Before you offer
From the City's records on this lot. Each item says what it means for a purchase and how to confirm it.
12 development applications open within 300 m
Good to know12 rezoning, site plan, subdivision or condominium applications within 300 m, submitted in the last 10 years, are not closed yet, including buildings of up to 54 storeys. They are listed under Around this lot.
What it means. New buildings nearby can change views, sunlight, traffic and construction noise for years.
How to confirm. Each application, its drawings and its status are in the Application Information Centre. Details
City of Toronto, Development Applications
Not in these records
- Flooding history. Past basement flooding and insurance claims on this house are not published. Ask the seller directly and ask your insurer before you firm up the offer.
- Ownership, mortgages and easements. Title is not open data. Your lawyer searches title after the offer; ask for the survey and any easements before.
History of this lot
1 records on file: more than at 53% of Toronto houses (median 0).
- By-law investigation25 234665 WST 00 IRClosed
Waste
Oct 3, 2025 · 1 AUDLEY ST
Check before you build
Site-specific exception 900.12.10(61)
Needs a closer look20 site-specific rules and 20 older by-laws that still prevail apply to this lot. They can override the standard rules on this page.
Zoning By-law 569-2013, Chapter 900
These parts of the exception apply to this lot's address.
- Rule A
On 1 Audley Street and 8 Newcastle Street, as shown on Diagram 1 of By-law 683-2023(OLT), if the requirements of Section 6 and Section A of By-law 683-2023(OLT), are complied with, buildings or structures may be constructed in compliance with Regulations
- Rule B
to (T) below; (B) Despite Regulation 50.5.40.10(1) and (2), the height of the building or structure is the vertical distance between the Canadian Geodetic Datum elevation of 95.40 metres and the highest point of the building or structure
- Rule C
Despite Regulation 50.10.20, Public Parking is a permitted use, if located entirely below ground
- Rule D
Despite Regulation 50.10.40.10(1), the permitted maximum height of a building or structure is the number, in metres, following the letters "HT" as shown on Diagram 3 of By-law 683-2023(OLT); (i) For the purposes of this exception, the permitted maximum height of a building or structure is inclusive of the mechanical penthouse
- Rule E
Despite Regulation 50.10.40.10(4), the permitted maximum number of storeys of a building or structure is the number following the letters "ST" as shown on Diagram 3 of By-law 683-2023(OLT); (i) For the purposes of this exception, a mezzanine and mechanical penthouse do not constitute a storey
- Rule F
Despite Regulations 50.5.40.10(3), (4), (5) and (6) and (D) above, the following elements of a building or structure may project above the permitted maximum building heights as shown on Diagram 3 of By-law: 683-2023(OLT); (i) fences, raised planters, landscape features, light fixtures, seating, bollards, trellises and guardrails associated with an outdoor amenity space by a maximum of 3.0 metres; (ii) a railing or railings, balcony dividers, fences, or privacy gates and skylights located at each of the roof levels of the building by a maximum of 1.8 metres; (iii) a parapet, including roof drainage, thermal insulation and roof ballast, at each of the roof levels of the building by a maximum of 1.5 metres; (iv) elements associated with a green roof by a maximum of 1.5 metres; (v) elements or structures used for outside or open air recreation, safety, acoustic or wind protection purposes by a maximum of 3.0 metres; (vi) stairs, stair enclosures, stair towers, access corridors to stairs and elevator overruns by a maximum of 4.0 metres; (vii) spires, ornamental, decorative, art or architectural elements, and features, located above the height of each of the roof levels by a maximum of 7.0 metres; and (viii) window washing equipment, lightning rods and exhaust flues located above the mechanical penthouse roof level by a maximum of 3.0 metres
- Rule G
The permitted maximum gross floor area of all buildings and structures on the lot is 28,900 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 28,274 square metres; and (ii) the required minimum gross floor area for non-residential uses is 500 square metres
- Rule H
In addition to the elements which reduce gross floor area listed in Regulation 50.5.40.40(3), the following element also reduces the gross floor area of a building : (i) elevator overruns
- Rule I
Despite Regulations 50.10.40.70(1) and (3) the required minimum building setbacks are as shown on Diagram 3 of By-law 683-2023(OLT)
- Rule J
Despite Sections 50.5.40.60 and 50.10.40.60, and (I) above, the following building elements may encroach into the required minimum building setbacks as shown on Diagram 3 of By-law 683-2023(OLT); (i) eaves, bulkheads, cornices, window sills, doors, columns, landscape and public art features, light fixtures, balustrades, guardrails, bollards, awnings, arcades, raised planters, patios, retaining walls, fences, vents, trellises, parapets, architectural frames, screens, wind mitigation screens and features, landscape features and seating areas, patios, terraces, damper equipment, and window washing equipment by a maximum of 1.2 metres; (ii) wheelchair and covered ramps, stairs and stair enclosures, vestibules, awnings, canopies, underground parking ramp and associated structures by a maximum of 3.0 metres; (iii) balconies and bay windows by a maximum of 2.0 metres, with the exception of balconies and bay windows on the east building face which are not permitted to project within 18.5 metres of the eastern property line; (iv) structures used for outside or open air recreation, safety or wind protection, to a maximum of 2.6 metres; and (v) ornamental, decorative or architectural elements by a maximum of 3.1 metres
- Rule K
Despite (F) and (J) above, the following development standards apply to the lands identified as "Area Subject to Provision K" on Diagram 3 of By-law 683-2023(OLT); (i) No ground mounted third party and/or non-Privately Owned Publicly Accessible Spaces (POPS) signs are permitted; (ii) Only street furniture, moveable furniture, fences/guards and other similar items or fixtures to accommodate commercial patios are permitted up to a maximum vertical dimension of 1.1 metres above the finished ground level; and (iii) The provisions in (K) i. and ii. above do not apply to prevent lighting, wind mitigation, landscaping and other pedestrian features that may be required by the City in this area
- Rule L
Despite Regulation 50.10.40.50, amenity space must be provided at a minimum rate of 2.8 square metres of combined indoor and outdoor amenity space per dwelling unit
- Rule M
Despite Regulation 200.5.10.1(1) and Table 200.5.10, the required number of parking spaces provided and maintained on the lot are not to be less than the number calculated in accordance with the following minimum ratios (fractions to be rounded down to the closest whole number), and must be located in the underground parking structure : (i) a minimum of 0.34 parking spaces per dwelling unit is required to be provided for use by residents; (ii) a minimum of 0.09 parking spaces per dwelling unit is required to be provided for use by residential visitors; and (iii) parking spaces for non-residential uses are not required
- Rule N
Despite 50.5.80.1(1) and (M) above, required parking spaces may be provided on a lot that is not the same lot as the use for which the parking spaces are required, provided that the parking spaces are located on the lands municipally known in 2021 as 2 and 10 Audley Street and 29, 31, 59 and 71 Portland Street
- Rule O
Despite Regulation 200.5.10(1) and Table 200.5.10.1, the total number of resident parking spaces provided pursuant to the above-noted ratio in (M) i., parking spaces for residents on the lot may be reduced at a rate of 4 parking spaces for each car-share parking space, provided the maximum permitted reduction is calculated using the following formula: 4 x (total number of dwelling units divided by 60), rounded down to the nearest whole number; (i) "car-share" means the practice whereby a number of people share the use of one or more motor vehicles that are owner by a profit or non-profit carsharing organization and such car-share motor vehicles are made available to at least the occupants of the building or short term rental, including hourly rental; (ii) "car-share parking space" means a parking space exclusively reserved and used only for car-share purposes whereby the vehicle is accessible to at least the occupants of the buildings
- Rule P
Despite Regulation 200.5.10.1(12) and (M)(i) above, the total minimum number of parking spaces required for residents on the lot may be reduced at a rate of 1 parking space for every 5 bicycle parking spaces provided in excess of the minimum number of bicycle parking spaces required, if the reduction of parking spaces is not greater than 20 percent of the total minimum parking spaces required
- Rule Q
Despite Article 220.5.10, one Type "G" loading space is required to be provided and maintained on the lot
- Rule R
Despite Regulation 230.5.1.10(4), the minimum horizontal dimension for bicycle parking spaces in a vertical position or in a bicycle stacker is 0.45 metres
- Rule S
Despite Regulation 230.5.1.10(9), "long term" bicycle parking spaces may be located outdoors or indoors, on the ground level, below grade or above grade
- Rule T
Despite Regulation 230.5.10.1, the number of bicycle parking spaces provided and maintained on the lot must be in accordance with the following minimum rates: (i) 0.68 "long-term" bicycle parking spaces per dwelling unit are required to be provided on the lot ; and (ii) 0.07 "short-term" bicycle parking spaces per dwelling unit are required to be provided on the lot . Prevailing By-laws and Prevailing Sections: (None Apply)
- Older by-law A
On 1 Audley Street and 8 Newcastle Street, as shown on Diagram 1 of By-law 683-2023(OLT), if the requirements of Section 6 and Section A of By-law 683-2023(OLT), are complied with, buildings or structures may be constructed in compliance with Regulations
- Older by-law B
to (T) below; (B) Despite Regulation 50.5.40.10(1) and (2), the height of the building or structure is the vertical distance between the Canadian Geodetic Datum elevation of 95.40 metres and the highest point of the building or structure
- Older by-law C
Despite Regulation 50.10.20, Public Parking is a permitted use, if located entirely below ground
- Older by-law D
Despite Regulation 50.10.40.10(1), the permitted maximum height of a building or structure is the number, in metres, following the letters "HT" as shown on Diagram 3 of By-law 683-2023(OLT); (i) For the purposes of this exception, the permitted maximum height of a building or structure is inclusive of the mechanical penthouse
- Older by-law E
Despite Regulation 50.10.40.10(4), the permitted maximum number of storeys of a building or structure is the number following the letters "ST" as shown on Diagram 3 of By-law 683-2023(OLT); (i) For the purposes of this exception, a mezzanine and mechanical penthouse do not constitute a storey
- Older by-law F
Despite Regulations 50.5.40.10(3), (4), (5) and (6) and (D) above, the following elements of a building or structure may project above the permitted maximum building heights as shown on Diagram 3 of By-law: 683-2023(OLT); (i) fences, raised planters, landscape features, light fixtures, seating, bollards, trellises and guardrails associated with an outdoor amenity space by a maximum of 3.0 metres; (ii) a railing or railings, balcony dividers, fences, or privacy gates and skylights located at each of the roof levels of the building by a maximum of 1.8 metres; (iii) a parapet, including roof drainage, thermal insulation and roof ballast, at each of the roof levels of the building by a maximum of 1.5 metres; (iv) elements associated with a green roof by a maximum of 1.5 metres; (v) elements or structures used for outside or open air recreation, safety, acoustic or wind protection purposes by a maximum of 3.0 metres; (vi) stairs, stair enclosures, stair towers, access corridors to stairs and elevator overruns by a maximum of 4.0 metres; (vii) spires, ornamental, decorative, art or architectural elements, and features, located above the height of each of the roof levels by a maximum of 7.0 metres; and (viii) window washing equipment, lightning rods and exhaust flues located above the mechanical penthouse roof level by a maximum of 3.0 metres
- Older by-law G
The permitted maximum gross floor area of all buildings and structures on the lot is 28,900 square metres, of which: (i) the permitted maximum gross floor area for residential uses is 28,274 square metres; and (ii) the required minimum gross floor area for non-residential uses is 500 square metres
- Older by-law H
In addition to the elements which reduce gross floor area listed in Regulation 50.5.40.40(3), the following element also reduces the gross floor area of a building : (i) elevator overruns
- Older by-law I
Despite Regulations 50.10.40.70(1) and (3) the required minimum building setbacks are as shown on Diagram 3 of By-law 683-2023(OLT)
- Older by-law J
Despite Sections 50.5.40.60 and 50.10.40.60, and (I) above, the following building elements may encroach into the required minimum building setbacks as shown on Diagram 3 of By-law 683-2023(OLT); (i) eaves, bulkheads, cornices, window sills, doors, columns, landscape and public art features, light fixtures, balustrades, guardrails, bollards, awnings, arcades, raised planters, patios, retaining walls, fences, vents, trellises, parapets, architectural frames, screens, wind mitigation screens and features, landscape features and seating areas, patios, terraces, damper equipment, and window washing equipment by a maximum of 1.2 metres; (ii) wheelchair and covered ramps, stairs and stair enclosures, vestibules, awnings, canopies, underground parking ramp and associated structures by a maximum of 3.0 metres; (iii) balconies and bay windows by a maximum of 2.0 metres, with the exception of balconies and bay windows on the east building face which are not permitted to project within 18.5 metres of the eastern property line; (iv) structures used for outside or open air recreation, safety or wind protection, to a maximum of 2.6 metres; and (v) ornamental, decorative or architectural elements by a maximum of 3.1 metres
- Older by-law K
Despite (F) and (J) above, the following development standards apply to the lands identified as "Area Subject to Provision K" on Diagram 3 of By-law 683-2023(OLT); (i) No ground mounted third party and/or non-Privately Owned Publicly Accessible Spaces (POPS) signs are permitted; (ii) Only street furniture, moveable furniture, fences/guards and other similar items or fixtures to accommodate commercial patios are permitted up to a maximum vertical dimension of 1.1 metres above the finished ground level; and (iii) The provisions in (K) i. and ii. above do not apply to prevent lighting, wind mitigation, landscaping and other pedestrian features that may be required by the City in this area
- Older by-law L
Despite Regulation 50.10.40.50, amenity space must be provided at a minimum rate of 2.8 square metres of combined indoor and outdoor amenity space per dwelling unit
- Older by-law M
Despite Regulation 200.5.10.1(1) and Table 200.5.10, the required number of parking spaces provided and maintained on the lot are not to be less than the number calculated in accordance with the following minimum ratios (fractions to be rounded down to the closest whole number), and must be located in the underground parking structure : (i) a minimum of 0.34 parking spaces per dwelling unit is required to be provided for use by residents; (ii) a minimum of 0.09 parking spaces per dwelling unit is required to be provided for use by residential visitors; and (iii) parking spaces for non-residential uses are not required
- Older by-law N
Despite 50.5.80.1(1) and (M) above, required parking spaces may be provided on a lot that is not the same lot as the use for which the parking spaces are required, provided that the parking spaces are located on the lands municipally known in 2021 as 2 and 10 Audley Street and 29, 31, 59 and 71 Portland Street
- Older by-law O
Despite Regulation 200.5.10(1) and Table 200.5.10.1, the total number of resident parking spaces provided pursuant to the above-noted ratio in (M) i., parking spaces for residents on the lot may be reduced at a rate of 4 parking spaces for each car-share parking space, provided the maximum permitted reduction is calculated using the following formula: 4 x (total number of dwelling units divided by 60), rounded down to the nearest whole number; (i) "car-share" means the practice whereby a number of people share the use of one or more motor vehicles that are owner by a profit or non-profit carsharing organization and such car-share motor vehicles are made available to at least the occupants of the building or short term rental, including hourly rental; (ii) "car-share parking space" means a parking space exclusively reserved and used only for car-share purposes whereby the vehicle is accessible to at least the occupants of the buildings
- Older by-law P
Despite Regulation 200.5.10.1(12) and (M)(i) above, the total minimum number of parking spaces required for residents on the lot may be reduced at a rate of 1 parking space for every 5 bicycle parking spaces provided in excess of the minimum number of bicycle parking spaces required, if the reduction of parking spaces is not greater than 20 percent of the total minimum parking spaces required
- Older by-law Q
Despite Article 220.5.10, one Type "G" loading space is required to be provided and maintained on the lot
- Older by-law R
Despite Regulation 230.5.1.10(4), the minimum horizontal dimension for bicycle parking spaces in a vertical position or in a bicycle stacker is 0.45 metres
- Older by-law S
Despite Regulation 230.5.1.10(9), "long term" bicycle parking spaces may be located outdoors or indoors, on the ground level, below grade or above grade
- Older by-law T
Despite Regulation 230.5.10.1, the number of bicycle parking spaces provided and maintained on the lot must be in accordance with the following minimum rates: (i) 0.68 "long-term" bicycle parking spaces per dwelling unit are required to be provided on the lot ; and (ii) 0.07 "short-term" bicycle parking spaces per dwelling unit are required to be provided on the lot . Prevailing By-laws and Prevailing Sections: (None Apply)
Lot facts
- Area
- 2,710 m²
- Frontage
- 60.3 mestimated, irregular lot
- Depth
- 60.5 mestimated, irregular lot
- Street
- Audley St
- Corner lot
- Yes, also on Newcastle St60.5 m along it
- Public lane
- None
- House footprint
- 867 m²roof up to 13.3 m
- Back yard
- 28.7 mhouse to rear lot line
- Side yards
- 8.6 m and 21 mhouse to side lot lines
- Buildings on the lot
- 3house, garage, sheds
- Max height
- —
- Max lot coverage
- —
House and yards are measured from the City's 3D Massing footprints, which are for illustration; a survey gives the exact figures.
- Site and Area Specific Policy 433, 862. The Official Plan has a policy for this site or area that varies the general rules. Read it before relying on zoning alone. Source
- Major Transit Station Area: Mimico. The lot is inside the Mimico Major Transit Station Area approved by the Province (Site and Area Specific Policy 692). Source
- Mimico-Judson Secondary Plan. A Secondary Plan sets more detailed land use, height and density policies for this area. Source
- Zone CRE (x61) (Commercial Residential Employment). Chapter 50, section 50.10 of the by-law. Source
Around this lot
- Minor variances approved
- 96%26 of 27 decisions
- Garden suite permits
- 4
- Laneway suite permits
- 0
- Multiplex permits
- 10
- Development applications
- 21
Within 300 m, last 10 years. 14 suite and multiplex permits: more than at 81% of Toronto houses (median 3). 27 variance decisions: more than at 59% of Toronto houses (median 19).
Latest activity nearby
- Minor variancePending
To construct a new 14-storey affordable rental building with co-op units that will contain a total of 183 rental dwelling units. The development will be located within Block B on the property municipally known as 18 Buckingham Street.
18 BUCKINGHAM ST · Dec 3, 2026 · 149 m away - Building permit
Proposed interior alterations to allow a four plex residential ,underpin existing footings and new basement walkout, new porch
25 MILTON ST · Oct 27, 2026 · 275 m away - Building permit
Installation of Main Drain Pipe Backwater Valve
173 MELROSE ST · Sep 16, 2026 · 221 m away - Zoning review
Cancelled
89 ALBERT AVE · Aug 21, 2026 · 248 m away - Zoning review
Closed
8 NEWCASTLE ST · Aug 18, 2026 · 35 m away - Building permit
Proposed construction of a four unit multiplex and a new garden suite on a vacant lot.
12 CAVELL AVE · Aug 17, 2026 · 215 m away - Building permit
Proposed construction of a four unit multiplex and a new garden suite on a vacant lot.
10 CAVELL AVE · Aug 17, 2026 · 220 m away - Zoning review
Closed
2 AUDLEY ST · Aug 6, 2026 · 71 m away - Building permit
Proposal for a secondary storey rear addition, 2 storey side addition and interior alterations
181 MELROSE ST · Jul 6, 2026 · 221 m away - Development application
Proposal includes 5 mixed-use towers, ranging in heights of 34-54 storeys with 2,631 residential rental units and 415 vehicular parking spaces within a two-level below-grade parking structure. The proposal also conveys 5,499 square metres of City-owned land for a new public road.
2 AUDLEY ST · Jun 26, 2026 · 55 m away · City file
Neighbourhood: Mimico-Queensway
About the area around the lot, not the lot itself.
- Nearest station
- Mimico GO Station6 min walk
- Nearest TTC stop
- Portland St at Milton St West Side3 min walk
- Nearest cycling route
- Royal York RdBike Lane, 6 min walk
- Nearest traffic count
- 1,102 vehicles in 8 hCavell Ave / Superior Ave, 200 m away, Dec 15, 2021
- Serious collisions within 500 m
- 12021–2026, killed or seriously injured: 0 fatal, 0 with pedestrians, 0 with cyclists
- Parks
- Manchester Park2 min walk
- Queens Avenue Parkette4 min walk
- Grand Avenue Park6 min walk
Schools within 1 km
- GEORGE R GAULD JR SCHOOL English Public 6 min walk
- OAK LEARNERS Private 7 min walk
- DAVID HORNELL JR SCHOOL English Public 8 min walk
- ST LEO CATHOLIC ELEMENTARY SCHOOL English Separate 9 min walk
- ST LEO CATHOLIC ELEMENTARY SCHOOL (FUTURE ADDRESS FOR MAIN ENTRANCE) English Separate 10 min walk
- PHOENIX MONTESSORI SCHOOL Private 11 min walk
Being near a school does not mean the lot is in its catchment; check with the board.
2021 Census
| Figure | Mimico-Queensway | Median neighbourhood |
|---|---|---|
| Median household income (2020) | $84,000 | $84,500 |
| Households that own their home | 53% | 54% |
| Population (2021) | 17,045 | 16,813 |
| Homes built in 1960 or before | 43% | 29% |
| Homes needing major repairs | 7% | 7% |
Statistics Canada 2021 Census, 25% sample, by City of Toronto neighbourhood.
Police-reported crime, 2025
| Per 100,000 people | Mimico-Queensway | City median |
|---|---|---|
| Assault | 4209.2 | 636.3 |
| Robbery | 41.5 | 69.5 |
| Homicide | 4.2 | 5.3 |
| Auto theft | 224.2 | 192.6 |
| Theft over $5,000 | 66.4 | 46.1 |
| Break and enter | 132.8 | 172.8 |
| Theft from vehicles | 99.6 | 188.1 |
Neighbourhood totals from the Toronto Police Service. Rates are per resident, so areas with many visitors and few residents read high.