lot, not the lot itself.
- Nearest station
- Mount Pleasant Station5 min walk
- Nearest TTC stop
- Eglinton Ave East at Dunfield Ave1 min walk
- Nearest cycling route
- Eglinton Ave ECycle Track, 4 min walk
- Nearest traffic count
- 15,189 vehicles in 14 hEglinton Ave E / Lillian St, 40 m away, Jan 29, 2026
- Serious collisions within 500 m
- 32021–2026, killed or seriously injured: 1 fatal, 3 with pedestrians, 0 with cyclists
- Parks
- 60 Broadway Ave Park5 min walk
- Dunfield Park5 min walk
- Raccoon Park5 min walk
Schools within 1 km
- CAREERQUEST Private 1 min walk
- WILLOWDALE HIGH SCHOOL Private 1 min walk
- EGLINTON LINC AND ESL CENTRE English Separate 2 min walk
- EGLINTON JR PUBLIC SCHOOL English Public 4 min walk
- NORTH TORONTO COLLEGIATE INSTITUTE English Public 5 min walk
- CAESAR INTERNATIONAL ACADEMY Private 5 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | North Toronto | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $70,000 | $84,500 |
| Households that own their home | 19% | 54% |
| Population (2021) | 15,885 | 16,813 |
| Homes built in 1960 or before | 9% | 29% |
| Homes needing major repairs | 4% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | North Toronto | City median |
|---|---|---|
| Assault | 626.8 | 636.3 |
| Robbery | 53.4 | 69.5 |
| Auto theft | 68 | 192.6 |
| Theft over $5,000 | 24.3 | 46.1 |
| Break and enter | 174.9 | 172.8 |
| Theft from vehicles | 63.2 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.