HousePrecheckCheck an address

110 Keewatin AveToronto · zoning, lot size and permit records

Residential · R (f9.0; u4; d0.6) (x954)22.9 × 60.6 m1,383 m²on Keewatin Ave

Not a single house

A rental apartment building

The City's RentSafeTO program evaluates this building as a rental apartment building (three storeys and ten units or more). Build options for a house do not apply.

Looking at a house nearby? What this means for you

  • 3 storeys, 32 rental units, built 1955More people, cars and deliveries than a street of houses alone. A tall building also shades the lots to its north.
  • 8 development applications open within 300 m, up to 39 storeysNew buildings may go up around here in the next years. More change nearby than at 99% of Toronto houses.
  • City upkeep score: 96 out of 100RentSafeTO rates common areas, building systems and records. A low score can show from the street.

Want to check this building before you buy?

We are building checks for apartment buildings. Leave your email and we will tell you when it is ready.

N20 m
22.9 m frontage60.6 m deep

Before you offer

From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.

  • 5 by-law investigations closed in the last two years

    Good to know

    Closed files (Adequate Heat, Order Issued Property Standards, Property Standards): 26 214322 PRS 00 IV (Order Issued Property Standards: In a dwelling unit, a window located more than 2,000 m..., 2026); 26 214308 PRS 00 IR (Property Standards, 2026); 26 170770 000 00 IR (Adequate Heat, 2026); and 2 more.

    What it means. Someone raised an issue here and the City closed the file. Ask the seller what it was about.

    City of Toronto, Toronto Building orders and Municipal Licensing and Standards investigations
  • 8 development applications open within 300 m

    Good to know

    8 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 39 storeys. They are listed under Around this lot.

    What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.

    How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details

    City of Toronto, Development Applications
  • Rental building evaluation: 96 out of 100

    Good to know

    The City's RentSafeTO program evaluated this rental building in 2026 (3 storeys, 32 units, built 1955).

    What it means. The score covers common areas, building systems and records. Read the evaluation details for the items that scored low.

    How to confirm. The City's RentSafeTO page has the evaluation results and any open orders for the building. Details

    City of Toronto, RentSafeTO Apartment Building Evaluations

Not in these records

  • Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
  • Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.

History of this lot

6 records on file: more than at 95% of Toronto houses (median 0).

  • By-law investigation26 214322 PRS 00 IVClosed

    Order Issued Property Standards: In a dwelling unit, a window located more than 2,000 millimetres above grade opens within 1,500 millimetres of the floor not leading to a balcony does not emplo

    Aug 5, 2026 · 110 KEEWATIN AVE
  • By-law investigation26 214308 PRS 00 IRClosed

    Property Standards

    Aug 5, 2026 · 110 KEEWATIN AVE
  • By-law investigation26 170770 000 00 IRClosed

    Adequate Heat

    Jun 1, 2026 · 110 KEEWATIN AVE
  • By-law investigation26 170769 000 00 IRClosed

    Property Standards

    Jun 1, 2026 · 110 KEEWATIN AVE
  • By-law investigation24 245373 HEA 00 IRClosed

    Adequate Heat

    Nov 30, 2024 · 110 KEEWATIN AVE
  • Building permit24 142719Closed

    RP - 1 1/2" Watts LF009 Backflow Device with strainer & Watts PLT-35 Thermal Expansion Tank with isolation & Drain

    May 27, 2024 · 110 KEEWATIN AVE

Check before you build

  • Site-specific exception 900.2.10(954)

    Needs a closer look

    6 site-specific rules and 2 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.

    Zoning By-law 569-2013, Chapter 900
Exception 900.2.10(954)Applies

These parts of the exception apply to this lot's address.

  1. Rule A

    Any addition or extension above the first storey of a lawfully existing detached house must comply with the minimum building setbacks required by this By-law; [TO: 438-86; 12 (2) 193]

  2. Rule B

    The lands must comply with exception 900.2.10(5)

  3. Rule C

    Despite (B), a maximum of three dwelling units are permitted in a townhouse ; [TO: 438-86; 12(1)68 (a)]

  4. Rule D

    Despite (B) and (C), the use of a lot for dwelling units in a townhouse , triplex , fourplex or apartment building is permitted if the lot was used for such purpose on March 13, 1978; [TO: 438-86; 12(1)68 (d) (i)]

  5. Rule E

    Despite (B) and (C) the use of a lot for dwelling units in a townhouse , triplex , fourplex or apartment building built after March 13, 1978 is permitted if the same building type existed on the lot on March 13, 1978; and [TO: 438-86; 12(1)68 (d) (ii)]

  6. Rule F

    A detached house may be converted to contain two or more secondary suites in compliance with Section 150.10 if the building has a minimum interior floor area of 140 square metres. [TO: 438-86; 12(1)68 (c)]

  7. Older by-law A

    Section 12(2) 118 of former City of Toronto By-law 438-86

  8. Older by-law B

    Section 12(2) 119 of former City of Toronto By-law 438-86

3 parts for other addresses
  • C On 88 Keewatin Ave. and 1015R Mount Pleasant Rd., former City of Toronto by-laws 598-78, 728-78 and 326-80
  • D On the even numbered addresses of 260-416 Keewatin Ave., former City of Toronto by-laws 375-78 and 716-78
  • E On 13 Sherwood Lane, former City of Toronto by-laws 728-78 and 326-80.
By-law 569-2013, Chapter 900

Lot facts

Area
1,383 m²
Frontage
22.9 m
Depth
60.6 m
Street
Keewatin Ave
Corner lot
No
Public lane
None
House footprint
634 m²roof up to 15.5 m
Back yard
7.9 mhouse to rear lot line
Side yards
4 m and 4.2 mhouse to side lot lines
Buildings on the lot
1house, garage, sheds
Max height
10 m
Max lot coverage
—

House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.

  • Yonge-Eglinton Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
  • Minimum frontage 9 m. Frontage is about 22.9 m: meets the zone minimum. Source
  • Zone R (f9.0; u4; d0.6) (x954) (Residential). Chapter 10, section 10.10 of the by-law. Source

Around this lot

Minor variances approved
90%28 of 31 decisions
Garden suite permits
2
Laneway suite permits
0
Multiplex permits
2
Development applications
19

Within 300 m, last 10 years. 4 suite and multiplex permits: more than at 54% of Toronto houses (median 3). 31 variance decisions: more than at 64% of Toronto houses (median 19).

Recent variance decisions in the same zone

  • Minor varianceRefused

    To construct a new three (3) storey detached dwelling with a secondary suite in the basement.File Numbers B0016/26NY, A0267/26NY & A0268/26NY will be considered jointly.

    80 SHERWOOD AVE · Nov 12, 2026 · 148 m away
  • Minor varianceRefused

    To construct a new three (3) storey detached dwelling with a secondary suite in the basement.File Numbers B0016/26NY, A0267/26NY & A0268/26NY will be considered jointly.

    80 SHERWOOD AVE · Nov 12, 2026 · 148 m away
  • Minor varianceApproved

    To alter the existing two-storey detached dwelling and construct a two-storey rear addition.

    12 BLYTHWOOD RD · Jun 4, 2026 · 496 m away
  • Minor varianceApproved

    To alter the existing semi-detached dwelling by constructing a rear second storey addition.

    50 SHERWOOD AVE · May 21, 2026 · 124 m away
  • Minor varianceApproved

    To alter the development standards for the 50-storey mixed-use building (approved under Site-Specific Zoning By-law 1133-2023) by permitting a non-residential use (eating establishment/take-out eating establishment with an outdoor patio abutting Redpath Avenue) at-grade and increasing the total number of small vehicle parking spaces to 8 parking spaces. This building will contain 599 residential dwelling units including 15 rental replacement units.

    170 ROEHAMPTON AVE · Apr 1, 2026 · 492 m away

Latest activity nearby

  • Building permit

    Install a Electro Magnetic Locking Device on PH Level (17th floor)

    55 ERSKINE AVE · Nov 24, 2026 · 228 m away
  • Consent (lot split)Refused

    To obtain consent to sever the existing property into two residential lots. File Numbers B0016/26NY, A0267/26NY & A0268/26NY will be considered jointly.

    80 SHERWOOD AVE · Nov 12, 2026 · 148 m away
  • Minor varianceRefused

    To construct a new three (3) storey detached dwelling with a secondary suite in the basement.File Numbers B0016/26NY, A0267/26NY & A0268/26NY will be considered jointly.

    80 SHERWOOD AVE · Nov 12, 2026 · 148 m away
  • Minor varianceRefused

    To construct a new three (3) storey detached dwelling with a secondary suite in the basement.File Numbers B0016/26NY, A0267/26NY & A0268/26NY will be considered jointly.

    80 SHERWOOD AVE · Nov 12, 2026 · 148 m away
  • Building permitgarden suite

    Revision 01 to remove the proposed second storey windows facing the north lot line and install skylights to the primary bedroom and bathroom. Proposed 2 storey garden suite

    38 KEEWATIN AVE · Nov 10, 2026 · 181 m away
  • Building permit

    Proposed Addition and Interior Alterations.

    50 SHERWOOD AVE · Nov 2, 2026 · 124 m away
  • Zoning review

    Closed

    2481 YONGE ST · Oct 23, 2026 · 288 m away
  • Building permit

    Proposed to construct a new storage shed in the backyard

    121 SHERWOOD AVE · Oct 22, 2026 · 258 m away
  • Zoning review

    Closed

    2528 YONGE ST · Oct 15, 2026 · 298 m away
  • Zoning review

    Closed

    2487 YONGE ST · Sep 9, 2026 · 285 m away

Neighbourhood: Mount Pleasant East

About the area around the lot, not the lot itself.

Nearest station
Mount Pleasant Station12 min walk
Nearest TTC stop
Yonge St at Sherwood Ave4 min walk
Nearest cycling route
Broadway AveSigned Route (No Pavement Markings), 6 min walk
Nearest traffic count
2,772 vehicles in 8 hErskine Ave / Redpath Ave / Redpath Avenue Parkette Trl, 210 m away, Mar 24, 2021
Serious collisions within 500 m
62021–2026, killed or seriously injured: 0 fatal, 4 with pedestrians, 0 with cyclists
Parks
85 Keewatin Ave Park1 min walk
Redpath Avenue Parkette2 min walk
St. Clements - Yonge Parkette5 min walk

Schools within 1 km

  • JOHN FISHER JR PUBLIC SCHOOL English Public 3 min walk
  • ST CLEMENTS SCHOOL Private 5 min walk
  • ST MONICA CATHOLIC ELEMENTARY SCHOOL English Separate 6 min walk
  • NORTH TORONTO COLLEGIATE INSTITUTE English Public 6 min walk
  • ST CLEMENTS EARLY LEARNING Private 7 min walk
  • BLYTH ACADEMY SCHOOL - LAWRENCE PARK Private 7 min walk

Being near a school does not mean the lot is in its catchment; check with the board.

2021 Census

FigureMount Pleasant EastMedian neighbourhood
Median household income (2020)$110,000$84,500
Households that own their home55%54%
Population (2021)16,37016,813
Homes built in 1960 or before52%29%
Homes needing major repairs5%7%

Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.

Police-reported crime, 2025

Per 100,000 peopleMount Pleasant EastCity median
Assault336.5636.3
Robbery10.269.5
Auto theft224.4192.6
Theft over $5,00045.946.1
Break and enter204172.8
Theft from vehicles107.1188.1

Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.

Something here not right?

Sources

  • Building permits on this lot since 2000: Permits issued or applied for since about 2000, with status.
  • Committee of Adjustment files since 2001: Minor variances and consents (lot splits) on this lot and nearby, with decisions.
  • Development applications: Rezoning, site plan, subdivision and condominium applications.
  • Preliminary zoning reviews: Zoning reviews requested before a permit or variance application.
  • Zoning and overlays: Zoning By-law 569-2013 zone, height, coverage, policy area, parking, rooming house, priority retail street and downtown setback overlays.
  • Lot boundary, street and lane: Lot polygon, its addresses, the street it fronts, corner and public lane contact, with frontage and depth measured from the boundary; City of Toronto land in City use, which is not a home.
  • House and yards: Footprint and roof height of the house and other buildings, and the yard behind the house, from the City's 3D Massing (updated yearly, illustrative).
  • City trees in front of the lot: City-owned trees on the street allowance at this address, with species and trunk diameter. Private trees on the lot are not in open data.
  • Heritage: Heritage Register (listed and designated properties), Official Plan Amendment 720 properties and properties removed from the Register under the 2022 two-year limit.
  • TRCA regulated area: Valleys, floodplains, shorelines and wetlands regulated by the Toronto and Region Conservation Authority.
  • Ravines and natural features: Ravine and Natural Feature Protection area (Chapter 658, map last published 2019), Natural Heritage System and Environmentally Significant Areas.
  • Official Plan policies: Site and Area Specific Policies, Secondary Plans and Major Transit Station Areas covering the lot.
  • Rooming houses, short-term rentals and rental buildings: Multi-tenant house licences, short-term rental registrations and RentSafeTO evaluations at this address.
  • Neighbourhood context: Neighbourhood, 2021 Census figures, police-reported crime rates, schools, parks, TTC stops, cycling routes, serious collisions and traffic counts nearby. Area context only, not a finding about the lot.
  • Orders and by-law investigations: Outstanding Toronto Building orders, and by-law investigations open now or closed in the last two years. Fire and Public Health orders and older closed files are not published.
  • Address points: loaded Nov 22, 2026, published Nov 20, 2026
  • Toronto Building orders: loaded Nov 28, 2026, published Nov 27, 2026
  • Neighbourhood Profiles, 2021 Census: loaded Oct 14, 2026, published Oct 6, 2023
  • Street centrelines: loaded Nov 22, 2026, published Nov 20, 2026
  • City-owned land: loaded Nov 22, 2026, published Nov 16, 2026
  • Committee of Adjustment open applications: loaded Nov 28, 2026, published Nov 27, 2026
  • Committee of Adjustment decisions: loaded Nov 28, 2026, published Nov 27, 2026
  • Committee of Adjustment decisions 2001-2016: loaded Oct 14, 2026, published Feb 20, 2026
  • Collisions with people killed or seriously injured (Toronto Police Service): loaded Nov 22, 2026, published Nov 21, 2026
  • Neighbourhood crime rates (Toronto Police Service): loaded Oct 14, 2026, published Feb 20, 2026
  • Cycling network: loaded Nov 22, 2026, published Nov 16, 2026
  • Development applications: loaded Nov 28, 2026, published Nov 28, 2026
  • Environmentally Significant Areas: loaded Oct 14, 2026, published Mar 16, 2026
  • Green spaces: loaded Nov 15, 2026, published Nov 10, 2026
  • Heritage register: loaded Oct 14, 2026, published Sep 1, 2026
  • Former heritage listings: loaded Oct 14, 2026, published Jul 3, 2025
  • Official Plan Amendment 720 heritage list: loaded Oct 14, 2026, published Sep 1, 2026
  • 3D Massing building footprints: loaded Oct 14, 2026, published Dec 2, 2025
  • By-law investigation addresses: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigation deficiencies: loaded Nov 23, 2026, published Nov 22, 2026
  • By-law investigations: loaded Nov 28, 2026, published Nov 27, 2026
  • Major Transit Station Areas: loaded Oct 14, 2026, published Feb 3, 2026
  • Natural Heritage System: loaded Oct 14, 2026, published Mar 16, 2026
  • Neighbourhoods: loaded Oct 14, 2026, published Feb 20, 2026
  • Property boundaries: loaded Nov 27, 2026, published Nov 27, 2026
  • Active building permits: loaded Nov 28, 2026, published Nov 27, 2026
  • Cleared building permits: loaded Nov 28, 2026, published Nov 27, 2026
  • Cleared building permits 2000-2016: loaded Oct 14, 2026, published Jul 8, 2025
  • Preliminary zoning reviews: loaded Nov 28, 2026, published Nov 27, 2026
  • Ravine and natural feature protection: loaded Oct 14, 2026, published Jul 23, 2019
  • RentSafeTO evaluations: loaded Nov 28, 2026, published Nov 27, 2026
  • Multi-tenant house licences: loaded Nov 28, 2026, published Nov 27, 2026
  • Site and Area Specific Policies: loaded Oct 14, 2026, published Mar 16, 2026
  • School locations: loaded Oct 14, 2026, published May 27, 2026
  • Secondary Plans: loaded Oct 14, 2026, published Mar 16, 2026
  • Street trees: loaded Oct 14, 2026, published Jun 4, 2026
  • Short-term rental registrations: loaded Nov 28, 2026, published Nov 27, 2026
  • Traffic counts at intersections: loaded Nov 22, 2026, published Nov 21, 2026
  • TRCA regulation limit: loaded Oct 14, 2026, published Apr 29, 2026
  • TTC stops (GTFS): loaded Nov 8, 2026, published Nov 5, 2026
  • Zoning by-law: loaded Oct 14, 2026, published Feb 20, 2026
  • Lot coverage overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Height overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Parking zone overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Policy area overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Priority retail streets: loaded Oct 14, 2026, published Feb 20, 2026
  • Rooming house overlay: loaded Oct 14, 2026, published Feb 20, 2026
  • Zoning setbacks: loaded Oct 14, 2026, published Feb 20, 2026

Contains information licensed under the Open Government Licence – Toronto. TRCA regulation limit © TRCA.

Screening tool based on City of Toronto and TRCA open data. Not a zoning review or legal opinion. Site-specific exceptions, amendments not yet in the open data, minor variances and other by-laws can change the answer. Confirm with a Preliminary Project Review or Zoning Certificate from Toronto Building before buying or designing.

Flag an error

What is not right?

The problem

The records come from the City's open data; we check each flag against them. Your email is used only to answer this.