HousePrecheckCheck an address

124 Edward StToronto · zoning, lot size and permit records

Also 101 Elm St

Institutional · IH 5.0 (x16)73.4 × 81.8 m5,912 m²on Edward Stcorner, also on Centre Ave

Not a home

A hospital

The zoning by-law sets this parcel aside for a hospital. It is not a home for sale, so the house checks and the pre-offer report do not apply.

Looking at a house nearby? What this means for you

  • A hospital nearbyAmbulances and sirens, traffic and parking at shift changes; care and jobs close by.
  • Permits or applications open on this parcelRecent records on this lot: 26 160862 (HVAC Replacement - Dentistry Building - Level 3, 2026); 26 104815 (Proposed interior alteration to existing spaces in UofT's School of Dentistry building:..., 2026); 26 113184 (Proposed Existing Fire Pump Replacement, 2026); and 1 more. Larger work can mean noise and trucks next door; read what each one is for.
  • 15 development applications open within 300 m, up to 72 storeysNew buildings may go up around here in the next years. More change nearby than at 100% of Toronto houses.
  • Major Transit Station Area: CollegeThe City plans more homes around the station: good for transit, and more building over time.
N50 m
73.4 m frontage81.8 m deep

Before you offer

From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.

  • 4 building permits open, the oldest since 2015

    Needs a closer look

    Still open in the City's records: 22 166862 (Proposal for a stand alone permit to install 24/7 Air Conditioning to Freezer Room #423..., 2022, status Inspection); 22 166858 (Proposal for a stand alone permit to install 24/7 Air Conditioning to Freezer Room #423..., 2022, status Inspection); 16 238690 (Proposal for interior demolition to the 4th and 5th floors of existing university - "Fa..., 2016, status Permit Issued); and 1 more.

    What it means. An open permit can mean work that was never finished or never passed final inspection. After closing, finishing it or closing the file can fall to you.

    How to confirm. Ask the seller for the final inspection records. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details

    City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016)
  • Work or applications in progress

    Good to know

    Recent records on this lot: 26 160862 (HVAC Replacement - Dentistry Building - Level 3, 2026); 26 104815 (Proposed interior alteration to existing spaces in UofT's School of Dentistry building:..., 2026); 26 113184 (Proposed Existing Fire Pump Replacement, 2026); and 1 more.

    What it means. The owner has planned or started work. Ask what it covers, whether it will be finished before closing, and who pays for what is left.

    How to confirm. Application details and decisions are in the City's Application Information Centre. A Property Information Report from Toronto Building lists open permits, inspections and outstanding orders ($214.79, about five business days). Details

    City of Toronto, Building Permits (active, cleared since 2017, cleared 2000-2016); City of Toronto, Committee of Adjustment applications (2001 onwards); City of Toronto, Development Applications
  • 15 development applications open within 300 m

    Good to know

    15 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 72 storeys. They are listed under Around this lot.

    What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.

    How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details

    City of Toronto, Development Applications

Not in these records

  • Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
  • Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.

History of this lot

24 records on file: more than at 100% of Toronto houses (median 0).

  • Building permit26 267455Under Review

    Mechanical retrofit to improve building energy efficiency including working in various building Mechanical rooms and roofs. Work will be done on the chilled water, heating water and glycol piping networks. Equipment will be updated and replaced including rooftop air-source heat pumps, heat recovery chillers, updated air handling equipment, and steam network modifications.

    Nov 9, 2026 · 124 EDWARD ST
  • Building permit26 160862Permit Issued

    HVAC Replacement - Dentistry Building - Level 3

    May 25, 2026 · 124 EDWARD ST
  • Building permit26 104815Permit Issued

    Proposed interior alteration to existing spaces in UofT's School of Dentistry building: lobby, Clinic 1 (ceiling), Clinic 2 (interior fit out), as well as circulation spaces, including an elevator, stairs, and corridors.

    Mar 2, 2026 · 124 EDWARD ST
  • Building permit26 113184Permit Issued

    Proposed Existing Fire Pump Replacement

    Feb 10, 2026 · 124 EDWARD ST
  • Building permit22 215656Closed

    Plumbing - interior alterations to basement floor level of the University of Toronto Faculty of Dentistry building

    Dec 9, 2022 · 124 EDWARD ST
  • Building permit22 166862Inspection

    Proposal for a stand alone permit to install 24/7 Air Conditioning to Freezer Room #423 & #523 c/w connection to energy powering the building - University of Toronto, Dentistry Building

    Jul 21, 2022 · 124 EDWARD ST
  • Building permit22 166858Inspection

    Proposal for a stand alone permit to install 24/7 Air Conditioning to Freezer Room #423 & #523 c/w connection to energy powering the building - University of Toronto, Dentistry Building

    Jul 21, 2022 · 124 EDWARD ST
  • Building permit22 137545Closed

    HVAC - Interior demolition and hazazardous material abatement of interior fit out. Mechanical and electrical coordination wigh architectural demolition work

    May 30, 2022 · 124 EDWARD ST
Show 16 older records
  • Building permit20 206688Closed

    Proposed renovation of existing Senior Laboratory Room in the University of Toronto Faculty of Dentistry building to be a Medical Device Reprocessing Unit, a space where dental equipment is cleaned and sterilized. Also for work associated with new mechanical elements on the roof.

    Feb 9, 2021 · 124 EDWARD ST
  • Building permit20 198959Closed

    Proposed interior alterations to an existing University building. *University of Toronto Dentistry Auditorium*

    Oct 14, 2020 · 124 EDWARD ST
  • Building permit20 181752Closed

    Proposal for interior alterations for the demolition and abatement of interior ceiling and wall finishes - University of Toronto Faculty of Dentistry

    Oct 2, 2020 · 124 EDWARD ST
  • Building permit20 121080Closed

    Proposal for upgrade of building's steam condensate return system in U of T, Faculty of Dentistry

    May 11, 2020 · 124 EDWARD ST
  • Building permit19 261177Closed

    Installation of a new AHU to exhaust hot air from two existing Air Cooled Air Compressors at the University of Toronto's Faculty of Dentistry Building. The new AHU will have an econimizer that will maintain room temperatures during cold months. A split-AC fan coil will provide additional cooling to the mechanical room during warm months.

    Jan 10, 2020 · 124 EDWARD ST
  • Building permit18 170066Closed

    HVAC - Propsoal for interior alterations to mezzanine level of an existing university building. "U of T, Faculty of Dentistry"

    Jul 9, 2018 · 124 EDWARD ST
  • Building permit18 158279Closed

    Proposed domestic cold water line.

    Jun 13, 2018 · 124 EDWARD ST
  • Building permit16 263285Closed

    FS - Sprinkler Shop Drawing - Interior alterations to 4th & 5th floors of University of Toronto building - "Faculty of Dentistry - Wet Lab Revitalization" including related work on the roof to accommodate new mechanical equipments. See active interior demo permit 16 238690 BLD

    Mar 2, 2017 · 124 EDWARD ST
  • Building permit16 238690Permit Issued

    Proposal for interior demolition to the 4th and 5th floors of existing university - "Faculty of Dentistry - Wet lab Revitalization"

    Nov 22, 2016 · 124 EDWARD ST
  • Building permit16 163203Cancelled

    Application for the installation of 4 drains in the office for dental chairs. 4 cold water lines to dental chairs.

    May 27, 2016 · 124 EDWARD ST
  • Building permit15 180506Permit Issued

    Proposal for interior alterations to existing classroom on the 5th floor - Room 518A, U of T, Faculty of Dentistry

    Jul 24, 2015 · 124 EDWARD ST
  • Building permit15 117080Closed

    Proposal to install 1 backflow prevention device in existing U of T building - Dentistry Building #65

    Mar 11, 2015 · 124 EDWARD ST
  • Building permit97 016915Closed

    MAKE ALTERATIONS TO PORTION OF 2ND FLOOR, DENTAL CLINIC. LG

    May 28, 1997 · 124 EDWARD ST
  • Building permit95 018697Closed

    MAKE INTERIOR ALTERATIONS TO PORTION OF BASEMENT AREA BY REMOVING EXISTING LOCKER ROOM AND PROVIDING WASHROOM FACILITIES FOR MEN AND WOMEN. JB

    Jul 27, 1995 · 124 EDWARD ST
  • Zoning review91 026664 LTOClosed
    Jun 26, 1991 · 124 EDWARD ST
  • Zoning review84 027030 LTOClosed
    Nov 27, 1984 · 124 EDWARD ST

Check before you build

  • Site-specific exception 900.31.10(16)

    Needs a closer look

    3 site-specific rules and 1 older by-law that still prevails apply to this lot. They can override the standard rules on this page.

    Zoning By-law 569-2013, Chapter 900
Exception 900.31.10(16)Applies

These parts of the exception apply to this lot's address.

  1. Rule A

    On a lot in the area bounded by College St., Queens Quay, John St. and Church St., a recreation use and an amusement arcade is permitted that is not subject to the required parking rates set out in this By-law; [TO: 438-86; 12(1) 397(ii)]

  2. Rule B

    On a lot , public parking as a principal use in a building or structure is not permitted; and [TO: 438-86; 12(2) 132]

  3. Rule C

    On the lands municipally known as 124 Edward St., despite regulation 80.20.20.100(20)(B), a post-secondary school is not required to be in association with a hospital .

  4. Older by-law A

    Section 12(2) 256 of former City of Toronto By-law 438-86.

By-law 569-2013, Chapter 900

Lot facts

Area
5,912 m²
Frontage
73.4 m
Depth
81.8 m
Street
Edward St
Corner lot
Yes, also on Centre Ave81.8 m along it
Public lane
None
House footprint
4,989 m²
Back yard
1 mhouse to rear lot line
Side yards
0 m and 0.6 mhouse to side lot lines; 0 is a shared wall
Buildings on the lot
13house, garage, sheds
Max height
46 m
Max lot coverage
—

House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.

  • Major Transit Station Area: College. The lot is inside the College Major Transit Station Area approved by the Province (Site and Area Specific Policy 603). Source
  • Downtown Plan Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
  • Downtown building setback overlay. Towers over 36 m here need extra setbacks above 24 m and 25 m between towers. Houses and other low buildings are not affected. Source
  • Zone IH 5.0 (x16) (Institutional Hospital). Chapter 80, section 80.20 of the by-law. Source
  • 5 City trees in front of this lot. The City's street tree inventory lists 5 trees at this address: maple (15 cm), maple (15 cm), maple, norway (15 cm). Diameter is the trunk at breast height. Source

Around this lot

Minor variances approved
88%7 of 8 decisions
Garden suite permits
0
Laneway suite permits
0
Multiplex permits
0
Development applications
26

Within 300 m, last 10 years. 0 suite and multiplex permits: no more than at most Toronto houses (median 3). 8 variance decisions: no more than at most Toronto houses (median 19).

Recent variance decisions in the same zone

  • Minor varianceApproved

    To alter the existing hospital building (Mount Sinai Hospital) by constructing a one-storey addition to the north east corner of the ground floor lobby.

    600 UNIVERSITY AVE · Jul 9, 2014 · 309 m away

Latest activity nearby

  • Consent (lot split)Pending

    To obtain consent to sever the property into two lots and to create new easements/rights-of-way.

    123 EDWARD ST · Oct 2, 2027 · 72 m away
  • Zoning review

    Application On Hold

    522 UNIVERSITY AVE · Nov 24, 2026 · 193 m away
  • Building permit

    Proposal for replacement of existing windows of office floors from Level 2-24.

    700 BAY ST · Nov 24, 2026 · 270 m away
  • Building permit

    Proposal for interior alterations to existing office suite. To include HVAC, sprinkler alterations.

    393 UNIVERSITY AVE · Nov 23, 2026 · 252 m away
  • Building permit

    Proposal for interior demolition of existing office floors from Level 2 - 24.

    700 BAY ST · Nov 23, 2026 · 270 m away
  • Building permit

    Four wall signs.***INTERNATIONAL BUSINESS UNIVERSITY***

    655 BAY ST · Nov 19, 2026 · 292 m away
  • Building permit

    Proposal for interior alterations for Suite 2105 &2103

    180 DUNDAS ST W · Nov 18, 2026 · 115 m away
  • Building permit

    Revision No.1: To change Occupancy Type to B1, No new constructionProposal for interior renovation to room 7A refresh mental health pod - 2hr rating and door/hardware replacement, 1 new toilet and 1 fire damper

    170 ELIZABETH ST · Nov 18, 2026 · 139 m away
  • Building permit

    INTERIOR ALTERATIONS AND CHANGE OF USE FROM YOGA STUDIO TO DANCE STUDIO

    121 DUNDAS ST W · Nov 17, 2026 · 232 m away
  • Building permit

    Tenant improvement to existing office suite located on the 8th floor of 375 University Avenue. No changes of use or exterior work proposed. No change to existing demising walls of suite.

    375 UNIVERSITY AVE · Nov 17, 2026 · 298 m away

Neighbourhood: Yonge-Bay Corridor

About the area around the lot, not the lot itself.

Nearest station
St Patrick Station3 min walk
Nearest TTC stop
Elm St at University Ave East Side1 min walk
Nearest cycling route
University AveCycle Track, 2 min walk
Nearest traffic count
9,591 vehicles in 14 hElizabeth St / Elm St, 130 m away, Jan 28, 2025
Serious collisions within 500 m
42021–2026, killed or seriously injured: 0 fatal, 2 with pedestrians, 1 with cyclists
Parks
Larry Sefton Park5 min walk
College Park6 min walk
Trinity Square6 min walk

Schools within 1 km

  • TORONTO METROPOLITAN UNIVERSITY - ENTR TO BUSINESS SCHOOL LOBBY University 6 min walk
  • CONTACT ALTERNATIVE SCHOOL English Public 6 min walk
  • OCAD UNIVERSITY - THE LEARNING ZONE University 6 min walk
  • OCAD UNIVERSITY - ROSALIE SHARP PAVILION University 7 min walk
  • OCAD UNIVERSITY - ANNEX BUILDING University 7 min walk
  • ORDE STREET JR PUBLIC SCHOOL English Public 8 min walk

Being near a school does not mean the lot is in its catchment; check with the board.

2021 Census

FigureYonge-Bay CorridorMedian neighbourhood
Median household income (2020)$68,500$84,500
Households that own their home32%54%
Population (2021)12,64516,813
Homes built in 1960 or before2%29%
Homes needing major repairs2%7%

Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.

Police-reported crime, 2025

Per 100,000 peopleYonge-Bay CorridorCity median
Assault3361.1636.3
Robbery300.169.5
Homicide125.3
Shootings1210.5
Auto theft162.1192.6
Theft over $5,000210.146.1
Break and enter552.2172.8
Theft from vehicles402.1188.1

Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.

Something here not right?

Sources

  • Building permits on this lot since 2000: Permits issued or applied for since about 2000, with status.
  • Committee of Adjustment files since 2001: Minor variances and consents (lot splits) on this lot and nearby, with decisions.
  • Development applications: Rezoning, site plan, subdivision and condominium applications.
  • Preliminary zoning reviews: Zoning reviews requested before a permit or variance application.
  • Zoning and overlays: Zoning By-law 569-2013 zone, height, coverage, policy area, parking, rooming house, priority retail street and downtown setback overlays.
  • Lot boundary, street and lane: Lot polygon, its addresses, the street it fronts, corner and public lane contact, with frontage and depth measured from the boundary; City of Toronto land in City use, which is not a home.
  • House and yards: Footprint and roof height of the house and other buildings, and the yard behind the house, from the City's 3D Massing (updated yearly, illustrative).
  • City trees in front of the lot: City-owned trees on the street allowance at this address, with species and trunk diameter. Private trees on the lot are not in open data.
  • Heritage: Heritage Register (listed and designated properties), Official Plan Amendment 720 properties and properties removed from the Register under the 2022 two-year limit.
  • TRCA regulated area: Valleys, floodplains, shorelines and wetlands regulated by the Toronto and Region Conservation Authority.
  • Ravines and natural features: Ravine and Natural Feature Protection area (Chapter 658, map last published 2019), Natural Heritage System and Environmentally Significant Areas.
  • Official Plan policies: Site and Area Specific Policies, Secondary Plans and Major Transit Station Areas covering the lot.
  • Rooming houses, short-term rentals and rental buildings: Multi-tenant house licences, short-term rental registrations and RentSafeTO evaluations at this address.
  • Neighbourhood context: Neighbourhood, 2021 Census figures, police-reported crime rates, schools, parks, TTC stops, cycling routes, serious collisions and traffic counts nearby. Area context only, not a finding about the lot.
  • Orders and by-law investigations: Outstanding Toronto Building orders, and by-law investigations open now or closed in the last two years. Fire and Public Health orders and older closed files are not published.
  • Address points: loaded Nov 22, 2026, published Nov 20, 2026
  • Toronto Building orders: loaded Nov 27, 2026, published Nov 26, 2026
  • Neighbourhood Profiles, 2021 Census: loaded Oct 14, 2026, published Oct 6, 2023
  • Street centrelines: loaded Nov 22, 2026, published Nov 20, 2026
  • City-owned land: loaded Nov 22, 2026, published Nov 16, 2026
  • Committee of Adjustment open applications: loaded Nov 27, 2026, published Nov 26, 2026
  • Committee of Adjustment decisions: loaded Nov 27, 2026, published Nov 26, 2026
  • Committee of Adjustment decisions 2001-2016: loaded Oct 14, 2026, published Feb 20, 2026
  • Collisions with people killed or seriously injured (Toronto Police Service): loaded Nov 22, 2026, published Nov 21, 2026
  • Neighbourhood crime rates (Toronto Police Service): loaded Oct 14, 2026, published Feb 20, 2026
  • Cycling network: loaded Nov 22, 2026, published Nov 16, 2026
  • Development applications: loaded Nov 27, 2026, published Nov 27, 2026
  • Environmentally Significant Areas: loaded Oct 14, 2026, published Mar 16, 2026
  • Green spaces: loaded Nov 15, 2026, published Nov 10, 2026
  • Heritage register: loaded Oct 14, 2026, published Sep 1, 2026
  • Former heritage listings: loaded Oct 14, 2026, published Jul 3, 2025
  • Official Plan Amendment 720 heritage list: loaded Oct 14, 2026, published Sep 1, 2026
  • 3D Massing building footprints: loaded Oct 14, 2026, published Dec 2, 2025
  • By-law investigation addresses: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigation deficiencies: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigations: loaded Nov 27, 2026, published Nov 26, 2026
  • Major Transit Station Areas: loaded Oct 14, 2026, published Feb 3, 2026
  • Natural Heritage System: loaded Oct 14, 2026, published Mar 16, 2026
  • Neighbourhoods: loaded Oct 14, 2026, published Feb 20, 2026
  • Property boundaries: loaded Nov 27, 2026, published Nov 27, 2026
  • Active building permits: loaded Nov 27, 2026, published Nov 26, 2026
  • Cleared building permits: loaded Nov 27, 2026, published Nov 26, 2026
  • Cleared building permits 2000-2016: loaded Oct 14, 2026, published Jul 8, 2025
  • Preliminary zoning reviews: loaded Nov 27, 2026, published Nov 26, 2026
  • Ravine and natural feature protection: loaded Oct 14, 2026, published Jul 23, 2019
  • RentSafeTO evaluations: loaded Nov 27, 2026, published Nov 26, 2026
  • Multi-tenant house licences: loaded Nov 27, 2026, published Nov 26, 2026
  • Site and Area Specific Policies: loaded Oct 14, 2026, published Mar 16, 2026
  • School locations: loaded Oct 14, 2026, published May 27, 2026
  • Secondary Plans: loaded Oct 14, 2026, published Mar 16, 2026
  • Street trees: loaded Oct 14, 2026, published Jun 4, 2026
  • Short-term rental registrations: loaded Nov 27, 2026, published Nov 26, 2026
  • Traffic counts at intersections: loaded Nov 22, 2026, published Nov 21, 2026
  • TRCA regulation limit: loaded Oct 14, 2026, published Apr 29, 2026
  • TTC stops (GTFS): loaded Nov 8, 2026, published Nov 5, 2026
  • Zoning by-law: loaded Oct 14, 2026, published Feb 20, 2026
  • Lot coverage overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Height overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Parking zone overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Policy area overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Priority retail streets: loaded Oct 14, 2026, published Feb 20, 2026
  • Rooming house overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Zoning setbacks: loaded Oct 14, 2026, published Feb 20, 2026

Contains information licensed under the Open Government Licence – Toronto. TRCA regulation limit © TRCA.

Screening tool based on City of Toronto and TRCA open data. Not a zoning review or legal opinion. Site-specific exceptions, amendments not yet in the open data, minor variances and other by-laws can change the answer. Confirm with a Preliminary Project Review or Zoning Certificate from Toronto Building before buying or designing.

Flag an error

What is not right?

The problem

The records come from the City's open data; we check each flag against them. Your email is used only to answer this.