Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
3 development applications open within 300 m
Good to know3 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 36 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
No permits, applications or Committee of Adjustment files on this lot in the City's open records.
Check before you build
Site-specific exception 900.7.10(144)
Needs a closer look21 site-specific rules apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule B
to (V) below; (B) Only a day nursery is permitted in Building F, as shown on Diagram 3 of By-law 656-2020, and regulation 150.45.20.1(1), with respect to the location of a day nursery , does not apply to restrict a day nursery occupying an entire building
- Rule C
Despite Regulation 15.10.40.40(1), the permitted maximum gross floor area for all uses is 65,070 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 64,700 square metres; and (ii) the permitted maximum gross floor area for non-residential uses is 362 square metres and is restricted to a day nursery use
- Rule D
The permitted maximum number of dwelling units is 960 of which: (i) a minimum of 50 percent of all the units are 2 bedroom or larger; (ii) a minimum of 20 percent of all the units are 3 bedroom; and (iii) Within Buildings A, B and C, as shown on Diagram 3 of By-law 656-2020: (a) 30 percent of all bachelor units must not exceed a maximum of 46.5 square metres; (b) 30 percent of all one bedroom (including one bedroom plus den) units must not exceed a maximum of 60.5 square metres; (c) 30 percent of all two bedroom (including two bedroom plus den) units must not exceed a maximum 79 square metres; (d) 30 percent of all three bedroom (including three bedroom plus den) units must not exceed a maximum of 93 square metres; and (iv) Within Buildings D and E, as shown on Diagram 3 of By-law 656-2020: (a) 30 percent of all two bedroom units must not exceed a maximum of 120 square metres; (b) 30 percent of all three bedroom units must not exceed a maximum of 120 square metres
- Rule E
Despite regulations 15.5.40.10(1), the height of each building , as shown on Diagram 3 of By-law 656-2020, is the distance between the specified Geodetic Datum Elevation and the highest point of each building , as follows: (i) 119.00 for Building "A" and attached podium; (ii) 125.50 for Building "B" and Building "C"; (iii) 122.96 for Building "D"; (iv) 119.91 for Building "E"; and (v) 125.75 for Building "F"
- Rule F
Despite regulation 15.10.40.10(1), the permitted maximum height of a building or structure is the height in metres specified by the number following the symbol HT as shown on Diagram 3 of By-law 656-2020
- Rule G
Despite (F) above, the following building elements and structures are permitted to project above the permitted maximum height: (i) parapets, pergolas, trellises, eaves, screens, roof drainage, lightning rods, architectural features, elements of a green roof , structures for noise attenuation, ornamental elements, terrace and balcony guard rails and dividers, railings, decorative screens, by a maximum of 3.0 metres
- Rule H
Despite Clause 15.10.40.70, the required minimum building setbacks are shown on Diagram 3 of By-law 656-2020
- Rule I
Despite Clauses and Regulations 150.45.50.1, 15.5.40.60, 15.10.40.70, the following are permitted to encroach into a required building setback and separation distances: (i) porch, patio, terrace, balustrades, cornices, eaves, guardrails, landscape and green roof elements, lighting fixtures, ornamental elements, public art features, railings, trellis, underground garage ramps, vents, wheelchair ramps, wind mitigation features and window sills to a maximum of 4.0 metres; (ii) balconies on Buildings A, B and C up to a maximum of 1.5 metres; (iii) canopies up to a maximum of 4.5 metres; (iv) air shafts, exterior stairs, stair enclosures may encroach and no closer to a lot line than 0.0 metres; (v) Children's Play Area associated with the day nursery up to a maximum of 3.0 metres
- Rule J
Despite Regulations 15.10.40.80(1)(A)(i) and 15.10.40.80(1)(B), the required minimum above ground separation distance between main walls with no opening to dwelling units in one or more of those main walls is 3.39 metres.
- Rule K
Any building or structure may not penetrate the following 45 degree angular planes projected over the lot from the ground level at the face of buildings located: (i) on the adjoining lot to the north and facing south; and (ii) on the lot on the opposite side of Brandon Avenue and facing south
- Rule L
Despite Regulation 5.10.30.20(1), the front lot line is the lot line abutting Lansdowne Avenue
- Rule M
Despite Regulation 15.5.40.10 (4), the total area of the equipment described in clause (G) of this exception may cover no more than 54 percent of the area of the roof
- Rule N
Despite Regulation 15.5.60.1(4), above-ground parts of an ancillary building or structure may be erected prior to the erection of the main walls and completion of the roof of a residential building on the same lot
- Rule O
Despite Regulation 15.5.100.1(1), the permitted maximum total width of a driveway for an apartment building is 9.3 metres
- Rule P
Regulation 15.10.40.50.1b) does not apply.
- Rule Q
Despite Regulation 15.10.40.50(1), amenity space must be provided in accordance with the following: (i) A minimum of 1,920 square metres of indoor amenity space must be provided; and (ii) A minimum of 5,450 square metres of outdoor amenity space must be provided
- Rule R
Despite Clause 15.10.30.40, the permitted maximum lot coverage is 32 percent of the lot area
- Rule S
Despite Regulation 15.5.50.10 (1), a minimum of 56 percent of area of the lot must be maintained as landscaping and a minimum of 33 percent of the area of the lot must be maintained as soft landscaping .
- Rule T
Despite regulation 200.5.10.1(1), parking spaces must be provided as follows: (i) Buildings A, B and C: (a) Resident Parking – 0.63 spaces per dwelling unit ; and (b) Visitor Parking – 0.2 spaces per dwelling unit ; (ii) Buildings D and E: (a) Resident Parking – 1 space per dwelling unit ; and (b) Visitor Parking – 0.12 spaces per dwelling unit ; (iii) Building F (a) 1 parking space for each 100 square metres of gross floor area
- Rule U
Despite regulation 200.15.10(1), accessible parking spaces must be provided at a minimum rate of 4 accessible parking spaces plus 1 accessible parking space for every 50 parking spaces or part thereof in excess of 100 parking spaces .
- Rule V
Despite regulations 220.5.10.1(2) and 220.5.1.10(8)(D), a minimum of 3 type 'G'; loading spaces must be provided with the following dimensions: (i) A minimum length of 13.0 metres; (ii) A minimum width of 4.0 metres; and (iii) A minimum of vertical clearance of 6.1 metres.
1 part for other addresses
- A On 900 and 980 Lansdowne Avenue, if the requirements of Section 7 and Schedule A of By-law 656-2020 are complied with, a building , structure , addition or …
Lot facts
- Area
- 11,443 m²
- Frontage
- 116.5 mestimated, irregular lot
- Depth
- 122.6 mestimated, irregular lot
- Street
- Brandon Ave
- Corner lot
- Yes, also on Foundry Ave122.6 m along it
- Public lane
- None
- Max height
- 75 m
- Max lot coverage
- —
Around this lot
- Minor variances approved
- 94%16 of 17 decisions
- Garden suite permits
- 0
- Laneway suite permits
- 2
- Multiplex permits
- 7
- Development applications
- 7
Within 300 m, last 10 years. 9 suite and multiplex permits: more than at 72% of Toronto houses (median 3). 17 variance decisions: no more than at most Toronto houses (median 19).
Recent variance decisions in the same zone
- Minor varianceApproved
To reduce the width and length of 28 parking spaces provided for small vehicles. There will be a total of 827 parking spaces provided on-site.
900 LANSDOWNE AVE · Apr 26, 2023 · 92 m away
Latest activity nearby
- Minor variancePending
In Process
881 ST CLARENS AVE · Nov 18, 2026 · 282 m away - Building permit
Proposal for second and third floor alterations.
811 ST CLARENS AVE · Nov 10, 2026 · 239 m away - Building permit
Second & Third Floor Interior Alterations
819 ST CLARENS AVE · Nov 10, 2026 · 239 m away - Building permit
Secont & Third Floor Interior Alterations
817 ST CLARENS AVE · Nov 10, 2026 · 239 m away - Building permit
Second & Third Floor Interior Alterations
815 ST CLARENS AVE · Nov 10, 2026 · 239 m away - Building permit
Second & Third Floor Interior Alterations
813 ST CLARENS AVE · Nov 10, 2026 · 239 m away - Zoning review
Cancelled
1401 DUPONT ST · Nov 3, 2026 · 230 m away - Building permit
Proposed installation of main drain backwater valve.
389 SYMINGTON AVE · Sep 29, 2026 · 278 m away - Building permit
Localized Garage Repairs, which includes: Localized Normal, heavy, and extra heavy duty waterproofing repairs, including localkized topisde, through slab, vertical, and ledge beam repairs. This also includes expansion joint replacement and drains grates replacement. Convenience address is 1410-1420 Dupont St
830 LANSDOWNE AVE · Sep 22, 2026 · 172 m away - Building permit
Administrative permit for the shared centre porch column located on the mutual property line between41 and 43 Brandon Ave, associated with the proposed porch work under Building Permit ApplicationNo. 26 193822 BLD 00 SR for 41 Brandon Ave
143 BRANDON AVE · Sep 21, 2026 · 270 m away
Neighbourhood: Junction-Wallace Emerson
About the area around the lot, not the lot itself.
- Nearest station
- Lansdowne Station18 min walk
- Nearest TTC stop
- Lansdowne Ave at Brandon Ave3 min walk
- Nearest cycling route
- Dupont StBike Lane, 3 min walk
- Nearest traffic count
- 8,888 vehicles in 8 hLansdowne Ave / Brandon Ave, 140 m away, Jan 15, 2015
- Serious collisions within 500 m
- 62021–2026, killed or seriously injured: 2 fatal, 4 with pedestrians, 1 with cyclists
- Parks
- Davenport Village Park1 min walk
- Symington Avenue Playground5 min walk
- Primrose Avenue Parkette6 min walk
Schools within 1 km
- ECOLE ELEMENTAIRE CHARLES SAURIOL French Public 9 min walk
- ST LUIGI CATHOLIC ELEMENTARY SCHOOL English Separate 10 min walk
- PERTH AVENUE JR PUBLIC SCHOOL English Public 11 min walk
- ST RITA CATHOLIC ELEMENTARY SCHOOL & MSGR FRASER SOUTHWEST English Separate 11 min walk
- ST MARY OF THE ANGELS CATHOLIC ELEMENTARY SCHOOL English Separate 13 min walk
- ST SEBASTIAN CATHOLIC ELEMENTARY SCHOOL English Separate 15 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Junction-Wallace Emerson | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $84,000 | $84,500 |
| Households that own their home | 50% | 54% |
| Population (2021) | 23,180 | 16,813 |
| Homes built in 1960 or before | 40% | 29% |
| Homes needing major repairs | 7% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Junction-Wallace Emerson | City median |
|---|---|---|
| Assault | 720 | 636.3 |
| Robbery | 36 | 69.5 |
| Shootings | 3.6 | 10.5 |
| Auto theft | 108 | 192.6 |
| Theft over $5,000 | 32.4 | 46.1 |
| Break and enter | 230.4 | 172.8 |
| Theft from vehicles | 201.6 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.