Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
1 by-law investigation closed in the last two years
Good to knowClosed files (Property Standards): 26 152592 PRS 00 IR (Property Standards, 2026).
What it means. Someone raised an issue here and the City closed the file. Ask the seller what it was about.
City of Toronto, Toronto Building orders and Municipal Licensing and Standards investigationsWork or applications in progress
Good to knowRecent records on this lot: 21 205938 STE 09 SA (Site Plan Approval for a mixed-use building comprised of two towers having heights of 3..., 2021).
What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.
How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details
City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications3 Committee of Adjustment files on this lot
Good to know3 approved. B0054/25TEY (To obtain consent to sever the property into two mixed-use lots and to create new easem..., 2025); A0222/25TEY (To permit the construction of the Bloor Lansdowne SmartTrack GO Station, which consists..., 2025); A0760/24TEY (To alter the development standards (as approved under Site Specific Zoning By-law 589-2..., 2024).
What it means. Approved variances and consents stay with the property, including any conditions in the decision. They allow what was approved, not more.
How to confirm. Decisions are in the Application Information Centre; older files are available from the Committee of Adjustment office. Details
City of Toronto, Committee of Adjustment applications (2001 onwards)8 development applications open within 300 m
Good to know8 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 33 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
22 records on file: more than at 100% of Toronto houses (median 0).
- By-law investigation26 169201 GRA 00 IRClosed
Graffiti
May 28, 2026 · 1319 BLOOR ST W - By-law investigation26 152592 PRS 00 IRClosed
Property Standards
Apr 30, 2026 · 1319 BLOOR ST W - Consent (lot split)B0054/25TEYApproved
To obtain consent to sever the property into two mixed-use lots and to create new easements/rights-of-way.
Nov 26, 2025 · 1319 BLOOR ST W - By-law investigation25 230090 WST 00 IRClosed
Waste
Sep 24, 2025 · 1319 BLOOR ST W - By-law investigation25 189830 WST 00 IRClosed
Waste
Jul 7, 2025 · 1319 BLOOR ST W - By-law investigation25 181729 LGW 00 IRClosed
Long Grass and Weeds
Jun 23, 2025 · 1319 BLOOR ST W - Minor varianceA0222/25TEYApproved
To permit the construction of the Bloor Lansdowne SmartTrack GO Station, which consists of the main entrance building (municipally known as 1325 Bloor Street West), and a maintenance building with bicycle parking, and a partially enclosed waste and recycling storage area (municipally known as 17 Dora Avenue). The station also includes a West Access Building as well as other station elements (including the platforms, waiting enclosures, a pedestrian tunnel to access the westerly platform, stairs and elevators) will be located within the rail corridor and not part of the subject lands (municipally known as 1325 Bloor Street West and 17 Dora Avenue). The application is to also modify Schedule A, as cited under Site Specific Zoning By-law 589-2022, to exempt transportation uses from Section 37 obligations.
May 7, 2025 · 1319 BLOOR ST W - Minor varianceA0760/24TEYApproved
To alter the development standards (as approved under Site Specific Zoning By-law 589-2022) for a 31-storey and 35-storey mixed-use building, by permitting an increase in building height and total gross floor area, and to modify the building envelope (setbacks and step-backs). There will be a total of 1,100 residential dwelling units on this lot.
Nov 27, 2024 · 1319 BLOOR ST W
Show 14 older records
- Zoning review24 216386 PSPClosedNov 21, 2024 · 1319 BLOOR ST W
- Development application24 216386 STE 09 SAClosed
This site plan control application is for the propossed Bloor Lansdowne Smart Track GO Station, which consists of the main station building, platforms, and Maintenance Building located at the south end of the platforms at Dora Avenue. Cross-Reference 1319 Bloor Street West - Site Plan Control Application 21 205938 STE 09 SA
Sep 23, 2024 · 1319 BLOOR ST W · City file - Zoning review22 141709 ZAPClosedMay 3, 2022 · 1319 BLOOR ST W
- Zoning review22 141707 ZAPCancelledMay 3, 2022 · 1319 BLOOR ST W
- Zoning review20 230587 PRZClosedJan 11, 2022 · 1319 BLOOR ST W
- Development application21 205938 STE 09 SAUnder Review
Site Plan Approval for a mixed-use building comprised of two towers having heights of 31 and 33-storeys atop a podium ranging in height between 4 and 7-storeys. The proposed residential gross floor area is 56,876.46 square metres, and the proposed non-residential gross floor area is 1212.42 square metres. A total of 634 residential dwelling units are proposed.
Aug 30, 2021 · 1319 BLOOR ST W · City file - Development application20 230587 STE 09 OZClosed
Proposal for the development of 31-storey and 33-storey towers atop a podium which varies in height from 4-7storeys. The proposed non-residential gross floor area is 1200 square metres, and the proposed residential gross floor area is 59238 square metres.
Dec 18, 2020 · 1319 BLOOR ST W · City file - Building permit19 160496Cancelled
Proposal for an exterior un-enclosed canopy at rear loading area in existing multiple unit building.
Jun 18, 2019 · 1319 BLOOR ST W - Zoning review19 139860 ZZCClosedApr 13, 2019 · 1319 BLOOR ST W
- Building permit18 270802Closed
Proposal to erect and display one illuminated ground sign, displaying static copy, located on the north frontage of the property (perpendicular to Bloor Street West). The proposed sign contains two sign faces, each sign face measuring 3.05 metres vertically by 3.05 metres horizontally at a height of 6.1 metres above grade.***VALUE VILLAGE***
Mar 1, 2019 · 1319 BLOOR ST W - Building permit15 190958Closed
In conjunction with Value Village location, proposal to erect and display one illuminated overhanging structure sign displaying static copy on a canopy located along the easterly property frontage, erected in a northerly direction. The proposed sign is to measure 1.77 metres horizontally by 0.53 metres vertically, at a height of 4.72 metres. **VALUE VILLAGE**
Jul 30, 2015 · 1319 BLOOR ST W - Building permit15 162932Closed
Permit to construct new exterior conopy over customer drop-off area at existing Value Village.
Jul 22, 2015 · 1319 BLOOR ST W - Building permit13 236533Cancelled
To erect and display one illuminated wall sign on the front elevation of single storey building, in conjunction with a thrift shop.**Value Village**
Sep 24, 2013 · 1319 BLOOR ST W - Zoning review94 025136 LTOClosedJul 4, 1994 · 1319 BLOOR ST W
Check before you build
Site-specific exception 900.11.10(1750)
Needs a closer look23 site-specific rules and 23 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
On 1319 Bloor Street West, as shown on Diagram 1 of By-law 589-2022 if the requirements of Section 11 and Schedule A of By-law 589-2022 are complied with, a building or structure may be constructed, used or enlarged in compliance with Regulations
- Rule B
to (W) below; (B) Despite 40.10.40.1(1), residential use portions of the building are permitted to be located on the same storey as non-residential use portions of the building
- Rule C
Despite Regulation 40.5.40.10(1) and 40.5.40.10(2), the height of a building or structure is the distance between the Canadian Geodetic Datum elevation of 113.0 metres and the elevation of the highest point of the building or structure
- Rule D
Despite Regulation 40.10.40.10(2), the permitted maximum height of a building or structure is the number, following the letters "HT" in metres as shown on Diagram 6 of By-law 589-2022
- Rule E
Despite (D) above and Regulation 40.10.40.10(2), there is no maximum height for a transportation use located within the area labelled as "Metrolinx conveyance" on Diagram 6 of By-law 589-2022
- Rule F
Despite (D) above and Regulations 40.5.40.10(4), 40.5.40.10(5), and 40.5.40.10(6), the following equipment and structures may project beyond the permitted maximum height of a building , in accordance with the following: (i) structures on any roof used exclusively for the storage of mechanical, electrical, or other equipment used for the functional operation of the building may project above the height limits to a maximum of 6.5 metres; (ii) structures on any roof used for elevators, elevator overruns, window washing equipment, and related structural elements may project above the height limits to a maximum of 8.0 metres; (iii) structures on any roof used for outdoor amenity space or open air recreation may project above the height limits to a maximum of 3.5 metres; (iv) balcony dividers, privacy screens, parapets, architectural elements, landscape features, light fixtures, acoustical and privacy screens, sound barriers, and wind mitigation equipment may project above the height limits to a maximum of 2.0 metres; and (v) crash walls and structures associated with rail safety mitigation
- Rule G
Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area is 61,500 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 60,000 square metres; (ii) the permitted maximum gross floor area for non-residential uses is 1,500 square metres; (iii) a minimum of 200 square metres of the permitted non-residential gross floor area must be provided for a transportation use ; and (iv) a minimum of 464 square metres of the permitted non-residential gross floor area must be provided for a community centre
- Rule H
a minimum of 20 percent of the total dwelling units on the lot must contain a minimum of two-bedroom dwelling units
- Rule I
a minimum of 10 percent of the total dwelling units on the lot must contain a minimum of three-bedroom dwelling units
- Rule J
The maximum permitted floor area of any storey above a height of 45.0 metres, measured from the Canadian Geodetic Elevation of 113.0, is 850 square metres
- Rule K
For the purposes of this exception: (i) the floor area of a storey located above a height of 45.0 metres is measured from the exterior of the main walls
- Rule L
Despite Regulations 40.10.40.70(2), and 40.10.40.80(2), the required minimum building setbacks and the required minimum separation of main walls are as shown, in metres, on Diagram 6 of By-law 589-2022
- Rule M
Despite (L) above and Regulations 40.10.40.70(2) and 40.10.40.80(2), there are no minimum building setbacks or minimum separation of main walls for a transportation use located within the area labelled as "Metrolinx conveyance" on Diagram 6 of By-law 589-2022
- Rule N
Despite (L) above, the required minimum building setback for the ground floor is: (i) 7.0 metres from Bloor Street West, except for the portion of a main wall of a building containing a transportation use ; and (ii) 7.5 metres, exclusive of structural support columns, from St. Helen's Avenue for the first 28.5 metres south of Bloor Street West
- Rule O
Despite (L) above and Regulations 40.10.40.60(1), 40.10.40.60(2), 40.10.40.60(3), 40.10.40.60(4), 40.10.40.60(5), 40.10.40.60(6), 40.10.40.60(7), 40.10.40.60(8), and 40.10.40.60(9), the following elements may encroach into the required minimum building setbacks and minimum separation distances as follows: (i) cornices, window sills, eaves, balustrades, ornamental or architectural features, to a maximum extent of 0.75 metres; (ii) balconies, to a maximum extent of 3.5 metres; (iii) canopies along Bloor Street West to a maximum extent of 8.5 metres; (iv) canopies, other than those in (iii) above, and awnings, including structural support structures, to a maximum extent of 4.0 metres; (v) railings, planters, stairs, light fixtures, bollards, safety railings, guards, guardrails, wheelchair ramps, bicycle parking facilities, landscape features, architectural features, and art installations to a maximum extent of 2.0 metres; and (vi) crash walls and structures associated with rail safety mitigation
- Rule P
Despite Regulations 200.5.10.1(1) and 200.5.10.1(2) and Table 200.5.10.1, parking spaces must be provided in accordance with the following: (i) Resident requirement for a dwelling unit in an apartment building or mixed use building : (a) a minimum of 0 parking spaces for each dwelling unit ; (b) a maximum of 0.3 parking spaces for each bachelor dwelling unit up to 45 square metres; (c) a maximum of 1.0 parking space for each bachelor dwelling unit greater than 45 square metres; (d) a maximum of 0.5 parking spaces for each one-bedroom dwelling unit ; (e) a maximum of 0.8 parking spaces for each two-bedroom dwelling unit ; and (f) a maximum of 1.0 parking space for each three-bedroom dwelling unit ; (ii) Visitor requirement for a dwelling unit in an apartment building or mixed use building : (a) a minimum of 2.0 parking spaces plus 0.01 parking spaces per dwelling unit ; (b) a maximum of 1.0 parking space per dwelling unit for the first five dwelling units ; and (c) a maximum of 0.1 parking spaces per dwelling unit for the sixth and subsequent dwelling units ; (iii) 0 parking spaces are required for non-residential uses; and (iv) A minimum of three parking spaces for "car-share"
- Rule Q
For the purposes of this exception: (i) "car-share" means the practice whereby a number of people share the use of one or more motor vehicles and such 'car-share' motor vehicles are made available to at least the occupants of the building or short term rental, including hourly rental; (ii) "car-share parking space" means a parking space exclusively reserved and signed for a vehicle used only for 'car-share' purposes
- Rule R
Despite Regulations 200.15.1(1) and 200.15.10(1) and By-law 579-2017, ten accessible parking spaces must be provided in accordance with the following: (i) An accessible parking space must have the following minimum dimensions: (a) length of 5.6 metres; (b) width of 3.4 metres; and (c) vertical clearance of 2.1 metres; (ii) The entire length of an accessible parking space must be adjacent to a 1.5 metre wide accessible barrier free aisle or path; (iii) Accessible parking spaces are required to be within 30 metres of a barrier free entrance to the building and passenger elevator that provides access to the first storey of the building
- Rule S
Despite Clause 220.5.10.1, a minimum of one Type "G" loading space and one Type "C" loading space must be provided on the lot
- Rule T
Regulations 230.5.1.10(9) and 230.40.1.20(2), in relation to the location of "long-term" and "short-term" bicycle parking spaces , do not apply
- Rule U
Despite Regulation 230.5.1.10(10), both "long-term" and "short-term" bicycle parking spaces may be located in a stacked bicycle parking space
- Rule V
An opening in the main wall of the building abutting Bloor Street West is required and must provide unobstructed pedestrian access to the privately owned publically accessible open space in accordance with the following: (i) the required opening in the main wall must have a minimum width of 8.6 metres; (ii) the required opening under (i) above must have a minimum vertical clearance of 10.0 metres, measured from the finished grade to the underside of the floor above, excluding canopy and other architectural and decorative elements, including light fixtures; and (iii) the south end of the required opening abutting Bloor Street West and providing unobstructed pedestrian access to the privately owned publically accessible open space must have a vertical clearance of 8.0 metres, measured from the finished grade to the underside of the floor above, excluding canopy and other architectural and decorative elements, including light fixtures
- Rule W
A multi-use path with a minimum width of 4.75 metres is required along the southern lot line , as shown on Diagram 6 of By-law 589-2022. Prevailing By-laws and Prevailing Sections: (None Apply)
- Older by-law A
On 1319 Bloor Street West, as shown on Diagram 1 of By-law 589-2022 if the requirements of Section 11 and Schedule A of By-law 589-2022 are complied with, a building or structure may be constructed, used or enlarged in compliance with Regulations
- Older by-law B
to (W) below; (B) Despite 40.10.40.1(1), residential use portions of the building are permitted to be located on the same storey as non-residential use portions of the building
- Older by-law C
Despite Regulation 40.5.40.10(1) and 40.5.40.10(2), the height of a building or structure is the distance between the Canadian Geodetic Datum elevation of 113.0 metres and the elevation of the highest point of the building or structure
- Older by-law D
Despite Regulation 40.10.40.10(2), the permitted maximum height of a building or structure is the number, following the letters "HT" in metres as shown on Diagram 6 of By-law 589-2022
- Older by-law E
Despite (D) above and Regulation 40.10.40.10(2), there is no maximum height for a transportation use located within the area labelled as "Metrolinx conveyance" on Diagram 6 of By-law 589-2022
- Older by-law F
Despite (D) above and Regulations 40.5.40.10(4), 40.5.40.10(5), and 40.5.40.10(6), the following equipment and structures may project beyond the permitted maximum height of a building , in accordance with the following: (i) structures on any roof used exclusively for the storage of mechanical, electrical, or other equipment used for the functional operation of the building may project above the height limits to a maximum of 6.5 metres; (ii) structures on any roof used for elevators, elevator overruns, window washing equipment, and related structural elements may project above the height limits to a maximum of 8.0 metres; (iii) structures on any roof used for outdoor amenity space or open air recreation may project above the height limits to a maximum of 3.5 metres; (iv) balcony dividers, privacy screens, parapets, architectural elements, landscape features, light fixtures, acoustical and privacy screens, sound barriers, and wind mitigation equipment may project above the height limits to a maximum of 2.0 metres; and (v) crash walls and structures associated with rail safety mitigation
- Older by-law G
Despite Regulation 40.10.40.40(1), the permitted maximum gross floor area is 61,500 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 60,000 square metres; (ii) the permitted maximum gross floor area for non-residential uses is 1,500 square metres; (iii) a minimum of 200 square metres of the permitted non-residential gross floor area must be provided for a transportation use ; and (iv) a minimum of 464 square metres of the permitted non-residential gross floor area must be provided for a community centre
- Older by-law H
a minimum of 20 percent of the total dwelling units on the lot must contain a minimum of two-bedroom dwelling units
- Older by-law I
a minimum of 10 percent of the total dwelling units on the lot must contain a minimum of three-bedroom dwelling units
- Older by-law J
The maximum permitted floor area of any storey above a height of 45.0 metres, measured from the Canadian Geodetic Elevation of 113.0, is 850 square metres
- Older by-law K
For the purposes of this exception: (i) the floor area of a storey located above a height of 45.0 metres is measured from the exterior of the main walls
- Older by-law L
Despite Regulations 40.10.40.70(2), and 40.10.40.80(2), the required minimum building setbacks and the required minimum separation of main walls are as shown, in metres, on Diagram 6 of By-law 589-2022
- Older by-law M
Despite (L) above and Regulations 40.10.40.70(2) and 40.10.40.80(2), there are no minimum building setbacks or minimum separation of main walls for a transportation use located within the area labelled as "Metrolinx conveyance" on Diagram 6 of By-law 589-2022
- Older by-law N
Despite (L) above, the required minimum building setback for the ground floor is: (i) 7.0 metres from Bloor Street West, except for the portion of a main wall of a building containing a transportation use ; and (ii) 7.5 metres, exclusive of structural support columns, from St. Helen's Avenue for the first 28.5 metres south of Bloor Street West
- Older by-law O
Despite (L) above and Regulations 40.10.40.60(1), 40.10.40.60(2), 40.10.40.60(3), 40.10.40.60(4), 40.10.40.60(5), 40.10.40.60(6), 40.10.40.60(7), 40.10.40.60(8), and 40.10.40.60(9), the following elements may encroach into the required minimum building setbacks and minimum separation distances as follows: (i) cornices, window sills, eaves, balustrades, ornamental or architectural features, to a maximum extent of 0.75 metres; (ii) balconies, to a maximum extent of 3.5 metres; (iii) canopies along Bloor Street West to a maximum extent of 8.5 metres; (iv) canopies, other than those in (iii) above, and awnings, including structural support structures, to a maximum extent of 4.0 metres; (v) railings, planters, stairs, light fixtures, bollards, safety railings, guards, guardrails, wheelchair ramps, bicycle parking facilities, landscape features, architectural features, and art installations to a maximum extent of 2.0 metres; and (vi) crash walls and structures associated with rail safety mitigation
- Older by-law P
Despite Regulations 200.5.10.1(1) and 200.5.10.1(2) and Table 200.5.10.1, parking spaces must be provided in accordance with the following: (i) Resident requirement for a dwelling unit in an apartment building or mixed use building : (a) a minimum of 0 parking spaces for each dwelling unit ; (b) a maximum of 0.3 parking spaces for each bachelor dwelling unit up to 45 square metres; (c) a maximum of 1.0 parking space for each bachelor dwelling unit greater than 45 square metres; (d) a maximum of 0.5 parking spaces for each one-bedroom dwelling unit ; (e) a maximum of 0.8 parking spaces for each two-bedroom dwelling unit ; and (f) a maximum of 1.0 parking space for each three-bedroom dwelling unit ; (ii) Visitor requirement for a dwelling unit in an apartment building or mixed use building : (a) a minimum of 2.0 parking spaces plus 0.01 parking spaces per dwelling unit ; (b) a maximum of 1.0 parking space per dwelling unit for the first five dwelling units ; and (c) a maximum of 0.1 parking spaces per dwelling unit for the sixth and subsequent dwelling units ; (iii) 0 parking spaces are required for non-residential uses; and (iv) A minimum of three parking spaces for "car-share"
- Older by-law Q
For the purposes of this exception: (i) "car-share" means the practice whereby a number of people share the use of one or more motor vehicles and such 'car-share' motor vehicles are made available to at least the occupants of the building or short term rental, including hourly rental; (ii) "car-share parking space" means a parking space exclusively reserved and signed for a vehicle used only for 'car-share' purposes
- Older by-law R
Despite Regulations 200.15.1(1) and 200.15.10(1) and By-law 579-2017, ten accessible parking spaces must be provided in accordance with the following: (i) An accessible parking space must have the following minimum dimensions: (a) length of 5.6 metres; (b) width of 3.4 metres; and (c) vertical clearance of 2.1 metres; (ii) The entire length of an accessible parking space must be adjacent to a 1.5 metre wide accessible barrier free aisle or path; (iii) Accessible parking spaces are required to be within 30 metres of a barrier free entrance to the building and passenger elevator that provides access to the first storey of the building
- Older by-law S
Despite Clause 220.5.10.1, a minimum of one Type "G" loading space and one Type "C" loading space must be provided on the lot
- Older by-law T
Regulations 230.5.1.10(9) and 230.40.1.20(2), in relation to the location of "long-term" and "short-term" bicycle parking spaces , do not apply
- Older by-law U
Despite Regulation 230.5.1.10(10), both "long-term" and "short-term" bicycle parking spaces may be located in a stacked bicycle parking space
- Older by-law V
An opening in the main wall of the building abutting Bloor Street West is required and must provide unobstructed pedestrian access to the privately owned publically accessible open space in accordance with the following: (i) the required opening in the main wall must have a minimum width of 8.6 metres; (ii) the required opening under (i) above must have a minimum vertical clearance of 10.0 metres, measured from the finished grade to the underside of the floor above, excluding canopy and other architectural and decorative elements, including light fixtures; and (iii) the south end of the required opening abutting Bloor Street West and providing unobstructed pedestrian access to the privately owned publically accessible open space must have a vertical clearance of 8.0 metres, measured from the finished grade to the underside of the floor above, excluding canopy and other architectural and decorative elements, including light fixtures
- Older by-law W
A multi-use path with a minimum width of 4.75 metres is required along the southern lot line , as shown on Diagram 6 of By-law 589-2022. Prevailing By-laws and Prevailing Sections: (None Apply)
Lot facts
- Area
- 8,724 m²
- Frontage
- 77.3 m
- Depth
- 113.7 m
- Street
- Bloor St W
- Corner lot
- Yes, also on St Helen's Ave113.7 m along it
- Public lane
- None
- House footprint
- 1,435 m²roof up to 9.7 m
- Back yard
- 10.1 mhouse to rear lot line
- Side yards
- 4.2 m and 17.2 mhouse to side lot lines
- Buildings on the lot
- 3house, garage, sheds
- Max height
- 30 m
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
- Major Transit Station Area: Lansdowne. The lot is inside the Lansdowne Major Transit Station Area approved by the Province (Site and Area Specific Policy 657). Source
- Zone CR 4.0 (c1.0; r3.5) SS2 (x1750) (Commercial Residential). Chapter 40, section 40.10 of the by-law. Source
- 1 City tree in front of this lot. The City's street tree inventory lists 1 tree at this address: ash, green (47 cm). Diameter is the trunk at breast height. Source
Around this lot
- Minor variances approved
- 97%34 of 35 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 1
- Multiplex permits
- 11
- Development applications
- 18
Within 300 m, last 10 years. 12 suite and multiplex permits: more than at 78% of Toronto houses (median 3). 35 variance decisions: more than at 69% of Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To permit the construction of the Bloor Lansdowne SmartTrack GO Station, which consists of the main entrance building (municipally known as 1325 Bloor Street West), and a maintenance building with bicycle parking, and a partially enclosed waste and recycling storage area (municipally known as 17 Dora Avenue). The station also includes a West Access Building as well as other station elements (including the platforms, waiting enclosures, a pedestrian tunnel to access the westerly platform, stairs and elevators) will be located within the rail corridor and not part of the subject lands (municipally known as 1325 Bloor Street West and 17 Dora Avenue). The application is to also modify Schedule A, as cited under Site Specific Zoning By-law 589-2022, to exempt transportation uses from Section 37 obligations.
1319 BLOOR ST W · May 7, 2025 · 11 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 589-2022) for a 31-storey and 35-storey mixed-use building, by permitting an increase in building height and total gross floor area, and to modify the building envelope (setbacks and step-backs). There will be a total of 1,100 residential dwelling units on this lot.
1319 BLOOR ST W · Nov 27, 2024 · 11 m away - Minor varianceApproved
To alter the development standards for a new rental building (approved under Site Specific Zoning By-law 182-2022, as amended by City Wide By-law 569-2013, and Minor Variance Decision A0892/22TEY) by increasing the building height from 11 to 16 storeys, reducing the ground floor height, increasing the residential density, increasing the number of residential units from 128 to 211 units, amending the building setbacks/stepbacks and reducing the loading space provisions on site. The existing vacant two-story building (previously used as a place of worship) will be demolished.
72 PERTH AVE · Apr 24, 2024 · 365 m away - Minor varianceApproved
To alter the development standards, as approved under Site Specific Zoning By-law 943-2015 (OMB), which include adding an additional storey, changes to the overall height, setbacks, and parking standards, for the approved 16-storey mixed-use building (currently under construction).
181 STERLING RD · Nov 8, 2023 · 256 m away - Minor varianceApproved
To alter the development standards (as approved under Site Specific Zoning By-law 927-2022 for an 18-storey mixed-use building with a 6-storey podium, and one level of underground parking) by constructing two additional storeys, increasing the overall building height and residential gross floor area.
1423 BLOOR ST W · Sep 20, 2023 · 306 m away
Latest activity nearby
- Minor variancePending
To alter the existing four-storey mixed-use building by constructing two mechanical penthouse enclosures (including rooftop access), and a partially covered rooftop terrace with a trellis (above the fourth storey). The ground level and second level will contain one commercial unit (art gallery and event space). The third level will contain a multi-functional commercial space for youth programming, as well as amenity space for building residents (including counselling rooms, a gym, a break room, and an open-concept collaboration space). There will be a total of eight residential dwelling units located on the fourth level for youth transitioning from the Ontario Child Protection Services foster care system.
1286 BLOOR ST W · Nov 25, 2026 · 241 m away - Zoning review
Application On Hold
463 ST CLARENS AVE · Nov 23, 2026 · 288 m away - Zoning review
Not Started
1280 BLOOR ST W · Oct 30, 2026 · 274 m away - Building permit
Proposed interior alterations for tenant fit-out to levels 5, 6, 7 with ancillary and support functions on levels P1, Level 1 mechanical penthouse and roof level.
77 WADE AVE · Oct 8, 2026 · 275 m away - Building permit
Revision No.1: Revise permit as issued 25 248911 BLD 00 SR to incorporate a basement secondary suite Proposal to construct a third storey addition above an existing single family dwelling, with a new front covered porch, a rear deck, a front basement walkout, basement underpinning, and interior alterations. Also, to demolish the existing detached garage and propose two parking spots in the rear yard.
627 LANSDOWNE AVE · Oct 8, 2026 · 159 m away - Zoning review
Application On Hold
1293 BLOOR ST W · Oct 6, 2026 · 136 m away - Zoning review
Cancelled
1280 BLOOR ST W · Oct 5, 2026 · 274 m away - Zoning review
Closed
1267 BLOOR ST W · Sep 29, 2026 · 228 m away - Building permit
Revision 1: Larger second floor deck on main house & garage alterations with new exterior stairProposal for interior alteration to convert existing SFD to a 2 unit dwelling, new 2nd floor deck with new stair to grade and new basement walkout stair
613 LANSDOWNE AVE · Sep 24, 2026 · 169 m away - Building permit
Add a one storey addition at rear and build a new 2nd unit at basement
225 ST HELEN'S AVE · Sep 21, 2026 · 235 m away
Neighbourhood: Dufferin Grove
About the area around the lot, not the lot itself.
- Nearest station
- Lansdowne Station4 min walk
- Nearest TTC stop
- Bloor St West at Lansdowne Ave2 min walk
- Nearest cycling route
- Bloor St WCycle Track, 1 min walk
- Nearest traffic count
- 12,585 vehicles in 14 hBloor St W / St Helen's Ave, 90 m away, Nov 7, 2023
- Serious collisions within 500 m
- 12021–2026, killed or seriously injured: 0 fatal, 1 with pedestrians, 0 with cyclists
- Parks
- Erwin Krickhahn Park3 min walk
- 200 Sterling Road Park4 min walk
- West Toronto Railpath6 min walk
Schools within 1 km
- SAINT FRERE ANDRE SECONDARY SCHOOL French Separate 10 min walk
- TORONTO OUEST SECONDARY SCHOOL French Public 10 min walk
- BISHOP MARROCCO THOMAS MERTON CATHOLIC SECONDARY SCHOOL English Separate 10 min walk
- BLOOR C.I. & ALPHA II ALTERNATIVE English Public 11 min walk
- ST SEBASTIAN CATHOLIC ELEMENTARY SCHOOL English Separate 11 min walk
- BROCK JR PUBLIC SCHOOL English Public 11 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Dufferin Grove | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $78,000 | $84,500 |
| Households that own their home | 42% | 54% |
| Population (2021) | 11,215 | 16,813 |
| Homes built in 1960 or before | 56% | 29% |
| Homes needing major repairs | 10% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Dufferin Grove | City median |
|---|---|---|
| Assault | 1224.5 | 636.3 |
| Robbery | 111.3 | 69.5 |
| Auto theft | 111.3 | 192.6 |
| Theft over $5,000 | 87.5 | 46.1 |
| Break and enter | 270.3 | 172.8 |
| Theft from vehicles | 278.3 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.