Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
Heritage property: in a Heritage Conservation District (Part V)
Needs a closer lookOn the City's Heritage Register. Demolition and exterior changes need heritage review.
What it means. Renovations, additions and demolition can take longer, cost more or be refused.
How to confirm. Heritage Planning at the City confirms the status and what it covers. Details
City of Toronto Heritage RegisterWork or applications in progress
Good to knowRecent records on this lot: 24 229071 STE 10 OZ (Combined Official Plan Amendment (OPA) & Zoning By-law Amendment (ZBA) application for..., 2024); 20 191102 STE 10 SA (Site Plan Control Application to facilitate a new mixed-use building comprised of a 13-..., 2020).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications7 development applications open within 300 m
Good to know7 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 80 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
84 records on file: more than at 100% of Toronto houses (median 0).
- Building permit26 151581Closed
Modification of existing installed HVAC to add an additional HVAC zone via the installation of a new terminal box and rebalancing of the local ductwork.
May 25, 2026 · 145 WELLINGTON ST W - Building permit24 237935Closed
Interior alteration to offices in Suite 203, creation of a new meeting room and installation of a movable wall.
Nov 27, 2024 · 145 WELLINGTON ST W - Zoning review24 229071 POZClosedNov 13, 2024 · 145 WELLINGTON ST W
- Development application24 229071 STE 10 OZUnder Review
Combined Official Plan Amendment (OPA) & Zoning By-law Amendment (ZBA) application for a proposal to amend By-law 1015-2022, the proposed 65-storey residential tower with ground floor retail. The proposal includes 54,010 sqaure metres of residential GFA, 206.3 square metres of retail GFA and 861 dwelling units.
Oct 21, 2024 · 145 WELLINGTON ST W · City file - Building permit24 180612Closed
Proposal to demolish existing partitions to create large open area, add one closet and adjust some office partitions
Aug 14, 2024 · 145 WELLINGTON ST W - Building permit24 170020Closed
Proposed subdivide of the existing space to create conference rooms and general office area with kitchen.
Aug 1, 2024 · 145 WELLINGTON ST W - Zoning review19 210278 PRZClosedFeb 2, 2022 · 145 WELLINGTON ST W
- Building permit21 246954Closed
interior alterations to existing office 4th Floor
Dec 23, 2021 · 145 WELLINGTON ST W
Show 76 older records
- Zoning review20 191102 PSPClosedOct 22, 2020 · 145 WELLINGTON ST W
- Development application20 191102 STE 10 SAUnder Review
Site Plan Control Application to facilitate a new mixed-use building comprised of a 13-storey podium, and a 52-storey residential tower above. Proposal includes 14,662 m² non-residential floor area and 472 new purpose-built rental units. Proposal also includes reconfiguration of portions of Wellington Street West adjacent to site.
Sep 8, 2020 · 145 WELLINGTON ST W · City file - Building permit19 196287Closed
Proposal for interior alterations to the 8th floor of the existing office building, scope of work is to construct a partition wall with new door.
Sep 4, 2019 · 145 WELLINGTON ST W - Development application19 210278 STE 10 OZClosed
Zoning By-law amendment application to permit a 60-storey mixed-use building consisting of a 13-storey office podium, and a 47-storey residential tower above. The proposal includes 14,540 m² non-residential floor area and 512 dwelling units.
Aug 22, 2019 · 145 WELLINGTON ST W · City file - Building permit18 242745Closed
REV01- change to floor layout to include two tenants on one floor.Proposal for interior alterations to existing office building. unit 400
Apr 11, 2019 · 145 WELLINGTON ST W - Building permit18 130200Closed
Proposed smoke rating of corridor on the 14th floor.
Mar 28, 2018 · 145 WELLINGTON ST W - Building permit17 235709Closed
REV 01: Deletion of door 201, addition of office 206 & 207, addition of doors 206 & 207Proposal to construct partitionsin existing office - Unit 203 with no specific tenant proposed. A separate permit for occupancy is required.
Jan 29, 2018 · 145 WELLINGTON ST W - Building permit17 241091Closed
Proposed interior alterations to existing vacant office space for tenant fit-out.
Dec 7, 2017 · 145 WELLINGTON ST W - Building permit17 158418Closed
Interior alteration to an office on the 5th floor of the existing building.
May 29, 2017 · 145 WELLINGTON ST W - Building permit17 157416Closed
Construct interior alterations for Jarvis & Assicates (186.6m2) Suite 501
May 25, 2017 · 145 WELLINGTON ST W - Building permit17 134358Closed
Proposed minor interior alterations to office space in Unit 205.
Apr 11, 2017 · 145 WELLINGTON ST W - Building permit17 128527Closed
Proposed interior alterations to the existinmg office space on the 5th floor
Mar 20, 2017 · 145 WELLINGTON ST W - Building permit17 116940Closed
Interior alterations to existing office space on the 9th floor. Suite 901. Tenant - "American Express".
Mar 16, 2017 · 145 WELLINGTON ST W - Building permit16 249623Closed
Interior alterations to an existing office (192.35m2)
Dec 14, 2016 · 145 WELLINGTON ST W - Building permit16 238730Closed
Proposal for interior alterations to existing Group D (office) suite.
Nov 7, 2016 · 145 WELLINGTON ST W - Building permit16 200473Closed
Proposal for interior alterations to existing office suite. Tenant is 'H&R Reit'. Unit #207.
Sep 7, 2016 · 145 WELLINGTON ST W - Building permit16 210227Closed
Proposal for interior alterations in south corridor on floor 9.
Sep 1, 2016 · 145 WELLINGTON ST W - Building permit16 212288Cancelled
install new maglocks to floor 9 -14
Aug 24, 2016 · 145 WELLINGTON ST W - Building permit16 190543Closed
Proposal for interior alterations to the 10th floor of existing office - "National Film Board"
Aug 9, 2016 · 145 WELLINGTON ST W - Building permit16 184920Closed
Proposal for interior alterations to the 12th floor for tenant (Jones Brown) in the existing office building.
Jul 25, 2016 · 145 WELLINGTON ST W - Building permit16 167264Closed
Proposal to install 2 electromagnetic locks on the 11th floor.
Jul 11, 2016 · 145 WELLINGTON ST W - Building permit16 165709Closed
Proposal to upgrade 39 electromagnetic locks on: ground floor, 2nd floor, 3rd floor, 4th floor, 5th floor, 11th floor, 12th floor, 14th floor, P1, P2 and P3.
Jun 24, 2016 · 145 WELLINGTON ST W - Building permit16 153676Closed
Proposal for interior demolition to existing office space on floors 6, 7, 8, 9, 10 and 14.and construction of a very small length [approx 6 linear metres] of partitions on 9th storey.[per email in file]
Jun 17, 2016 · 145 WELLINGTON ST W - Building permit16 145570Closed
Permit to install (8) Maglocks on Floors 6, 7, & 8.
May 19, 2016 · 145 WELLINGTON ST W - Building permit16 139740Closed
Proposal for interior alterations to the 11th floor of existing office - tenant is "RBC"
May 13, 2016 · 145 WELLINGTON ST W - Building permit16 114855Closed
Proposal for interior alterations to existing office space on floors 6, 7 and 8 - "Touchstone Institute".
Mar 22, 2016 · 145 WELLINGTON ST W - Building permit16 122974Closed
Landlord base building upgrades to the 10th floor common corridor including for the installation of one univesal washroom faclitity.
Mar 16, 2016 · 145 WELLINGTON ST W - Building permit15 265896Closed
Proposal for interior alterations and new demising wall in unit 901 of the existing office building.
Jan 18, 2016 · 145 WELLINGTON ST W - Building permit15 263236Closed
Proposal for interior alterations to the 2nd floor vacant offices in suites 201, 205, 207, and 209.
Dec 17, 2015 · 145 WELLINGTON ST W - Building permit15 233102Closed
In conjunction with a multi-story building, proposal erect and display two static illuminated wall signs on the first storey northerly and westerly building walls. The proposed northerly facing wall sign measures at 0.5 metres vertically by 12.63 metres horizontally at a height of 2.63 metres above grade, The proposed westerly facing wall sign measures at 0.5 metres vertically by 19.86 metres horizontally at a height of 2.63 metres above grade. **MERIDIAN**
Nov 10, 2015 · 145 WELLINGTON ST W - Building permit15 205743Closed
INTERIOR ALTERATIONS TO DECOMISSION AND VACATE EXISTING TENANT, "AIG CANADA" INCLUDING SELECTIVE DEMOLITION AND REMOVAL OF 16 ELECTROMAGNETIC LOCKS.
Aug 21, 2015 · 145 WELLINGTON ST W - Building permit15 186881Cancelled
FS - Sprinkler Shop Drawing - Proposal for interior alterations to unit 101 for Meridian Credit Union in the existing office building.
Aug 10, 2015 · 145 WELLINGTON ST W - Building permit14 263613Closed
Interior Alterations on the 2nd floor for the creation of a unisex barrier free washroom H&R Reit.
Dec 16, 2014 · 145 WELLINGTON ST W - Building permit14 213559Closed
Proposal to construct interior alterations to the 3rd floor of the existing office building.
Sep 9, 2014 · 145 WELLINGTON ST W - Building permit13 131231Closed
Proposal to install 1 maglock on the 4th floor - "CMLS FINANCIAL".
Apr 9, 2013 · 145 WELLINGTON ST W - Zoning review13 126591 LPRClosedFeb 28, 2013 · 145 WELLINGTON ST W
- Building permit13 105709Closed
Proposal for interior alterations (238m2) to suite 400 in existing office building "CMLS Financial".
Jan 28, 2013 · 145 WELLINGTON ST W - Building permit11 319223Closed
This is for interior alterations to the 5th floor for a new office layout. This will include HVAC and Plumbing.
Dec 21, 2011 · 145 WELLINGTON ST W - Building permit11 309244Closed
Proposal for interior alterations to existing stairwell on floors 4 and 5.
Nov 28, 2011 · 145 WELLINGTON ST W - Building permit11 235953Closed
Proposal for interior alterations to 14th floor office space. Tenant is CHARTIS.
Aug 4, 2011 · 145 WELLINGTON ST W - Zoning review11 193424 LPRClosedMay 12, 2011 · 145 WELLINGTON ST W
- Building permit10 269613Closed
Proposal to install 1 backflow prevention device in an existing multi use non residential building.
Oct 28, 2010 · 145 WELLINGTON ST W - Building permit10 262953Closed
Proposal for interior alterations to 9th and 10th floors (242m2) for existing tenant "Chartis".
Sep 24, 2010 · 145 WELLINGTON ST W - Building permit09 157788Closed
Proposal to install 2 electromagnetic locks in existing second floor office space. Tenant is H & R Developments.
Sep 8, 2009 · 145 WELLINGTON ST W - Zoning review09 162122 LPRClosedAug 25, 2009 · 145 WELLINGTON ST W
- Building permit06 158195Closed
Interior alterations to an existing office space on the 2nd floor
Aug 2, 2006 · 145 WELLINGTON ST W - Building permit06 135719Closed
Interior alterations to construct a new public corridor on the 2nd floor of an existing office building
May 26, 2006 · 145 WELLINGTON ST W - Building permit05 211732Closed
HVAC - Interior alterations to existing office on the 2nd floor to alter from 1 tenant to 2 tenants. - Interior Alterations
Jan 10, 2006 · 145 WELLINGTON ST W - Building permit05 131878Closed
Install 17 electro-magnetic locking devices. 4 - 6th fl., 1 - 7th fl., 2 - 8th fl., 2 - 10th fl., 4 - 11th fl., 2 - 12th fl., 2 - 14th fl.
May 12, 2005 · 145 WELLINGTON ST W - Building permit05 102837Closed
HVAC - Interior alteration to an existing office space on to sixth through the fourteenth floor - Interior Alterations
Mar 9, 2005 · 145 WELLINGTON ST W - Building permit05 103506Closed
Parking garage concrete slab repairs.
Jan 26, 2005 · 145 WELLINGTON ST W - Building permit04 159234Closed
Make interior alterations to the ground floor.
Jul 22, 2004 · 145 WELLINGTON ST W - Building permit03 191709Closed
Make interior alterations to lobby & washrooms on floors 1-12.
Dec 22, 2003 · 145 WELLINGTON ST W - Building permit03 124886Closed
Alter plans as approved under file 03 - 124886 by constructing a raised floor over portion of the 6th floor. Tenant: Aon Consulting
May 15, 2003 · 145 WELLINGTON ST W - Building permit03 118518Closed
interior partitions removal
Mar 27, 2003 · 145 WELLINGTON ST W - Building permit01 102410Closed
Intall 4 maglocks @ 2/f
Jan 11, 2001 · 145 WELLINGTON ST W - Building permit00 356539Closed
Install fixtures on the 2nd floor office: 1 kitchen sink, 1 d.w., 1 w.b., 1 shower Tenant: Vengrowth Funds cost incl. 00 - 356532
Dec 4, 2000 · 145 WELLINGTON ST W - Building permit00 356532Closed
Install partitions on the 2nd floor office.Tenant: Vengrowth Funds
Nov 24, 2000 · 145 WELLINGTON ST W - Building permit00 343586Closed
4 maglocks on 3rd floor
Oct 5, 2000 · 145 WELLINGTON ST W - Building permit00 333484Closed
alter existing h.v.a.c system on portion of 3th fl . unit 300 & portion of 4th floors, unit 400--cost incl. under file #00-333474
Sep 18, 2000 · 145 WELLINGTON ST W - Building permit00 333474Closed
install partitions on portion of 3th fl . unit 300 & portion of 4th floors, unit 400 FASTRACK
Sep 7, 2000 · 145 WELLINGTON ST W - Zoning review00 012100 LTOClosedJan 21, 2000 · 145 WELLINGTON ST W
- Building permit99 019401Closed
RELOCATION OF DUCTS AND DIFFUSERS ON PORTION OF 9TH FLOOR OFFICE REFER TO APPLICATION NUMBER: 428604 TENANT: AMERICAN HOME ASSURANCE CO
Aug 10, 1999 · 145 WELLINGTON ST W - Building permit99 019403Closed
INSTALL PLUMBING FIXTURES 9TH FLOOR 1 K.S. REFER TO APPLICATION NUMBER: 428604
Jul 29, 1999 · 145 WELLINGTON ST W - Building permit98 018590Closed
INSTALL KITCHEN EXHAUST SYSTEM ON 5TH FLOOR. BP COST INCL: 411912
Jul 7, 1998 · 145 WELLINGTON ST W - Building permit98 016327Closed
INSTALL PARTITIONS ON 3RD,4TH AND 5TH FLOORS. BP 2972.8M\2
Jun 3, 1998 · 145 WELLINGTON ST W - Building permit98 016743Closed
INSTALL PLUMBING FIXTURES ON 3RD FLOOR: 1 K.S., 1 H.W.T., ON 4TH FLOOR: 1 K.S., 1 H.W.T., ON 5TH FLOOR: 2 K.S., 2 H.W.T. REFER TO APPLICATION NUMBER: 411912 TENANT: AON CONSULTING INC. EDC
May 15, 1998 · 145 WELLINGTON ST W - Building permit97 021391Closed
ALTER EXISTING H.V.A.C. SYSTEM ON PORTION OF THE 7TH FLOOR OFFICE. TENANT: AMERICAN INTERNATIONAL GROUP COST INCL. 403204 /LM
Dec 4, 1997 · 145 WELLINGTON ST W - Building permit97 021301Closed
MAKE INTERIOR ALTERATIONS TO PORTION OF 3RD FLOOR EXISTING OFFICE FOR NEW TENANT. TENANT: WARD ASSOCIATES. EDC
Sep 11, 1997 · 145 WELLINGTON ST W - Building permit97 014751Closed
HVAC ALTERATIONS ON 2ND FLOOR. COST INCL:396550 BP
Apr 23, 1997 · 145 WELLINGTON ST W - Zoning review97 025830 LTOClosedJan 22, 1997 · 145 WELLINGTON ST W
- Building permit96 021101Closed
MAKE INTERIOR ALTERATIONS ON 1ST FLOOR. BP
Nov 19, 1996 · 145 WELLINGTON ST W - Building permit96 022276Closed
ALTER HVAC SYSTEM ON 11TH FLOOR COST INCL. WITH APPL.391704 SS
Nov 4, 1996 · 145 WELLINGTON ST W - Building permit95 013959Closed
INSTALL H.V.A.C. SYSTEM ON PORTION OF 14TH FLOOR, 'AIG' COST INCL. UNDER FILE #370981(B) LP
Jun 6, 1995 · 145 WELLINGTON ST W - Zoning review91 026945 LTOClosedOct 2, 1991 · 145 WELLINGTON ST W
- Zoning review91 026564 LTOClosedJun 6, 1991 · 145 WELLINGTON ST W
Check before you build
Site-specific exception 900.11.10(772)
Needs a closer look27 site-specific rules and 27 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900Holding provision (H)
Needs a closer lookDevelopment is on hold until the conditions of the holding by-law are met.
Zoning By-law 569-2013
These parts of the exception apply to this lot's address.
- Rule A
On 145 Wellington Street West, if the requirements of By-law 1015-2022 are complied with, a building or structure may be constructed, used or enlarged in compliance with regulations
- Rule B
to (BB) below; (B) Despite regulation 40.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum elevation of 83.125 metres and the elevation of the highest point of the building or structure
- Rule C
Despite Regulation 40.10.40.1(1), residential use portions of the building are permitted to be located on the same storey as non-residential use portions of the building provided such residential use portions do not include a dwelling unit
- Rule D
Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area of all buildings and structures on the lot is 52,750.0 square metres, of which: (i) the required minimum gross floor area for office uses is 14,119 square metres
- Rule E
The provision of dwelling units is subject to the following: (i) A maximum of 512 dwelling units are permitted on the lot; (ii) A minimum of 30 percent of the total number of dwelling units must have two or more bedrooms; (iii) A minimum of 10 percent of the total number of dwelling units must have three or more bedrooms; (iv) Any dwelling units with three or more bedrooms provided to satisfy (E)(iii) above are not included in the provision required by (E)(ii) above; (v) A minimum of 20 of the dwelling units with two or more bedrooms provided to satisfy (E)(ii) above must have a minimum gross floor area of 78 square metres; (vi) A maximum of 2 of the dwelling units with three or more bedrooms provided to satisfy (E)(iii) may have a gross floor area of less than 91 square metres; and (vii) The average gross floor area of dwelling units with three or more bedrooms must be a minimum of 95 square metres.
- Rule F
Despite Regulation 40.10.40.10(1) the permitted maximum height of a building or structure is as shown on Diagram 3 of By-law 1015-2022
- Rule G
Despite Regulations 40.5.40.10(3) to (8), and (F) above, the following equipment and structures may project beyond the permitted maximum height shown on Diagram 3 of By-law 1015-2022: (i) equipment used for the functional operation of the building including electrical, utility, mechanical and ventilation equipment, enclosed stairwells, roof access, maintenance equipment storage, elevator shafts, chimneys, and vents, by a maximum of 6.5 metres; (ii) structures that enclose, screen or cover the equipment, structures and parts of a building listed in (i) above, inclusive of a mechanical penthouse, by a maximum of 6.5 metres, within the area shown as HT 62.0 on Diagram 3 of By-law 1015-2022; (iii) architectural features, parapets, and elements and structures associated with a green roof , by a maximum of 2.5 metres; (iv) building maintenance units and window washing equipment, by a maximum of 6.5 metres; (v) planters, landscaping features, guard rails, and divider screens on a balcony and/or terrace, by a maximum of 3.0 metres; (vi) trellises, pergolas, and unenclosed structures providing safety or wind protection to rooftop amenity space , by a maximum of 4.0 metres; (vii) notwithstanding (G)(iii) above, exterior architectural elements, including but not limited to columns, beams, exoskeleton structures and exoskeleton cladding, structural and non-structural, by a maximum of 22.0 metres within the area shown as HT 62.0 on Diagram 3 of By-law 1015-2022
- Rule H
Article 600.10.10 respecting building setbacks , building separation , separation of main walls , and projections and encroachments into building setbacks and angular planes does not apply
- Rule I
Despite Clause Regulation 40.10.40.70(1), the required minimum building setbacks are as shown in metres on Diagram 3 of By-law 1015-2022
- Rule J
Despite (H) and (I) above, the required minimum building setbacks are as follows within the hatched areas shown on Diagram 4 of By-law 1015-2022: (i) The required minimum building setback from the northern lot line for the portion of a building between the Canadian Geodetic Datum elevation of 83.125 metres to a height of 6.0 metres is 1.6 metres; (ii) No portion of a building or structure between the Canadian Geodetic Datum elevation of 83.125 metres to a height of 61.4 metres may penetrate an angular plane projected from the building setback identified in (J)(ii)(a) to the height identified in (J)(ii)(b) below: (a) a 5.0 metre building setback from the western lot line at the ground level; and (b) a height of 61.0 metres along the western lot line
- Rule K
Despite Regulations 5.10.40.70(1), 40.5.40.60(1) and Clause 40.10.40.60, the following elements may encroach into the required minimum building setbacks and main wall separation distances as follows: (i) decks, porches, and balconies, by a maximum of 2.0 metres; (ii) canopies and awnings, by a maximum of 3.0 metres; (iii) exterior stairs, access ramps and elevating devices, to the extent of the main wall of the storey below; (iv) terraces, guards and guardrails, railings, parapets, privacy and wind screens, landscape planters and terrace platforms to the extent of the main wall of the storey below; (v) cladding added to the exterior surface of the main wall of a building , by a maximum of 0.6 metres; (vi) architectural features, such as a pilaster, decorative column, cornice, sill, belt course, or chimney breast, by a maximum of 2.0 metres; (vii) exterior structural and architectural elements that support the building , including but not limited to columns, beams, exoskeleton structures and exoskeleton cladding, by a maximum of 2.0 metres; (viii) exterior architectural elements in the type and location identified in (G)(vii) above, to the extent of the main wall to which the bottom of such elements are attached; (ix) window projections, including bay windows and box windows, by a maximum of 0.5 metres; (x) eaves, by a maximum of 0.5 metres; (xi) a dormer, by a maximum of 2.0 metres; and (xii) air conditioners, satellite dishes, antennae, vents, and pipes, by a maximum of 3.0 metres
- Rule L
Despite Regulation 230.5.1.10(4), a stacked bicycle parking space may have the following minimum dimensions: (i) length of 1.6 metres; (ii) width of 0.4 metres; and (iii) vertical clearance of 1.2 metres
- Rule M
Despite Regulation 230.5.1.10(4) a bicycle parking space that is not a stacked bicycle parking space may have the following minimum dimensions: (i) length of 1.6 metres; (ii) width of 0.4 metres; and (iii) vertical clearance of 1.9 metres
- Rule N
Despite Regulation 230.5.1.10(10), "short-term" bicycle parking spaces may also be located in a stacked bicycle parking space
- Rule O
Despite Regulations 200.5.10.1(1) and Table 200.5.10.1, parking spaces must be provided on the lot in accordance with the following: (i) a minimum of 34 residential occupant parking spaces ; (ii) a minimum of 5 residential visitor parking spaces ; (iii) no parking spaces are required for non-residential uses; and (iv) parking spaces may be provided within an "automated parking garage", as defined in (S)(iii) below
- Rule P
Despite Regulation 200.5.1.10(2), a maximum of 10 percent of parking spaces provided on the lot may have minimum dimensions of: (i) length of 5.1 metres; (ii) width of 2.4 metres; (iii) vertical clearance of 1.7 metres; and (iv) one side of the parking space may be obstructed as described in Regulation 200.5.1.10(2)(D)without being required to provide additional width for the obstructed sides of the parking space .
- Rule Q
Despite Regulations 200.15.1(1) and 200.15.10(1), a minimum of 2 accessible parking spaces must be provided and maintained in accordance with the following requirements: (i) a minimum width of 3.4 metres; (ii) a minimum length of 5.6 metres; (iii) minimum vertical clearance of 2.1 metres; and (iv) the entire length of an accessible parking space must be adjacent to a 1.5 metre wide accessible barrier free aisle or path on one side of the accessible parking space
- Rule R
Despite Regulation 200.15.1(4), an accessible parking space is required to be no more than 6.0 metres more distant from a passenger elevator that provides access to the first storey of the building and the shortest route from the required entrance to the elevator, than the closest parking space to the elevator
- Rule S
An "automated parking garage" is subject to the following: (i) a minimum of 2 "entry cabins" must be provided; (ii) all "entry cabins" must have driveway access to a street or lane that is direct and unobstructed, excluding a gate, moveable barrier or similar security feature; (iii) for the purpose of this exception, "automated parking garage" means a mechanical system for the purpose of parking and retrieving vehicles without drivers in the vehicle during parking and without the use of ramps or drive aisles , and which may include but is not limited to, a vertical lift and the storage of vehicles on parking pallets and the automated manoeuvring of other vehicles during parking or retrieving operations; and (iv) for the purpose of this exception, "entry cabin" means the component of an "automated parking garage" into which the driver of a vehicle deposits, and from which the driver retrieves, their vehicle
- Rule T
Regulation 200.5.1(3) regarding drive aisle width does not apply to parking spaces located within an "automated parking garage"
- Rule U
Regulations 200.5.1.10(2), (3) and (4), and (P) above, regarding the minimum dimensions and vertical clearance for parking spaces do not apply to parking spaces located within an "automated parking garage"
- Rule V
Regulations 200.5.1.10(5) and (6) regarding requirements for tandem parking spaces do not apply to parking spaces located within an "automated parking garage"
- Rule W
Regulation 200.5.1.10(13) regarding parking space access does not apply to parking spaces located within an "automated parking garage"
- Rule X
Despite Regulation 200.5.1.10(13), a vehicle elevator is not an obstruction to the access of a parking space , subject to the following: (i) a minimum of 2 vehicle queuing spaces must be provided in a stacking aisle on the lot ; and (ii) a vehicle queuing space must have a minimum width of 3.0 metres and minimum length of 6.5 metres
- Rule Y
The requirements of (Q) above regarding accessible parking spaces do not apply if all required parking spaces in (O) are located in an "automated parking garage" having an "entry cabin" with a 1.5 metre wide accessible barrier free aisle or path on one side of the space in which the vehicle is deposited
- Rule Z
Despite Clause 220.5.10.1, loading spaces must be provided and maintained on the lot as follows: (i) one Type "G" loading space ; and (ii) two Type "C" loading space
- Rule AA
Despite Regulations 40.10.40.50(1) and (2), a building with 20 or more dwelling units must provide amenity space on the lot at the following rates: (i) at least 2.7 square metres for each dwelling unit as indoor amenity space ; (ii) at least 1.3 square metres of outdoor amenity space for each dwelling unit , of which 40 square metres must be in a location adjoining or directly accessible to the indoor amenity space ; (iii) no more than 10 percent of the outdoor component may be a green roof ; and (iv) indoor amenity space and outdoor amenity space may be shared by residential and non-residential uses. Prevailing By-laws and Prevailing Sections: (None Apply)
- Older by-law A
On 145 Wellington Street West, if the requirements of By-law 1015-2022 are complied with, a building or structure may be constructed, used or enlarged in compliance with regulations
- Older by-law B
to (BB) below; (B) Despite regulation 40.5.40.10(1) and (2), the height of a building or structure is the distance between the Canadian Geodetic Datum elevation of 83.125 metres and the elevation of the highest point of the building or structure
- Older by-law C
Despite Regulation 40.10.40.1(1), residential use portions of the building are permitted to be located on the same storey as non-residential use portions of the building provided such residential use portions do not include a dwelling unit
- Older by-law D
Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area of all buildings and structures on the lot is 52,750.0 square metres, of which: (i) the required minimum gross floor area for office uses is 14,119 square metres
- Older by-law E
The provision of dwelling units is subject to the following: (i) A maximum of 512 dwelling units are permitted on the lot; (ii) A minimum of 30 percent of the total number of dwelling units must have two or more bedrooms; (iii) A minimum of 10 percent of the total number of dwelling units must have three or more bedrooms; (iv) Any dwelling units with three or more bedrooms provided to satisfy (E)(iii) above are not included in the provision required by (E)(ii) above; (v) A minimum of 20 of the dwelling units with two or more bedrooms provided to satisfy (E)(ii) above must have a minimum gross floor area of 78 square metres; (vi) A maximum of 2 of the dwelling units with three or more bedrooms provided to satisfy (E)(iii) may have a gross floor area of less than 91 square metres; and (vii) The average gross floor area of dwelling units with three or more bedrooms must be a minimum of 95 square metres.
- Older by-law F
Despite Regulation 40.10.40.10(1) the permitted maximum height of a building or structure is as shown on Diagram 3 of By-law 1015-2022
- Older by-law G
Despite Regulations 40.5.40.10(3) to (8), and (F) above, the following equipment and structures may project beyond the permitted maximum height shown on Diagram 3 of By-law 1015-2022: (i) equipment used for the functional operation of the building including electrical, utility, mechanical and ventilation equipment, enclosed stairwells, roof access, maintenance equipment storage, elevator shafts, chimneys, and vents, by a maximum of 6.5 metres; (ii) structures that enclose, screen or cover the equipment, structures and parts of a building listed in (i) above, inclusive of a mechanical penthouse, by a maximum of 6.5 metres, within the area shown as HT 62.0 on Diagram 3 of By-law 1015-2022; (iii) architectural features, parapets, and elements and structures associated with a green roof , by a maximum of 2.5 metres; (iv) building maintenance units and window washing equipment, by a maximum of 6.5 metres; (v) planters, landscaping features, guard rails, and divider screens on a balcony and/or terrace, by a maximum of 3.0 metres; (vi) trellises, pergolas, and unenclosed structures providing safety or wind protection to rooftop amenity space , by a maximum of 4.0 metres; (vii) notwithstanding (G)(iii) above, exterior architectural elements, including but not limited to columns, beams, exoskeleton structures and exoskeleton cladding, structural and non-structural, by a maximum of 22.0 metres within the area shown as HT 62.0 on Diagram 3 of By-law 1015-2022
- Older by-law H
Article 600.10.10 respecting building setbacks , building separation , separation of main walls , and projections and encroachments into building setbacks and angular planes does not apply
- Older by-law I
Despite Clause Regulation 40.10.40.70(1), the required minimum building setbacks are as shown in metres on Diagram 3 of By-law 1015-2022
- Older by-law J
Despite (H) and (I) above, the required minimum building setbacks are as follows within the hatched areas shown on Diagram 4 of By-law 1015-2022: (i) The required minimum building setback from the northern lot line for the portion of a building between the Canadian Geodetic Datum elevation of 83.125 metres to a height of 6.0 metres is 1.6 metres; (ii) No portion of a building or structure between the Canadian Geodetic Datum elevation of 83.125 metres to a height of 61.4 metres may penetrate an angular plane projected from the building setback identified in (J)(ii)(a) to the height identified in (J)(ii)(b) below: (a) a 5.0 metre building setback from the western lot line at the ground level; and (b) a height of 61.0 metres along the western lot line
- Older by-law K
Despite Regulations 5.10.40.70(1), 40.5.40.60(1) and Clause 40.10.40.60, the following elements may encroach into the required minimum building setbacks and main wall separation distances as follows: (i) decks, porches, and balconies, by a maximum of 2.0 metres; (ii) canopies and awnings, by a maximum of 3.0 metres; (iii) exterior stairs, access ramps and elevating devices, to the extent of the main wall of the storey below; (iv) terraces, guards and guardrails, railings, parapets, privacy and wind screens, landscape planters and terrace platforms to the extent of the main wall of the storey below; (v) cladding added to the exterior surface of the main wall of a building , by a maximum of 0.6 metres; (vi) architectural features, such as a pilaster, decorative column, cornice, sill, belt course, or chimney breast, by a maximum of 2.0 metres; (vii) exterior structural and architectural elements that support the building , including but not limited to columns, beams, exoskeleton structures and exoskeleton cladding, by a maximum of 2.0 metres; (viii) exterior architectural elements in the type and location identified in (G)(vii) above, to the extent of the main wall to which the bottom of such elements are attached; (ix) window projections, including bay windows and box windows, by a maximum of 0.5 metres; (x) eaves, by a maximum of 0.5 metres; (xi) a dormer, by a maximum of 2.0 metres; and (xii) air conditioners, satellite dishes, antennae, vents, and pipes, by a maximum of 3.0 metres
- Older by-law L
Despite Regulation 230.5.1.10(4), a stacked bicycle parking space may have the following minimum dimensions: (i) length of 1.6 metres; (ii) width of 0.4 metres; and (iii) vertical clearance of 1.2 metres
- Older by-law M
Despite Regulation 230.5.1.10(4) a bicycle parking space that is not a stacked bicycle parking space may have the following minimum dimensions: (i) length of 1.6 metres; (ii) width of 0.4 metres; and (iii) vertical clearance of 1.9 metres
- Older by-law N
Despite Regulation 230.5.1.10(10), "short-term" bicycle parking spaces may also be located in a stacked bicycle parking space
- Older by-law O
Despite Regulations 200.5.10.1(1) and Table 200.5.10.1, parking spaces must be provided on the lot in accordance with the following: (i) a minimum of 34 residential occupant parking spaces ; (ii) a minimum of 5 residential visitor parking spaces ; (iii) no parking spaces are required for non-residential uses; and (iv) parking spaces may be provided within an "automated parking garage", as defined in (S)(iii) below
- Older by-law P
Despite Regulation 200.5.1.10(2), a maximum of 10 percent of parking spaces provided on the lot may have minimum dimensions of: (i) length of 5.1 metres; (ii) width of 2.4 metres; (iii) vertical clearance of 1.7 metres; and (iv) one side of the parking space may be obstructed as described in Regulation 200.5.1.10(2)(D)without being required to provide additional width for the obstructed sides of the parking space .
- Older by-law Q
Despite Regulations 200.15.1(1) and 200.15.10(1), a minimum of 2 accessible parking spaces must be provided and maintained in accordance with the following requirements: (i) a minimum width of 3.4 metres; (ii) a minimum length of 5.6 metres; (iii) minimum vertical clearance of 2.1 metres; and (iv) the entire length of an accessible parking space must be adjacent to a 1.5 metre wide accessible barrier free aisle or path on one side of the accessible parking space
- Older by-law R
Despite Regulation 200.15.1(4), an accessible parking space is required to be no more than 6.0 metres more distant from a passenger elevator that provides access to the first storey of the building and the shortest route from the required entrance to the elevator, than the closest parking space to the elevator
- Older by-law S
An "automated parking garage" is subject to the following: (i) a minimum of 2 "entry cabins" must be provided; (ii) all "entry cabins" must have driveway access to a street or lane that is direct and unobstructed, excluding a gate, moveable barrier or similar security feature; (iii) for the purpose of this exception, "automated parking garage" means a mechanical system for the purpose of parking and retrieving vehicles without drivers in the vehicle during parking and without the use of ramps or drive aisles , and which may include but is not limited to, a vertical lift and the storage of vehicles on parking pallets and the automated manoeuvring of other vehicles during parking or retrieving operations; and (iv) for the purpose of this exception, "entry cabin" means the component of an "automated parking garage" into which the driver of a vehicle deposits, and from which the driver retrieves, their vehicle
- Older by-law T
Regulation 200.5.1(3) regarding drive aisle width does not apply to parking spaces located within an "automated parking garage"
- Older by-law U
Regulations 200.5.1.10(2), (3) and (4), and (P) above, regarding the minimum dimensions and vertical clearance for parking spaces do not apply to parking spaces located within an "automated parking garage"
- Older by-law V
Regulations 200.5.1.10(5) and (6) regarding requirements for tandem parking spaces do not apply to parking spaces located within an "automated parking garage"
- Older by-law W
Regulation 200.5.1.10(13) regarding parking space access does not apply to parking spaces located within an "automated parking garage"
- Older by-law X
Despite Regulation 200.5.1.10(13), a vehicle elevator is not an obstruction to the access of a parking space , subject to the following: (i) a minimum of 2 vehicle queuing spaces must be provided in a stacking aisle on the lot ; and (ii) a vehicle queuing space must have a minimum width of 3.0 metres and minimum length of 6.5 metres
- Older by-law Y
The requirements of (Q) above regarding accessible parking spaces do not apply if all required parking spaces in (O) are located in an "automated parking garage" having an "entry cabin" with a 1.5 metre wide accessible barrier free aisle or path on one side of the space in which the vehicle is deposited
- Older by-law Z
Despite Clause 220.5.10.1, loading spaces must be provided and maintained on the lot as follows: (i) one Type "G" loading space ; and (ii) two Type "C" loading space
- Older by-law AA
Despite Regulations 40.10.40.50(1) and (2), a building with 20 or more dwelling units must provide amenity space on the lot at the following rates: (i) at least 2.7 square metres for each dwelling unit as indoor amenity space ; (ii) at least 1.3 square metres of outdoor amenity space for each dwelling unit , of which 40 square metres must be in a location adjoining or directly accessible to the indoor amenity space ; (iii) no more than 10 percent of the outdoor component may be a green roof ; and (iv) indoor amenity space and outdoor amenity space may be shared by residential and non-residential uses. Prevailing By-laws and Prevailing Sections: (None Apply)
Lot facts
- Area
- 1,482 m²
- Frontage
- 30.5 m
- Depth
- 48.8 m
- Street
- Emily St
- Corner lot
- Yes, also on Wellington St W48.8 m along it
- Public lane
- Ln W University S Wellington, 44.3 m along it
- House footprint
- 1,288 m²
- Back yard
- 2.7 mhouse to rear lot line
- Side yards
- 0.3 m and 0.3 mhouse to side lot lines
- Buildings on the lot
- 2house, garage, sheds
- Max height
- 76 m
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
- Major Transit Station Area: King. The lot is inside the King Major Transit Station Area approved by the Province (Site and Area Specific Policy 606). Source
- Downtown Plan Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
- Zone (H) CR 12.0 (c8.0; r11.7) SS1 (x772) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
- 1 City tree in front of this lot. The City's street tree inventory lists 1 tree at this address: kentucky coffeetree (8 cm). Diameter is the trunk at breast height. Source
Around this lot
- Minor variances approved
- 100%13 of 13 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 0
- Multiplex permits
- 2
- Development applications
- 11
Within 300 m, last 10 years. 2 suite and multiplex permits: no more than at most Toronto houses (median 3). 13 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To alter the existing 26-storey non-residential building (office use) by constructing a one-storey ground floor addition (patio enclosure for an eating establishment), along the east side of the building.
121 KING ST W · Jul 8, 2026 · 254 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 105-2022 (OLT)) for a 47-storey mixed-use building (containing 432 residential dwelling units, retail use on the ground level, and office use on second, third and fourth levels), by reducing the required number of vehicular parking spaces for the residents of this building.
263 ADELAIDE ST W · Jan 28, 2026 · 421 m away - Minor varianceApproved
To alter the existing 17-storey mixed-use building by constructing a side (east) one-storey addition (patio enclosure for the existing outdoor dining area of Local Public Eatery), abutting Adelaide Street West, and York Street.
141 ADELAIDE ST W · Jan 14, 2026 · 339 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 1219-2023(OLT) for a 61-storey mixed-use building, by increasing the building height to 67-storeys (223 m), the maximum gross floor area (residential and overall), a wind damper enclosure projection beyond the maximum building height, as well as to reduce the minimum non-residential gross floor area (remove the office uses), and reduce the number of loading spaces. There will be a total of 1,003 residential dwelling units on this lot (including 46 affordable units), subject to review under the related Site Plan Control Application (File 20 22 119164 STE 10 SA).
100 SIMCOE ST · Sep 10, 2025 · 287 m away - Minor varianceApproved
To alter the existing 27-storey mixed-use building by reconstructing the commercial space on the ground floor to accommodate a larger frontage along University Avenue for the financial institution use (Scotiabank), and to accommodate a second eating establishment use (fronting King Street West). The total gross floor area of the financial institution use will be maintained (modifying the layout of the frontage to University Avenue and King Street West). The existing commercial office space (fronting University Avenue) will be removed.
145 KING ST W · Feb 12, 2025 · 190 m away
Latest activity nearby
- Minor variancePending
To alter the existing 42-storey mixed-use building by constructing a side (west) one-storey addition (to enclose the existing patio with two new side (west) principal entrances for the existing eating establishment), abutting Wellington Street West.
155 WELLINGTON ST W · Nov 25, 2026 · 59 m away - Building permit
Proposal to upgrade sprinkler systems on 5th floor.
230 FRONT ST W · Nov 25, 2026 · 160 m away - Building permit
Proposed interior demolition back to base, including mechanical and sprinkler work.
130 KING ST W · Nov 24, 2026 · 276 m away - Building permit
Proposed Interior build-out and alterations to an existing offices.
150 KING ST W · Nov 24, 2026 · 261 m away - Building permit
Rev 01 - Addition of the sink sewage sump pump in the meeting lounge 1713interior tenant fit-out including demolition, floor preparation, millwork installations, new doors and glazing, drywall partitions and ceilings, flooring and painting, appliance installation, and associated mechanical and electrical work
121 KING ST W · Nov 24, 2026 · 254 m away - Building permit
Proposal for interior alterations in existing vacant retail unit for new coffee shop.
154 UNIVERSITY AVE · Nov 23, 2026 · 276 m away - Building permit
Proposal for interior alterations on level 1 mezzanine of existing hotel. Work to include demolition of existing millwork, glass partitions of wine storage room, and indicated sections of the ceiling. Construction of new partitions, floor finishes, ceilings, millwork, and light fixtures.
181 WELLINGTON ST W · Nov 23, 2026 · 169 m away - Building permit
17th Floor: -Remove temporary upright sprinklers.-Relocate up to two (2) fire hose cabinets. -Supply and install up to one (1) fire hose cabinet, c/w SV. Wiring and programming by others.-Supply and install up to one hundred fifty-seven (157) white concealed pendent sprinklers.-Supply and install up to forty-two (42) upright sprinklers.18th Floor:-Remove temporary upright sprinklers.-Relocate up to two (2) fire hose cabinets.-Supply and install up to one (1) fire hose cabinet, c/w SV. Wiring and programming by others.-Supply and install up to one hundred fifty-four (154) white concealed pendent sprinklers.-Supply and install up to forty-three (43) upright sprinklers.19th Floor:-Remove temporary upright sprinklers.-Relocate up to three (3) fire hose cabinets.-Supply and install up to one (1) fire hose cabinet, c/w SV. Wiring and programming by others.-Supply and install up to one hundred twenty (120) white concealed pendent sprinklers.-Supply and install up to forty-four (44) upright sprinklers.
95 WELLINGTON ST W · Nov 23, 2026 · 240 m away - Building permit
1 Ground Sign + 1 Overhanging Structure Sign ** MARIO FRESH FOOD/REXALL/HEALTHONE/FITLIFE**
200 WELLINGTON ST W · Nov 23, 2026 · 228 m away - Building permit
1 Ground Sign + 1 Overhanging Structure Sign ** MARIO FRESH FOOD/REXALL/HEALTHONE/FITLIFE **
200 WELLINGTON ST W · Nov 23, 2026 · 228 m away
Neighbourhood: Yonge-Bay Corridor
About the area around the lot, not the lot itself.
- Nearest station
- St. Andrew Station3 min walk
- Nearest TTC stop
- St Andrew Station - Southbound Platform2 min walk
- Nearest cycling route
- Simcoe StCycle Track, 1 min walk
- Nearest traffic count
- 9,205 vehicles in 14 hSimcoe St / Wellington St W, 40 m away, Jul 17, 2024
- Serious collisions within 500 m
- 92021–2026, killed or seriously injured: 1 fatal, 4 with pedestrians, 5 with cyclists
- Parks
- Simcoe Park3 min walk
- Olympic Park5 min walk
- Isabella Valancy Crawford Park6 min walk
Schools within 1 km
- OCAD UNIVERSITY - INCLUSIVE DESIGN INSTITUTE University 12 min walk
- OCAD UNIVERSITY - STUDENT CENTRE University 13 min walk
- VICTORIA STREET LINC English Public 13 min walk
- OCAD UNIVERSITY - ABOVEGROUND ART SUPPLIES University 14 min walk
- KEYSTONE INTERNATIONAL SCHOOLS Private 14 min walk
- OCAD UNIVERSITY - MAIN BUILDING 416 977-6000 University 15 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Yonge-Bay Corridor | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $68,500 | $84,500 |
| Households that own their home | 32% | 54% |
| Population (2021) | 12,645 | 16,813 |
| Homes built in 1960 or before | 2% | 29% |
| Homes needing major repairs | 2% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Yonge-Bay Corridor | City median |
|---|---|---|
| Assault | 3361.1 | 636.3 |
| Robbery | 300.1 | 69.5 |
| Homicide | 12 | 5.3 |
| Shootings | 12 | 10.5 |
| Auto theft | 162.1 | 192.6 |
| Theft over $5,000 | 210.1 | 46.1 |
| Break and enter | 552.2 | 172.8 |
| Theft from vehicles | 402.1 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.